Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC C 347 ARBUDHA NAGAR ODHAV AHMEDABAD | AHMEDABAD | AHMEDABAD | GUJARAT | 382415 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.1 L+₹63,854.51 (1.58%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹45.0 L+₹4.5 L (11.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹47.0 L+₹6.5 L (16.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹47.9 L+₹7.4 L (18.2%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
22 Apr 2024, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
REPAIR AND MAINTENANCE OF EXISTING PIPELINES, WATER SUPPLY INSTALLATION, RO PLANT AND FIRE ALARM SYSTEM AND STP AT AREA A, B AND C AF STN WADSAR
2024_MES_647694_1
8134/24-25/E8
Open Tender
Civil Works
Item Rate
270 days
WADSAR
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹90,000
Yes
13 Jun 2024
27 Mar 2024
24 Apr 2024
27 Mar 2024
22 Apr 2024
10 Apr 2024
27 Mar 2024 - 9 Apr 2024
Amount
Supply, laying connecting and testing in repair for the following sizes of CI (Cast Iron) pipes class LA spigot and socket end pipe class K-9 suitable for and including rubber gasket joints in standard working length conforming to IS-8329 laid in trenches complete all as specified and as directed. Note :- (i) CI spare parts shall be measured and paid separately under relevant items. (ii) Excavation and earth work shall be measured and paid separately under relevant items.
200 mm bore
150mm bore
100mm bore
80 MM bore
All as per items No - 1 above but DI pipe class K-9 lines of the following size:-
200 mm bore
150 mm bore
100 mm bore
80 MM bore
Supply and fix in repair CI/DI (Cast Iron/Ductile Iron) fittings like collar joints,tees, bends equal/reduced of size 150/100/80 mm bore complete all as specified and as directed.
All as per items No - 3 above but for 200 mm bore size.
S&F in repair rubber tyton/ Rubber gasket joint for DI/CI pipe for spigot & socket pipe of following sizes complete all as specified and as directed.
200mm bore
150mm bore
100mm bore
80mm bore
S&F in repair CI sluice valve, flanged of class PN 1.6 non raising type with stainless steel spindle supplied and installed complete of the following sizes:-
200mm bore
150mm bore
100mm bore
80mm bore
S&F in repair Non Return valve, flanged of class PN 1.6 supplied and installed complete of the following sizes :-
150 mm bore
100 mm bore
Cutting CI/DI pipes of following sizes and reducing to required length before laying pipes in position for insertion of new pipes in replacement/new tees, branches etc complete. Burning out of lead/tyton joint will be measured & paid separately.
200mm bore
150mm bore
100mm bore
80mm bore
Supply and laying in repair GI tubing medium grade of following sizes incluidng GI fittings like sockets, elbow, bends, tees , union, short pieces etc. laid in trench including taking down/out old unserviceable complete all as specified and as directed :- (Note:- Earth work will be measured & paid separately.)
80mm bore
50mm bore
40mm bore
25mm bore
20mm bore
15mm bore
All as per items No 9 above but for laid/fixing in floor/wall/ceilling etc.of following size:-
50 mm bore
40 mm bore
25 mm bore
20 mm bore
15 mm bore
S&F in repair Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed:-
50mm size.
40mm size.
25mm size.
20mm size.
15mm size.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.5m deep for laying pipe and getting out in soft/loose soil complete all as specified and directed.
Returning filling in soft/loose soil including spreading leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for Cement concrete (1:3:6) type C1 using 20mm grade stone aggregate necessary form work fair finishing to exposed surface complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving, plinth protection n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Testing of Bore well water/RO water/Narmada water to analysis the following parameter as per IS 10500:2000 through Govt. approved agency:- a) Physicochemical parameters of water / eflluent sample b) Bactoriological test of water sample. c) Metals (Expect Hg, As & Se). d) Pesticides. Note:- Water sample for testing shall be arranged by the contractor.
M&L for Lifting of submersible pump set 30/45 HP with column pipe of size 80/100 mm bore dia and connecting the column pipes after cleaning of threaded portions and replacement of worn out nuts, bolts attached WR pump set & pipe & coupling lowering the submersible pump with column pipes carefully and put into operation complete all as specified and as directed. Note : Replaced of column pipe will be measured and paid under respective items here in after.
Lifting of submersible pump set 7.5/15/30 HP fixed in underground sump 50000/100000 Gallon capacity with dismantling submersible pump complete with electrical, gasket for flanged pipes, replacement of worn out nuts, bolts attached and put into operation complete all as specified and directed.
Lifting of submersible sweage pump set of capacity 3.5/7.5/12.5 HP, from installed at sweage well/lifting well at underground sump capacity with dismantling submersible pump complete with electrical, gasket for flanged pipes, replacement of worn out nuts, bolts attached and put into operation complete and installed the same its own positins after repair/service the same all as specified and directed.
Servicing, testing & commissioning of the 45/50 HP submersible pump motor including rewinding with super enameled copper wire, replacement of neck rings, sleeves bushing, seal complete all as specified and directed.
All as per item No. 20.00 above but 30.0 HP
All as per item No. 20 above but 15.0 HP
All as per item No. 20.00 above but 7.5 HP
All as per item No. 20.00 above but 2.5/3.5 HP sweage motor
All as per item No. 20.00 above but 12.5 HP sweage motor
All as per item No. 20.00 above but centrifugal pump of capacity 7.5 HP
M&L for taking out complete pump & motor unit from installed position and rewinding the motor 1.5/2.0 HP capacity, Single/three phase, 50 Hz refixing the same at site complete all as specified and as directed.
All as per item No. 21.00 above but 1.0/0.5HP
M&L for rewinding of booster pump 2 HP capacity, three phase, 50 Hz monoblock /coupled centrifugal pump with super enamel copper wire of existing guage with and including replacement of bearings and refixing the same at site complete all as specified and directed.
M&L for Overhauling, testing & commissioning of the 45/50 HP submersible pump with replacement of impeller, rotor, bearing and minor spares complete all as specified and directed.
All as per item No. 24.00 above but 2.5/3.5 HP sweage pump
All as per item No. 24.00 above but 12.5 HP sweage pump
All as per item No. 24.00 above but 15/30 HP
All as per item No. 24.00 above but 7.50 HP
All as per item No. 24.00 above but centrifugal pump of capacity 7.5 HP
M&L for taking out complete pump & motor unit of capacity 1.5/2.0 Hp from installed position overhauling the pump unit and replacement of bearings and refixing the same at site all as specified and as directed.
All as per item No 25.00 above but 1.0/0.5HP
M & L for serviceing/repair of blower with motor and compressor unit of capacity 15.0 HP installed at STP. Overhauling the blower unit and replacement of bearings/any other spare/asscessories and refixing the same at site after repair complete all as specified and as directed.
All as per item No 27.00 above but 3.5/5 HP
S&F in repair of butter fly valve of size 150 mm dia, PN 1.6, operating angle 90 degree connected with out let of over head tank includes accessories like actuator with suitable size mounted type bracket including control limit switches for open and close condition and splash proof enclosure by oiling, greasing and setting of its machinism as per norms complete all as specified and directed by Engr in Charge.
All as per item No 28 above but 100 mm ida
S &F in repair MS ERW Pipe of 80 mm dia complete all as specified and directed.
Cleaning of mud inside bore through pressure machine on hired basis from local market as per direction of Engineer in charge
Supply and fixing in repair UPVC column pipes both ends threaded of 80 mm bore dia heavy duty (each pipe of 3 meters) long as per site requirement complete all as specified and as directed incl Upvc column pipe assecssories complete as per site requirement.
S&F in repair flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 16 Sqmm all as required at site and as directed by Engr in charge.
All as per item No. 33.00 above but 10 sqmm size
All as per item No. 33.00 above but 6 sqmm size
Cleaning of over head RCC reservoir top domb (18 meter) from GL with bleaching powder/non toxic solution throughly including removal of sand, clay silt, or any other foreign material from inside the reservoir of capacity 50,000 gallon and applying one coat of lime coating inside the tank and making date of cleaning and capacity of reservoir complete (note:- cleaning should be done once in six month ) all as directed.
All as per item No 34.00 above, but semi underground sump of capacity 10000 gallon.
All as per item No 34.00 above, but semi underground sump of capacity 50000 gallon.
All as per item No 34.00 above, but semi underground sump/SWT of capacity 100000 gallon.
Dismantling of damage/broken valve chamber and M & L for valve chamber made out of brick work of internal size 1200 x 1200 x1200 mm in cement mortar 1:4 including plaster and providing of valve chamber cover made out with MS sheet of 3mm thick with 40 x40x6mm size angle iron frame duly grouted to wall and painting to steel work wilth two coat of synthetic paint over one coat of red oxide primer and locking arrangement complete including earth work etc complete all as specified and directed.
All as per item No 35 above but of 900 x 900 x 900 mm in size.
All as per item No 35 above but of 600 x 600 x 600 mm in size.
M&L for testing/servicing/cleaning/maintenance of Fire Alarm system including panel, detector, sounder call point etc. installed at various locations and making it serviceable complete all as directed by Engineer - in - charge. Note:- Spares required for replacement if any shall be measured and paid saperately.
Replacement of 2 -zone Fire Alarm Panel
Replacement of Photoelectric Smoke Detector
Replacement of Manual call point
Replacement of Fire Alarm Sounders / Sirens Electronic type Horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB with 500 mtr range.
Replacement of addressable electronic sounder cum strobe/flasher
Replacement of Heat Detector
Replacement of Magnetic door switch
Replacement of Hose reel drum 30m
Replacement of Flanged stand post CI of 80mm dia 1.5m height
Replacement of Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted with one coat fire red out side and brilliant white inside yard.
Replacement of sealed battery 12 Volts 7 AH
Cutting/Trimming and uprooting unwanted plants/grass including levelling of soil around the water supply installation area etc complete all as specified and directed by Engr- in- Charge.
Supply & Fix in repair of existing old US, single phase preventor, 3 phase of type ESP-2, volt 415 complete all as directed by Engineer-in-charge.
Testing of STP water to analysis the following parameter as per IS 10500:2000 through Govt. approved agency:- (a) BOD (b) COD (c) TDS (d) TSS (e) Dissolved Oxygen (f) Residual Chlorine (g) PH Note:- Water sample for testing shall be arranged by the contractor.
Supply and fix in repair of fire hydrant valve type A (single head outlet) of 80 mm dia of size conforming to IS 5290 complete all as specified and directed by Engr-in-charge.
S&F in repair of 80 mm dia hydrant spindle alongwith wheel complete all as directed and specified by Engr-in-Charge.
Disconnecting and taking out including fault finding and replacement of old unserviceable MCB / MCCB (of any size and capacity) from any location and connection with existing electrical lines including testing and servicing of Starter Panel on completion complete all as directed by the Engr - in - Charge. Note :- MCB / MCCB required for replacement will be measured and paid separately under respective items of Schedule'A' as "supply only.
Supply and fix in repair electronic thermal timer type GT 100 (suitable for operating voltage of 500 Volts, 50 Hz for 3 - 30 secs), complete all as directed by the Engr-in-Charge. Make : L&T or equivalent as approved by GE.
Material & Labour in replacement the following items in UG sump panel for Submersible pump complete all as specified and directed
S&F in repair Contactor ML MNX 32 amp , three pole complete all as specified and directed. (Make- L&T or equivalent as approved by GE).
S&F in repair PVC copper stranded cable , single core of size 6 sqmm complete all as specified and directed.
M&L for rewinding of ATS transformer fixed in Starter Panel for 45 to 60 HP pump 440 volt, tap 60 to 80% complete all as specified and directed.
Supply only of MCCB 4 pole, 16 KA of rating 125 Amp.
Supply only of MCCB 4 pole, 16 KA of rating 63 Amp
S & F in repairs GI union fitting 50/40 mm dia medium gde union complete all as specified and directed.
All as per item No 50.00 above but socket/nipple/elbow/reducer /tee etc complete all as specified and directed.
S & F in repairs GI union fitting 25/20 mm dia medium gde union complete all as specified and directed.
All as per item No 52.00 above but socket/nipple/elbow/reducer /tee/end cap etc complete all as specified and directed.
S & F in repairs GI union fitting 15 mm dia medium gde union complete all as specified and directed.
All as per item No 54.00 above but socket/nipple/elbow/reducer /tee end cap etc complete all as specified and directed.
Supply and fix in repair 3 pole power contactor type MNX 70 confirming to IS/IEC 60947-4-1 range 9 Amp -650Amp, AC-3, Aux contact 2 NO-2NC 415 Volts, 50 Hz, complete all as specified and directed by the Engr-in-Charge. Make : L&T or equivalent as approved by GE.
All as per item No 56 here in before but MNX 95.
All as per item No 56 here in before but MNX 110.
All as per item No 56 here in before but MNX A1.
All as per item No 56 here in before but MNX A2.
M& L in repair for gland packing of centrifugal pump installed at area A ,B & C and filling oil to stop leakage water complete all as specified and directed.
S&F in repair rubber coupling of centrifugal pump set complete all as specified and directed by Engr-in-Charge.
S & F in repair UPVC pipes of dia 20 mm outer dia schedule 40,confirming to ASTM, fixed complete to walls, ceilings or in floors/ in trench etc. complete all as specified and directed
All as per item No 59.00 above but 25mm bore
All as per item No 59.00 above but 40 mm bore
All as per item No 59.00 above but 50 mm bore
All as per item No 59.00 above but 75 mm bore
All as per item No 59.00 above but 140 mm bore
Supply, installation, testing and commissioning of GI pop-up sprinklers of HT 40 G Q = 900 litres/ Hour, PD = 18000 litres/ Hour, 2 nozzle operate one time, 5mm preciption one hour operation time as per design and drawing with connected accessories including taking down complete all as specified and directed as per data sheet.
Comprehensive maintenance/servicing and testing of RO plant of capacity 1500 LPH including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set so as to supply qualitative water at permissible level of TDS. Note:- (a)Spares required for replacement will measured and paid separately under respective items here-in-this schedule. (b) The rate quoted by the tenderer includes cost of maint / servicing of above said plant once in a period of 30 days till the date of completion of work. (c) Rate inclusive of replacement of parts day during currency of contract as and when directed by Engineer-in-Charge. (d) Servicing should be done by OEM/authorized agency and not by any local mechanic (e) Contractor shall be produce all purchase voucher and test certificate before submitted RAR.
All as per item No 61.00 above but of plant capacity 600 LPH
All as per item No 61.00 above but of plant capacity 200 LPH at 47 SU
All as per item No 61.00 above but of plant capacity 200 LPH at Hajipur
All as per item No 61.00 above but of plant capacity 50 LPH at MES complex
Supply only sediment filter as existing for 50 ltr RO plants. Make:- Aqua Guard/Eureka Forbes/ION Exchange or equivalent as approved by GE.
Supply only RO membrane as existing for 50 Ltrs RO plant. Make:- Aqua Guard/Ureka Fobes/ION Exchange or equivalent as approved by GE.
Supply only RO membrane housing as existing 50 lts RO plant.
Supply only carbon filter for 50 ltrs RO plant Make-Aqua Guard/Eureka Forbes/Ion Exchange or equivalent as approved by GE.
Supply only low pressure /High pressure DC switch for 50 RO plant.
Supply only stainer for 50 Ltrs RO plant.
Supply only solenoid valve for 50 ltr RO plant. Make:- Aqua Guard/Eureka Forbes/ION Exchange or equivalent as approved by GE.
Supply only booster pump 48V DC suitable for 50 Ltrs RO plant.
Supply and fixing in repair RO membrane of size 8040 suitable for 1500 LPH plant including all fixing arrangements complete all as specified and as directed by Engr-in-Charge. Make: Aqua Guard/Eureka Forbes/ION Exchange or equivalent as approved by GE.
Supply and fix in repair conductivity meter with sensor for RO plant complete all as specified and directed
Supply and fix in repair only ultra violet (UR) system set for RO plant complete all as specified and directed
Supply and fix in repair membrane connector complete all as specified and directed
Supply and fix in repair membrane connector end cap 8" complete all as specified and directed
Supply and fix in repair 'O' ring size 100 mm for RO membrane complete all as specified and directed
Supply and fix in repair low pressure switch spring actuated type, 0.4-4Kg/cm2 range complete all as specified and directed
Supply and fix in repair high pressure switch spring actuated type, 0.4-4Kg/cm2 range complete all as specified and directed
Supply and fix in repair vessel for RO plant size 13'X54" complete all as specified and directed
Supply and fix in repair following spare parts 200/600/1500 Ltr/Hour capacity RO plant complete all as specified and directed
Sendiment filter
Sand suitable for RO plant
RO membrane of size 4040
Resin
Carbon media
Anti Scalant Chemical
Filter Housing
25 mm bore multipart valve for RO plant.
PVC Flexible pipe as per site requirement
RO Membrane housing
Pressure switch
Strainer
Dechlorination chemical
Pressure gauge 0-7 Kg/Cm2 dial size 65 mm
Pressure gauge 0-40 Kg/Cm2 dial size 105 mm
Needle valve size 15 mm for RO
Ph chemical for RO plant
Salt for charging resin for RO plant
Solium bi meta sulphite
Solenoid valve
TDS Scale
15mm ball valve.
Orthotodiline reagent solution in 500 ml bottle
Pressure tube as per site requirement
MS Angle duly painted with black colour for framing of Spare parts
UPVC Gate Valve 25 mm dia
PVC PVC plastic flexible Crackproof 0.75 inch pipe
Supply only Sodium hypochlorite solution 60-80 GPL in brand packed containeer with mention of CML NO and expiry date complete all as specified and directed.
Supply only Sodium Hypochlorite (Granules Forms) having 60 % to 70% available chlorine granules packed in 40 kg to 50 kg plastic drum complete all as specified and directed.
Servicing and calibration of digital water flow meter (make- Adept) fixed on DI pipe line 200 mm dia at 47 SU & 15 BRD A/F Wadsar complete all as specified and directed.
M&L for rectification of leakage from GI 50 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 50 mm bore medium grade connecting with old line by providing necessary fitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete all as specified and directed.
All as per item No. 80.00 above but 40 mm bore.
All as per item No. 80.00 above but 25 mm bore.
All as per item No. 80.00 above but 20 mm bore.
All as per item No. 80.00 above but 15 mm bore.
M&L for rectification of leakage from 80/100/150 mm size bore CI/DI pipe line by cutting and removing old lengh of pipe and inserting new pipe of same size connecting with old line by providing necessary fitting such as tyton joints,gasket,fittings including all necessary earth work for connecting complete all as specified and directed. Note (For item Ser No 80.00 to 81) - 1. Earth work will be measured and paid separately. 2. Quoted rate should be included up to one RM unit length.
M&L in replacement of existing damaged chamber cover with new 3mm thick MS Sheet cover fixed on 40mmx40mmx6mm thick angle iron frame embedded in PCC coping with locking arrangement and mild steel surface with two coats of red oxide primer etc. complete all as specified and directed.
M & L for cleaning and removal of all scale,dirt,mud and any foreign material and removing accumulated silt etc from lifting well by means of sewer cleaning machine complete all as specified and directed by Engr-in-Charge.
S&F in repair of rotational moulded water storage tank 5000 ltr capacity double layer (cylindrical /vertical with closed top) hoisted and fixed in position complete all as specified as in SSR Part-I.
All as per item No 84.00 above but 10000 litre capacity tank complete.
Cleaning of over head tank of PVC with bleaching powder/non toxic solution throughly including removal of sand, clay silt, or any other foreign material from inside the tank of capacity up to 5000 Ltr and making date of cleaning and capacity of tank complete all as specified and directed.
M&L for preparation of old pipe line of DI or GI surfaces of any description over of size 80/100/150 mm bore applying two coats of synthetic enamel paint over a coat of red oxide primer complete with showing arrow in water flowing direction in white colour complete all as specified and directed
M&L for painting the surfaces of pump set with mounting accessories of capacity 5 to 30 HP applying one coats of synthetic enamel paint with existing color complete all as specified and directed.
All as per item No 88 but for upto 3.5 HP
Supply, Installation, Testing and Commissioning in repair of 3 phase fully automatic star-delta starter panel MU-G 20 suitable for 15 HP submerseabile pump set including single phase preventor, over load protection etc. including connecting upto LT panel complete all as specified and directed by Engr In Charge.
All as per item No 90 above but MU-G 40
S&F in repair Ball valves of size 15 mm bore dia of pipe, high pressure, wiwth polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S & F in replacement belt of existing size and length installed at STP air blower complete all as specified and as directed.
S & F in replacement pig lead and lead wool for lead joint of CI pipes installed bottom OHT and various locations complete all as specified and as directed.
M&L in replacement of UG sump ladder of existing dimensions made of angle iron frame incl paintings steel surface of same with two coats of red oxide primer etc. complete all as specified and as directed.
M&L in replacement of Sand Pebble Media complete all as specified and as directed.
M&L in replacement of Carbon Media complete all as specified and as directed.
M&L in replacement of MBBR Media complete all as specified and as directed.
M&L in replacement of Tube settler media complete all as specified and as directed.
M&L in replacement of transmission oil for STP air blower complete all as specified and as directed.
S & F in repair UPVC ball valves, 140 mm complete all as specified and as directed.
S & F in repair UPVC valves, 75 mm complete all as specified and as directed.
S & F in repair UPVC ball valves, 50 mm complete all as specified and as directed.
S & F in repair UPVC ball valves, 40 mm complete all as specified and as directed.
S & F in repair UPVC ball valves, 25 mm complete all as specified and as directed.
S & F in repair UPVC ball valves, 20mm complete all as specified and as directed.
Fixing only tubes, any grade to walls and ceilings or laying in floors/trench complete for following size :- Note :- (i) GI/CI pipe will supplied by Dept as schedule "B" free for fixing only. (ii) Earthwork will be paid under respective item of BOQ. (iii) All measurements, whether 'laid complete', fixed complete' 'laying only' or fixing only' shall be net. The rates for 'laying only' or fixing only' include for labor, tools and plant and all tube necessary fittings"
40 mm bore
25 mm bore
20 mm bore
15 mm bore
JIYA CONSTRUCTION
Paliwal Construction Company
divyarsh entrprise
ARTI CONSTRUCTION
DIGNATION ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .