Loading…
Loading…
Tender ID
Tender Value
₹33.6 L
EMD Value
₹50,000
Closing Date
20 Apr 2026, 11:00 amClosed
The Regional Project Director
Kerala Rural Water Supply and Sanitation Agency, Regional Project Management Unit, Malappuram, MMC.X/108-112, UMK Tower, Uphill, Jubilee Road, Near Passport Office, Malappuram P.O. - 676 505
Sustainability Support to Community Managed Water Supply Schemes - 2025-26 - Rehabiltation and rennavation of Safa WSS, Mulayathkulamb WSS, Kalakappara WSS and Ambedkar WSS in Puzhakkattiri GP, Malappuram district
2026_KRWSA_834509_1
KRWSA/MPM/SUS/PZK/25-26/01
Open Tender
Civil Works - Water Works
Item Rate
120 days
Puzhakkattiri GP in malappuram district
As per Standard bid document
7 documents required · 7 mandatory
₹2,500
₹50,000
7 Feb 2026
7 Feb 2026
21 Apr 2026
7 Feb 2026
20 Apr 2026
7 Feb 2026
7 Feb 2026 - 20 Apr 2026
APPENDIX A - SAFA WSS
PUMP SET & ACCESSORIES a) Pump & Motor "Supply, erection, testing and commissioning of KWA pre-qualified reputed make open well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl/ Diffuser with ISI mark. The pump shall be directly coupled to a continious rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283/ 1995 as amended thereafter, siutable for operation in AC 3 phase 380 V + /- 10%, 50 Hz + / - 5%, Duty Conditions : Discharge - 2.9 lps Total Head - 109 m b)Starter :- Supply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor c) Panel board :- Supply, erection, testing and commissioning of one number open board - single sheet type control panel board, suitable for providing control system for running motor pump set, suitable capacity Main Switch, DOL starter supplied, provided with a common earth for the entire panel as per IE rules and code of practice. The panel shall be fitted on the Wall or seperate MS Support to prevent any wetness, moisture, allowing sufficient free space for wiring, air circulation in back side of board with proper support on wall or support, including necessary plastering patch works, concrete works d) Cabling work :- Supply, laying, testing and commissioning Flat submersible Copper Cable not below 4 sqmm for wiring between Main switch, Starter, Motor pump set considering energy conservation, including additional length allowance as loop for future repaire as per the direction of Engineer. e) Earthing :- "Supply of all materials and providing suitable earthing by using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards." f) Capacitor :- "Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834" g) Valves :- "Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non retum valve of 50 mm or dia of pumping line 1.60 PN pressure rating. Fitting of valves shall include proper RCC support for Non return valves and Sluice Valves of reputed make. " h) Pressure Gauge :- Supply of suitable size best quality heavy duty ISI marked Pressure Gauge with controll Valve i) Suction and delivery pipe connections :- Supply and fitting of dia. not below 50 mm dia. according to pump discharge, best quality C class GI erection pipe for a total length of 10 m suitable for the above pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flanged joints to withstand the heavy load and for facilitating lifting and erection of motor) and connecting the delivery side of the pump with the valves and suitable specials, including cutting, welding, jointing to link the line with existing pumping main near well. j) General Conditions :- Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessories supplied.
DISTRIBUTION SYSTEM Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock
Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 50 mm nominal outside diameter pipes
Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes
Supply of PVC Pipe, 10kg/cm2, 50mm Dia.
Supply of PVC Pipe, 10kg/cm2, 63 mm Dia.
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge. Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
WATER QUALITY Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Engaging Coolie.
Engaging Fitter ( grade 1).
Lettering with black Japan pint of approved brand and manufacture
Supplying and laying upvc pipe specials for 50mm dia uPVC pipe with class 10kg/cm2 or higher@ 3% rate of cost of pipes
Supplying and laying upvc pipe specials for 63 mm dia uPVC pipe with class 10kg/cm2 or higher@ 3% rate of cost of pipes
APPENDIX B-MULAYATHKULAMB WSS
PUMP HOUSE :- Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHard drawn steel wire fabric
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreHorizontal
Lettering with black Japan pint of approved brand and manufacture
WATER QUALITY Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters.
PUMPSET AND ACCESSORIES a)Pump & Motor "Supply, erection, testing and commissioning of KWA pre-qualified reputed make open well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl/ Diffuser with ISI mark. The pump shall be directly coupled to a continious rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283/ 1995 as amended thereafter, siutable for operation in AC 3 phase 380 V + /- 10%, 50 Hz + / - 5%, Duty Conditions : Discharge - 1.96 lps Total Head - 196 m b)Starter :- Supply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor c) Panel board :- Supply, erection, testing and commissioning of one number open board - single sheet type control panel board, suitable for providing control system for running motor pump set, suitable capacity Main Switch, DOL starter supplied, provided with a common earth for the entire panel as per IE rules and code of practice. The panel shall be fitted on the Wall or seperate MS Support to prevent any wetness, moisture, allowing sufficient free space for wiring, air circulation in back side of board with proper support on wall or support, including necessary plastering patch works, concrete works d) Cabling work :- Supply, laying, testing and commissioning Flat submersible Copper Cable not below 4 sqmm for wiring between Main switch, Starter, Motor pump set considering energy conservation, including additional length allowance as loop for future repaire as per the direction of Engineer. e) Earthing :- "Supply of all materials and providing suitable earthing by using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards." f) Capacitor :- "Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834" g) Valves :- "Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non retum valve of 50 mm or dia of pumping line 1.60 PN pressure rating. Fitting of valves shall include proper RCC support for Non return valves and Sluice Valves of reputed make. " h) Pressure Gauge :- Supply of suitable size best quality heavy duty ISI marked Pressure Gauge with controll Valve i) Suction and delivery pipe connections :- Supply and fitting of dia. not below 50 mm dia. according to pump discharge, best quality C class GI erection pipe for a total length of 10 m suitable for the above pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flanged joints to withstand the heavy load and for facilitating lifting and erection of motor) and connecting the delivery side of the pump with the valves and suitable specials, including cutting, welding, jointing to link the line with existing pumping main near well. j) General Conditions :- Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessories supplied.
OHSR Providing and applying Dr.Fixit, classic Damp Guard, of Pedilite brand/ Araldite Builder Barrierkot Epoxy / Nitocote EP405 water proof coating for waterproofing treatment to the RCC structures like retaining walls, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels, / subway and bridge deck etc., prepared by mixing the 1 Part Base & 1 Part Hardener and one part water and applying the same on the internal plastered surface, 2 coats, with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The work shall be carried out all complete as per specification and the direction of the engineer in-Charge. The product performance shall carry guarantee for 10 years against any leakage
12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1cement : 3 fine sand)
DISTRIBUTION SYSTEM Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock
Supply of PVC Pipe, 10kg/cm2, 63mm Dia
Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
Supplying and laying upvc pipe specials for 63mm dia uPVC pipe with class 10kg/cm2 or higher@ 3% rate of cost of pipes
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Engaging Coolie.
APPENDIX C - KALAKAPPARA WSS
OHSR Demolishing lime concrete manually / by mechanical means and disposal of material within 50 metres lead as per direction of Engineer - in- Charge.
Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In Lime Mortar
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All work upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3(1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All work above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Lettering with black Japan pint of approved brand and manufacture
12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
Providing and fixing 1 mm thick M.S. sheet sliding- shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junction and corners, 25 mm dia pulley, 40x40x6 mm angle and T-iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
WATER QUALITY Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters.
PUMPSET AND ACCESSORIES a)Pump & Motor "Supply, erection, testing and commissioning of KWA pre-qualified reputed make open well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl/ Diffuser with ISI mark. The pump shall be directly coupled to a continious rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283/ 1995 as amended thereafter, siutable for operation in AC 3 phase 380 V + /- 10%, 50 Hz + / - 5%, Duty Conditions : Discharge - 2.56 lps Total Head - 74 m b)Starter :- Supply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor c) Panel board :- Supply, erection, testing and commissioning of one number open board - single sheet type control panel board, suitable for providing control system for running motor pump set, suitable capacity Main Switch, DOL starter supplied, provided with a common earth for the entire panel as per IE rules and code of practice. The panel shall be fitted on the Wall or seperate MS Support to prevent any wetness, moisture, allowing sufficient free space for wiring, air circulation in back side of board with proper support on wall or support, including necessary plastering patch works, concrete works d) Cabling work :- Supply, laying, testing and commissioning Flat submersible Copper Cable not below 4 sqmm for wiring between Main switch, Starter, Motor pump set considering energy conservation, including additional length allowance as loop for future repaire as per the direction of Engineer. e) Earthing :- "Supply of all materials and providing suitable earthing by using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards." f) Capacitor :- "Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834" g) Valves :- "Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non retum valve of 50 mm or dia of pumping line 1.60 PN pressure rating. Fitting of valves shall include proper RCC support for Non return valves and Sluice Valves of reputed make. " h) Pressure Gauge :- Supply of suitable size best quality heavy duty ISI marked Pressure Gauge with controll Valve i) Suction and delivery pipe connections :- Supply and fitting of dia. not below 50 mm dia. according to pump discharge, best quality C class GI erection pipe for a total length of 10 m suitable for the above pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flanged joints to withstand the heavy load and for facilitating lifting and erection of motor) and connecting the delivery side of the pump with the valves and suitable specials, including cutting, welding, jointing to link the line with existing pumping main near well. j) General Conditions :- Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessories supplied
PUMPING MAIN Providing and fixing G.I. pipes (Medium) complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore
Providing and fixing G.I. pipes (Medium) complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore
DISTRIBUTION SYSTEM Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
Supply of PVC Pipe, 10kg/cm2, 63mm Dia.
Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
Engaging Coolie.
Providing and fixing G.I. pipes (Medium) complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall50 mm dia nominal bore
APPENDIX D -AMBEDKAR WSS
PUMPING MAIN Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock
Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes
Supply of PVC Pipe, 10kg/cm2, 63mm Dia
Supplying and laying upvc pipe specials for 63mm dia uPVC pipe with class 10kg/cm2 or higher@ 3% rate of cost of pipes
Providing and fixing G.I. pipes (Medium) complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore
Providing and fixing G.I. pipes (Medium) complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall50 mm dia nominal bore
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Lettering with black Japan pint of approved brand and manufacture
SOURCE Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
WATER QUALITY Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters.
PUMP HOUSE Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreHorizontal
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
Engaging Coolie.
Engaging Fitter ( grade 1).
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Old work (one or more coats)
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
Percentage of applicable GST
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
tenderpuzha.pdf
Tender Documents • 6.72 MB
BOQ_1403735.xls
BOQ • 0.36 MB
formats.pdf
Other Document • 0.16 MB
corri70426.pdf
PDF • 0.44 MB
corri310326.pdf
PDF • 0.44 MB
corre23326.pdf
PDF • 1.15 MB
corri16march.pdf
PDF • 0.45 MB
corri2.pdf
PDF • 0.44 MB
corri.pdf
PDF • 0.27 MB
corri.pdf
PDF • 0.09 MB
corregendumtimeextension.pdf
PDF • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .