Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | ₹8.8 L Quoted ₹9.2 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹10 L+₹82,780 (9.03%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | ₹10 L+₹82,780 (9.03%) | L2 | Rejected-Finance other than lowest |
| 3 | L3₹12.2 L+₹3.0 L (32.8%)Rejected-Finance H NO 21666 POWER HOUSE ROAD STREET NO 9 BATHINDA PB 151001 | BATHINDA | PUNJAB | 151001 | ₹12.2 L+₹3.0 L (32.8%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹17.9 L+₹8.7 L (94.7%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | ₹17.9 L+₹8.7 L (94.7%) | L4 | Rejected-Finance other than lowest |
| 5 | L5₹18.5 L+₹9.3 L (101.5%)Rejected-Finance | ₹18.5 L+₹9.3 L (101.5%) | L5 | Rejected-Finance other than lowest |
Tender Value
₹24.7 L
EMD Value
₹49,480
Closing Date
25 May 2021, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
Repair maint of ceiling exhaust fan wall fan and geyser at AF stn Halwara
2021_MES_438722_1
GE/HAL-05/2021-22
Open Tender
Civil Works
Item Wise
273 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS E CATEGORY b (I)
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹49,480
Yes
3 Jun 2021
27 Apr 2021
27 May 2021
27 Apr 2021
25 May 2021
11 May 2021
Amount
REPAIR TO CEILING FANS Taking down carefully (dismantling) ceiling fan of any sweep and size and dismantling blades, opening up for inspection, making joint list of defects and worn out parts to be replaced, jointly by Engineer-in-Charge and contractor transporting to work shop if reqd for repairs, reassembling after repairs including replacement of spares and transportation back to store yard for inspection including hanging, fixing and connecting up and testing etc complete all as specified and directed. Note: 1. Necessary repair shall be measured & paid for separately. Also spare parts shall be measured and paid separately as supply only under respective items. 2. Fans under repair shall be issued through gate pass.
Supply only ball bearing of existing size suitable for ceiling fan 1200 / 1400 mm sweep of different makes including necessary greasing all as directed.
Supply only gun metal bush of existing size suitable for ceiling fan 1200mm/1400mm.
Supply only capacitor 2.5/2.75 MFD .
Supply only capacitor capacity 3.15 MFD.
Supply only celing fan down rod 15 mm bore, 300 mm long, factory made, colour brown/ white complete.
Supply only celing fan down rod 15 mm bore, 400 mm long, factory made, colour brown/ white complete.
Supply only blade of 1200 mm sweep of ceiling fan.
Supply only blade of 1400 mm sweep of ceiling fan.
Material and labour for Painting one coat of synthetic enamel paint (white/ brown) by spraying to steel surfaces of ceiling fan 1200mm /1400mm sweep including blades complete after preparation of surfaces including filling cavities with filler, cleaning dust and dirt etc and writing the MES number/ SM Numbers with black paint on fans all as directed.
Supply only Ceiling fan U clamp with rubber real insulator with nut bolts of size 10mm dia & 75mm long including necessary washers & split pin all as specified.
Supply only upper and lower canopy of plastic with steel screw suitable for fan 1200/1400mm sweep.
Material and replacement of flexible cord copper conductor of size 0.75 Sqmm, twin core, flat cable for connection to fans from ceiling roses complete as in repair all as specified.
Opening/ dismantling of ceilig fans any make/model of size 1200 mm sweep cutting and taking out old burnt/damaged winding /material by any means and M&L for re-winding the same with super enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan recommended quality grease/oil, re-assembling and testing complete all as specified and as directed.
Opening /dismantling of ceilig fans any make/model of size 1400 mm sweep cutting and taking out old burnt/damaged winding /material by any means and M&L for re-winding the same with super enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan recommended quality grease/oil, re-assembling and testing complete all as specified and as directed.
Supply only rotor of ceiling fan 1400mm sweep all as directed.
Supply only rotor of ceiling fan 1200mm sweep all as directed.
S&F in replacement of electronic fan regulator step, 250V flush type on the exiting phenolic laminated sheet complete all as directed.
REPAIR TO EXHAUST FAN Taking down carefully (dismantling) exhaust fan of any sweep and size dismantling blades, opening up for inspection, making joint inventories of defects and worn out parts to be replaced, jointly by Engineer-in-Charge and contractor transporting to work shop if reqd for repairs, reassembling after repairs and replacement of spares, sealing cable ends and transportation back to store yard for inspection including, fixing and connecting up and testing etc complete all as directed. Note: 1. Necessary repair shall be measured & paid for separately. Spare parts shall also be measured and paid separately as supply only under respective item. 2. Exhaust Fans under repair shall be issued through gate pass.
Rewinding motor of exhaust fan 450 mm sweep with super enamelled copper wire of existing specification, gauge and weight including insulating material all as directed.
All as per Srl item No. 20.00 above but of exhaust fan 380 mm sweep.
All as per Srl item No. 20.00 above but of exhaust fan 350 mm sweep.
All as per Srl item No. 20.00 above but of exhaust fan 300 mm sweep.
All as per Srl item No. 20.00 above but of exhaust fan 250/230 mm sweep.
Supply only capacitor capacity 4.00 MFD.
Supply only ball bearing as per existing size suitable for exhaust fan 380/450mm sweep including necessary greasing all as directed.
Supply only ball bearing as per existing size suitable for exhaust fan 200 to 350mm sweep including necessary greasing all as directed.
Supply only mounting legs with rubber bush suitable for any type of exhaust fan complete all as specifed.
Supply only exhaust fan blade of 380/450 mm sweep complete.
Supply only exhaust fan blade of upto 350 mm sweep complete.
Supply and replacement of MS sheet 1.00 mm thick, louver shutter for exhaust fan suitable size for up to 350mm sweep with all accessories, fixing on wall complete all as directed.
Supply and replacement of MS sheet 1.00 mm thick, louver shutter for exhaust fan suitable size for 350mm to 450mm sweep with all accessories, fixing on wall complete all as directed.
REPAIR TO AIR CIRCULATOR/ PEDESTAL FAN Taking down carefully (dismantling) Air circulator / Pedestal fan of any sweep and size, dismantling blades, opening up for inspection, making joint inventories of defects and worn out parts to be replaced jointly by Engineer-in-Charge and contractor transporting to work shop if reqd for repair, reassembling after repairs and replacement of spares sealing cable ends and transportation back to store yard for inspection including fixing and connecting up and testing etc complete all as directed by Engineer-in-Charge. Note: 1. Necessary repair shall be measured & paid for separately. Spare parts shall also be measured and paid separately as supply only under respective item. 2. Air circulator under repair shall be issued through gate pass.
Rewinding motor of Air Circulator up to 450 mm sweep with super enameled copper wire of existing specification, gauge and weight including insulating material all as directed.
Rewinding motor of Air Circulator 500 to 600 mm sweep with super enameled copper wire of existing specification, gauge and weight including insulating material all as directed.
Supply only ball bearing of existing size suitable for Air circulator up to 450 mm sweep including necessary greasing all as directed.
Supply only ball bearing of existing size suitable for Air circulator 500 to 600 mm sweep including necessary greasing all as directed.
Supply only gun metal bush of existing size suitable for Air circulator complete all as specified.
Supply only Plug top 6 Amps, 3 pin, ISI marked as in replacement.
Repair to Geysers Disconnecting electric/water supply connections, dismantling (taking out/down) geyser (storage type water heaters) vertical or horizontal type, 25 to 35 Litres capacity, any make, any model opening up to detect faults, defective and unserviceable parts/spares/ instruments/ equipments etc., making joint inventories by both EIC and Contractor transporting to workshop if reqd for repairs, reassembling after repairs, replacement of spare parts and overhauling, descaling, transporting back to site for inspection and installing and fixing in its original position including painting with spray gun one coat of Duco paint, writing MES No./Machine No., filling with glass wool, commissioning, testing and brazing to entire satisfaction of EIC complete all as specified. Notes: (a) Spare parts shall be measured and paid for separately as supply only under respective items of this schedule (in replacement on requirement basis). These shall be identical to those specified by original manufacturer. (b) Items indicated as "Supply and replace" are out side the scope of this item. (c) Unit rates quoted by tenderers shall deem to include for nuts, bolts, washers, lugs, thimbles, wires and petty items/ works required for efficient and smooth functioning of the equipment without any extra cost.
All as per srl item No. 40.00 above but 50 Litres capacity.
Supply only heating element including rubber washers for 1500 Watt capacity, 240V suitable type.
Supply only heating element including rubber washers for 2000 Watt capacity, 240V suitable type.
Supply only PVC connection 15mm dia with brass nut couplings at both ends, of length 450mm for hot water supply complete.
Supply only thermostat fitting/ fitment for geysers of capacity 25 to 50 Litres.
Supply only safety plug made out of brass for geyser of capacity 25 to 50 Litres.
Supply only indicator lamps (square/ round) both red and green suitable for geysers of any capacity.
Supply only Mild steel Bottom cover of geysers in two halves as in replacement.
Material and replacement of PVC flexible copper coductor cable of size 2.5 sqmm, 3 core as connections from MCB/socket to geysers all as specified.
Supply only Inner stainless steel tank of wall thickness 20 gauge and suitable for geyser of capacity 25-30 litres including taking out existing steel / copper tank.
Supply only Inner stainless steel tank of wall thickness 20 gauge and suitable for geyser of capacity 50 litres including taking out existing steel / copper tank.
Supply only 15 mm dia non return valve of gun metal for geysers as in replacement complete all as specified.
Supply only 15mm dia GI nipple hexagonal 15mm long as in replacement complete all as specified.
Supply only Geyser assembly made of copper suitable for geyser of 25/35 Litres capacity as in replacement complete all as specified.
Supply only Geyser assembly made of copper suitable for geyser of 50 Litres capacity as in replacement complete all as specified.
Supply only Glass wool for geysers of 25 to 50 Litres capacity as in replacement complete all as specified.
Supply only Plug top 15 Amps, 3 pin, ISI marked as in replacement complete.
REPAIR TO WALL MOUNTING FANS Taking down carefully (dismantling) wall mounting fan of any sweep and size and dismantling blades, opening up for inspection, making joint inventories of defects and worn out parts to be replaced, jointly by Engineer-in-Charge and contractor transporting to workshop if reqd for repairs, reassembling after repairs and replacement of spares sealing cable ends and transportation back to store yard for inspection including fixing and connecting up and testing etc complete all as directed. Note: 1. Necessary repair shall be measured & paid for separately. 2. Spare parts shall be measured and paid separately as supply only under respective item. 3. Wall mounting fan under repair shall be issued through gate pass.
Supply only electrical motor suitable for wall mounting fan of size up to 300mm sweep.
Supply only electrical motor suitable for wall mounting fan of size 350 to 450 mm sweep.
Supply only blade any size of sweep duly fitted in the frame complete.
M/S SANGA SINGH AND CO
SUNRISE ENGINEERS AND CONTRACTOR
R N Enterprises
JAI DURGA CONSTRUCTION COMPANY
JINDAL AND COMPANY
JASSI TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .