| Sl No | Description | Qty | Unit | M/S TZ Engineering Works L2 | M/S ZARDEEP ENTERPRISES L1 | marib constructions L3 |
|---|---|---|---|---|---|---|
| 1.00Creation of Sub-Stations Supply,Installation,Testing & Commissioning of | ||||||
| 1.01 | 11/0.433kV, 3-phase 63 kva Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200kVA, Copperwound for 250kVA or higher kVA )with LV Cable Box having detachable Aluminium Gland plate.Transformer should have arrangement for vertical take off. | 10 | Nos | 1,95,000 ₹19,50,000 Lowest | 2,30,000 ₹23,00,000 | 6,05,515 ₹60,55,150 |
| 1.02 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 10 | Set | 10,500 ₹1,05,000 | 3,500 ₹35,000 Lowest | 3,515 ₹35,150 |
| 1.03 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type | 10 | Set | 17,000 ₹1,70,000 | 12,000 ₹1,20,000 | 9,015 ₹90,150 Lowest |
| 1.04 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 10 | Set | 9,500 ₹95,000 | 3,000 ₹30,000 Lowest | 4,515 ₹45,150 |
| 1.05 | 95 Sqmm (or 70Sqmm (2Ckt)/150Sqmm (or 95Sqmm (2Ckt)/300Sqmm (or 185Sqmm (2Ckt) Cable,1.1KV Grade,XLPE Insulated stranded conductor FRLS type. | 440 | Mtr | 1,200 ₹5,28,000 | 240 ₹1,05,600 Lowest | 275 ₹1,21,000 |
| 1.06 | 9 Mtr. Long Pole,ST-410 SP33 | 193 | Nos | 28,500 ₹55,00,500 | 21,000 ₹40,53,000 Lowest | 25,115 ₹48,47,195 |
| 1.07 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm | 60 | Nos | 1,200 ₹72,000 | 800 ₹48,000 Lowest | 815 ₹48,900 |
| 1.08 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm | 579 | Nos | 900 ₹5,21,100 | 700 ₹4,05,300 | 555 ₹3,21,345 Lowest |
| 1.09 | GI V cross-arm with top Bracket including clamp suitable for 33KV Pin & Disc insulators(sample available with department) | 8,162.75 | Kgs | 150 ₹12,24,412.5 | 165 ₹13,46,853.75 | 135 ₹11,01,971.25 Lowest |
Tender Value
₹1.9 Cr
EMD Value
₹3.4 L
Closing Date
2 Sept 2024, 3:00 pmClosed
Executive Engineer, Electric Distribution Division
Baroo Kargil
SITC for Creation of Different capacity Distribution Transformers along with HT Network at various identified sites under JJM scheme
2024_PDNRE_13728_1
E-NIT NO 44 of 2024-25
Open Tender
Electrical Works
Turn-key
60 days
Kargil
Please refer Tender documents.
9 documents required · 9 mandatory
₹544
Account No 0096010200000064 IFSC Code JAKA0KARGIL
₹3.4 L
3 Sept 2024
14 Aug 2024
3 Sept 2024
14 Aug 2024
2 Sept 2024
27 Aug 2024
Amount
Creation of Sub-Stations Supply,Installation,Testing & Commissioning of
11/0.433kV, 3-phase 63 kva Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200kVA, Copperwound for 250kVA or higher kVA )with LV Cable Box having detachable Aluminium Gland plate.Transformer should have arrangement for vertical take off.
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
95 Sqmm (or 70Sqmm (2Ckt)/150Sqmm (or 95Sqmm (2Ckt)/300Sqmm (or 185Sqmm (2Ckt) Cable,1.1KV Grade,XLPE Insulated stranded conductor FRLS type.
9 Mtr. Long Pole,ST-410 SP33
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
GI V cross-arm with top Bracket including clamp suitable for 33KV Pin & Disc insulators(sample available with department)
Galvinized Nuts and Bolts.
Chemical Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,GO Set & Lightening arrestors as per IS 2629/85,GI nuts & bolts,refilled with earth enhancement materials & earth chamber made of bricks masonary with RCC Slab Cover.
LT Distribution 8ox for 63 and 200 kVA DTR with MCCB for incomer & SFU,s for Outgoing Circuits
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers,binding Tape,
SITC of 30 mm² ACSR Conductor
35 sq mm HT AB Cable (3x35+1x35mm sq ) XLPE 11 KV , 3C+EARTH)
SITC OF 3 PH 4 W PRODIGY METER
Heat Shrinkable Outdoor cable kit
M/S TZ Engineering Works (BID ID -133228)
marib constructions (BID ID -133269)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.27 MB
TenderDrawings.pdf
Tender Documents • 12.03 MB
SBDJJM.pdf
Tender Documents • 0.32 MB
detailsJJM.pdf
Other Document • 0.09 MB
TechSpecTransformers.pdf
Other Document • 0.85 MB
TechSpecPoles.pdf
Other Document • 0.59 MB
BOQ_34273.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .