Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC Admitted Found Reasonable for Acceptance | |
| 2 | L2₹16.3 L+₹1.7 L (11.3%)Rejected-AOC JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L2 | Rejected-AOC Rejected L1 being accepted | |
| 3 | L3₹16.6 L+₹1.9 L (12.8%)Rejected-AOC CHENNAMKULATHI HOUSE ARAKKUNAM PO DIST ERNAKULAM KERALA 682313 | ARAKKUNAM | ERNAKULAM | KERALA | 682313 | L3 | Rejected-AOC Rejected L1 being accepted | |
| 4 | L4₹16.7 L+₹2.0 L (13.9%)Rejected-AOC | L4 | Rejected-AOC Rejected L1 being accepted |
Tender Value
₹18.6 L
EMD Value
₹37,100
Closing Date
3 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum - 06
As per Tender Documents
2020_MES_394229_1
GE (ARMY) TVM 9359/E8
Open Tender
Civil Works
Item Rate
180 days
Trivandrum
As per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹37,100
Yes
9 Feb 2021
10 Nov 2020
5 Dec 2020
11 Nov 2020
3 Dec 2020
20 Nov 2020
11 Nov 2020 - 19 Nov 2020
60 days
Amount
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
Material and labour for 20 mm thick granite (of any type) work (tabled rubbed and polished) in steps, jambs, pillars, window-cills, cooking platform and like in 20mm thick cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including edges griding and polishing complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, remov-ing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engr-in-charge.
Material and labour for 10 mm thick rendering in cement mortar 1:4 on fair faces of concrete surfaces for backing of tiles all as specified and directed.
Material and labour for Non skid ceramic tiles 7 to 8 mm thick (square/Rectangular ) area of each tiles exceeding 0.11 Sqm but not exceedng 0.18 sqm, as in floors etc, set and jointed neat cement slurry and pointed with colour cement to match complete all as specified and directed.
Material and labour for Glazed ceramic tiles in verticle surfaces 450x300x7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and as directed.
Roughening surfaces of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and Supply and fix Non skid ceramic tiles 7 to 8 mm thick area of each tiles exceeding 0.18 Sqm but not exceedng 0.38 sqm (min size 600x600mm) in floors etc, set and jointed by applying adhesive as per manufacturers instruction on throughly dried surface and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-charge.
Material and labour for Non skid ceramic tiles 7 to 8 mm thick area of each tiles exceeding 0.18 Sqm but not exceedng 0.38 sqm, as in Skirting etc, set and jointed neat cement slurry and pointed with colour cement to match with existing surface complete all as specified and directed.
Taking down cement plaster, any description, on brick or stone walls or concrete surface, etc. including raking out joints hacking for key, scrubbing down with water etc. complete all as specified and directed by Engr-in-charge.
Material and labour for 15 mm thick screed bed in cm 1:6 for laying floor finishes (Upto four storey building) complete all as specified and directed.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each and re-fixing after repair in same opening complete all as specified and directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each including all metallic fittings and removing from site, complete all as specified and directed by Engr-in-charge .
Supply and fix Factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ' C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rails and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to in stiles & rails with suitable PVC sheet beading and joinned together with solvent cement supplying & fixing in frames at site as per specification and drawing shown in SSR Part -II, complete all as specified and directed by Engr-in-charge.
Supply and fix Solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supply & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and directed by Engr-in-charge.
Supply and fix Aluminium anodised, Butt hinges 100mm long complete all as specified and directed by Engr-in-charge.
Supply anf fix Aluminium handles, cast type, anodised of size 150 mm long, complete all as specified and directed by Engr-in-charge.
Suppply and fix Aluminium, anodised, barrel tower bolts of extruded section, 150 mm long, complete all as specified and directed by Engr-in-charge.
Material and labour for 3 mm thick sheet glass ordinary quality, and glazing with oil putty in squares n.exc 0.50 Sqm in each pane,complete all as specified and directed by Engr-in-charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame glazed with putty etc, complete all as specified and directed by Engr-in-Charge.
Material and labour for Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples, (fixed in repairs), complete all as specified and directed by Engr-in-charge.
Material and labour for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cm 1:6 isolated width,finished even and smooth (without using extra lime or cement) complete all as specified and directed.
Material and labour for Preparing new plastered surface,priming with chalk whiting and applying two coats of OBD on walls complete all as specified and directed.
Material and labour for Rendering 10mm thick in CM 1:3 on fair faces of brick work or concrete surfaces on ceiling, finished even and smooth w/o using extra cement, complete all as specified and directed by Engr-in-Charge.
Material and labour for Preparation of new plastered or unplastered surfaces in ceiling and applying two coats of white wash,complete all as specified and directed by Engr-in-charge.
Material and labour for Preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed by Engr-in-Charge.
M&L for Applying one coat of acrylic exterior emulsion water proofing painting including prepartion of old surfaces of wall (up to four storey bldg) as per manufactures instructions ) complete all as specified and directed.
Material and labour for Washing,rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper to wall including preparation of surfaces complete all as specified and directed.
Material and labour for Preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint (upto four storey building) complete all as specified and directed.
Material and labour for Preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint (upto four storey building).
Material and labour for Brooming down and preparing old surfaces of walls and applying one coat of white wash on old decorated surfaces complete all as specified and directed.
Material and labour for Mild steel framed work such as grills, gratings with ends of bars shouldered or reveted or forged into spikes, framed guard bars, barred Iron doors ladders, framed balusters, walk ways railings, frame work of water tanks and similar works concorming to Fe-290, Gde E-165, (fixed in repair) complete all as specified and directed by Engr-in-charge.
Material and labour for Preparation of new steel surfaces of any description not otherwie described, over 10 cm width or girth and applying two coats of synthetic enamel paint over red oxide, complete all as specified and directed by Engr-in-charge.
Supply and fix in repairs for viterous china, squating pan water closet, orissa pattern, size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including PVC 'P' or 'S' trap and cement concrete and jointing to flush pipe complete all as specified and directed.
Supply and fix in repair 10 ltr capacity PVC, low level, valveless, syphonic action type flushing cistern, inlet ball valve, float valve, handle and fixing arrangement, 32mm dia PVC flushing pipe and 15mm dia 450mm long PVC connection with CP brass coupling nuts and PVC washer at both ends,complete all as spfd and directed by Engr-in-Charge.
Supply and fix 15mm bore UPVC tubing incls taking down the pipe etc complete all as specified and directed.
Supply and fix in repair 20 mm bore UPVC tubing incls taking down the pipe etc complete all as specified and directed.
Supply and fix in repair PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls/ floors including necessary brackets all as specified and directed (Upto four storey building).
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Material and labour for 75mm thick Cement concrete type C2-2, 1:3:6 (40mm graded aggregate)finished even and smooth without using extra cement complete all as specified and directed.
Demolition of stone/boulder masonry built in cement mortor complete all as specified and directed.
Material and labour for Pre-Cast Cement Concrete block masonry type C1, 1:3:6 (using 20mm graded aggregate) with solid blocks exc 10 cm in width and setting in CM 1:4 complete all as specified and directed.
Supply and fix in repair PVC connection 15mm dia 450mm long with 02 Nos brass check nuts with washer etc complete all as specified by Engr -in-Charge
S&F in repair Bib tap fancy type chromium plated 15mm dia with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Supply and fix in repair towel rail 20 mm dia, D type 60 cm long of brass Chromium plated complete all as specified and directed.
Supply and fix in repairs Stop valve 15 mm dia, fancy type chromium plated screwed down, high pressure with long shank and cup screwed both ends for unions and fixed, all as specified by Engineer -in-Charge.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
Dismantling of timber scantlings 40 Sqcm and over in section as in unframed work in any position completecomplete all as specified and directed.
M&L Providing plain cement concrete 1:2:4 type B1 as in bed plates etc complete all as specified and directed.
M&L for steel work in tubular trusses/square or rectangular hallow mild steel section for structural use incl special shaped washer etc completed using ERW or induction butt welded tubes confirming to IS 1161-1979 graded St-240 complete all as specified and directed.
M&L Treating surfaces of ends of post etc area n.exc 0.1 sq.m each tretad with tar or coal tar black paint complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based mangaloe pattern corrugated steel sheeting, 0.50 mm thick, of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and directed.
M&L for two coat of synthetic enamel paint over a coat zinc chorome primer, incl preparing new steel surfaces any description, over 10 cm width or girth, not otherwise described complete all as specified and directed.
M&L for Brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Rendering 15mm thick on fair faces of brick work or concrete surface in cement plaster 1:4 complete all as specified and directed.
M&L Preparing new plastered surface and applying two coats of Oil bond distemper over a coat of chalk whiting or primer complete all as specified and directed.
Dismantling of wall and ceiling boards or insulation boards any thickness including cover fillets etc complete all as specified and directed.
S&F Non Asbestos decorative type fibre cement building boards , 4 mm thick fixed or laid / inserted to timber / GI / Aluminum frame work with screws on ceiling complete all as specified and directed.
M&L For Anodised aluminum snap grid frame work for false ceiling size 605 x 605 mm complete all as specified and directed.
S&F Plain mild steel wire 2.5 mm dia galvanised class 3 in detached work sutch as for mosquto nets and fixing to straining bolts, hook, eye, etc complete all as specified and directed.
Surface dressing n exc 15 cm deep in hard/denes soil complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for fdn and steps and getting out in hard/dense soil complete all as specified and directed.
M&L Plain cement concrete 1:4:8 Type D-2, using 40 mm graded stone aggregate as in foundation complete all as specified and directed.
Returning filling in including spreading, leveling,watering well ramming in layers n.exc 25cm thick using excavated soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceed 1.5 m above the starting point complete all as specified and directed.
Rendering 15 mm thick cement plaster on fair faces of brick work/concrete in cement mortar 1:4, finished even and smooth with out using extra cement complete all as specified and directed.
M&L Hardcore guage exc 63 mm n.exc. 100 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled / rammed to a true surface. Broken stone or Boulders complete all as specified and directed.
M&L cement concrete type B1, 1:2:4 (20mm graded Aggregate) 100 mm thick. finished with cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.
S&F rotational moulded polythylene water storage tanks (500Ltr) (Cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed
S&F Ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed (20mm) complete all as specified and directed.
S&F in repair UPVC pipe 15mm bore pressure rating 10kgf/CM2 fixed complete to walls, ceiling or in floors etc any type of pipe inlcuding taking down existing etc complete all as specified and directed.
S&F in repair UPVC pipe 20mm bore pressure rating 10kgf/CM2 fixed complete to walls, ceiling or in floors etc any type of pipe inlcuding taking down existing etc complete all as specified and directed.
S & F Stop valve cast copper alloy,screwed down, high pressure fancy type chromium plated both ends for 15mm dia iron pipe or for unions and fixed, all as specified by Engineer -in-Charge.
S & F Stop valve cast copper alloy,screwed down, high pressure fancy type chromium plated both ends for 20mm dia iron pipe or for unions and fixed, all as specified by Engineer -in-Charge.
M&L for RCC 1:2:4,type B1 (20mm graded aggregate) for slab supported on walls, beams and columns in floor , roofs , landings balconies etc complete all as specified and directed.
Form work to it soffits of roof slab,not.exc 200mm thick ,for fair finished flat surfaces of concrete complete all as specified and directed.
M&L TMT bars in reinforcement 8 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
M&L Plain cement concrete 1:3:6 Type C2 (using 40 mm graded stone aggregate) as in sub base in 100mm thick all as specified.
Sand filling/cushioning under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine pressed precast concrete interlocking coloured paver block any shape and size confirming to IS 15658-2006 of 100mm thickness , M-50 Grade with grey cement and pigment complete all as specified and directed.
M&L for PCC type B1 1:2:4 ( 20 mm graded aggregate in kerbs or mud stops rounded or chamfered edges etc complete all as specified and directed.
Taking down carefully existing unserviceable copper/aluminium point wiring (Light, fan, socket or power) with complete fittings, fixtures and pendant, regulator, switches, lamp holders, switch sockets etc. including making good to disturbed surface/concealed in wall/ceiling/floors etc by colouring with existing matching colour, filling of putties complete all as specified and directed
Point wiring complete for One light point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded, copper conductor in and including non-metalic PVC conduit totally concealed in wall with recessed, pressed steel terminal boxes not less than 1.2 mm thick concealed etc, incl plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing switches, socket outlets, fan regulators etc, incl provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as specified and directed NOTE: Pressed steel terminal boxes concealed in wall with suitable 3mm thick laminated sheet cover plate for mounting switch/sockets etc are deemed to be included in the quoted rate
All as per ser item No. 85 above but for One fan point controlled by one way switch and regulator
All as per ser item No. 85 above but for One light point controlled by two 2-way switches independent.
All as per ser item No.85 above but for One bell/buzzer point controlled by one bell push button independent.
All as per ser item No. 85 above but for one 5 Amps outlet on same board with other switches/sockets
All as per ser item No.85 above but for one 5 Amps socket outlet on independent board.
All as per ser item No.85 above but point wiring with 2.5 Sqmm FRLS cable and 2.5 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board.
S&F switch piano, flush type, single pole, one way 5 Amp, 240 volt, white or ivory ISI marked complete all as specified
All as per ser item No. 92 above but for switch 2 way 6A
Supply and fix bell push, flush type, single pole, one way, 5 Amps, 240 Volts all as directed
Supply and fix stepped type electronic fan regulator, 60 Watts, flush type 240 Volts, 50 Hz, suitable for ceiling fan 1200 mm/1400 mm sweep all as directed
Supply and fix switch socket outlet 5 pin, 5 Amps, 240 volts complete all as specified
Supply and fix switch socket combination 2 in 1, 5 pin, 5 Amps flush type 240 volts, white or ivory ISI marked complete all as specified
Supply and fix switch socket combination 2 in 1, 5 pin, 5/15 Amps flush type, universal, 240 volts, white or ivory ISI marked complete all as specified
Supply and fix ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65x50 mm three terminal complete all as directed Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree/Indoasian
Supply and fix Lamp holder angular type, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as directed
Supply and fix buzzer, Ding Dong, AC, 240 Volts, single pole all as directed
Supply and fix distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, TPN 4 way, 415 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCB SPN, SP etc, including taking down existing unserviceable one and removing from site complete all as specified and directed
All as per ser item No. 102 above but for SPN 8, 240 volts grade with 200 Amps insulated rated busbar
Supply and fix MCB single pole 5 to 32 Amps, 240 volt, 10 KA, C curve with IP-20 protected terminals including contact indication window for visual indication and safety of operator, IP-20 protection, energy limitation Class-3, airflow channels on both sides, bi-connect terminals etc., complete all as specified and directed
All as per ser item No. 104 above but for MCB SPN 25 to 32 Amps
All as per ser item No. 104 above but for MCB TPN 40 to 63 Amps
Supply and fix sub main wiring with 2 runs of 4 sqmm single core PVC insulated, FRLS, unsheathed cable with stranded copper conductor, 1100 Volts grade drawn through and including non metalic PVC conduit with all fitting such as Tee, Bends, Elbow, etc., fixed concealed in wall including 4 Sqmm multistranded PVC insulated, FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly complete. NOTE: Two runs of 4 sqmm copper cable and one run of 4 sq mm copper cable alongwith non metallic PVC conduit will be measured as one length
Material and labour for Earthing complete in replacement with galvanised iron mild steel earth plate electrode 60 cm x 60 cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to glavanised earthwire 4mm diameter by means of GI Bolts, Nuts, check nuts and washers including earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab 50 mm thick with 8 mm CTD bars reinforcement both ways at 140 mm centre to centre with two handles, 20 mm dia GI pipe medium grade for watering pipe , wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm and 15 mm dia light grade GI pipe for protection of earth wire from earth plate to MCB DB including necessary earth work in soft/loose soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr and testing on completion complete all as shown in electrical plate No-3 as specified and directed.
Dismantling and taking down carefully existing serviceable tube light fittings of any type or wattage including tube rod, removing materials from wall/ceiling for keeping in safe custody, refixing the same at its original location after wiring, including making electric connection from connector to light fittings & connecting up, testing the same for smooth operation complete all as specified and directed
Taking down carefully existing serviceable Ceiling fan, ceiling cable end, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rod after rewiring including clamps, hooks, holdfasteners etc and connecting up, including making electric connection from ceiling rose or connector to fan complete all as directed
Taking down carefully existing serviceable exhaust fan, ceiling cable end, etc., removing the fan for keeping in safe custody, fixing the exhaust fan connecting up after rewiring, including making electric connection from ceiling rose/connector to fan complete all as directed
Supply, installing, commissioning, testing of deep freezer, more than 400ltrs capacity, 230 volt, 50 Hz, aesthetic design, auto temperature control, energy efficient, having double hard top door, with anti bacteria gasket & rotary compressor including stucco aluminium inner liner for improved hygiene, spring loaded hinges with temperature range<-18 degree celicius complete all as specified and directed. Make:- Voltas or equivalent in Blue Star/Samsung/Godrej/LG.
Supply and install voltage stabilizer for automatic operation with digital voltmeter to monitor in/out voltage with time delay and bypass switch, signel phase, thermal overload protection, low & high voltage cut off protection, LED indication, IC controlled, naturally air cooled indoor type and design for input variation btween 170 volts to 250 volts with output voltgae stabilizer at 230V with accuracy of +2.5% an of capacity 4KVA complete all as specified and directed. Make:- V-Guard or equivalent in Microtek/Brenfort
Point wiring complete one 3 pin socket outlet, 15 Amps on independent board with 2.5Sqmm single core PVC insulated unsheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including PVC casing-capping minimum 25mm wide with all fittings and accessories such as bends, tees, joints etc fixed to wall or ceiling with recessed, pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing switch, sockets etc including provn of 2.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volts grade, multi stranded single core green colour copper conductor for earth continuity connected to earth dolly, all metal parts, such as tube light fittings fand hook earth terminal of all socket points etc all as specified and directed. NOTE:- (a) Pressed steel terminal boxes concealed in wall with suitable 3 mm thick laminated sheet cover plate for mounting switch/sockets petc are deemed to be included in the quoted rate. (b) Electric fittings/fixtures such as switch, socket etc shall be measured and paid seperately under relevant item. Make:- Havells or equivalent make of Plaza/Finolex/V-Guard.
Supply and fix switch socket combination 2 in 1, 5/15Amps flush type, universal, 240 volts, white or ivory ISI marked complete all as specified. Make:- Anchor or equivalent make of Havells/Legrand/Indoasian.
JEETH CONSTRUCTION
M/S AARJAY ASSOCIATES
KENZ CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .