GE NS KOCHI
Military Engineer Services, Garrison Engineer (Naval Services), Kataribagh, Naval Base Post, Kochi, 682 004.
FUNCTIONAL REQUIREMENT OF AC PLANTS AT UAV, ALDR, MO(K) AREA INCLUDING ROUTINE MAINTENANCE OF PRECISION AIR COOLED SYSTEM, FAN COIL UNITS, SUSPENSION TYPE AHUS AT NAVAL BASE KOCHI
2021_MES_435394_1
8783/E8
Open Tender
Electrical and Maintenance Works
Works
330 days
KOCHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹90,600
Yes
18 Jun 2021
22 Apr 2021
19 May 2021
22 Apr 2021
17 May 2021
2 May 2021
22 Apr 2021 - 1 May 2021
Amount
Providing services of one AC mechanic for central AC plants from 0600 hours to 2200 hours in Two shifts per day as per users requirement during summer/ monsoon/ winter and maintain the inside temperature and RH as per design and/ or the requirement of users (where air conditioning have been provided) including carrying out of periodical check up and cleaning complete all as specified for the following plants:- Central AC plant installed at ALDR Garuda (Chilled Water Type)(excluding Sunday/holidays) (i) 20X2 =40 TR capacity (In operation) (ii) 20X1 =20 TR capacity (As standby)
Providing services of one AC mechanic for central AC plants from 0600 hours to 2200 hours in Two shifts per day as per users requirement during summer/ monsoon/ winter and maintain the inside temperature and RH as per design and/ or the requirement of users (where air conditioning have been provided) including carrying out of periodical check up and cleaning complete all as specified for the following plants:- At Navigation Direction School (excluding Sunday/holidays) (i) 75X2 =150 TR capacity (In operation) (ii) 75X1=75 TR capacity (As Stand by)
Ditto All as per Item No 2, but for installations installed at UAV Squadron Garuda (excluding Sunday/holidays) (i) 16X2 =32 TR capacity (In operation) (ii) 16 X1=16 TR capacity (As Stand by)
Notes for Item No 1 to 3: (i) Minor complaints shall be done through Ac plant operator of respective central AC Plant Tripping i.e. strainer blockage, dries chock, solenoid failures, valves failure, water level maintain in CTs etc shall be included in above quoted rate. (ii) Operators employed for duties from 0600 hours to 2200 hours inTWO shifts per day ,duties on excluding sunday and holidays and and the Shift operator having ITI/ITC pass in Refrigeration Mechanic trade from any Govt recognised college/institutions and having min 2 years experience in AC plant operations. (iii) Contractor shall be include the cost/expense in unit rate for providing the protecting cloths, tools, computer,& consumables and shift uniform for operator on deployed work. (iv) Certificate of Technical education qualification for the employing person shall be procured before assigning the job. (v) The operator should be filling of daily log sheets and deposit monthly, Log books shall be provided by contractor for entire duration of CA. (vi) Security of entire AC plants area shall be rest with contractor to ensure that no other person should be entered without permission of JE/EIC/GE. (vii) All necessary tools should be available with contractor, Contractor ensure cleaning of installation and Ac plant premises internal and external including roof top of building are deemed to be inclusive details of minimum staffs to be employed. (viii) Unit rate shall be deemed to be including all type of taxes, contribution towards social welfare of workers as per labour act i.e. EPF,ESIC,Insurance etc necessary documents shall be provide before claiming if any payments.
All as per item No 2 above but in 1 shift and operation as per user requirement.(0900 hrs to 1700 hrs) Central AC plant installed at SH No 27/29 MO(K) (DX Type) (i) 40X2 =80 TR capacity (In operation) (excluding Sunday/holidays)
Notes for Item No 4: (i) Minor complaints shall be done through AC plant operator of respective central AC Plant Tripping i.e. strainer blockage, dries chock, solenoid failures, valves failure, water level maintain in CTs etc shall be included in above quoted rate. (ii) Operators employed for duties from 0900 hours to 1700 hours in One shifts per day ,duties on excluding sunday and holidays and the Shift operator having ITI/ITC pass in Refrigeration Mechanic trade from any Govt recognised college/institutions and having min 2 years experience in AC plant operations. (iii) Contractor shall be include the cost/expense in unit rate for providing the protecting cloths, tools, computer & consumables and shift uniform for operator on deployed work. (iv) Certificate of Technical education qualification for the employing person shall be procured before assigning the job. (v) The operator should be filling of daily log sheets and deposit monthly, Log books shall be provided by contractor for entire duration of CA. (vi) Security of entire AC plants area shall be rest with contractor to ensure that no other person should be entered without permission of JE/EIC/GE. (vii) All necessary tools should be available with contractor, Contractor ensure cleaning of installation and Ac plant premises internal and external including roof top of building are deemed to be inclusive details of minimum staffs to be employed. (vii) Unit rate shall be deemed to be including all type of taxes, contribution towards social welfare of workers as per labour act i.e. EPF,ESIC,Insurance etc necessary documents shall be provide before claiming if any payments.
M & L for Monthly servicing including taking out complete air filters from sealing suspended type AHU carefully and cleaning, including arrangement of scaffolding/ladder for removing dust by using pressure water, greasing shaft and bearings, alignment of blower motor, tightening of blower V belt and refixing filters after drying all as specified and directed by Engineer-in-charge. Note:-Replacement of Air Filter shall be responsibility of contractor if damage occurs while removing or refixing.
M & L for Monthly Servicing to the indoor unit Fan Coil Unit clean with mild Air blower in the coil side including arrangement of scaffolding/ladder for remove the inside fine filter, cleaned with Soap solution after cleaning process fix in proper place , check the drainage water/chilled water pipelines, rectify if any leakage found and provide service to the printed circuit board also, all as specified and directed Make: Zeco
M & L for Monthly servicing to the outdoor unit and indoor unit of Precision air conditioning system, cleaning of filters & condenser by using pressure water, clean with mild Air blower in the cooling coil side and servicing the entire unit including repairing, maintenance and replacement of unserviceable parts, check gas leakage and rectified if any all as specified and directed by Engineer in charge. Make :Bluestar/Uniflair
M & L for dismantling of defective condenser/chiller pump motor capacity up to and including 5 HP after disconnecting electric connection from foundation, removing defective bearing, gland bush,heating,insulating and baking of existing motor winding, replacement of bearing, gland bush,gaskets,gland packing, nut and bolt, assembling, refitting and decommissioning including refixing of all electrical connections, testing of RPM by using digital Tachometer after repair all as specified and directed by Engineer-in-charge.
Ditto all as per item no 8 but for capacity above 5 HP and upto 7.5 HP
M & L for dismantling of defective CT fan motor of capacity upto 3 HP including disconnecting electric connection, fan blade and burnt motor opening, burnt coil removing , cleaning , rewinding with Super Enameled copper wire of existing size , insulating , varnishing , heating , baking , re assembling , replacement of motor bearing of existing size including transportation from existing location to workshop and back, refixing of electrical connections , testing of RPM by using digital Tachometer after repair , refixing of fan bush ,and balancing of fan, re-commissioning all as specified and directed by Engineer-in-charge.
Ditto all as per item no 10 but for capacity above 5 HP and upto 7.5 HP
Ditto all as per item no 10 but for capacity above 7.5 HP and upto 15HP
M & L for dismantling of defective AHU motor of capacity upto 3 HP including fan after disconnecting electric connection from foundation and burnt motor opening, burnt coil removing , cleaning , rewinding with Super Enameled copper wire of existing size , insulating , varnishing , heating , baking , re assembling , replacement of motor bearing of existing size including transportation from existing location to workshop and back, refixing of electrical connections , testing after repair , refixing of blower belt ,alignment with blower with motor, re-commissioning all as specified and directed by Engineer-in-charge.
Ditto all as per item no 13 but for capacity above 3 HP and upto 7.5 HP
Ditto all as per item no 13 but for capacity above 7.5 HP and upto 15HP
Supply and replacement in repair round type cooling tower sprinkler aluminium with distributer pipe & stay rod suitable for capacity upto 60 TR all as specified and directed. Make of cooling Tower: Paharpur/Mihir/Delta.
Supply and replacement in repair round type cooling tower sprinkler aluminium with distributer pipe & stay rod suitable for capacity 80 TR all as specified and directed. Make of cooling Tower: Paharpur/Mihir/Delta.
Supply and replacement in repair round type cooling tower sprinkler aluminium with distributer pipe & stay rod suitable for capacity 100 TR all as specified and directed. Make of cooling Tower: Paharpur/Mihir/Delta.
Supply and replacement in repair round type cooling tower sprinkler aluminium with distributer pipe & stay rod suitable for capacity 120 to 150 TR all as specified and directed. Make of cooling Tower: Paharpur/Mihir/Delta.
Supply and replacement in repair round type cooling tower sprinkler aluminium with distributer pipe & stay rod suitable for capacity 240 TR all as specified and directed. Make of cooling Tower: Paharpur/Mihir/Delta.
S&F in replacement of PVC Fills of size 150x300x600 mm, with fine quality all as specified and directed.
S&F in repair PVC nozzles 3/4'' dia for rectangular type cooling tower all as specified and directed.
S & F in replacement of PVC heavy grade pipe of size 40 mm to 80mm with having drilling holes for water spray distribution line in cooling tower including complete connection with hub, sprinklers of existing CT fan Shaft all a specified and directed
S & F in replacement of PVC heavy grade round pipe of size 100 mm with having drilling holes for water spray distribution line in cooling tower including complete connection with hub, sprinklers of existing CT fan Shaft all a specified and directed
Supply and Fixing in repair CI 'Y' strainer of size 50 mm dia in condensing/chilled water line complete dia including modification of pipe line for fixing the strainer and replacement of flanges and nuts & bolts, packing etc all as specified and directed by Engineer incharge.Make:Advance/Leader/Castlers/Sant
Ditto as per item no 25 but for CI 'Y' strainer of size 65 mm dia
Ditto as per item no 25 but for CI 'Y' strainer of size 80 mm dia
Ditto as per item no 25 but for CI 'Y' strainer of size 100 mm dia
Ditto as per item no 25 but for CI 'Y' strainer of size 125 mm dia
Taking down the unserviceable butterfly valve, Supply and fix CI butterfly valve full open with operating handle of size 50 mm dia including replacement of old nuts & bolts, packing modification of flanges if necessary and all as per specified and directed.
Ditto as per item no 30 but for Butterfly valve of size 65 mm dia
Ditto as per item no 30 but for Butterfly valve of size 80 mm dia
Ditto as per item no 30 but for Butterfly valve of size 100 mm dia
Taking down corroded GI pipe line and replace with GI tubing 65 mm dia medium grade including welding, connecting and painting two coat of synthetic enamel paint all as specified and directed.
Ditto as per item no 34 but for of size 80 mm dia
Ditto as per item no 34 but for of size 100 mm dia
Taking down the unserviceable dual plate check valve, Supply and fix dual plate check valve of size 50 mm dia including replacement of old nuts & bolts, packing modification of flanges if necessary and all as per specified and directed
Ditto as per item no 37 but for Butterfly valve of size 65 mm dia
Ditto as per item no 37 but for Butterfly valve of size 80 mm dia
Ditto as per item no 37 but for Butterfly valve of size 100 mm dia
Ditto as per item no 37 but for Butterfly valve of size 125 mm dia
M & L for removal of damaged FRP filling material from the joints of cooling tower CAPACITY 30TR to 300TR and filled with FRP filling material(combination of exosine powder, resin, acetone, catalyst, pigment material) including leak testing complete all as specified and as directed
M&L for removing defective Micro Processor control, model no VLRP 4/5/6 Panel board of existing chiller unit of AC plant capacity 15 TR to 120 TR ,replacing the relay assembly, calibration of Micro processor, return to site, refixing in position, setting all readings and run testing all as specified and as directed by Engineer in charge. Make of unit: Voltas,Bluestar and Carrier
Supply and fix in replacement HEPA Filter at (OT-1,2&3) from inside OT complex at INHS Sanjivani hosp with HEPA chamber box type 0.3 microns, H 13 grade, MOC Aluminium anodised casing. Media: Water repellent Glass micro fiber media with Aluminium corrugated foil separators. Construction: Pleated type. Initial Pressure drops: 25 mm WG , Air Flow : 1000 CFM . Efficiency 99.% down to 0.3 microns, Gasket : Provided on air outlet side, size: 600X600X 75mm (box type) Make: Imbec/Aerosol
Supply and fix in replacement of pre filter from inside OT fixed in the laminar return area, supply and fixing of Pre Filters , Flange type, EU4 Grade, 10 micron, MOC:Aluminum casing, Media : Non-woven synthetic with HDPE mesh on air outlet side Aluminium mesh Pleated support. IPD: 4.5mm, Efficiency:90% down to 10 micron, air flow: 1000cfm, Gasket ; provided. Size : 660x 360x50mm ( Flange) Make: Imbec/Aerosol
M & L for Checking of existing condition of air ducts making the arrangement of visualization and the process for disinfection for Indoor air quality of AC ducts of OT including plenum box, supply air, return air ducts with robotic camera, HEPA Negative machine, air compressor, various types of air nozzles at OT’s of capacity 70 TR and length shall be 25 M of duct size 1.5 metre x .5 metre depth complete all as specified and as directed.
M & L Cleaning of Operation Theater of - 3 nos with 100 % Fresh Air type AHU cooling coil by using Bio Enzyme coil cleaner, pressure jet pump so as to improve heat transfer and avoid fungus formations appx room sizes 8 mtr x 8 mtrx 4 mtr as specified and directed by Engineer-in -charge.
M & L Sanitization of ducts by using fogging machine, Bio-cides so as to avoid fungal/Bacterial formation inside the ducts of having size approx length 25 Mtr x 1.2 Mtr (b) x 0.5 Mtr (d) including 02 Nos of AHU room with blower motor, cooling coil by using with permissible chemicals complete all a s specified and directed.
Supply and fixing plastic mesh heavy duty, mesh size 10 mm X 10mm for cooling tower with necessary fixing arrangements all as specified and as directed by EIC
Supply Fabricate and fixing AC Plant layout diagram, showing compressor/motor, condenser, liquid line, discharge/suction line, including all safety valves, cooling tower, from LT Panel to AHU in 3mm thick white Acrylic sheet of size 90cmx 60cm duly fixed on a superior quality plywood board and fixed on wall all as specified and as directed.
Supply Fabricate and fixing Name index board of AC plant having size of 1.2 metre X0.6 metre X 5mm thick including writing letters on board as directed by Engineer-In-Charge with 0.25 mm thick white rubber coated vinyl sheet or synthetic vinyl sheet printed with computer/scotch inject printing with without ink and laminated with average 15 mm thick high quality weather protected calendar film (coated/laminated and transparent/mat finish) pasted with chemical on and including polycarbonate PVC weather protected milky white/transparent sheet and finally thorough washed with liquid detergent soap complete board to be fixed on wall including cost of all materials used and all as specified and directed. Note: Letter sizes shall be taken approval of EIC before the manufacturing the name boards.
Supply and fixing of cooling tower fan blade upto capacity 30 TR suitable in existing CT fan hub with suitable length (appx 300mm to 450 mm) and size with aluminum alloy material with necessary nuts, bolts and washers complete all as specified and directed.
Supply and fixing of cooling tower fan blade capacity 35TR to 100 TR suitable in existing CT fan hub with suitable length (appx 300mm to 450 mm) and size with aluminum alloy material with necessary nuts, bolts and washers complete all as specified and directed.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
N.O. Antony Contractors
AR Traders
General Engineering and Constructions
SREENARAYANA ENTERPRISES
S. M. Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .