| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹8.4 L+₹32,641 (4.06%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹8.4 L+₹36,721 (4.57%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
12 Oct 2022, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur - 342 011 (Raj)
REPAIR AND MAINT OF DISTRIBUTION TRANSFORMERS OF DIFFERENT CAPACITY AND APFC PANEL IN ZONE-A AND ZONE-C AT DEFENCE LAB JODHPUR
2022_MES_552851_1
8503/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹17,000
Yes
23 Jan 2023
19 Sept 2022
14 Oct 2022
19 Sept 2022
12 Oct 2022
28 Sept 2022
20 Sept 2022 - 27 Sept 2022
Amount
Taking out Transformer from its Position for repair / servicing / rewinding of capacity 315 KVA , 11/0.433 Volts, by disconnecting /opening HV, LV Electrical connections, earthing connections along with following other works.
(a) Transporting transformer to workshop and back to site by making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm) as directed. (b) Opening of transformer top cover by extraction ,removing of serviceable - unserviceable nuts bolts and washers. (c) Draining out of transformer oil and keeping in safe custody for reuse. (d) Lifting primary coil (HT) and secondary coil (LT), dismantaling of transformer complete part by part carefully, and display all the parts without damaging any portion and ascertain the serviceability of parts and quantam of repairs involved. (e) Refilling topping up of transformer oil after dehyderation and filteration in transformer. (f) Reassembling the transformer complete with all existing serviceable parts, and new parts as requied. (g) Reinstall the Transformer at site in position as directed after repair connecting HV, LV electrical connections, earthing connections and testing to entire satisfaction on load. Note:- (a) Rewinding , reinsulation of Primary and secondary coil with copper winding wire, dehydration and filteration of transformer oil, and replacement of unserviceable spares shall be measured and paid seperately under appropriate Item of schedule. (b) Renewal of adequate size Nut, bolts & washers of transformer top cover shall deemed to be included in UNIT RATE QUOATED.
M&L for rewinding HT coil of 11/ 0.433 KV Transformer any capacity using proper size DPC copper wire and insulation material , heating coils in heat chamber after rewinding including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed by Engineer-in-charge.
M&L for rewinding LT coil of 11/ 0.433 KV Transformer any capacity using proper size DPC copper wire and insulation material , heating coils in heat chamber after rewinding including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed by Engineer-in-charge.
Disconnecting HT/LT Connection before Repair /servicing and testing of distribution transformer at site of capacity 63 KVA to 400 KVA installed on Plinth / Pole mounted structure by opening top cover & replacing unserviceable spares / components of transformer ,without lifting core assembely reassembling after repair & testing complete all as specified and directed by Engr-in-Charge. Note:- (a) Rewinding of transformer HT/LT Coils shall be carried out from ISO certified 2008 Coy. (b) Dehydration and filteration of transformer oil, and replacement of unserviceable spares shall be measured and paid seperately under appropriate Item of schedule however cost of renewal of Nut, bolts & washers shall deemed to be included in UNIT RATE QUOTED.
Supply and Fixing Ceramic Bush insulators on LT side as per existing size, shape and specification for capacity 63 KVA, 11/0.433 Volts transformers
Supply and Fixing Ceramic Bush insulators on LT side as per existing size, shape and specification for capacity 100 to 160 KVA, 11/0.433 Volts transformers
Supply and Fixing Ceramic Bush insulators on LT side as per existing size, shape and specification for capacity 250 to 400 KVA, 11/0.433 Volts transformers
Supply and Fixing brass spindle on LT side as per existing size, shape and specification for capacity 63 KVA, 11/0.433 Volts transformers
Supply and Fixing brass spindle on LT side as per existing size, shape and specification for capacity 100 to 160 KVA, 11/0.433 Volts transformers
Supply and Fixing brass spindle on LT side as per existing size, shape and specification for capacity 250 to 400 KVA , 11/0.433 Volts transformers
Supply and Fixing cork sheet gasket (set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capacity 63 KVA, 11/0.433 Volts transformers
Supply and Fixing cork sheet gasket (set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capacity 100 to 160 KVA, 11/0.433 Volts transformers
Supply and fixing cork sheet gasket (set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capacity 250 to 400 KVA, 11/0.433 Volts transformers
Supply and Fixing Ceramic Bush insulators on HT side as per existing size, shape and specification for capacity 63 KVA, 11/0.433 Volts transformers
Supply and fixing Ceramic Bush insulators on HT side as per existing size, shape and specification for capacity 100 to 160 KVA, 11/0.433 Volts transformers
Supply and Fixing Ceramic Bush insulators on HT side as per existing size, shape and specification for capacity 250 to 400 KVA, 11/0.433 Volts transformers
Supply and Fixing brass spindle on HT side as per existing size, shape and specification for capacity 63 KVA, 11/0.433 Volts transformers
Supply and Fixing brass spindle on HT side as per existing size, shape and specification for capacity 100 to 160 KVA, 11/0.433 Volts transformers
Supply and Fixing brass spindle on HT side as per existing size, shape and specification for capacity 250 to 400 KVA , 11/0.433 Volts transformers
Supply and Fixing top cover gasket set as per existing size, shape and specification complete for capacity 63 KVA , 11/0.433 Volts transformers
Supply and Fixing top cover gasket set as per existing size, shape and specification complete for capacity 100 to 160 KVA, 11/0.433 Volts transformers
Supply and Fixing top cover gasket set as per existing size, shape and specification complete for capacity 250 to 400 KVA, 11/0.433 Volts transformers
Supply and Fixing set of gasket (rubberized cork ) as per existing size, shape and specification complete for capacity 63 KVA , 11/0.433 Volts transformers
Supply and Fixing set of gasket (rubberized cork ) as per existing size, shape and specification complete for capacity 100 to 160 KVA , 11/0.433 Volts transformers
Supply and Fixing breather assembly as per existing size, shape and specification complete for capacity 63 KVA , 11/0.433 Volts transformers
Supply and Fixing breather assembly as per existing size, shape and specification complete for capacity 100 to 160 KVA, 11/0.433 Volts transformers
Supply and Fixing breather assembly as per existing size, shape and specification complete for capacity 250 to 400 KVA, 11/0.433 Volts transformers
Supply and Fixing Tap Changer as per existing size, shape and specification complete for capacity 63 KVA , 11/0.433 Volts transformers
Supply and Fixing Tap Changer as per existing size, shape and specification complete for capacity 100 to 160 KVA, 11/0.433 Volts transformers
Supply and Fixing Tap Changer as per existing size, shape and specification complete for capacity 250 to 400 KVA, 11/0.433 Volts transformers
Supply & filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacement up to desired level of transformer oil capacity complete all as specified and directed by Engineer-in-charge. [Note: Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.] (Make : GULF/POWER OIL or equivalent as approved by AGE)
Supply and fixing as in replacement Temperature Guage as per existing size, shape and specification complete for capacity 63 KVA , 11/0.433 Volts transformers including taking down old unserviceable complete all as specified and directed by Engineer-in-charge.
Supply and fixing as in replacement Temperature Guage Changer as per existing size, shape and specification complete for capacity 100 to 160 KVA, 11/0.433 Volts transformers including taking down old unserviceable complete all as specified and directed by Engineer-in-charge.
Supply and fixing as in replacement Temperature Guage as per existing size, shape and specification complete for capacity 250 to 400 KVA, 11/0.433 Volts transformers complete including taking down old unserviceable complete all as specified and directed by Engineer-in-charge.
Supply and fixing as in replacement pair of arcing horns suitable for transformer capacity 63 to 400 KVA, 11/0.433 Volts including taking down old unserviceable complete all as specified and directed by Engineer-in-charge.
Supply and replacing silica gel in crystal form of breather assembly of transformer capacity upto 63 to 400 KVA at installed site complete including taking down old unserviceable complete all as specified and directed by Engineer-in-charge.
Material & Labour for 32 mm dia gunmetal drain valve of transformer as per existing one including taking down old unserviceable complete all as specified and directed by Engineer-in-charge.
Material & Labour for 25 mm dia gunmetal drain valve of transformer as per existing one including taking down old unserviceable complete all as specified and directed by Engineer-in-charge.
Material & Labour for 20 mm dia gunmetal drain valve of transformer as per existing one including taking down old unserviceable complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted steel or iron surfaces of transformer of 63 to 160 KVA , 11/0.433 Volts capacity transformers by scrapping with steel wire brush/scrapper emery paper, etc. and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of SM No, MES No etc. at prominent place/location of transformer with black synthetic enamel thick paint in white back ground complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted steel or iron surfaces of transformer of 250 to 400 KVA , 11/0.433 Volts capacity transformers by scrapping with steel wire brush/scrapper emery paper, etc. and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of SM No, MES No etc. at prominent place/location of transformer with black synthetic enamel thick paint in white back ground complete all as specified and directed by Engineer-in-charge.
M&L Earthing complete with Copper earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc including taking out old un-serviceable earthing, complete all as directed by Engineer-in-charge. Note: (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No. 3 of MES SSR Part-I., (ii) Item includes the cost of GI pipe up to 7.5m for protection of earth strip and 32X6 mm GI strip up to 7.50 m length (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Dismantling unserviceable Lightning Arresters with all fittings of any description, complete all as specified and as directed by Engineer-in-charge.
M &L Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA , 11000V grade complete all as specified and directed by Engineer-in-charge.
Dismantling Pin/Disc type insulators with all fittings of any description,Discharge capacity and size, complete all as specified and directed by Engineer-in-charge.
M&L pin type,porcelain,vitreous,white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm Height, 150mm dia for 11000 Volt Grade, complete all as specified and directed by Engineer-in-charge.
M &L Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type white, brown or green, ‘two-in-series assembly’ for tension with tension clamps for conductors, working pressure 11000 Volt, complete all as specified and directed by Engineer-in-charge.
Dismantling Air Break Gang operated switches,Vertical/Horizontal Mounted including insulators and operating mechanism for repair/replacement of broken/worn out component and insulators or carrying to MES store or credited to contractor, complete all as specified and directed by Engineer-in-charge.
M & L Switch Air Break, Gang operated, Triple Pole, Mechanically Operated, mounted on Insulators and Steel Frame with Operating Mechanism worked from ground level,current rating upto 200 to 400 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement of unserviceable PT of 11 KVA/110 Volt all as per existing make complete all as specified and directed by Engineer-in charge.
Shifting and Mounting of Transformer 250 KVA & 315 KVA on RCC Platform from gound surface and joined all HT/LT connections to required site complete all as specified and directed by Engr-in-charge.
Repairs GOD and Drop out fuse unit set 9/12 insulator type complete including replacement of all UNSV jumpers, aluminium lugs, nut bolts ,changing of U clips/Feeze clamp of horizontal/vertical clamps, applying greasing to exixting GOD and DO for smooth functioning including necessary adjustment complete all as specified and directed by Engineer-in-charge.
Supply and Fix in repair Digital Volt Meter for 11/0.433 KV alongwith control wiring suitable for complete all as specified and directed by Engineer-in-charge.
Supply and Fix in repair Digital Amp Meter for 11/0.433 KV alongwith wiring suitable for complete all as specified and directed by Engineer-in-charge.
S&F in repair LED indicator (R,Y,B) for 11/0.433 KV,110 Volt, with control wiring complete all as specified and dirceted by Engr-in-charge.
Supply & Fixing Four pole contactor 25 to 30 Amp including taking down old unserviceable contactor complete all as specified and dirceted by Engr-in-charge.
Supply & Fixing Four pole contactor 35 to 40 Amp including taking down old unserviceable contactor complete all as specified and dirceted by Engr-in-charge.
Supply & Fix MCB, Triple Pole, 32 Amp including taking down old unserviceable complete all as specified and dirceted by Engr-in-charge.
Supply & Fix MCB, Triple Pole, 40 Amp including taking down old unserviceable complete all as specified and dirceted by Engr-in-charge.
M&L for Cable jointing Kit for 11 Kv (Earthered) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm complete all as specified and directed by Engr-in-charge.
M&L for Cable jointing Kit for 11 Kv (Earthered) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engr-in-charge.
M&L for Replacement of any defective capacitor of Rating 1 KVAR to meet the requirement for power factor complete all as specified and directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 3 KVAR to meet the requirement for power factor complete all as specified and directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 4 KVAR to meet the requirement for power factor complete all as specified and directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 7 KVAR to meet the requirement for power factor complete all as specified and directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 10 KVAR to meet the requirement for power factor complete all as specified and directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 12 KVAR to meet the requirement for power factor complete all as specified and directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 15 KVAR to meet the requirement for power factor complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of unserviceable CT for LT with ratio (1000/5) all as per existing make by commissioning and installing complete all as specified and directed by Engineer-in charge.
Supply and fix in replacement of unserviceable CT for LT with ratio (1250/5) all as per existing make by commissioning and installing complete all as specified and directed by Engineer-in charge.
Servicing, Testing & Commissionig of all existing APFC Panel including all others connected accessories and complete wiring required at site complete all as specified and directed by Engineer-in charge. Note: Spares parts replaced with new paid saperately.
Supply and fix in replacement of unserviceable Power factor Control relay for 12 stage all as per existing make by commissioning and installing complete all as specified and directed by Engineer-in charge. Make:- Siemens, L&T, schneider, Epcos, Havells, IndoAsian, Legrand,ABB
SHUBHAM INTERNATIONAL
M/S SUMAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .