Tender Value
₹8.5 L
EMD Value
₹17,020
Closing Date
3 Aug 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, JPDCL, ED-Rajouri
Executive Engineer, JPDCL, ED-Rajouri
SITC FOR CREATION OF 63 KVA S/STN AT MRF KALAKOTE
2023_PDD_221630_1
EDR/34 of 2023-24 Dated 13.07.2023
Open Tender
Electrical Works
Turn-key
60 days
RAJOURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
EXECUTIVE ENGINEER, JPDCL, ED-RAJOURI
₹17,020
22 Aug 2023
14 Jul 2023
5 Aug 2023
14 Jul 2023
3 Aug 2023
22 Jul 2023
Amount
11 kV HT Line Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and then complete Erection, Testing and Commissioning as per REC/PDD Standard of
S.T Pole 8 mtrs long (410-SP15)
30 mm2 ACSR wsl Conductor
Galvanisied Channel V cross-arm with Top brackets and Clamps
Galvanisied Channel cross-arm/ Angle/ Flat including clamps and braces.
11 kv Pin insulators with pins (10KN)
11 kv Disc insulators with fittings (45 KN)
Cemment Bottoming 1:2:4 mix as per REC standard 0.5 cubic mtr per poles
GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete.
Al. Painting
Red Oxide
Anti Climbing Device with clamps
Danger Plates with clamps
Galvansied Nuts and Bolts of sorts
11/0.44 kV S/Stn Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and then complete Erection, Testing and Commissioning as per REC/PDD Standard of
63 KVA Transformer Level II , 11/0.433KV,3-Phase Distribution Transformer with Bimetallic Terminal Connectors ,Aluminium Wound and with LV Cable Box having detachable Aluminium Gland plate.
LT Distribution box for 63 KVA with MCCB for incomer and SFU's for outgoing Circuits.
S.T Pole 8 mtrs long (410-SP15)
Surge Arrester Station Type 9KV, 10 kA (Polymer Type)
11 KV Horn Gap Set, 3 Phase, 200 Amp
11 KV GO, AB Switch 3-Phase ,3-pole, 200 Amp, Vertical Type
Channel/Flate/Angle in shape of fabricated X-arms, Top bracket, Angle braces, clamps etc.
GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete.
PVC insulated stranded conductor FRLS type 1.1kv Grade Cable 185 mm sq with Thimbles
Wedge Connectors
LT Control Panel 440/220V
3.5 Core LT Cable 120 sqmm
11 kv Pin insulators with pins (10KN)
11 kv Disc insulators with fittings (45 KN)
Nuts and Bolts of sorts
Earthing of Sub-station ,excavation of earth pit of dia 650mm and depth 3000mm,installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5 mtr.long as per IS 1239.GI strip for neutrl earthing of size 25 mm*3 mm for connection of transformer body ,G.O set and lightening arrestor as per IS 2629/85,GI nuts and bolts ,refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. (Specification as per cost data)
Cemment Bottoming 1:2:4 mix as per REC standard 0.5 cubic mtr per poles
3 PH. 4 WIRE TRIVECTOR METER WITH CT
GI BARBED WIRE FOR Anti Climbing
Danger Plate
Al. Painting
Red Oxide
Sundry Items/POL
LT Line Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and then complete Erection, Testing and Commissioning as per REC/PDD Standard of
S.T Pole 8 mtrs long (410-SP15)
20 mm2 ACSR Squirrel Conductor
Shakle Insulator (16KN)
Mukky Clamps
Aluminium Jointing Sleeves
Cemment Bottoming 1:2:4 mix as per REC standard 0.45 cubic mtr per poles
Galvansied Stay set with 50x8mm stay clamp, guy insulator (02nos.) anchor plate (200x200x6mm) nut bolts, 2nos. Turn bukles, 1.80m long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Earthing Complete by G.I. Pipe 40mm or G.I. Rod 20mm 2.5mtr long through G.I. Strip
Anti Climbing Device with clamps
Red Oxide
Al. Painting
LT line spacer
Danger Plate
Nuts and Bolts of sorts
m/s surinder kumar sharma
Fazal Hussain
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .