Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING L1 BIDDER | |
| 2 | L2₹36.8 L+₹1.1 L (3.05%)Rejected-AOC 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L2 | Rejected-AOC NOT ACCEPTED BEING L2 BIDDER | |
| 3 | L3₹38.0 L+₹2.2 L (6.24%)Rejected-AOC | L3 | Rejected-AOC NOT ACCEPTED BEING L3 BIDDER | |
| 4 | L4₹38.4 L+₹2.7 L (7.47%)Rejected-AOC | L4 | Rejected-AOC NOT ACCEPTED BEING L4 BIDDER | |
| 5 | L5₹39.4 L+₹3.7 L (10.4%)Rejected-AOC | L5 | Rejected-AOC NOT ACCEPTED BEING L5 BIDDER |
Tender Value
₹42.8 L
EMD Value
₹85,600
Closing Date
24 Aug 2021, 6:00 pmClosed
CWE PANAGARH
HQ CWE PANAGARH, MES, PO- PANAGARH, DIST- BURDWAN, WB-713420
PROVISION OF LED LIGHTS WITH POLE AT NABAGRAM MILITARY STATION UNDER GE (P) PANAGARH
2021_MES_462687_1
8704/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NABAGRAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (P) PANAGARH
₹85,600
Yes
14 Sept 2021
26 Jul 2021
26 Aug 2021
26 Jul 2021
24 Aug 2021
18 Aug 2021
Amount
M&L for Earthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point including testing on completion including earthing pit with cover suitable size , complete all as specified and as directed by Engrs-In-Charge.
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) including two coats of aluminium based paint over one coat of primer, complete all as specified and as directed by Engrs-In-Charge.
Supply and fixing LED street light fittings on poles all as conforming to the following : (i) System watt/lumens:- Max 72 watts/total system lumen not less than 7200 lm (ii) Housing:- High pressure die cast aluminium (iii) IP Rating :-IP 65 (iv) Front cover :- Toughened Clear Glass (v) mounting :- Suitable for pole mounting with bracket arm 40-50 mm dia Mounting height (vi) Finish: Epoxy powder coated with any additional treatment for smooth and anti (vii) Lamp :- High bright LED with Lens (viii) System Efficiency (lm/W) of the luminaries:- not less than 110 lm/watt (ix) Colour temperature(k) :- not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 74 (xi) Life:- Burning Hours not less than 50000 Hrs of operation (xii) Optics :- Spread ( beam angle along the driveway)-120 degree throughbeam angle (xiii) Control Gear :- inbuilt electronic driver with APFC, PF not less than 0.90 and THD (xiv) Surge protection:- inbuilt surge protection minimum 10 KV (xv) Heat Shink :- As per OEM 's Design (xvi) Bidder has to compulsorily submit the LM -79 and LM-80 test report from NABL Lab.
Supply , laying and testing cable XLPE insulated ,screened ,PVC bedded ,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 4 core for connection of LT panel to street light/flood light panel , complete all as specified and as directed by Engrs-In-Charge.
Supply , laying and testing cable XLPE insulated ,screened ,PVC bedded ,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core for connection of street light/flood light panel, complete all as specified and as directed by Engrs-In-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Soft /loose soil complete, complete all as specified and as directed by Engrs-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. , complete all as specified and as directed by Engrs-In-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point , complete all as specified and as directed by Engrs-In-Charge.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying , complete all as specified and as directed by Engrs-In-Charge. Note : Punned thickness shall be measured
M&L for Bricks; common burnt clay building bricks, sub-class ‘A’ designation 75 for cable protection , complete all as specified and as directed by Engrs-In-Charge.
M&L for plain cement concrete 1:4:8 type D-2 ( using 40 mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed by Engrs-In-Charge.
M&L for PCC (1:2:4) type B-1 ( using 20 mm graded stone aggregate) as in coping , bed plates, kerbs, etc including necessary form work complete all as specified and as directed by Engrs-In-Charge.
Supply and fix junction box Polycarbonate complete with terminal block 4 pole and MCB SP 3 A / 6 A with neutral block for street light with necessary nut bolts and clamps for fixing on Pole , complete all as specified and as directed by Engrs-In-Charge.
S&F street light bracket 1.5 m made with 40 mm dia medium grade GI Pipe with 300 mm dia and 380 mm length pole top MS cover including primer and paint up to 1.5 M length , complete all as specified and as directed by Engrs-In-Charge.
Supply, laying & testing PVC insulated , PVC sheathed cable unarmoured, with stranded copper conductor of size 1.5 sqmm 3 core 240 Volts grade including PVC / Steel conduit and clamp suitable size , complete all as specified and as directed by Engrs-In-Charge. Note:- Cable used for street light connection from junction box to street light
Boring of holes of dia 80 mm under road, pavement & hard standing , complete all as specified and as directed by Engrs-In-Charge.
S&F 50 mm bore GI tubing medium grade ISI marked for protection of cable including fittings , complete all as specified and as directed by Engrs-In-Charge.
Ultimate Solution Company
S S ENTERPRISE
M/S SAIMON ENGINEERING
ANSH CONSTRUCTION
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS
TOTCO
Lotas Engineers
NIRMAL SALES CORPORATION
Abida Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .