Renovation, Modernization Refurbishment of Existing Room for University Datacentre at University Main Campus Shalimar
2021_SKUST_152192_1
e-NIT 04 of FRESH 2021(ARIS)
Open Tender
Miscellaneous Services
Item Wise
30 days
Shalimar Srinagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Yes
Incharge ARIS
₹96,000
Yes
30 Dec 2021
8 Dec 2021
17 Dec 2021
8 Dec 2021
16 Dec 2021
8 Dec 2021
Amount
Raised Flooring Supply and Installion of Raised Access Floor in size 600mm x 600mm x 35mm in (Size 20 ft. X 15 ft.) antistatic HPL at an elevation of 300mm FFH (Reputed OEM and ISI Standard)
Supply and Installation of Server Rack 42U Physical Attributes Height :42U Rack Type :Floor mount with caster wheels Wire Managers :Two vertical and four horizontal Power Distribution :( 5Amp sockets) power distribution Door :Glass door in front with lock Fan trays :With 4 fans Depth :1000 mm Metal : Aluminium/sheet steel 9 folded profile of 1.6 mm thick sheet steel 3 point locking: static load of 1.5 tons Side panels :Detachable side panels Width :19” Equipment mounting, extra width is recommended for Managing Voluminous Cables Castors: Suitable Castors with Brakes (Make: APC/Rittal/ Dlink/ Dell)
Supply and Installation of Modular Network Rack 42U Physical Attributes Height :42U Rack Type :Floor mount with caster wheels Wire Managers :Two vertical and four horizontal Power Distribution :( 5Amp sockets) power distribution Door :Glass door in front with lock Fan trays :With 4 fans Depth :1000 mm Metal : Aluminium/sheet steel 9 folded profile of 1.6 mm thick sheet steel 3 point locking: static load of 1.5 tons Side panels :Detachable side panels Width :19” Equipment mounting, extra width is recommended for Managing Voluminous Cables Castors: Suitable Castors with Brakes (Make: APC/Rittal/ Dlink/ Dell)
Supply and Installation of Access Flooring Cable Tray and Electrical Work Cable Tray/Cable Management Module: Electric Wiring/ earthling Laying of electrical wires from main Supply/ Panel/ Board to the Server/Network Racks. (Includes material, delivery and installation) Supply, Installation, Laying, Termination, Testing & Commissioning of Centralizing Electric wiring to Supply uninterrupted Power to all Network/Server Racks with Earthing (as per prescribed code/ specifications), Structured Electric Switch Socket Panel Points to connect Racks, Conduit, all accessories, etc. (Reputed OEM Brand)
Supply and Installation of Precision Air Conditioning (PAC) System Capacity Capacity 2 Tonnage, Cooling 50000 BTU/Hr, Compressor Rotary, Refrigerant R-22 type, Power Supply 230V/Ph. Cooling Performance EER 10.6, Air Circulation CFM 1030, Noise level <50db. (Reputed OEM Brand)
Supply and Installation of Fire Estinguisher Prevention and Detection System (Ruputed OEM Brand)
Supply and Installation of Temperature and Humidity Management System (Ruputed OEM Brand)
Supply and Installation Access Control and Surveillance System (Ruputed OEM Brand)
Supply and Installtion of Rodent Control Management System (Ruputed OEM Brand)
Migration of Existing Network Infrastructure to a new location within the premises which includes, CPE’s, ISP’s Lease Lines, UTM Firewall, 130 No. SM Fibre, 24 No. MM Fibre, LIU’s, BAS Server, Core Switch’s etc.
Supply and Installation of Earthing Copper with separate rack connectors Chemical Earthing (Includes material, delivery and installation) (ISI Standard)
Supply and Installation of UPS, N+1 (Parallel Redundancy) 6 KVA /240V Online UPS’s with 02 hour Battery Back-Up (APC/Emersion/Eaton Make)
Supply and Installation of Layer-3 48 Port Aggregation Core Switch with following minimum specification:- x 1G SFP Ports and 4 x 10G SFP Ports from day 1, Switch should must be loaded with 24*1G LX SFP and 2x10G LR SFP+ Modules, minimum 2 nos. QSFP+ based 40 GE ports for uplink/stacking from day 1, Switching capacity atleast 336 Gbps, Forwarding performance minimum 250 Mpps, Aggregate stacking bandwidth atleast 960 Gbps, Should have hot-swappable redundant Power Supplies and min. 2x hot-swappable Fan Modules, should have Single/ Multi core processor, Should support at least 4000 active VLANs, Should support management features SNMP, NTP, TACACS, RADIUS authentication, Should Support VRRP, DHCP local server, DHCP relay and DHCP snooping, Should support port mirroring & IPv6, Switch should be mounted on a 19-Inch rack, etc. (Juniper/Cisco/Aruba/Dell/Rucks/Extreme Make)
Supply and Installation of high performance Network Router with following minimum specification:- 12 Gigabit Ports, 4 SFP Ports for 10 G Connectivity, Multi Core Processor, Should have min. 16 Gbits throughput, Should have min. 28.0 Mpps fast-path forwarding rate (wire speed for all ports ) etc. (Juniper/Cisco/MikroTik/ Rucks/ Aruba Make)
Supply and Installation of NMS software: To monitor entire campus network at main data centre (ARIS) With one time license. The NMS Software should be compatible to all OEM (Complete Job)
Note:This is Tentative quantity for comparative purpose and is subjected to increase or decrease
smpowercom
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .