Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
3 Jul 2023, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LAB JODHPUR
REPAIR/MAINT OF POWER TRANSFORMER, DISTRIBUTION TRANSFORMER OF DIFFERENT CAPACITY AND OTHER CONNECTED WORKS AT DEFENCE LAB JODHPUR
2023_MES_601171_1
8550/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹18,000
Yes
22 Mar 2024
5 Jun 2023
5 Jul 2023
5 Jun 2023
3 Jul 2023
14 Jun 2023
6 Jun 2023 - 13 Jun 2023
Amount
Disconnecting HT/LT Connection before Repair /servicing and testing of distribution transformer at site of capacity 63 KVA to 3.15MVA installed on Plinth / Pole mounted structure by opening top cover & replacing unserviceable spares / components of transformer ,without lifting core assembely reassembling after repair & testing complete all as specified and directed by Engr-in-Charge. Note:- (a) Rewinding of transformer HT/LT Coils shall be carried out from ISO certified 2008 Coy. (b) Dehydration and filteration of transformer oil, and replacement of unserviceable spares shall be measured and paid seperately under appropriate Item of schedule however cost of renewal of Nut, bolts & washers shall deemed to be included in UNIT RATE QUOTED.
Supply and Fixing Ceramic Bush insulators on LT side as per existing size, shape and specification for capacity 63 to 400 KVA, 11/0.433 Volts transformers
Supply and Fixing brass spindle on LT side as per existing size, shape and specification for capacity 63 to 400 KVA, 11/0.433 Volts transformers
Supply and Fixing Ceramic Bush insulators on HT side as per existing size, shape and specification for capacity 63 KVA to 400 KVA, 11/0.433 Volts transformers
Supply and Fixing brass spindle on HT side as per existing size, shape and specification for capacity 63 to 400 KVA, 11/0.433 Volts transformers
Supply only breather for transformer of suitable size up to 63 to 400 KVA transformer complete all as specified and directed by Engineer-in-charge.
Supply only breather for transformer of suitable size for 1000 KVA transformer complete all as specified and directed by Engineer-in-charge.
Supply only breather for transformer of suitable size for 3.15 MVA transformer including taking out unserviceable breather complete all as specified and directed by Engineer-in-charge.
Supply only silica gel for breather of transformer of any type/capacity complete all as specified and directed Engineer-in -Charge.
Ditto but using copper earth Plate 60cm x 60cm x 3.15mm thick electrode and 20x3mm copper strip as earthing lead complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of unserviceable PT complete Box Type- 005, 3 Phase, sta/star connection of 11 KV/110 volt all as per existing make complete all as specified and directed by Engineer-in charge.
Dehydration/filtration of transformer oil by means of centrifugal filtration Machine to achieve the specified dielectric strength of 45 to 60 KV at 2.5 mm gap in existing position of transformer of any capacity and transformer oil for topping up at various substation all as directed by Engr-in-Charge (NOTE: (i)Transformer oil used for TOP UP shall be measured and paid separately as supply only. (ii) Contractor has to make his own arrangement for oil filtration machine/ plant. (iii) Filtration shall be done at site when electricity supplies functional.
Supply & filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacement up to desired level of transformer oil capacity complete all as specified and as directed. [Note: Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.] (Make : GULF/POWER OIL or equivalent as approved by AGE)
Dismantling unserviceable Lightning Arresters with all fittings of any description, complete all as specified and as directed by Engineer-in-charge.
M&L Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA , 11000V grade all as specified and directed by engineer in charge.
M&L Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA , 33000V grade all as specified and directed by Engineer-in- charge.
Dismantling Pin/Disc type insulators with all fittings of any description,Discharge capacity and size, complete all as specified and as directed by Engineer-in-charge.
M&L pin type,porcelain,vitreous,white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm Height, 150mm dia for 11000 Volt Grade, complete all as specified and as directed by Engineer-in-charge.
M&L pin type,porcelain,vitreous,white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm Height, 150mm dia for 33000 Volt Grade, complete all as specified and as directed by Engineer-in-charge.
M &L Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type white, brown or green, ‘two-in-series assembly’ for tension with tension clamps for conductors, working pressure 33000 Volt, complete all as specified and as directed by Engineer-in-charge.
Dismantling Air Break Gang operated switches,Vertical/Horizontal Mounted including insulators and operating mechanism for repair/replacement of broken/worn out component and insulators or carrying to MES store or credited to contractor, complete all as specified and as directed by Engineer-in-charge.
M&L Switch Air Break, Gang operated, Triple Pole, Mechanically Operated, mounted on Insulators and Steel Frame with Operating Mechanism worked from ground level,current rating upto 200 to 400 Amps complete all as specified and as directed by Engineer-in-charge.
Repairs GOD and Drop out fuse unit set 9/12 insulator type complete including replacement of all UNSV jumpers, aluminium lugs, nut bolts ,changing of U clips/Feeze clamp of horizontal/vertical clamps, applying greasing to exixting GOD and DO for smooth functioning including necessary adjustment complete all as specified and directed by Engineer-in-charge.
Disconnecting and taking out existing HT 33 KV VCBs (Make : ALSTOM) from housing and cleaning, rubbing and servicing the mechanical parts incl , replacement of UNSV Trip coil, Breaker charging motor ,Gear Panion, roller Switch, Big gear etc and re-assembling the same after replacement as required and ,make the VCB serviceable including making all electrical Connection and Testing ( IR Test, Continuity Test, Tripping test of earth fault and Over current of panel ) complete all as specified and directed by Engineer-in-charge. Note:- The Spare parts of VCB panel are measured and paid saperately as supply only.
Supply & fixing Trip coil 300 Volt suitable for 33 KV VCB panel complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Closed coil 300 Volt suitable for 33 KV VCB panel complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Electrochemical type relay set of two O/C and one EF for 33 KV, Auxiliary supply 30 Volt DC for VCB panel complete all as specified and directed Engineer-in -Charge.
S&F spring charge motor 230Volts AC for 33KV (ALSTOM VCB) including taking down old unserviceable spring charge motor complete all as specified & directed by Engineer-in-charge.
Disconnecting and taking out existing HT 11 KV VCBs from housing and cleaning, rubbing and servicing the mechanical parts incl , replacement of UNSV Trip coil, and re-assembling the same after replacement as required and ,make the VCB serviceable including making all electrical Connection and Testing ( IR Test, Continuity Test, Tripping test of earth fault and Over current of panel ) complete all as specified and directed by Engineer-in-charge. Note:- The Spare parts of VCB panel are measured and paid saperately as supply only.
Supply & Fxing Trip coil 110 Volt suitable for 11 KV VCB panel complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Closed coil 110 Volt suitable for 11 KV VCB panel complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Configureing TNC switch compatiable for 11KV VCB panel 10 Amps 440 volts including taking down old unserviceable complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Configuring remote switch compatible for 11KV VCB panle 32 Amps 440 Volts including taking down old unserviceable, complete all as specified and directed Engineer-in -Charge.
Supply & fixing Solid state relay IMDT type (02 O/C +01 EF) for 11 KV VCB panel, rating 5 Amps,Auxilliary supply 30 Volt DC complete all as specified and directed Engineer-in -Charge.
Supply & fixing Control cable of 10 core, 2.5 sqmm. complete all as specified and directed Engineer-in -Charge.
Repairing & testing of 33KV breaker mechanically type, 400 Amps, 36 KV, 3 phase, 50 Hz with shunt trip coil 110-volt DC volt 110 motor single phase 230 volt with replacement of burnt items and testing complete all as specified and directed by Engineer-in Charge.
Supply and Fix in repair Digital Volt Meter for 11/0.433 KV alongwith control wiring suitable for complete all as specified and directed by Engineer-in-charge.
Supply and Fix in repair Digital Amp Meter for 11/0.433 KV alongwith wiring suitable for complete all as specified and directed by Engineer-in-charge.
S&F in repair LED indicator (R,Y,B) for 11/0.433 KV,110 Volt, with control wiring complete all as specified and dirceted by Engr-in-charge.
Supply & Fix Four pole contactor 25 to 30 Amp including taking down old unserviceable contactor all as specified and directed by Engineer-in-charge.
Supply & Fix Four pole contactor 35 to 40 Amp including taking down old unserviceable contactor all as specified and directed by Engineer-in-charge.
Supply & Fix MCB, Triple Pole, 32 Amp including taking down old unserviceable all as specified and directed by Engineer-in-charge.
Supply & Fix MCB, Triple Pole, 40 Amp including taking down old unserviceable all as specified and directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 4 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 7 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 10 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 12 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 15 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement of unserviceable CT for LT with ratio (1000/5) all as per existing make by commissioning and installing complete all as specified and directed by Engineer-in charge.
Supply and fix in replacement of unserviceable CT for LT with ratio (1250/5) all as per existing make by commissioning and installing complete all as specified and directed by Engineer-in charge.
Servicing, Testing & Commissionig of all existing APFC Panel including all others connected accessories and complete wiring required at site all as directed by Engr-in-charge. Note: Spares parts replaced with new paid saperately.
Supply and fix in replacement of unserviceable Power factor Control relay for 12 stage all as per existing make by commissioning and installing complete all as specified and directed by Engineer-in charge.
vinayandsons
Anil Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .