Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 30 2 RAJKUMAR MUKHERJEE ROAD KOL 700035 | KOLKATA | KOLKATA | WEST BENGAL | 700035 | L1 | Accepted-AOC AOC | |
| 2 | L2₹11.6 L+₹35,928 (3.20%)Rejected-Finance 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹11.8 L+₹53,860 (4.80%)Rejected-Finance 150 276 K K RAM DAS ROAD NIMTA KOLKATA 700049 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700049 | L3 | Rejected-Finance Rejected as L3 |
Tender Value
Refer Docs
EMD Value
₹18,300
Closing Date
1 Oct 2024, 3:10 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Dist Hospital Campus Saktinagar Krishnagar Nadia
Renovation and Installation of some EI work at difft medical officers sister room compound area lighting arrangement in Chakdaha SGH Rattirer Sathi
2024_WBPWD_755504_1
WBPWD/EE/NED/Short NIQ/e-T/33/ (1st Call)24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Dist Hospital Campus Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹18,300
21 Nov 2024
21 Sept 2024
3 Oct 2024
21 Sept 2024
1 Oct 2024
21 Sept 2024
Amount
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC . Average Run 8 Mtr [1(iii)/ E-20 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with Modular type switch (Brand approved by E.I.C) as per GS. . On Board [3 (i) / E- 20]
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [9(a)/E-18] (For 6A Power Plug)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [9(b)/E-18]
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. [ 12/E-18 ] (For CB)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+12 Way [Siemens Enclosure(8GB32102RC14)/ Schneider Enclosure-(A9HSND12/Legrand Enclosure(607712) or equivalent model as per direction of EIC. [ 13 / D- 9 & D-10 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/ Schneider) as per direction of EIC. )
6 Way Make - Legrand, Enclosure-607716/Schneider, Enclosure-A9HTND06,etc) as approved E.I.C as approved by E.I.C [ 14 / D- 10 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand,etc as per direction of EIC. ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand,etc as per direction of EIC. ]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 as per GS
6 Way (Horizontal) [16/D-12]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ] ( for 6 A Plug)
2x(2.5 sqmm) + 1x(1.5 sqmm) [ 1(s) / E-9 ] ( for 16/20 A Power Plug,CB)
2x (6 sqmm) + 1x (4 sqmm) [1(y) / E- 9 ] ( for HTPN to SPNDB)
4x(10 sqmm)+2x (6 sqmm) [ 1(d1) / E- 9 ] ( for VTPN to HTPN)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [ 7(a)/ E- 16 ]
25 mm size [ 7(b)/ E- 16 ]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
175 mm x 100 mm x 65 mm [11(c)/E-4]
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required.
175 mm x 100 mm x 65 mm [12(c)/E-4]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
c) 4 sq mm [9(ii) / F-5]
d) 6 sq mm [9(iii) / F-5]
e) 10 sq mm [9(iv) / F-5]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex,Gloster,Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [1-a(i)/ E-14 ] ( for connection between loop box and light fittings )
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
1.5 Sqmm [9/F-5]
Supply of 4/3.5/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make- Gloster/KEI/Havells as approved by E.I.C]
2 Core 6 Sq.mm.
4 Core 10 Sq.mm.
4 Core 16 Sqmm
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [ 2(a)/ F- 1 ]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor / pavement/wall etc. [ 5(i)/ F- 3 ]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
upto 35 Sq. mm [1(a)/ F- 2 ]
Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings as per GS.
32 mm dia [11(b)/F-6]
40 mm dia [11(c)/F-6]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
2 Core 6 Sq. mm [7(a)/F4 ]
4 Core 10 Sq. mm [7(c)/F4 ]
4 Core 16 Sq. mm [7(c)/F4 ]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
2 Core 6 Sq. mm [8(b- ii) /F5]
4 Core 10 Sq. mm [8(b- xi) /F5]
4 Core 16 Sq. mm [8(b- xi) /F5]
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples etc. as required [ 14(C) /C-2 ]
Fixing only single/twin fluorescent/LED light fitting in the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [ 16/C-2 ]
Fixing only lamp [ 11/C-2]
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. [ 13/C-2]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS [ 22/D-13 ]
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent make CG / Bajaj / Wipro/ Magik] incl. 1 no. 18W Master LED Tube (with 2 years warranty)
Twin fittings [Philips make Cat No. TMC-501 P2xT-LED 22W P3242 or equivalent make CG / Bajaj / Wipro/ Magik] incl. 2 nos. 18W Master LED Tube(with 2 years warranty)
Supply of 12 W LED bulb (Philips/CG/Bajaj) on existing batten holder
Supply of 12W surface mounted LED bulkhead light fittings incl. connections as per direction of EIC. (Make-Phillips / CG / Wipro) (with 2 years warranty)
Supply & Fixing 240V, Modular Socket (2 Module) type BLDC fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E-18]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [ 21 (a) / C-3 ]
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [ 29/D-14 ]
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [29/C-4]
Fixing only exhaust fan after making holes in wall as per GS
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
30 cm Exhaust fan (12") [ 33/D-14 ]
Supply of ac ceiling fans of 1200mm sweep with burst-proof P2/S3 Capacitor complete with all accessories without regulator. BLDC 5 Star Ceiling fan without remote with 5 YEARS Warranty(Valid warranty card) (Make - Crompton ENERGION Riviera/Usha-Techno Air or equivalent model of Havells/CG/Orient as approved by E.I.C)
1200 mm Sweep
Supply of 450mm sweep wall bracket fan(high speed) with metal body & blades(Orient - Wall-II Tornado/Crompton WM SSTORM 2 or equivalent model) with necessary wooden board on wall with nuts, bolts, washer etc.
Supply of heavy duty Exhaust fans of following size complete with all accessorie (Make -EPC ) as per direction of EIC.
12"( 300mm ) Speed 920 RPM
S & F mini pole on roof top by 80 mm dia., 2 Mtr. Long GI pipe medium quality (Make-Bansal/Jindal/Subham Pole) as per GS.
Supply & Delivery of 7 Mtr Steel Tubular Pole (Calcutta poles/ Subham/ Transrail or other equivalent make as approved by E.I.C) as per specification Type 410 SP -3 as overall length 7 mtr weight 85kg. & having diamention are : Out side dia & thickness of the Bottom section ( 114.3x 4.50) mm; Middle;(88.9 x 4.85) mm ,Top Section (76.1 x 3.25 ) mm with fixing the base plate and GI earth bolt after making drilled holes etc. on pole as per direction of EIC
For providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box. [3(b-i)/H-1]
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts.above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly
Upto 9.0 mtr. Size 0.6x0.6x1.70 mts [1 (a)/ H- 1 ]
Dismantling the existing light fittings including necy. Inter connections with PVC insulated copper wire [NS]
Painting of Steel Tubular Pole of following lengths and 2 nos. of aluminium coats of paint over 1 coat of RO priming with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint
Upto 9 mtr. long pole [7 A.(a)(i+ii+iii)/ H- 2]
Painting Block Letters or Digits within a circle/square as required, with ”Black Japan” paint of approved make & brand, the size of letters and digits as given below
Size 40 mm and upto 50 mm [6(a)/H-2]
S & F 50 mm. dia 1.5 mtr. long detachable type G.I. Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC.(Make-Bansal/Jindal/Subham Pole) as per GS.
Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections & painting [H(4)/H-5] ( for the construction of structure at main entrance Gate name plate light purpose)
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting also including arthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
250 x 250 x 100mm [16(b)/I-2]
Supply & Fixing of 240V, 70/72 W LED Street light luminarie complete with all accessories and equipped with IP66 Protection, efficacy 120> lumen(Make- Philips/Bajaj ZELA P 86L WH PO TG SD/CG as approved by EIC) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. (5 years warranty with valid warranty card)
Supply & Fixing of 240V, 6~14 W Green Space Flex is a modular range of downlights luminarie complete with all accessories and equipped with IP66 Protection (Make- Philips/Bajaj/CG as approved by EIC) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. (5 years warranty with valid warranty card)
S&F of 250V 1-phase timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25A DPMCB (C-curve 10ka) and 1 no. 24 hr analog time switch and 1 no 22/25A 2pole power contactor complete with internal wiring with suitable size of copper wire including 1 no. toggle switch and 2 nos. LED indicator and earthing attachment as per direction of EIC. (For Compound light,street light & glow sign board)
Supplying and fixing 415V TPN with fuse on L&N on Sheet steel Enclosure Main Switches on flat iron frame on wall ( Make: L&T,as approved by EIC,etc.)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS. [4(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming for Morrum Soil. [1(b)/G-1]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [5(d)/G-3]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
No. 4 SWG [5(a)(i)/G-2 ]
Charges for making scaffolding arrangement by hiring materials and removing after work as required.(j1/7)
CHAKRABORTY ENTERPRISE (BID ID -5645923)
S.B.ENTERPRISE (BID ID -5639508)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .