SE TandC Circle Roorkee
220 kV SS Roorkee
Work of Providing and Fixing CT CVT PT Junction Boxes at 220 kV SS Jhajhra Dehradun
2026_PTC21_102273_1
T07 SE TandC R 2026 27
Open Tender
Electrical Works
Item Rate
220 kV Subdivision Jhajhra
Please Refer Tender Notice and Tender Document
3 documents required · 3 mandatory
₹1,180
EE TandC Division Dehradun
₹50,350
Yes
13 Nov 2026
13 Nov 2026
15 Dec 2026
14 Nov 2026
14 Dec 2026
14 Nov 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Work | |||||
| 1.1 | Supply of best-quality outdoor CT / CVT Junction Box (800 × 600 × 300 mm, 2.0 mm CRCA) for 220 kV bays, fitted with 1100 V, 10 A disconnecting, CT-shorting terminal blocks with 20% spare, non-corrosive epoxy or polyester powder-coat finish (80 to 100 microns), water-restraining canopy, toughened glass inspection window, two-end sealing arrangement and facility for at least two padlocks, as per approved drawings and tested to the tender specification. | 7 | Nos | - | - |
| 1.2 | Supply of best-quality outdoor CT / CVT Junction Box (700 × 500 × 250 mm, 2.0 mm CRCA) for 132 kV bays, fitted with 1100 V, 10 A disconnecting, CT-shorting terminal blocks with 20% spare, non-corrosive epoxy or polyester powder-coat finish (80 to 100 microns), water-restraining canopy, toughened glass inspection window, two-end sealing arrangement and facility for at least two padlocks, as per approved drawings and tested to the tender specification | 12 | Nos | - | - |
| 1.3 | Supply of best-quality outdoor CT / CVT Junction Box (500 × 400 × 200 mm, 2.0 mm CRCA) for 33 kV bays, fitted with 1100 V, 10 A disconnecting, CT-shorting terminal blocks with 20% spare, non-corrosive epoxy or polyester powder-coat finish (80 to 100 microns), water-restraining canopy, toughened glass inspection window, two-end sealing arrangement and facility for at least two padlocks, as per approved drawings and tested to the tender specification | 8 | Nos | - | - |
| 1.4 | Erection of 220kV CT / CVT Junction Box by fabrication means as cutting, drilling welding etc with complete cost of all labour, material and T&P required for the proper completion of work. | 7 | Nos | - | - |
| 1.5 | Erection of 132kV CT / CVT Junction Box by fabrication means as cutting, drilling welding etc with complete cost of all labour, material and T&P required for the proper completion of work. | 12 | Nos | - | - |
| 1.6 | Erection of 33kV CT / CVT Junction Box by fabrication means as cutting, drilling welding etc with complete cost of all labour, material and T&P required for the proper completion of work. | 8 | Nos | - | - |
| 1.7 | Dismantling of old CT / CVT / PT Junction Boxes of 220 kV, 132 kV and 33 kV bays after shifting of cable cores to the new boxes, including verification of the de-energised condition, disconnection and insulation of remaining wires, safe removal of glands and boxes without damage to cables and live equipment, work at height with PPE and harness, blanking of holes and touch-up painting of the structure, tagging and handing over of materials to the store with receipt, and a bay-wise dismantling report, all under a permit-to-work with full safety measures, as per the tender specification. | 27 | Job | - | - |
| 1.8 | Work of Wiring in New CT / CVT / PT Junction Boxes of 220kV, 132kV and 33kV Bays by Shifting of existing, already-laid control cable cores from old CT / CVT / PT Junction Boxes to new Junction Boxes, including recording of existing terminations, disconnection and reconnection of all cores with new lugs and ferrules, re-glanding with weatherproof glands and armour earthing, CT shorting and PT/CVT isolation during work, single-point secondary earthing, circuit labelling, insulation, continuity, polarity and ratio testing, two-end sealing with two padlocks, and dismantling of the old boxes, all under a permit-to-work with full safety measures, as per the tender specification. | 27 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TenderDoc07.pdf
Tender Documents • 0.76 MB
BOQ_120439.xls
BOQ • 0.29 MB
TS.pdf
Other Document • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .