Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹14.8 L Quoted ₹15.4 L | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED |
| 2 | L2₹16.8 L+₹1.4 L (8.80%)Rejected-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹16.8 L+₹1.4 L (8.80%) | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 3 | L3₹17.1 L+₹1.7 L (11.0%)Rejected-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹17.1 L+₹1.7 L (11.0%) | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 4 | Rejected-Technical 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | - | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
5 Sept 2024, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR REPLACEMENT AND MAINTENANCE OF REFRIGERATOR DESERT COOLERS WATER COOLERS AIR CONDITIONERS DEEP FREEZERS CEILING FAN EXHAUST FANS WALL MOUNTING FANS GEYSERS AND ALLIED WORKS AT MIL STN DHRANGADHRA
2024_MES_664062_1
GE(A)/GNR/TOKEN/30 of 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMETNS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹32,000
Yes
2 Jan 2025
5 Jul 2024
12 Sept 2024
5 Jul 2024
5 Sept 2024
19 Jul 2024
5 Jul 2024 - 17 Jul 2024
Amount
Taking down and Refixing up carefully 1.5 ton window or 1.5/2 ton split type AC after checking of electric wiring and parts , cleaning of unit, lubrication of motor, capillary, filter & servicing at existing position/location complete all as specified and directed. Note:- (i) Compressor, capacitor, starting relay, overload protection shall be separetely measured and paid. (ii) The rate quoted are deemed to include cost of soldering/brazing work if required at site.
S&F, in repair, Indoor unit AC Swing motor blades (replaced with original company of same make as per existing), suitable for working on single phase, 50 HZ AC , 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Indoor unit AC blower fan motor (replaced with original company of same make as per existing), suitable for working on single phase, 50 Hz AC supply, 1.5/2 Ton type split AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Indoor unit AC blower fan bush (replaced with original company of same make as per existing), suitable for working on single phase, 50 Hz AC supply in split type AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Indoor unit AC Cooling condenser (replaced with original/as per existing), suitable for working on single phase, 50 Hz AC supply, 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Indoor unit AC Display unit (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Remote with PCB Circuit of 1.5/2 Ton capacity split ACs (replaced with as per existing), suitable for working on single phase, 50 HZ AC supply in split type AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC Fan motor blade of suitable size (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC copper coils of suitable size (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply , 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC insulation tubing/cover as per existing tubing tickness of 6 feet lenght For 1/4" & 1/2" size of copper coils(replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, Outdoor unit condenser fan motor of suitable size (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC heat condenser coil of suitable size (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company, new compressor of same make as per existing) suitable for Operation on single phase, 50 HZ AC supply for 1.5 ton split type AC including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC Compressor capacitor of suitable capacity (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply 1.5/2ton split type AC with electric connection, testing complete all as specified and directed.
M&L, in repair, Outdoor unit AC Gas valves of suitable size (replaced with original company of same make/as per existing),For 1.5/2 Ton split type AC with all conecting accessories, testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC power relay contactors of suitable capacity (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
M&L for refrigerent charging with R 22/R 134/R 410 for window AC of capacity 1.5 Ton and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L for refrigerent charging with R 22/R 134/R 410 for split type AC of capacity 1.5 & 2 Ton and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company, new compressor of same make as per existing) suitable for Operation on single phase, 50 HZ AC supply for 2 ton split type AC including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed.
S&F,in repair, Running capacitor of 36 MFD capacity for 1.5/2 ton split type AC suitable operation on 230 Volt, 50 Hz complete all as specified and directed.
S&F,in repair, Running capacitor of 45 MFD capacity for 1.5 Ton window/split type AC suitable operation on 230 Volt, 50 Hz complete all as specified and directed.
S&F,in repair, Running capacitor of 60 MFD capacity for window/split type AC suitable operation on 230 Volt, 50 Hz complete all as specified and directed.
S&F, in repair, Heavy duty ODU (outdoor unit) Stand/installation bracket kit with brackets, fasteners, nuts and washer for 1.5/2 ton split type AC complete all as specified and directed.
M&L, in repair, starting relay of window/Split type A/C, 1.5 to 2 Ton capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, Thermostate switch suitable for window/Split type A/C, 1.5 to 2 Ton capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, Sensors for all model type AC.s, including making necessary electric connections complete all as specified and directed.
S&F, in repair, overload protector for split type AC of 1.5/2 Ton capacity complete all as specified and directed.
M&L, in repair, copper piping of 1/2" & 1/4" size , wiring between Indoor & Outdoor for 1.5/2 ton split type AC including all necessary connecting accesssories complete all as specified and directed.
S&F, in repair, indoor unit DC motor (replaced with original company of same make/as per existing), of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity inverter type Split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, DC indoor circuit (replaced with original company of same make/as per existing), of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity inverter type Split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, inverter outdoor unit circuit (replaced with original company of same make/as per existing), Of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity inverter type Split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, inverter outdoor unit DC compressor (replaced with original company of same make/as per existing), Of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity INVERTER Type Split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, inverter outdoor unit sensor (replaced with original company of same make/as per existing), Of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity INVERTER Type Split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/8 HP (165 to 210 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/6 HP (265 to 310 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair,Evaporator of 165/180L Capacity (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/8 & 1/6 HP (180 to 310 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 310/320 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
M&L, in repair, starting relay of Refrigerator 1/8 to 1/6 HP capacity including making necessary electric connections complete all as specified and directed.
S&F, in repair, overload protector of Refrigerator and Deep freezer 165 Ltr to 320 Ltr complete all as specified and directed.
S&F, in repair, Deep freezer condenser (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200/310/320 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, Deep freezer condenser fan motor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200/310/320 Ltrs capacity including making connection, electric connections and testing complete all as specified and directed.
S&F, in repair, Deep freezer cooling fan of 35x35x10mm (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200/310/320 Ltrs capacity including making connection, electric connections and testing complete all as specified and directed.
M&L for refrigerent charging with R-134a for Deep Freezer of capacity 200 Ltr to 320 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L for refrigerent charging with R-600a for Refrigerator of capacity 165 Ltr to 320 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in water cooler of 40/80 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
M&L, in repair, starting relay of water coolers 40/80 Ltr capacity including making necessary electric connections complete all as specified and directed.
S&F, in repair, overload protector of water cooler up to 120/150 Ltr complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for Water Cooler of capacity 40/80 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L, in repair, Thermostate suitable for water cooler up to 120 ltrs capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, Thermostate suitable for Refrigerator & deef freezer up to 320 ltrs capacity including making necessary electric connections complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 4.0 MFD complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 6.3 MFD complete all as specified and directed.
S&F, in repairs, water lifting submerssible pump (ISI Marked) suitable to operate on 230V AC supply of desert cooler and connecting electically, complete all as specified and directed.
S&F, in repair, fan motor (ISI Marked), 1/6 HP, 230 volt single phase of existing desert cooler with fixing clamps, complete all as specified and directed
S&F, in repair, fan motor blade, 230 volt single phase suitable for existing desert coolers with fixing clamps, nuts, bolts, washers etc. complete all as specified and directed
S&F, in repair, water storage tank of minimum size 0.8m x 0.8m x 0.2 (L x W x H), steel body, fabricated out of CRCA sheet of 0.6mm thick duly painted with two coats of synthetic enamel paint suitable for existing desert cooler complete all as specified and directed
S&F in repair, PVC distributer and PVC elbows suitable for water distribution assembly of desert coolers complete all as specified and directed.
S&F, in repair, grass pads, superior quality, size 60x45 cm (approximate), complete all as specified and directed
S&F, in repair, PVC flexible pipe 12mm dia suitable for submersible pump of desert cooler complete all as specified and directed.
S&F, in repair, PVC insulated, sheathed cable 3 core, 1.5 Sqmm, multistandard copper conductors minimum length 2 mtr for Desert Cooler, water coolers/ refrigerators as main cord with 5A, 3 pin top complete all as specified and directed.
Taking down of ceiling fan 1200/1400 mm sweep from existing position/hook, dismantling blades deposite to store and removing fan cleaning, servicing or re-fixing on same position after complete all as specified and directed.
De-assembling (opening) of the ceiling fan, 1200mm/1400mm sweep for repair, removing existing burnt winding, rewinding as per existing winding the same gauge and weight with super enameled copper winding wire of appropriate gauge, slot insulation, heat varnishing, greasing and re-assembling including replacement of split pin and flexible twisted copper cable of 23/0.0076 gauge, testing complete all as specified and directed. Note:- (i) Contractor shall collect the Ceiling fan for repair from Store Yard/site of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Where ever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only capacitor of 2.5 Mfd suitable for 1200/1400 mm sweep ceiling fan.
Supply only ball bearing suitable for 1200mm/1400mm sweep ceiling fan.
Supply only gun metal bush suitable for 1200/1400mm sweep ceiling fan of appropriate make.
S & F, in repair, capacitor of 2.5 Mfd suitable for 1200 mm/1400mm sweep ceiling fan.
S&F, in repair, PVC canopy set (Upper & Lower) suitable for ceiling fans complete all as specified and directed.
S & F in repair,ceiling fan down round metal rod/pipe of lenghts of one feet suitable for 1200 mm/1400mm sweep ceiling fan.
S&F, in repair, MS hanging clamp with rubber bush, bolts, nuts & washer with split pin suitable for ceiling fan complete all as specified and directed.
M & L Painting of ceiling fans complete, in situ/in store with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning/removing existing paint and all dust etc.
S&F in repair, PCB circuit complete for BLDC fan as per fan manufacturer make complete all as specified and as directed by Engr-in-Charge
Taking down exhaust fan metal body of size 200/230/250/300/380/450 mm sweep from existing position, cleaning, servicing and re-fixing on same position complete all as specified and directed by Engr-in-charge.
De-assembling (Opening) of exhaust fan 200/230/250/300 mm sweep for repair, removing existing burnt winding, rewinding as per existing winding gauge & weight with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling, refixing, testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store/Site Yard of AGE E/M and Refix repaired fan on the location given by Engineer-in-charge. (ii) Where ever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
De-assembling (Opening) of exhaust fan 380/ 450 mm sweep for repair, removing existing burnt winding, rewinding as per existing winding gauge & weight with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling, refixing, testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store/Site Yard of AGE E/M and Refix repaired fan on the location given by Engineer-in-charge. (ii) Where ever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only capacitor of 4.0 Mfd suitable for exhaust fan.
Supply only ball bearing suitable for 200/230/250/300mm sweep exhaust fan complete.
Supply only ball bearing suitable for 380/450 mm sweep exhaust fan complete.
Supply only gun metal bush suitable for 200/230/250/300mm sweep exhaust fan complete.
Supply only gun metal bush suitable for 380/450mm sweep exhaust fan complete.
M&L for preparation of surfaces of exhaust fan of size 200/230/250/300/380/ 450mm including blade, frame/louver and apply one coat of synthetic enamel paint with spraying after taking down in respective items all as specified and directed by Engg-in-change.
Taking down of exhaust fan PVC type 200/250/300mm sweep for repair, removing existing burnt motor and replacement of motor/fan blade etc., refixing, testing complete all as specified and directed. Note : Where ever required the fan motor/fan blade shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only PVC exhaust fan motor suitable for 200/250/300mm sweep
Supply only PVC exhaust fan blade suitable for 200/250/300mm sweep
S&F exhaust fan, 200 mm sweep, 1200 rpm, PVC body, AC single phase, 230 volts, 50 Hz with louvers including connecting up with ceiling rose complete all as specified and as directed.
S&F exhaust fan, 250 mm sweep, 1200 rpm, PVC body, AC single phase, 230 volts, 50 Hz with louvers including connecting up with ceiling rose complete all as specified and as directed.
Taking down/Disconnecting carefully water storage type water heater of 25/50 ltr cap of any make, disconnecting electric connection and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by chemical compound including soldering, brazing if required, Re-assembling and re-fixing the geyser after cleaning & servicing at existing position/location complete all as specified and directed. Note:- (i) Heating element, thermostat, air release valve, safty valve, indicating lamp and syphone assembly shall be measured and paid under relevant items as "Supply Only". (ii) The rate quoted are deemed to include cost of soldering/brazing work if required at site.
Supply only heating element of 1.5 KW with circular or triangular base suitable for existing entry of geysers of any make complete all as specified and directed.
Supply only heating element of 2.0 KW with circular or triangular base suitable for existing entry of geysers of any make complete all as specified and directed.
Supply only thermostat assembly for existing geysers make, tempetrature setting up to 85 degree centigrade, ISI marked complete all as specified and directed.
Supply only indicating lamp suitable for existing entry of geyser complete all as specified and directed.
S&F, in repair, inlet/outlet (cold& hot) pipe of 15mm bore 400mm long, PVC connection, high density suitable for temperature upto 100 degree complete all as specified and directed.
S&F, in repair, inlet/outlet (hot & cold) pipe of 15mm bore 600mm long, PVC connection, high density suitable for temperature upto 100 degree complete all as specified and directed.
S&F, in repair, water storage type copper inner tank of 25 ltr capacity as per existing tank complete all as specified and directed.
S&F, in repair, water storage type copper inner tank of 50 ltr capacity as per existing tank complete all as specified and directed.
S&F, in repair, water storage type steel body outer tank of 25 ltr capacity as per existing tank complete all as specified and directed.
S&F, in repair, water storage type steel body outer tank of 50 ltr capacity as per existing tank complete all as specified and directed.
S&F, in repair, semi circular bottom cover plate of 25/50 ltr capacity geyser duly painted of appropriate make complete all as specified and directed.
S&F, in repair, Geyser syphon assembly (flange) made out of copper/steel as existing including heat resistance and leak proof gasket suitble for 25/50 ltrs capacity geyser all as specified and directed.
S&F, in repair, safty relief valve, as per existing of 25/50 ltr capacity geyser complete all as specified and directed.
S&F, in repair,pressure safty valve, as per existing of 25/50 ltr capacity geyser complete all as specified and directed.
S&F, in repair, glass wool superior quality around the water container as heat resistance upto full capacity complete all as specified and directed.
SURESH ELECTRICALS (BID ID -3086145)
Abhishek Enterprises (BID ID -3073339)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .