Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC 695 NEAR ANJALI CLINIC SHIV PALACE SHANTI VIHAR BADAUN ROAD SUBHASH NAGAR BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L1 | Accepted-AOC ok | |
| 2 | L2₹24.0 L+₹2,620.84 (0.11%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹30.6 L+₹6.6 L (27.6%)Rejected-AOC 176 SAINIK COLONY SANJAY NAGAR BAREILLY 243001 UP | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-AOC ok |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Aug 2022, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR TO BOUNDARY WALL/COMPOUND WALL , DRAIN, CULVERT, FENCING, GATE, PATH, HARD STANDING AND REPAIR/REPLACEMENT OF SEWAGE LINE, MH SEPTIC TANK AND SOAK PIT ETC IN ZONE II AND III UNDER AGE B/R- II AT GE (W) BAREILLY.
2022_MES_532812_1
8062/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹96,000
Yes
7 Sept 2022
22 Jun 2022
8 Aug 2022
22 Jun 2022
4 Aug 2022
9 Jul 2022
23 Jun 2022 - 8 Jul 2022
Amount
M&L for cleaning /function of existing sewage system consisting of SGSW pipes, RCC hume pipes , CI pipes and PVC pipes of any dia at any depth, manholes of different sizes and depth of different size and capacity, waste and vent pipes fixed on walls, nahani/floor trap inside the bldgs,and gully trap outsides the bldgs etc incl removal of all blockage in the system, dewatering and desludging manholes by using honey sucking machine/ mechanical sewage suction pump and removal of sludge in covered vehicles outside the MD land all as specified and directed by Engr-in-charge. The unit rate quoted shall deemed to inclusive of the followings
(i) Contractor has to engage Four safaiwala and one supervisor with mobile phones having no photo facility. The team must be reported in the complaint cell/ sub div in proper uniform and with all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, etc for execution of the item. The quoted rate shall also be included the cost of conveyance of workers, supervisors, materials and T&P.
(ii) Team of workers with T&P shall be attanded the complaints of the entire area as directed by Engr-in-charge and the completion of work shall be reported by 05:00 PM of every working day.
(iii) Contractor or his representative shall report daily at 08:30 AM in the office of Engr-in-charge/ complaint cell to receive complaint slip and necessary directions. Complaints received from JE/Engr-in-charge through telephone message also shall be attended on the same day.
(iv) Attendance register shall be maintained by Engr-in-charge at sub divn/ complaint cell. In case of absence of workers a penal recovery of Rs 500 per day per worker shall be imposed on contractor.
(v) A complaint register shall be maintained by JE and proper record of compliants received and attended with date and time shall be recorded and shall be signed daily by both the parties. Complaint register shall be kept on record of Engr-in-Charge after completion of work.
(vi) Complaints of blockage of sewage line/ manhole/ nahani trap if an attended within 24 hours after issuance of compliant slips or telephonic directional a penalty of Rs 300/- per each complaint shall be imposed on contractor.
(vii) GE/Engr-in-charge will have no liability to give permanency of the employment of workers. A certificate in this regard will be rendered by contractor prior to the commencement of the work.
(viii) Payment to the workers shall be properly receipted. A certificate shall be produced by the contractor that the every employee engaged by him have been paid their wage in full.
(ix) Contractor will not permitted to engage child labour in the work.
(x) Contractor shall provide uniform with name plate as approved by Engr-in-charge to the workers.
(xi) Supervison shall be obtained necessary directions from JE/Engr-in-charge and supervise the workers.
(xii) Each worker shall be submitted affidavit in stamp paper duly notary that he will not claim employment from department.
(xiii) Contractor shall submit accident /risk insurance policy of each worker engaged in cleaning sewage system.
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 m in depth, getting out in soft/loose soil etc., in luding trimming bottom and sides of trenches, leveling/grading and ramming bottom of excavation complete all as specified and directed
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil, complete all as specified and directed.
Removing surplus excaveted soil to a distance exc 250 Mtr and nexc 500 Mtr depositing where directed at a level n. exc 1.5 Mtr above the starting point complete all as specified and directed.
Surface dressing in soft/ loose soil incl cleaning the area, bushes,, shrubs etc and removing upto 50 distatance, complete all as specified and directed.
M&L for spraying of weed remover Herbiside Round Up chemical to burn the vegitation as per manufacturer instructions and removing the waste to a distance not exc 50 mtr.
Pumping out of water/liquid/sludge/any other waste/materials stagnated in septic tank/soak wells and discharge the same to nallah/drains through hose pipe upto distance of 250mtr, complete all as specified and directed by Engr -in - Charge.
Cleaning of septic tank /manholes of any depth/area/condition including taking out all the stagnated sludge or any other material mixed with the sludge etc complete and disposal of all spoils/waste or any other materials upto a distance exc 200 mtrs but n.exc 500 mtrs
Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced) 100mm dia set in cement mortar all as spd and directed
ditto but 150mm bore
ditto but 200mm bore
M &L for 100mm bore SGSW drain pipe (Grade-A) laid in trenches and jointed in CM 1:1 laying over concrete bed for 100mm in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) to drain pipes including packing under,haunching against the sides of pipes after they are laid and tested complete all as spd and directed
M&L for 150 mm bore reinforced concrete pipes class N P-2, laid and jointed complete with collars layring over concrete bed for 150mm in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) to drain pipes including packing under,haunching against the sides of pipes after they are laid and tested all as specified and directed
M&L for 200 mm bore reinforced concrete pipes class N P-2, laid and jointed laying over concrete bed for 200mm in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) to drain pipes including packing under,haunching against the sides of pipes after they are laid and tested complete with collars all as specified and directed
Cutting into existing manholes for connecting new drains making good to open and rendering, cutting out existing benching for and forming branch channel 1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1,smooth finished and reforming benching
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation bed of manhole, drains and steel post embeded etc all as specified and directed.
M&L for PCC 1:2:4 type B-1(using 20 mm graded stone aggregate) as in channels/benching of manhole, laid to shape and slope and surfaces finished even and smooth using extra cement, complete including all form work etc all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick (internal faces of manholes ST in CM 1:4 mixed with water proofing compouind where ever required in proportion as per manufacturer"s instructions, including finishing the surfaces even & smooth without using extra cement.
Supply only integral water proofing compound (powder).
M & L proving pre cast reinforced cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) as in landing cover slab for main holes chullah hoods chajjas water toughs manger shelves and similar articles with plain faces setting in CM (1:6) all as spd and directed. Note size as specified by engr -in-chage
M&L providing pre cast reinforced cemnent concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in precast RCC manhole / septic tanks covers including all form work and setting in CM 1:4 all as specified and shown on drgs. Note size as specied by engri-in- charge
Supply and fix TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0, complete all as specified.
Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles all as spd and directed
M&L for Brickwork with fly ash brick in CM 1: 4 straight or curved on plan exc 6 m mean radius .
M & L Brick work with sub class B bricks, straight or curved on planexc 6m mean radious built in CM (1:6) etc as directed .
Taking down cement or cement lime plaster any description on brick walls etc. including racking out joints hacking for keys scrubbing down with water.
M&L rendering 15 mm thick in CM 1:4 on brick work (other than fair faces)including finishing the surface fair and even without using extra cement.
M&L 15mm thick cement plaster on brick surfaces or concrete surfaces in narrow width, patches, jambs, cornices, bands etc n exc 3 Sqm each in cm (1:4) including finishing the surface even and fair all as spd and directed
M & L applying two coats of cement based paint on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified.
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground, embedded with concrete etc complete all as specified.
Dismantling of old barbed wire fencing complete all as specified and directed by Engineer-in-Charge.
Excavation in Post holes (or similar holes ) in any type of soil, each not exe 0.5 cum , getting out , returning filling and ramming carts not exc 25cm , watering and removing surplus soil to a distance not exc 50 mtr and making good surface complete
Fixing only chain link fencing including line wires any mesh, size and type to any type of standards, rails, straining bolt, etc including provision of binding wire complete all as spd and directed.
S&F galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type standard rails, staining bolts incl securing, tying at crossing with and provision of galvanized steel wire staple or steel pins etc as directed fixed in repairs. (Each line to be measured)
Supply only chain link MS galvanised fencing any size or type complete all as spd and directed.
S&F M S Posts and struts in fencing (any size of angle) mm including cutting tops to shapes as directed including driling holes for bolting of MS flat iron in horizontal, vertical & diagnal faces of each pannel to be intertwined with Chain link fencing, and fixed to posts with MS nut bolts of exc 5 cm n exc 10 cm in lenth and 10-15 mm dia and washers ,wind ties for sign board posts and struts, MS round bars and similar work confirming to Fe 290 Gde E-165 complete all as spd and directed
M & L for Steel work in tubular hollow section of framing for fiber sheets, rail including special shaped washer etc complete all as specified and directed.
S&F in repair fiber sheets 1.5 mm thick of any colour having high tensile strength fixed with existing chain link fencing or on post with self screw and nut bolts all necessary fittings complete all as specified and directed. Note : Sheet colour approved by GE
S&F in repair fiber sheets 1.5 mm thick of any colour having high tensile strength fixed with MS plate, self screw and nut bolts all necessary fittings complete all as specified and directed. Note : Sheet colour approved by GE
S&F mild steel round bars 10mm dia and over cut to length , bent to shape required, including cranking, bending spirally for hooping columns, hooking ends and binding with and including M.S wire (annealed) n.less than 0.9mm dia or securing with clips
S&F mild steel round bars 12mm dia and over cut to length , bent to shape required, including cranking, bending spirally for hooping columns, hooking ends and binding with and including M.S wire (annealed) n.less than 0.9mm dia or securing with clips
M & L for reinforced cement concrete M-25 (20 mm graded) for culvert, Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
Formwork to sides of Rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and fastening and fixing complete FE 290 Gde E-165
S&F Welded steel wire fabric weight n exc 4 kg/sqm supplied and fixed complete to wood or steel members
Taking down steel gates any type and size.
M & L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M&L for painting to new steel surface exc 10 cm width or girth with two coats of synethic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surface all as spd and directed
Removal of excess earth , waste materials already dumped at site incl. Necessary excavation upto 250 mtrs distance wherever reqd.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for all as spd and directed
Demolition of reinforced Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M&L for rbber moulded cement concrete factory made coloured glazed interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, M-35 Grade, joint with grey cement and pigment and including over 25 mm thick sand filling etc complete all as specified and directed.
M&L for rbber moulded cement concrete factory made coloured glazed interlocking paver block any shape and size confirming to IS 15658 -2006 of 80mm thickness, M-40 Grade, joint with grey cement and pigment and including over 25 mm thick sand filling etc complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20mm graded agg for machine pressesd precast cement concrete kerb stone including weathering, slightly rounded or chemferred angles and throating , as directed edges complete including excavavtion for kerb stone and filling after embeded including watering and well ramming as spd and directed by engr-in charge. Note size is approved by GE.
M&L for coloured glazed chequered cement concrete 20cm x 20cm x 25mm thick With mixture of grey and white cement in equal proportions and no pigment set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6, for laying floor finishes, laying over 25 mm thick PCC 1:2:4 type B0, using 12.5mm graded aggregate as in floors complete all as specified and directed.
Notes :
multiple alliance enterprises
SHRI BALA JI STORE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .