Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Annual Maintenance Contract for the AC System installed at all hospital buildings of IGM Hospital, including Agartala Government Dental College building, Agartala Phase-1
2024_CEPWD_47610_1
75/EE/DNIeT/MECH.DIVN/AGT/2023
Open Tender
Electrical Works
Works
365 days
AGARTALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹37,442
12 Dec 2024
24 Feb 2024
2 Mar 2024
24 Feb 2024
2 Mar 2024
24 Feb 2024
Amount
General Servicing of 1.5/2.00 TR capacity split AC machines in/c washing cleaning of (Indoor & Outdoor) units both by pressurised water by using Jet pump and servicing Jacket as per direction of the Engineer-in-Charge.
General servicing of 1.5 TR window type AC machines in/c washing cleaning by pressurised water by using Jet pump as per direction of the Engineer-in-Charge.
Leak testing of Condensing & evaporator unit for performance and pressure testing etc for 1.5/2.0 TR capacities split type AC's and repair with brazing as per direction of the Engineer-in-Charge.
Leak testing of Condensing & evaporator unit for performance and pressure testing etc for 1.5/2.0 TR capacities window type AC's and repair with brazing as per direction of the Engineer-in-Charge.
Charging fresh refrigerant gas for 1.5 TR/2.0 TR Capacity split type Ac's as per direction of the Engineer-in-Charge.
Charging fresh refrigerant gas for 1.5 TR Capacity window type Ac's as per direction of the Engineer-in-Charge.
Repairing & fitting fixing of blower motor of Ac's after rewinding in/c necessary replacement of bush, shaft etc with complete varnishing as per direction of the Engineer-in-Charge.
Providing, fitting fixing of Scroll motor of indoor unit of AC systems as per direction of the Engineer-in-Charge.
Replacement of running Capacitor as per direction of the Engineer-in-charge.
Replacement of Starting Capacitor as per direction of the Engineer-in-charge.
Providing & Fitting Fixing of PCB circuit as per direction of the Engineer-in-Charge.
Dismantling of Split /window AC machine's & storing at site as per direction of the Engineer-in-charge.
Re-installation of dismantled Split /window AC machine's as per direction of the Engineer-in-charge.
Providing and installation of new Dc fan motor of indoor unit by replacing old one as per direction of the Engineer-in-Charge.
Repairing of outdoor fan motor unit as per direction of the Engineer-in-Charge.
Repairing of PCB circuit of indoor unit as per direction of the Engineer-in-Charge.
Providing & fitting fixing of hermetically sealed condenser unit for 1.5 Tr capacities split type ac machines replacing old one as per direction of the Engineer-in-Charge.
Providing & fitting fixing of hermetically sealed condenser unit for 2.0 TR capacities split type ac machines replacing old one as per direction of the Engineer-in-Charge.
Providing and fitting fixing of Inverter compressor (1.5 TR) capacity Split type AC's as per direction of the Engineer-in-Charge.
Providing and fitting fixing of Inverter compressor (2.0 TR) capacity Split type AC's as per direction of the Engineer-in-Charge.
Charging fresh refrigerant gas for 1.5 TR/2.0 TR Capacity split type inverter Ac's as per direction of the Engineer-in-Charge.
Providing & Fitting Fixing of PCB Circuit of indoor unit of inverter AC (1.5/2.0 TR)(same brand with the machine to be repaired) as per direction of the Engineer-in-Charge.
Providing & Fitting Fixing of PCB Circuit of outdoor unit of inverter AC(1.5/2.0 TR)(same brand with the machine to be repaired) as per direction of the Engineer-in-Charge.
Providing & Fitting Fixing of indoor fan Motor as per direction of the Engineer-in-Charge.
Providing fitting Fixing of MS Platform for placement for condensing unit by using MS Angle of (50*50*5) mm size base plate /cradle with necessary nuts & bolts etc in/c painting , fitting fixing grouting by cement mixture as per direction of the Engineer-In-Charge.
Providing & fitting fixing of 1" PVC drain Pipe as per direction of the Engineer-in-Charge.
Providing, fitting & fixing of hermetically sealed reciprocating compressor for 2.0 TR capacity split type AC's replacing old one as per direction of the Engineer-in-Charge.
Providing, fitting & fixing of hermetically sealed reciprocating compressor for 1.5 TR capacity split type AC's replacing old one as per direction of the Engineer-in-Charge.
Providing fitting & fixing of hermetically sealed reciprocating compressor for 1.5 TR capacity window type Ac machines replacing old one as per direction of the Engineer-in-Charge.
Repairing of burnt Blower fan motor of Split AC (1.5/2.0 TR) outdoor unit as per direction of the Engineer-in-Charge.
Providing & Fitting fixing of following spare parts as per the direction of the Engineer-in-charge.
Capacitor 2.5 mfd
Capacitor 4.0 mfd
Capacitor 6.0 mfd
Capacitor 25 mfd
Capacitor 36 mfd
Capacitor 45 mfd
Capacitor 50 mfd
Capacitor (80-150) mfd
Providing & fitting fixing of Gas Charging valve (1/4") dia. as per direction of the Engineer-in-Charge.
Providing & fitting fixing of Gas Charging valve (5/8") dia. as per direction of the Engineer-in-Charge.
Labour charges for refrigerant gas Charging for Split /window AC's as per direction of the Engineer-in-Charge.
Providing for fitting fixing of different sizes of Hard drawn Pure copper pipe for suction and liquid line with installation and necessary wiring between indoor and outdoor unit etc. complete as per direction of the Engineer-in-charge.
1/4'' (6.35 mm) Or nearest Diameter as per manufacturers design.
3/8'' (9.5mm) Or nearest Diameter as per manufacturers design.
1/2'' (1.7 mm) Or nearest Diameter as per manufacturers design.
5/8'' (15.8 mm) Or nearest Diameter as per manufacturers design.
3/4'' (19.1 mm) Or nearest Diameter as per manufacturers design.
7/8'' (19.1 mm) HD pipe Or nearest Diameter as per manufacturers design.
1'' (22.2 mm) Or nearest Diameter as per manufacturers design.
1-1/8'' (28.5 mm) Or nearest Diameter as per manufacturers design.
1-1/4'' (31.75 mm) Or nearest Diameter as per manufacturers design.
1-3/8'' (34.9 mm) Or nearest Diameter as per manufacturers design.
1-1/2'' (38.1 mm) Or nearest Diameter as per manufacturers design.
1-5/8'' (41.3 mm) Or nearest Diameter as per manufacturers design.
1-3/4'' (44.45 mm) Or nearest Diameter as per manufacturers design.
2'' (50.8mm) dia. Or nearest Diameter as per manufacturers design.
2.48'' (63 mm) dia. Or nearest Diameter as per manufacturers design.
2.95'' (75 mm) dia. Or nearest Diameter as per manufacturers design.
3.54'' (90 mm) dia. Or nearest Diameter as per manufacturers design.
IMPERIAL COOLING SOLUTIONS
SHIV SAKTI REFRIGERATION
ASHIRBAD REFRIGERATION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_48401.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .