Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAdmitted-Finance NEAR RELIANCE PETROL PUMP RAMGARH CANTT 829122 DIST RAMGARH JHARKHAND | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L1 | Admitted-Finance | |
| 2 | L2₹22.1 L+₹1.9 L (9.42%)Admitted-Finance JHARKHAND | LOHARDAGA | JHARKHAND | 835302 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical 521 UBI ROAD SINGRAULI SINGRAULI SINGRAULI MADHYA PRADESH 486889 | SINGRAULI | MADHYA PRADESH | 486889 | - | Rejected-Technical Not submitted all relevant documents as per NIT |
| Sl No | Description | Qty | Unit | Rajneesh Electricals L1 | M/s Achal Electricals L2 |
|---|---|---|---|---|---|
| 2.00A)(i) Maintenance of East feeder 3.3KV OH line from Pundi 2.6MVA main sub-station to Bhuiyan Tola (3600 Mtrs. Span) by replacing damaged pole, damaged pin insulators, damaged disc insulators, damaged & rusted cradling and damaged bow stay, in view of coming monsoon session.(ii) Diversion of 1450 Mtrs. span of mentioned OH line for, easy & proper breakdown/preventive maintenance of OH line, to reduce overall span length by 700 Mtrs. and to spare 22 nos. of 11Mtrs. MS tubular poles from existing OH line.(iii) Erection of 2900 Mtrs. of rabbit conductor and 11no. earth-pits for earth continuity.(iv) Painting of all tubular poles including painting of cross arms and cross bracings and installation of anti-climbing device in above mentioned OH line of Pundi Project under Kuju Area | |||||
| 3.00 | Errection of tubular pole of length exceeding 10 M but not exceeding 12M in cement concrete 1:3:6 (1 cement:3 coarse: 6 graded stone aggregate 40 mm nominalsize) foundation including excavation & refilling etc as required | 26 | nos | 6,500 ₹1,69,000 Lowest | 7,150 ₹1,85,900 |
| 4.00 | Erection of All alluminium conductor of 7/1.96 to 7/4.0 mm dia and above including binding etc as required. 26 Span x 0.394 Kg/M (DOG) x 50 M x 3 wire. | 1,537 | kg | 150 ₹2,30,550 Lowest | 162 ₹2,48,994 |
| 5.00 | Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate ofsize 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle(20mm X 60 cm), 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundationincluding excavation and refilling and also with 0.6 m long braceof size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulleyfixed at one end of the brace as required. | 12 | nos | 4,800 ₹57,600 Lowest | 5,313 ₹63,756 |
| 6.00 | Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for claimping to the poles, 50 mm X 6 mm M.S. flals welded onone side to the channel iron and with bolts and nuts on the otherside for tying the cross arms together, including drilling holes forinsulator pins/fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. | 4 | nos | 4,150 ₹16,600 Lowest | 4,575 ₹18,300 |
| 7.00 | Supplying and erection of a sol of cross bracing FRL Same work for 11 KV over head line double polo structure having four membersfabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height comploto with 50 mm X 6mm M.S. flat iron clamps, bolts andnuts including drilling holes for insulator pins, bolts and nuts olc(as por drawing) and painting with primer and finish paint as required | 3 | nos | 6,200 ₹18,600 Lowest | 6,800 ₹20,400 |
| 8.00 | Erection of pole lop/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail PCC pole for 11/22/33 KV as required. 21 Cross arms + 5 Cross bracing | 26 | nos | 400 ₹10,400 Lowest | 450 ₹11,700 |
| 9.00 | Supplying and erection of 11 KV pin insulator complete with large steel head G I. pin, nuts, washers elc. as required. For replacement of damaged pins insulator in complete Overhead line | 40 | nos | 250 ₹10,000 Lowest | 274 ₹10,960 |
| 10.00 | Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanised insulator fittings, ball and socket typeand complete with galvanised strain clamps, bolts, nuts, washers etc, as required. For replacement of damaged disc Insulator in complete Overhead line | 36 | nos | 820 ₹29,520 Lowest | 900 ₹32,400 |
| 11.00 | supplying and erecting earth pit of minimum bore dia. 150mm size, approved make Safe Earthing Electrode consisting Pipe-In-Pipe technology as per IS 3043-1987 made of corrosion free G.I. Pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing as mentioned below: With 3 mtr. G.I. Pipes having outer pipe dia of 50mm having 80-200 micron galvanizing, Inner pipe dia. of 25mm having 200-250 Micron galvanizing, connection terminal dia.of 12mm in nominal soil with 50 kg (Two Bag) Back filling Compound. For Earth Continuity of 2900 Mtrs. span of 3.3KV OH Line from Pundi 2.6MVA main sub-station to Bhuiya Tola | 11 | nos | 13,150 ₹1,44,650 Lowest | 14,450 ₹1,58,950 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
15 Aug 2025, 6:55 pmClosed
SO(ENM)
GM UNIT KUJU
A)Maintenance of East feeder 3.3KV OH line from Pundi 2.6MVA main sub-station to Bhuiyan Tola under Pundi Project B)Renovation and maintenance of power supply with proper lighting conductor and earthing arrangements at 2 nos. weighbridges Karma OCP
2025_CCL_340953_1
GM (K)/EnM/eTender/25-26/113
Open Tender
Electrical and Maintenance Works
Item Rate
25 days
GM UNIT KUJU
2 documents required · 2 mandatory
₹30,000
18 Oct 2025
5 Aug 2025
16 Aug 2025
5 Aug 2025
15 Aug 2025
5 Aug 2025
5 Aug 2025 - 12 Aug 2025
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .