Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.8 LAccepted-AOC | L1 | Accepted-AOC L1 - Lowest bidder | |
| 2 | L2₹76.5 L+₹3.7 L (5.06%)Rejected-AOC VILL DAKALA DIST PATIALA | L2 | Rejected-AOC L2 - Highest Bidder |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
1 Jul 2021, 12:00 pmClosed
Executive Engineer
Water Supply and Sanitation Division No.2, Partap Chowk, Metro Road, Ludhiana.
Providing bifurcation/ augmentation of piped Water Supply Scheme at Village Tibba, Block Dehlon, District Ludhiana. (Under NABARD RIDF-XXIII/JJM)
2021_WSS_66854_1
No.2532 dt.11.06.2021 (Tibba)
Open Tender
Civil Works
Item Rate
270 days
Ludhiana
Please refer Tender documents.
8 documents required · 8 mandatory
₹100
₹1.3 L
16 Nov 2021
12 Jun 2021
1 Jul 2021
12 Jun 2021
1 Jul 2021
12 Jun 2021
Amount
Tubewell
Drilling of 500mm dia bore with Reverse Rotary Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to site complete in all respect.
Drilling of 500 mm dia bore with Reverse Rotary Rig up to 150mtr. Depth BGL
1. Erection and dismantling of boaring plant including all arrangment for the transportation of the boaring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work. Plts for collection of water and water for drilling tubewell be arranged by the firm/ contractor at site at his own cost and levelled after the completion of work.
2. In payment of bore shall be made upto the bail plug plus margin(7 % of main bore drilling or as actual as per field requirement whihever is less) required for sustaining the main bore.
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
200mm nominal diameter (weight 33.6 kg per meter) 6.4mm thickness
Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest with SS socket to connect Stainer to Strainer Duly welded with suitable grade S.S welding electrode. to lower the strainer into tubewell bore.
200mm Steel Strainer (slot size 0.75mm) 6.30mm thickness.
Supplying, Fixing & lowering of Stainless Steel socket as per IS 8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore complete in all respect.
Supplying, lowering & fixing of M.S Special socket to connect S.S strainer to M.S pipe duly welded with suitable grade welding electrode complete in all respect.
Making electric logging of borehole with electronic well logger including cost of equipment at site etc. complete in all respects.
Supplying and fixing mild steel centering guides made out of 32mm X 6mm thick M.S bar complete in all respect
Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Supplying at site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/2003 with latest amendments. (to be paid as per actual length of pipe)
Supplying of tibba sand/ local sand over packing & clay seal upto G.L. below pipe assembly & bore including carriage complete in all respect. (As per IS: 2800-2019)
Supplying and fixing sanitary seal having rubber tight on housing pipe complete in all respect. (IS:2800-2019)
Supplying of clay to provide impervious layer in below pipe assembly & bore above gravel packing all including carriage. (IS:2800-2019)
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)
Supplying and fixing well cap having thread to fix on housing pipe complete in all respect.
200mm internal diameter
Supplying & fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
200mm internal diameter (weight 33.6 kg per meter) 6.40 mm thickness
Supplying & fixing of M.S. Clamp of size 150mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost of Nut & Bolts of suitable size complete in all respects.
Development and stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI
Development and stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, Uranium etc.)
Sterlization of Tubewell (As per IS:2800-2019)
Construction of One no. RCC OHSR 50000 ltr. Capacity with sill level not less 17.00 mtr. height upto 20.00 mtr. from formation level complete with external RCC stair case with landing slabs at each staging RCC roof , ventilator single main hole cover lightening conductor etc. complete as described in schedule No. 3. Providing and fixing D.I K-9 D/F expansion joints latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I/D.I/D/F sluice valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI double flanged pressure pipes DI K-9 horizontally as per IS 8329-2000 and latest duly ISI marked from bottom dome to duck foot bend and stretches up to2.75 mtr. as per detail specification , TMT steel & painting of all complete shall be included in cost & P/F aluminium ledder inside the OHSR complete in all respect as per specifications. The specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing ceiling preminum including providing and fixing automatic Electronic water level control device and construction of plinth protection around OHSR with masonry toe well with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling, including overflow scour haudi complete in all respects. ( including carrage of material of OHSR)
COST ESTIMATE OF PUMPING MAIN
Providing, Stringing out PVC pipe Trenches and laying the same in Trenches To correct alignment and gradients, Excavation, cutting. Jointing and testing, including back filling complete as per specifications.
110mm o/d PVC pipe 10 kg/cm 2
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Construction of Masonary Sluice Valve Haudies 0.9 X 0.9
Distribution System
Providing, Stringing out PVC pipes ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, including excavation cutting, Jointing, testing and back filling complete as per specifications for more than 3 mtr street width. (Mechanically)
PVC pipe 63mm o/d (6kg/cm2)
PVC pipe 75mm o/d (6kg/cm2)
PVC pipe 90mm o/d (6kg/cm2)
Providing, Stringing out PVC pipes ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, including excavation cutting, Jointing, testing and back filling complete as per specifications for Less than 3 mtr street width.(Manually)
PVC pipe 63mm o/d (6kg/cm2)
PVC pipe 75mm o/d (6kg/cm2)
PVC pipe 90mm o/d (6kg/cm2)
PVC pipe 160mm o/d (6kg/cm2)
Providing and Laying, Jointing, fixing, testing G.I. Pipe Lines B- Class, including cost of Specials such as tees, bends, sockets elbow etc. cutting, threading and testing in trenches in the ground complete.
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
PVC pipe 63mm o/d
PVC pipe 75mm o/d
Dismantling of cement concrete road and restoration in original condition as per Analysis A-25
Dismantling of metallic road with bituminous course 50 to 75mm thick C.C. 1:8:16
No. of cut 25 x 3 (width of road)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
CSR No. 28.27 (a)
Construction of Masonary Sluice Valve Chamber
Pump Chamber with Toilet
Construction of Pump Chamber size 3.05 m X 3.70 m including cost of gravel pit & electric wiring as per standard design. D-1-1 to D-1-4 & Complete in all respect.
Construction of 1 no. set of Toilet.
Pumping Machinery
Providing and installing of Submersible pumping set with pump, motor, panel board,submersible cable & column pipe complete 361 LPM, Head 63 mtr. & 10.00 HP moter with 4.00 mm 2 cable = 90mtr & 65mm column pipe = 36mtr.
Detail of Pumping Machinery
10.00 BHP (Motor with Pump)
Panel Board
Cable (Size/Cost) 4.00mm2= 90 mtr.
Column Pipe (G.I)( Size/Length) (65mm i/d=36mtr.)
C.I FITTING
Providing and installing 100 mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends & Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Drawings D-12 & D-17.
Development of Water Works
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8.
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8..
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7.
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3.
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 complete in all respects.
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-7.
Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing D-20.
Household Connections with Water meter
Providing Household connection laying, jointing, fixing testing MDPE pipes (as approved by Engineer-in-charge) including cost of excavation refilling with meter, C.I bib clock as IS:210 with stainless steel spindle 20 mm o/d MDPE pipe 4.50 mtr (2.50 mtr. MDPE & 2.00 mtr G.I, vertical pipe) 3" i/d uPVC clamps, GM ferrule ISI marked connection of 15 mm i/d ferrule medium, specials such as tees, bends, sockets, elbows, nipples (100 mm & 150 mm) union couplings, G.I Hooks etc and Gun metal peet valve (heavy pattern) with hand wheels on MDPE pipeline laid in the ground or inside building, cutting, treading, making hole in wall and testing in trenches in ground complete in all respect.
(i) Total Houses= 358 no.
(ii) Existing Connections = 35 No.
(ii) No. of Water Connection = 323
Providing and fixing 15 mm i/d water meter of reputed make ISI marked. Such as Kranti/ Dashmesh or equivalent multi-jet, magnetically drive, Hermetically sealed, complete in all respect.
(i) Water Meter = 358
Chlorinator
Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 leter of bleaching powder solution /sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter. ( Milton Roy or Equivalent Make )
(i) O & M for 3 months
(ii) Provision for bleaching powder or sodium chlorite for disinfection of water.
Environmental Detail
Making lawns including ploughing & dragging with 'Sohaga' breaking of clods, removal of earth rubbish dressing & Supplying doob grass roots and planting at 15 cm. apart supplying and spreading of farm yard manure @0.18cum per 100sqm & loosening
Supplying and planting permanent trees including digging of pits size 75cm x 75cm x 75cm deep, refilling the excavated earth. With with manure supplied @ 0.113 4 cum each like Neem ,Ashoka ,Dake Arjun Etc.
Planting ground cover plants including digging and refilling of beds with excavated soil and FYM, Fertilizer and insecticides, planting of saplings at 30cm distance from plant to plant and row to row, providing and fixing brick tiles edging.
Planting flower beds including digging and refilling of beds with excavated soil and FYM, fertilizer and insecticides, planting of sapling at 30cm distance from plant to plant and row to row. Around pump chamber OHSR and both side of path.
Provision for One way stand post with Khurra complete in all respects.
GURSHARAN SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .