Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC GSTIN: 16ABZPD9185F1Z2NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | ₹6.1 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical GSTIN: 16AAFFR6026C1ZJJOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical L3 |
| 3 | Rejected-Technical GSTIN: 16AGDPP4101E1ZY31 A K ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | R.P.ELECTRONICS L3 | Eastern Commerce L1 | STANDARD ELECTRONICS L2 |
|---|---|---|---|---|---|---|
| 1.00Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity | ||||||
| 1.01 | 1.5 TR split type high wall AC machine (Minimum rated cooling capacity should be 4500 Kcal/hr or 18000 BThu/hr or 5250 watt). | 6 | No | 36,100 ₹2.2 L | 35,890 ₹2.2 L | 39,000 ₹2.3 L |
| 1.02 | 2.0 TR split type high wall AC machine (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 Bthu/hr or 7000 watt) | 6 | No | 54,500 ₹3.3 L | 51,800 ₹3.1 L | 52,000 ₹3.1 L |
| 2.00 | Standard installation, testing and commissioning of 1.5/2.0 TR split including hole cutting, finishing etc as per direction of the Engineer-in-charge. | 12 | No. | 4,000 ₹48,000 | 1,600 ₹19,200 | 3,000 ₹36,000 |
| 3.00 | Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 1.5TR/2.0TR split AC as per manufacturer guideline ( 5/8” and 1/4” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units. | 60 | Mtr | 500 ₹30,000 | 550 ₹33,000 | 400 ₹24,000 |
| 4.00 | Fabrication of M.S platform for placement of condensing unit by using M.S angle of (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. | 12 | No. | 2,000 ₹24,000 | 800 ₹9,600 | 1,200 ₹14,400 |
| 5.00 | Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. | 150 | Mtr | 100 ₹15,000 | 140 ₹21,000 | 127 ₹19,050 |
Tender Value
₹7.5 L
EMD Value
₹15,054
Closing Date
25 Apr 2025, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division Agartala
Providing Installation Testing and Commissioning of split type air conditioning system in different rooms of Revenue Department 1st floor Secretariat Building Agartala
2025_CEPWD_60236_1
116_EE_DNIeT_MECH DIVN_AGT 2024_25
Open Tender
Electrical Works
60 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹15,054
2 Jun 2026
10 Apr 2025
25 Apr 2025
10 Apr 2025
25 Apr 2025
10 Apr 2025
Amount
Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity
1.5 TR split type high wall AC machine (Minimum rated cooling capacity should be 4500 Kcal/hr or 18000 BThu/hr or 5250 watt).
2.0 TR split type high wall AC machine (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 Bthu/hr or 7000 watt)
Standard installation, testing and commissioning of 1.5/2.0 TR split including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 1.5TR/2.0TR split AC as per manufacturer guideline ( 5/8” and 1/4” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units.
Fabrication of M.S platform for placement of condensing unit by using M.S angle of (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
STANDARD ELECTRONICS (BID ID -173827)
R.P.ELECTRONICS (BID ID -172916)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_61259.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid