Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹30.7 L Quoted ₹31.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹32.2 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹32.2 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹32.3 LRejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | ₹32.3 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹39.1 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹39.1 L | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹42.5 LRejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR PIN 361 005 | JAMNAGAR | GUJARAT | 361005 | ₹42.5 L | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | JAYESH TRADING CORPORATION L2 | Ravi enterprise L5 | M/s. Vimal Enterprise L7 | Sukhi Electricals L6 | Nitesh Enterprise L8 | JAMNAGAR ELECTRIC AND MACHINERY CO L4 | M/s Balaji Enterprise L3 | BHAVNA IMPERIAL ENTERPRISE L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed. | 250 | Cubic Metre | 400 ₹1 L | 300 ₹75,000 | 330 ₹82,500 | 350 ₹87,500 | 180 ₹45,000 | 330 ₹82,500 | 270 ₹67,500 | 188 ₹47,000 |
| 2.00 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and as directed. | 150 | Cubic Metre | 100 ₹15,000 | 100 ₹15,000 | 90 ₹13,500 | 65 ₹9,750 | 40 ₹6,000 | 80 ₹12,000 | 110 ₹16,500 | 35 ₹5,250 |
| 3.00 | Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. | 100 | Cubic Metre | 120 ₹12,000 | 120 ₹12,000 | 120 ₹12,000 | 75 ₹7,500 | 200 ₹20,000 | 150 ₹15,000 | 120 ₹12,000 | 35 ₹3,500 |
| 4.00 | M&L for cement concrete 1:3:6 type C1, using 20mm graded crushed stone aggregate as in copings, kneelers, apex stones, bed plates, pedestal of electric poles and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. | 1 | Cubic Metre | 6,500 ₹6,500 | 5,000 ₹5,000 | 4,500 ₹4,500 | 6,000 ₹6,000 | 8,200 ₹8,200 | 4,800 ₹4,800 | 4,200 ₹4,200 | 3,350 ₹3,350 |
| 5.00 | M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed. | 40 | Running Metre | 250 ₹10,000 | 800 ₹32,000 | 450 ₹18,000 | 1,200 ₹48,000 | 1,100 ₹44,000 | 800 ₹32,000 | 400 ₹16,000 | 188 ₹7,520 |
| 6.00 | M&L for filling approved dry river sand for cushioning and cover for protection of under ground electric cable in trenches 8 cm before laying cable and 15 cm deep over the cable and punning to 18 cm total thickness complete all as specified and as directed.
Notes :-
(i) Approved dry sand free from vegetations, grass and other deleterious substances shall be used.
(ii) For the purpose of payment, only punned thickness shall be measured. | 45 | Cubic Metre | 900 ₹40,500 | 1,250 ₹56,250 | 900 ₹40,500 | 1,250 ₹56,250 | 180 ₹8,100 | 1,000 ₹45,000 | 850 ₹38,250 | 680 ₹30,600 |
| 7.00 | Taking down carefully old existing HT PCC Cable Cover of Class EHV / HVP / HV of any type & size complete all as specified & as directed. | 1,200 | Each | 1 ₹1,200 | 2 ₹2,400 | 1 ₹1,200 | 1 ₹1,200 | 120 ₹1.4 L | 2 ₹2,400 | 1 ₹1,200 | 0.1 ₹120 |
| 8.00 | Laying only HT PCC cable covers of any type & size for protection of UG HT electric cables in trenches, obtained serviceable from serial item No. 7 here-in-above, complete all as specified & as directed. | 300 | Each | 1 ₹300 | 4 ₹1,200 | 1 ₹300 | 1 ₹300 | 150 ₹45,000 | 4 ₹1,200 | 1 ₹300 | 0.4 ₹120 |
| 9.00 | Supplying and laying un-reinforced precast cement concrete cable covers, Class HV, Type-1, Flat, size 300 mm x 180 mm x 40mm for protection of underground electric cable in trenches complete all as specified and as directed. | 900 | Each | 25 ₹22,500 | 28 ₹25,200 | 24 ₹21,600 | 27 ₹24,300 | 400 ₹3.6 L | 21 ₹18,900 | 19 ₹17,100 | 21 ₹18,900 |
| 10.00 | Taking down carefully old existing LT PCC Cable Cover of Class LV of any type & size complete all as specified & as directed. | 3,900 | Each | 1 ₹3,900 | 2 ₹7,800 | 1 ₹3,900 | 1 ₹3,900 | 100 ₹3.9 L | 2 ₹7,800 | 1 ₹3,900 | 0.1 ₹390 |
Updated dates
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
15 Apr 2026, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar
Maintenance and repair of VCBs/ Ring Main Units/ Distribution Transformers, LT Panels and connected works at INS Valsura, Jamnagar
2026_MES_757121_1
8937/VAL/E8
Open Tender
Electrical and Maintenance Works
335 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹86,000
Yes
8 May 2026
20 Mar 2026
17 Apr 2026
20 Mar 2026
15 Apr 2026
3 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed. | |||||
| 2Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and as directed. | |||||
| 3Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. | |||||
| 4M&L for cement concrete 1:3:6 type C1, using 20mm graded crushed stone aggregate as in copings, kneelers, apex stones, bed plates, pedestal of electric poles and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed. Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. | |||||
| 5M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed. | |||||
| 6M&L for filling approved dry river sand for cushioning and cover for protection of under ground electric cable in trenches 8 cm before laying cable and 15 cm deep over the cable and punning to 18 cm total thickness complete all as specified and as directed. Notes :- (i) Approved dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured. | |||||
| 7Taking down carefully old existing HT PCC Cable Cover of Class EHV / HVP / HV of any type & size complete all as specified & as directed. | |||||
| 8Laying only HT PCC cable covers of any type & size for protection of UG HT electric cables in trenches, obtained serviceable from serial item No. 7 here-in-above, complete all as specified & as directed. | |||||
| 9Supplying and laying un-reinforced precast cement concrete cable covers, Class HV, Type-1, Flat, size 300 mm x 180 mm x 40mm for protection of underground electric cable in trenches complete all as specified and as directed. | |||||
| 10Taking down carefully old existing LT PCC Cable Cover of Class LV of any type & size complete all as specified & as directed. | |||||
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
8937TENDER.pdf
Tender Documents • 1.07 MB
BOQ_848079.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid