Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H4₹6.1 L−₹2.9 L (31.0%)Accepted-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | H4 | Accepted-AOC H4 | |
| 2 | H1₹9.2 LRejected-AOC UPPER SARTHI VIHAR AJABPUR KALAN PO NEHRUGRAM HARIDWAR ROAD DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | H1 | Rejected-AOC H1 | |
| 3 | H2₹6.9 L−₹2.3 L (25.1%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | H2 | Rejected-AOC H2 | |
| 4 | H3₹6.8 L−₹2.5 L (27.0%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | H3 | Rejected-AOC H3 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
29 Jan 2025, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR / REPLCEMENT OF STREET LIGHT AND CONNECTED WORKS AT GBS CAMP, MT CAMP, OTM ACCN AND CSD COMPLEX AT KOTDWARA UNDER AGE (I) LANSDOWNE.
2025_MES_691232_1
8964/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AGE I Lansdowne
All as per NIT and Tender Documents
7 documents required · 7 mandatory
₹500
AGE I Lansdowne
₹20,000
Yes
19 Feb 2025
1 Jan 2025
31 Jan 2025
1 Jan 2025
29 Jan 2025
16 Jan 2025
Amount
Dismantling Old PCC Poles & Supplying and erecting in true vertical position steel tubular swaged pole, 8.5 meters long, type 410 SP-22, complete as per IS-2713 with MS iron base plate of 06mm with pole cap, finial taper plug , bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:4:8 type D2, (using 40mm graded stone aggregage) and PCC 1:3:6 type C2, (using 40mm graded stone aggregate) as in plinth block, disposal of surplus soil to a distance not exceeding 50 mtr, painting two coats of aluminium paint over one coat of red oxide primer including tarring one coat on steel surface embedded in concrete and 04 Nos strips of 250mm height from coping comprising & black yellow paint in alternative layer complete all as specified and directed. Note:- Required earth work, PCC foundation will be paid separetly under relevant items of Sch A.
M&L laying or passing through pipe LT UG XLPE PVC insulated,steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core including taking out old unserviceable cable complete all as specified and directed.
Supply and fixing bracket made out of 40mm bore, steel tubings, galvanised, light grade not less than 1.2 mtr long bend to shape with all fitting including fixed on pole with 02 Nos MS Clamp made out of F1 32x6mm complete all as specified and as directed.
Supply and fix in repairs new LED street/security light fitting 45W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy > 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge. Note: (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS & CRS no
Supply and fix in repairs new LED street/security light fitting 60W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy > 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K ncluding connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge. Note: (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS & CRS no
S & F Loop in and Loop out FRP rectangular SMC junction box (Pole Box) front openable hinged from side of size 240x130x110 mm suitable for outdoor installation weather proof having 4 pole cable connector (for cable in and out junction) fixed inside box with insulator support and 01 nos MCB SP 06 Amp fixed inside box complete for street light fitting with mS clamps 40x5 mm GI nuts, bolts and washers complete all as specified and directed.
Supply and fix in repairs LED flood light fitting 120W/150W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy > 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on pole of any type on existing angle iron with the help of nuts bolts washer including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge. Note: (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS & CRS no
Supply and fix in repairs LED flood light fitting 100W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 90 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy > 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on pole of any type on existing angle iron with the help of nujts bolts washer including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge. Note: (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS & CRS no
Supply and Fixing in repair LED driver with PF>0.95, input voltage 240 V AC, 50 Hz, input current 0.25 Amp AC, output voltage 42V-72V DC, output current 0.7A DC THD<10%, line volatge 140 to 277 V, IP 20 protection as per IS:15885(part-II section 13) suitable for LED street light of 25 Watt to 45 Watt outdoor dry and damp application after taking down the street light from pole/wall and refixing the street light on pole/wall (Size of driver should be as per sample given by EIC) complete all as specified and directed.
Supply and Fixing in repair LED driver with PF>0.95, input voltage 240 V AC, 50 Hz, input current 1.6 Amp AC, output voltage 42V-72V DC, output current 0.7A DC THD<10%, line voltage 140 to 277 V, IP 20 protection as per IS:15885(part-II section 13) suitable for LED street/Flood light of 50 W to 90Watt outdoor dry and damp application after taking down the street light from pole/wall and refixing the street light on pole/wall (Size of driver should be as per sample given by EIC) complete all as specified and directed.
Excavation in trenches in any type of soil n.exc 1.5 m wide and n.exc 1.5 m in depth for poles,laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed.
Returning filling in any type of soil including spreading, levelling, watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus any type of soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid.
M&L for burnt bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
M & L, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in mass concrete/foundation complete all as specified and directed.
M & L PCC 1:4:8, type D2, ( using 40mm graded stone aggegate) as in foundation and posts including caps and bases complete all as specified as directed.
S&F garden lithts integral decorative LED bollard with opal acrylic with IP-65 protection including connector to connect the cable and all necessary accessories all as specified and directed. Note:- Necessary excavation and PCC work for Bollard lights fittings deemed to be inculded in quouted rates.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.00 sq mm 2 core complete as specified and directed.
JS CONSTRUCTION COMPANY (BID ID -3226998)
Bedi Refrigeration Works (BID ID -3226395)
AJAY KUMAR CONTRACTOR (BID ID -3217748)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .