Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹47.8 L+₹7.3 L (17.9%)Rejected-AOC NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹48.2 L+₹7.7 L (19.0%)Rejected-AOC | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹48.2 L+₹7.7 L (19.1%)Rejected-AOC | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹48.4 L+₹7.9 L (19.5%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹80,500
Closing Date
19 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
PROVIDING SERVICES FOR MANNING AND OPERATION OF CENTRAL TYPE AC PLANTS AND COMPREHENSIVE MAINTENANCE OF CASSETTE, SPLIT, WINDOW TYPE ACs AT LRDE BANGALORE
2020_MES_381961_1
GE(I) R ND D (WEST)/BAN/41 OF 2020-21 8838E8
Open Tender
Manpower Supply
Item Rate
330 days
Bengaluru
Refer NIT for details
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹80,500
Yes
22 Dec 2020
28 Oct 2020
25 Nov 2020
29 Oct 2020
19 Nov 2020
13 Nov 2020
29 Oct 2020 - 12 Nov 2020
60 days
Amount
SCHEDULE 'A' PART - I (OUTSOURCING SERVICES)
Providing services for operation of following air conditioning plants including AHU's and other related equipments as directed by Engineer-in-Charge for smooth and efficient performance as required to achieve optimum / desired room temperature to relieve inside conditions with minimum required trained manpower in one shift from 0830 Hrs to 1630 Hrs per day excluding Sundays and Holidays (Plant Operator - 4 Nos & Helper - 4 Nos per day) complete all as specified and as directed:- (a) AT LRDE ADMIN AC PLANTof Make :- Blue Star, VRF System of 120 Aggregate in 2 units of equal capacity without stand by. (b) AT LRDE SNFM CONTROL CABIN (Make :- BLUESTAR) 22 TR Air cooled scroll chiller type comprising of 02 Nos scroll Compressor and 02 Nos of air cooled condenser. (c) AT LRDE GM PROGRAMME AC PLANT (Make :- BLUESTAR) 2 x 22 TR Air cooled scroll chiller type, comprising of 02 Nos scroll Compressor and 02 Nos of air cooled condenser. (d) AT LRDE NEW CHAMBER AC PLANT (SNFM lab) (Make :- BLUESTAR) 22 TR Air cooled scroll chiller type comprising of 02 Nos scroll Compressor and 02 Nos of air cooled condenser. (e) AT MED BUILDING AC PLANT LRDE (Make :- ACCEL) Central type direct expansion system of 11 aggregate tonnages in 1 unit without stand by unit. (f) AT SEMINAR HALL AC PLANT (Make :- KIRLOSKAR) Central type direct expansion system of 58 aggregate tonnage in 2 units of equal capacity out of which one is stand by. (g) AT PCB AC PLANT (Make :- ACCEL) Central type direct expansion system of 36 aggregate tonnage in 3 units of equal capacity out of which one is stand by. (h) AT RTP AC PLANT( Make :- ACCEL) Direct expansion system of 38 aggregate tonnage in 2 units of equal capacity with stand by unit.
Notes for Sl Item No 1.00 to 2.02 (including Sub Items) Contd., NOTES :- (i) Absent from duty of technician is not permissible as E&M services essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery from bill shall be done through recovery statement.The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding. (ii) Details of equipment/services to be maintained are indicated as appendices in PS. (iii) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. The provision of statutory laws relating to minimum wages, EPF, EDLI, ESIC, Bonus, GST, Cess & other levies payable shall be strictly adhered to by the contractor. The Contractor shall produce proof of wages, EPF, ESIC, Bonus paid against the respective workmen while claiming payments. (iv) Bidders are advised to follow the websites/ notifications of respective Department/ Organization regularly, and ensure that any changes in minimum fair wages/ contributions, Taxes are accounted by them and revise their quoted rates accordingly before end date of submission of Bid. No claim of not aware of new Notifications / Circulars will be entertained after bids are closed on account of revisions. (v) The rates quoted by the Contractor / firm shall not be less than minimum wages as notified by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable. vi) Tenderer shall work out and quote the rates under Col 5, Col 7, Col 9, Col 11 & Col 13 for each item / sub items. Rate quoted under Col 9 (overheads and Profits) shall also deemed to include for consumable items, uniforms, stationery charges, etc., required for proper operation and maintenance of equipments.
Notes for Sl Item No 1.00 to 2.02 (including Sub Items) Contd., vii) Bid submitted by Tenderer under following stipulations shall be treated as non - bonafide / invalid / disqualified and such bids will not be considered for acceptance and in such case the lowest bidder shall be determined from amongst the valid / bonafide bids only :- a) Quoting wages under Col 5 against any item / sub-items of BOQ shall not be less than the prevailing minimum rates of wages payable as notified by Govt. of India/ Concerned State Govt / Local body whichever is higher. b) Quoted rate under Col 7 i.e., Bonus, shall not be less than Minimum payable (8.33%) and shall be based on actual payment basis. c) Quoted % under col 9 i.e., for “OH&P, consumable items, uniforms, stationary, etc., should not be “Nil”/”Zero” consideration, d) ESIC % under Column 13 is @ 3.25% subject to Salary less than 21,000/- as per instructions in vogue viii) In case Contractor is liable to pay EPF, % quote under Column 11 shall not be less than % applicable as per EPF & MP Act and its latest notifications / amendments. ix) Quoted rates shall deemed to be inclusive of all taxes, cess, levies as applicable including GST. x) Any Govt / statutory variations in minimum wages, liability of EPF, ESIC, EDLI, BONUS, LWC, GST shall be adjusted from re-imbursement / recovery as specified in Special Conditions here-in-after. The prevailing wages / Contribution prevailing on the bid submission end date shall be base for adjustment / re-imbursement as specified here-in-after. xi) Exemptions / limiatations, if any shall not be considered while quoting rates, EPF, ESIC, BONUS, LWC as the same shall be calculated during actual contribution payable depending upon the salary of the individual based on the number of days engaged in the work.
Notes for Sl Item No 1.00 to 2.02 (including Sub Items) Contd., xi) Contractor’s attention is invited to Labour Wages Act with regards to payment of wages to the individuals engaged under this work. Contractor shall make the payments to their staff / employees by Cheque or through NEFT in their Bank Account, and the particulars of same shall be submitted to the department while claiming any payment. No payments will be made, unless proof of payment of wages through bank account is submitted by the Contractor/firm while claiming bills. xii) The wages, / contribution towards EPF, EDLI, ESIC, Bonus shall be paid by the GE in RAR / Final bill only after submission of valid and authentic document in support of proof of payment / contribution of requisite amount to the workmen by the Contractor. In case, the Contractor fails to submit proof of payment made to Workmen, no payment will be made by Department. xiii) Payment in respect of any item / sub-item of BoQ in RAR / Final bill towards the wages, EPF, EDLI, ESIC, Bonus shall be made on the actual amount paid to the Workmen by the Contractor, subject to maxium of the rate quoted under respective heads, plus his quoted OH&P & LWC and no extra claim by the Contractor shall be admissible in this account. In case, Contractor pays less than quoted rates, payments will be made on the actual amount paid by the Contractor plus his quoted OH&P & LWC and no extra claim by the Contractor shall be admissible in this account and onus of responsibility of violation of respective Acts rests with Contractor.
Rate for Plant Operator (Semi Skilled) per Shift (from 0830 Hours to 1630 Hours)
Rate for Helper (Unskilled) per Shift (from 0830 Hours to 1630 Hours)
All as per Serial item No 1.00 here-in-above, but for additional manning hours for operating beyond the period under Sl Item No 1.00 here - in - above, i.e., after 1630 hours, and for operating on Sundays / Holidays if required and specifically orders by Engineer-in-Charge / GE / Lab Director. (Plant Operator - 1 No & Helper - 1 No)
Rate for Plant Operator (Semi Skilled) per Hour
Rate for Helper (Unskilled) per Hour
Description of Work / Item(s)
Amount
SCHEDULE 'A' PART - II (COMPREHENSIVE MAINTENANCE & SUPPLY OF MATERIALS)
Comprehensive maintenance of LRDE SNFM CONTROL CABIN AC PLANT (Make :- BLUESTAR) - 22 TR Air cooled scroll chiller type comprising of 02 Nos scroll compressor and 02 Nos of air cooled condensers including replacement of worn out / defective parts and components, gas filling all as required for smooth and efficient functioning of AC plant to achieve desired cooling conditions and carrying out the complete checks as per manufacture's instructions comprising of motors, condensers, chilling unit, Air handling unit, supply and return through air ducts, control panels, safety devices etc., all as specified and as directed by the Engineer-in-charge.
Comprehensive maintenance of LRDE GM PROGRAMME AC PLANT(Make :- BLUESTAR) 2 x 22 TR Air cooled scroll chiller type, comprising of 02 Nos scroll compressor and 02 Nos of air cooled condensers including replacement of worn out / defective parts and components, gas filling all as required for smooth and efficient functioning of AC plant to achieve desired cooling conditions and carrying out the complete checks as per manufacture's instructions comprising of motors, condensers, chilling unit, Air handling unit, supply and return through air ducts, control panels, safety devices etc., all as specified and as directed by the Engineer-in-charge.
Comprehensive maintenance of LRDE NEW CHAMBER AC PLANT (SNFM lab) (Make :- BLUESTAR) 22 TR Air cooled scroll chiller type comprising of 02 Nos scroll compressor and 02 Nos of air cooled condensers including replacement of worn out / defective parts and components, gas filling all as required for smooth and efficient functioning of AC plant to achieve desired cooling conditions and carrying out the complete checks as per manufacture's instructions comprising of motors, condensers , chilling unit, Air handling unit, supply and return through air ducts, control panels, safety devices etc., all as specified and as directed by the Engineer-in-charge.
Comprehensive maintenance of SEMINAR HALL AC PLANT (Make :- KIRLOSKAR) Central type direct expansion system of 58 aggregate tonnage in 2 units of equal capacity out of which one is stand by including replacement of worn out / defective parts and components, gas filling all as required for smooth and efficient functioning of AC plant to achieve desired cooling conditions and carrying out the complete checks as per manufacture's instructions comprising of motors, condensers , chilling unit, Air handling unit, supply and return through air ducts, control panels, safety devices etc., all as specified and as directed by the Engineer-in-charge.
Comprehensive maintenance of PCB AC PLANT (Make :- ACCEL) Central type direct expansion system of 36 aggregate tonnage in 3 units of equal capacity out of which one is stand by including replacement of worn out / defective parts and components, gas filling all as required for smooth and efficient functioning of AC plant to achieve desired cooling conditions and carrying out the complete checks as per manufacture's instructions comprising of motors, condensers , chilling unit, Air handling unit, supply and return through air ducts, control panels, safety devices etc., all as specified and as directed by the Engineer-in-charge.
Comprehensive maintenance of MS Motorized sliding gate (02 Nos) checking once in month, cleaning and carry out necessary repair/maint as required complete including rewinding or replacement of electric motor as required at site, top guide of gate, guide roller assembly, drive system, compressing motor open box, rack pinion, manual over side mechanism base plate, control system /panel with actuator, safety system control panel complete all as specified and as directed by Engineer-in-Charge.
Carrying out servicing of cassette/ split/ window type AC’s 1.5 Ton / 2 Ton / 3 Ton capacity of any type and make, in position, comprising of cleaning to free from dust, cleaning the evaporator, air filters, condenser coil with cleaning agent and water, tightening all electrical contacts, bolts, nuts etc., greasing / oiling blower motor, testing the serviceability, replacement of worn out rubber bushes, connector, clips, bolts, nuts, washers etc., including replacement of spares and attending to complaints on call in a day as and when required complete all as specified and as directed.. Notes for Sl Item Nos 1.00 to 7.00 :- (i) Absent from duty of technician is not permissible as E&M services essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery from bill shall be done through recovery statement.The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding.
Notes to Sl Item Nos 1.00 to 7.00 (Contd.,) (ii) Details of equipment/services to be maintained are indicated as appendices in PS. (iii) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of all the labour regulations in force lies with the tenderer.The provision of statutory laws relating to minimum wages, EPF, ESI payments shall be strictly adhered to by the contractor. (iv) The rates quoted by the Contractor / firm shall not be less than minimum wages as notified by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable. (v) Spares and major repair jobs shall be measured and paid separately under relevant items of this schedule.
Removing the cassette/ split/ window type AC of 1.5 ton / 2 ton/ 3 ton capacity working on 230 Volts, single phase, / 440 Volts, 3 phase complete including indoor and out door unit and reinstall at any place (with in the same lab area) at height up to 10 mtr above from floor level, replacement of refrigerant tubing up to 7.5 mtrs length and provision of drain pipe and pipe insulation, connecting with existing power socket and testing the unit for smooth functioning including making good of all disturbed surfaces complete all as specified and as directed.
Taking down cassette/ split/ window type AC 1.5 / 2 / 3 ton capacity, flushing the refrigeration system with CO2, supply and charging refrigerant R-22 / R-140 / R-134A, re-fixing in position, testing and commissioning complete all as specified and as directed.
Taking down cassette/ split/ window type AC of 1.5 / 2 and 3 Ton capacity for carrying out repairs, re-fixing in position, testing for efficient cooling temperature and satisfactory working conditions and commissioning after completion of repairs by replacing necessary spares complete all as specified and as directed.. NOTE:- Spares and major repair jobs shall be measured and paid separately under relevant items of this schedule.
Re-winding of fan motor with standard gauge super enameled copper wire including replacement of bushes, complete servicing and overhauling the motor and re-fixing for out door unit of split type AC’s 1.5 / 2 Ton capacity all as directed.
All as per Sl Item No. 11 above but for indoor unit of split type AC’s 1.5 / 2 ton capacity all as directed.
All as per Sl Item No. 11 above but for Window type AC’s 1.5 ton capacity all as directed.
All as per Sl Item No. 11 above but for split/cassette type AC’s 3 TR capacity out door unit all as directed.
All as per Sl Item No. 11 but for split/cassette type AC’s 3 TR capacity indoor unit all as directed.
Supply only condenser coil assembly complete suitable for 1.5 / 2 ton window/ split type AC complete all as specified and as directed..
Supply only evaporator coil assembly complete suitable for 1.5 / 2 ton window / split type AC complete all as specified and as directed..
Supply only condenser coil assembly complete suitable for 3 ton split / cassette type AC complete all as specified and as directed..
Supply only evaporator coil assembly complete suitable for 3 ton split / cassette type AC complete all as specified and as directed..
Supply, installation and testing factory repaired compressor including charging of refrigerant gas, leak testing etc., suitable for cassette / split type AC of 3 ton capacity of existing make including installation and testing complete all as specified and as directed.
All as per Sl Item No. 20 above but for Split / Cassette type AC of 2 ton capacity all as specified and as directed.
All as per Sl Item No. 20 above but for split/ cassette type AC of 1.5 ton capacity all as specified and as directed.
Supply only, Starting capacitor 80-120 Mfd, 230 Volts, AC, 50 Hz suitable for, 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Running capacitor 36 Mfd, 440 Volts, AC, 50 Hz suitable for, 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Running capacitor 45 Mfd , 440 Volts, AC, 50 Hz suitable for, 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Fan motor capacitor 4 / 6 Mfd, 440 Volts, AC, 50 Hz suitable for, 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Air filter suitable for 1.5 / 2 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Air filter suitable for 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Air filter, suitable for 1.5 / 2 TR capacity cassette type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Air filter, suitable for 3 TR capacity cassette type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Single pole contactor up to 25 Amps suitable for, 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, three pole contactor up to 25 Amps and replacing with new items suitable for 3 TR capacity cassette type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Auxiliary contactor single-phase 220 Volts 10 Amps current capacity and replacing with new items suitable for 1.5 / 2 / 3 TR capacity cassette type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Start Relay and replacing with new item start relay suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Thermostat and replacing with new thermostat suitable for 1.5 / 2 / 3 TR capacity split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, PCB card and replacing with new PCB card suitable for 1.5 / 2 / 3 TR capacity cassette/ split type Air conditioners including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Corded remote controller suitable for, 1.5 / 2 / 3 TR capacity split type Air conditioners complete all as specified and as directed..
Supply only, Condenser fan motor for 1.5 TR/ 2 TR capacity suitable for, split / cassette type outdoor unit including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Condenser fan motor for 3 TR capacity suitable for, split /cassette type outdoor unit including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Copper pipe 5 /8" complete with insulation of thickness 10 mm and replacing with new items including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Copper pipe 3 /8" complete with insulation of thickness 10 mm and replacing with new items including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Copper pipe 1/4" complete with insulation of thickness 10 mm and replacing with new items including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, PVC drain pipe 25 mm dia and replacing with new pipe including testing for satisfactory working conditions complete all as specified and as directed..
Supply only, Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and as directed.
Supply only, Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and as directed.
Glacier Cooling Solutions Private Limited
R Tech Mech
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
RAHUL ENTERPRISES
RAHUL ENTERPRISES
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
R Tech Mech
Glacier Cooling Solutions Private Limited
Bidder Name
UNIVERSAL ENGINEERING
Glacier Cooling Solutions Private Limited
RAHUL ENTERPRISES
R Tech Mech
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .