Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance 31 GROUND FLOOR SANT NAGAR EAST OF KAILASH SOUTH DELHI DELHI 110065 | SOUTH EAST DELHI | DELHI | 110065 | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹24.2 L (22.7%)Admitted-Finance CMS ROAD LUCKNOW UTTAR PRADESH 226018 INDIA | LUCKNOW | UTTAR PRADESH | 226018 | ₹1.3 Cr+₹24.2 L (22.7%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 4 | Rejected-Technical C 22 226 2ND FLOOR FLAT NO 7 GOVERDHAN APTTS GURUNANAK PURA LAXMI NAGAR NEW DELHI DELHI 110092 09818747063 LAXMI NAGAR | EAST DELHI | DELHI | 110092 | - | - | Rejected-Technical Technically Not Qualified |
| Sl No | Description | Qty | Unit | NETIP TECHNOLOGIES PVT.LTD L1 | Takyon Networks Limited L2 |
|---|---|---|---|---|---|
| 1.10 | Laying Down Fibre Cables and Core Infrastructure:
1.1 Passive components for CS and OFC Laying CC to Hostel
1. 2 x 24 Core Single mode OFC Cable
Appropriate standard to provide connectivity at least 40Gbps | 1,500 | Mtr | 2,04,000 ₹2,40,720 Lowest | 5,96,250 ₹7,03,575 |
| 1.20 | Laying Down Fibre Cables and Core Infrastructure:
1.1 Passive components for CS and OFC Laying CC to Hostel
2. The vendors must provide a complete list of compatible transceivers (10Gbps, Hot Pluggable, MSA Compliant, RoHS Compliant, Duplex LC type connector) to provide all end-to-end connectivity from CSs-to-DSs at 10Gbps bandwidth. (minimum nos. 8)
3. The vendor must include appropriate HDPE Duct Pipe, Joint Enclosures, and any other requirements.
4. The vendors must provide a complete list of compatible cables with appropriate transceivers for all end-to-end connectivity. Such as CS to CS over 40G.
5. Compatible LIU LC-to-LC, all weather outdoor box, to be installed as a junction box for 24 fibres. (2 Nos).
6. Compatible rack mountable LIU, LC-to-LC for 48 fibres. | 1 | Set | 2,62,500 ₹3,09,750 | 1,83,560 ₹2,16,600.8 Lowest |
| 1.30 | 1.2 Active Component
1.2.1 Core Switch | 2 | Nos | 13,65,000 ₹16,10,700 | 10,20,008 ₹12,03,609.44 Lowest |
| 1.40 | Wired Network:
2.1 Passive components for wired network
1. Cat6 Complete IO with wall mount box (524 for each Hostel) | 1,048 | Nos | 2,52,568 ₹2,98,030.24 Lowest | 2,55,607.2 ₹3,01,616.5 |
| 1.50 | Wired Network:
2.1 Passive components for wired network
2. Supply of ETL Verified Category 6 U/UTP Cable, low smoke zero halogen, white jacket, 4 pair count, 1000 ft (305 m) length (80 for each Hostel) | 160 | Box | 14,02,880 ₹16,55,398.4 Lowest | 14,30,880 ₹16,88,438.4 |
| 1.60 | Wired Network:
2.1 Passive components for wired network
3. Cat6 Patch Cords, 2 Mtr (524 for each Hostel) | 1,048 | Nos | 2,03,312 ₹2,39,908.16 Lowest | 2,10,165.92 ₹2,47,995.79 |
| 1.70 | Wired Network:
2.1 Passive components for wired network
4. 14 U Rack with accessories (1 for each Hostel) | 2 | Nos | 10,200 ₹12,036 Lowest | 20,648 ₹24,364.64 |
| 1.80 | Wired Network:
2.1 Passive components for wired network
5. 12 U Rack with accessories (7 for each Hostel) | 14 | Nos | 67,088 ₹79,163.84 Lowest | 1,38,096 ₹1,62,953.28 |
| 1.90 | Wired Network:
2.1 Passive components for wired network
6. Cat6 Jack-panel 24 loaded ports (8 for each Hostel) | 16 | Nos | 59,632 ₹70,365.76 | 58,096 ₹68,553.28 Lowest |
| 2.00 | Wired Network:
2.1 Passive components for wired network
7. Cat6 Jack-panel 48 loaded ports (8 for each Hostel) | 16 | Nos | 1,31,872 ₹1,55,608.96 | 1,29,264 ₹1,52,531.52 Lowest |
Tender Value
Refer Docs
EMD Value
₹3 L
Closing Date
11 Nov 2024, 5:00 pmClosed
DIRECTOR IISER MOHALI
IISER MOHALI, KNOWLEDGE CITY, SECTOR 81, S.A.S. NAGAR, MOHALI-140306
Providing of Networking Services and related Core Infrastructure for New Hostel in IISER Mohali-1675
2024_IISRM_823732_1
IISERM(1675)24/25-Pur
Open Tender
Miscellaneous Services
Works
30 days
IISER MOHALI
AS PER TENDER NOTICE
8 documents required · 8 mandatory
₹590
Yes
REGISTRAR IISER MOHALI
₹3 L
Yes
ADMIN BUILDING
13 Feb 2025
30 Aug 2024
12 Nov 2024
30 Aug 2024
11 Nov 2024
30 Aug 2024
10 Sept 2024
Laying Down Fibre Cables and Core Infrastructure: 1.1 Passive components for CS and OFC Laying CC to Hostel 1. 2 x 24 Core Single mode OFC Cable Appropriate standard to provide connectivity at least 40Gbps
Laying Down Fibre Cables and Core Infrastructure: 1.1 Passive components for CS and OFC Laying CC to Hostel 2. The vendors must provide a complete list of compatible transceivers (10Gbps, Hot Pluggable, MSA Compliant, RoHS Compliant, Duplex LC type connector) to provide all end-to-end connectivity from CSs-to-DSs at 10Gbps bandwidth. (minimum nos. 8) 3. The vendor must include appropriate HDPE Duct Pipe, Joint Enclosures, and any other requirements. 4. The vendors must provide a complete list of compatible cables with appropriate transceivers for all end-to-end connectivity. Such as CS to CS over 40G. 5. Compatible LIU LC-to-LC, all weather outdoor box, to be installed as a junction box for 24 fibres. (2 Nos). 6. Compatible rack mountable LIU, LC-to-LC for 48 fibres.
1.2 Active Component 1.2.1 Core Switch
Wired Network: 2.1 Passive components for wired network 1. Cat6 Complete IO with wall mount box (524 for each Hostel)
Wired Network: 2.1 Passive components for wired network 2. Supply of ETL Verified Category 6 U/UTP Cable, low smoke zero halogen, white jacket, 4 pair count, 1000 ft (305 m) length (80 for each Hostel)
Wired Network: 2.1 Passive components for wired network 3. Cat6 Patch Cords, 2 Mtr (524 for each Hostel)
Wired Network: 2.1 Passive components for wired network 4. 14 U Rack with accessories (1 for each Hostel)
Wired Network: 2.1 Passive components for wired network 5. 12 U Rack with accessories (7 for each Hostel)
Wired Network: 2.1 Passive components for wired network 6. Cat6 Jack-panel 24 loaded ports (8 for each Hostel)
Wired Network: 2.1 Passive components for wired network 7. Cat6 Jack-panel 48 loaded ports (8 for each Hostel)
2.2 Active Components for Wired network 2.2.1 Distribution Switch (2 for each Hostel)
2.2 Active Components for Wired network 2.2.2 Access Switch (24 port) (8 for each Hostel)
2.2 Active Components for Wired network 2.2.3 Access Switch (48 port) (8 for each Hostel)
2.3 Passive Component for wired network: 1. PVC Channels (15 x 15 mm) and accessories for installation (As per actual)
2.3 Passive Component for wired network: 2. PVC Conduit (32 mm) and accessories for installation (As per actual)
2.3 Passive Component for wired network: 3. PVC Joints (T-, I, elbow and all required one) (As per actual)
2.3 Passive Component for wired network: 4. PVC flexible pipes (for 32 mm conduit pipe) (As per actual)
2.3 Passive Component for wired network: 5. PVC Channel (50x50 mm) and accessories for installation (As per actual)
2.3 Passive Component for wired network: 6. Jack panels with matching numbers of ports for each Distribution switch. (02 for each hostel)
2.4 Installation, commissioning and services of all active and passive components for both Hostels.
Other Charges if any (A)
Other Charges if any (B)
Other Charges if any (C)
Other Charges if any (D)
Other Charges if any (E)
Other Charges if any (F)
Other Charges if any (G)
Other Charges if any (H)
Other Charges if any (I)
Other Charges if any (J)
Other Charges if any (K)
Other Charges if any (L)
Other Charges if any (M)
Other Charges if any (N)
Other Charges if any (O)
Takyon Networks Limited (BID ID -3118458)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .