| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹33.8 L+₹56,985.25 (1.71%)Rejected-AOC LANE NO 11 HOUSE NO 4 INDRAPRASTHA COLONY UPPER NATHANPUR RING ROAD DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹34.2 L+₹93,321.25 (2.81%)Rejected-AOC | L3 | Rejected-AOC AOC rejected. | |
| 4 | L4₹34.8 L+₹1.6 L (4.78%)Rejected-AOC | L4 | Rejected-AOC AOC rejected. | |
| 5 | L5₹36.6 L+₹3.4 L (10.1%)Rejected-AOC D 89 SHASTRI NAGAR MEERUT UTTAR PRADESH PIN 250004 | MEERUT | MEERUT | UTTAR PRADESH | 250004 | L5 | Rejected-AOC AOC rejected. |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
15 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Addn/ altn of damaged balconies of TCP lines, Tigris line, Joginder line and Chaudhary line of Birpur Cantt and Spl repair to Bldg No T-09 Bathroom for DSC personnel at HQ UKSA under GE Dehradun.
2023_MES_586297_1
8580/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dehradun
Class D cat a (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹88,000
Yes
13 Jun 2023
18 Mar 2023
17 Apr 2023
18 Mar 2023
15 Apr 2023
1 Apr 2023
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concretebut excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Material & labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortor 1:6 complete all as specified and as directed.
Material & labour for Brickwork (except bricks) with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortor 1:6 (bricks obtained under item No-1 of demolition will be re-used) complete all as specified and as directed.
Excavation in post holes (or similar holes ) in any type of soil each n exe 0.5 cum , gettting out, returning, filling in and ramming earth or broken rubble mixed with earth around , in layers not exeeding 25cm, watering, and removing surplus soil to a distance n exe 50 m and making good surface all as specified.
Taking down cement plaster of any description on brick/stone/concrete wall surfaces incl racking out joints hacking for key,scrubbing down with water etc and rubbish off the premises complete all as specified and as directed.
Material & labour for rendering 15 mm thick on brick work or concrete surfaces in cement mortar (1:4), finished surfaces even and fair without using extra cement complete all as specified and as directed.
Material & labour for rendering 15 mm thick on brick work or concrete surfaces in cement mortar (1:6), finished surfaces even and smooth without using extra cement complete all as specified and as directed .
Material & labour for rendering 10 mm thick in cement mortar 1:4 mixed with water proofing compound @ 3% by weight of cement in roof surface , complete all as specified and as directed.(Note- WPC shall be measured and paid separetely.)
Material & labour rendering 5 mm thick in cement mortar 1:3 on fair faces of concrete work finished even and smooth as in ceiling complete all as specified and ditected.
Material & labour for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of alkali resistant priming coat complete all as specified
Material & labour for Preparation of new plastered surfaces and applying 3 coats of white wash on walls complete all as specified and as directed.
Material & labour for complete removal of existing treatment from walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
Material & labour for complete removal of existing treatment from walls and applying 3 coats of white wash on walls complete all as specified and as directed.
Material & labour for two coat of white wash on new surfaces of ceiling etc including preparation of surfaces, complete all as specified & directed .
Material & labour for complete removal of existing treatment of walls including corners and applying two coats of distemper oil emulsion complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors, beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Dismantling asbestos cement (corugated or semicorrugated etc) sheets, in roof covering including ridge complete all as specified and directed.
Material & labour for Reinforced cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beam, etc. complete all as specifed and directed.
Material & labour for Reinforced cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specifed and directed.
Material & labour PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in sub bases, 25 mm thick finished even & rough to receive finishing layer, etc. complete all as specified.
Material & labour for cement concrete type C-2 1:3:6 (using 40mm graded aggregete as in foundation and mass concrete complete all as specified and directed.
Material & labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item No 22 here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as specified and as directed.
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, plinth beams and similar work; vertical or to batter complete all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough flat finished surfaces of concrete complete all as specified and directed.
Material & labour for ceramic glazed colured/ design tile in vertical surfaces (300x 450mm) x 7mm thick such as dado and skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 10 mm thick rendering in cement mortar 1:4 including dismantling of old tiles complete all as specified and directed.
Material & labour for non Skid ceramic tiles 7-8 mm thick(Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match of coloured tiles over and including 15 mm thick screed bed in cement mortar 1:6 including dismantling of old tiles complete all as specified and directed.
Material & labour Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in cement mortar of 1:6 complete all as specified and directed.
All as per item No 28 here-in- before but as in skirting/dado over and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
Material & labour 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone agg as in sub base complete all as specified and as directed by the Engr-in-Charge.
Taking down chowkhats or frames with shutters nexc. 1.5 Sqm each (without taking off shutter from frames) complete all as specified and directed.
Supply & fix PVC solid factory made door frame (chowkhat) of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, supplying & fixing in opening as per specification and drawing complete all as specified and directed.
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gab insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as shown in SSR Part-II and as directed by Engineer in Charge.
Supply & fix 150 mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed by Engr-in-Charge.
Supply & fix 150 mm long Aluminium anodised handles of fabricated type complete all as specified and as directed by Engr-in-Charge.
Supply & fix Butt hinges 100 mm size medium weight cold rolled stainless steel and fixed complete all as specified and as directed by Engr-in-Charge.
Material & labour for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10 cm width or girth complete all as specified and directed.
Supplying, fixing, jointing and testing galvanised steel water tubing 15 mm dia bore medium grade with all fittings such as bends, tees, nipples, elbows, socket reducers, etc, fixed to walls and ceilings or laid in floors complete all as specified and directed.
Supply & fix in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) water closet, including connection to trap and to flushing pipe, anti syphonage pipe etc, and making good to floor complete all as specified and as directed by Engr-in-Charge.
Supply & fix in repairs 10 litres capacity PVC low level valve less syphonic action type flushing cistern white with inlet, float valve, float and handle including brackets with 32 mm dia PVC pipe 600 mm long complete all as specified and as directed by Engr-in-Charge.
Supply & fix in repairs Vitreous China wash hand basin, white, of size 550mm x 400 mm fixed on and including cast iron cantilever bracket, 32 mm dia brass waste coupling and 32 mm dia PVC waste pipe, pillar tap including fixing of tap, waste fitting etc complete all as specified and directed.
Dismantling timber scantlings of framed work 40 Sq. cm and over in section, in any position complete all as specified and directed.
Supply & fix Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any guage, thickness including nainital or similar pattern roof coverings complete all as specified and directed.
Supply & fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Supply & fix Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply & fix Framed work such as grills, gratings, etc.. with ends of bars (angle,hollow section) shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Supply & fix Plates (plain or chequered) Fe 410-W(Gde-E- 250) quality-A channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment complete all as specified and directed.
Supply & fix Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W(Gde-E- 250) quality-A complete all as specified and directed.
Taking out & removing existing roof treatment of any description completely upto concrete surface including racking out joints, hacking for key,sweeping clean and scrubbing down with water etc to remove dust etc,complete all as specified..
Material & labour for applying cement slurry @ 3 Kg/Sqm on cleaned roof surface, complete all as specified.
Material & labour Water proofing roof treatment with Polymeric water proofing membranes of weight not less than 3Kg/sqm five layers with center core as 90 micron high molesuvre,high density polythene film sand witched between two layers of polymeric (Static polythene based) between laminated on both sides with 20 micron HMDPF film over a coat of hot blown bitumen with 85/25 grade @ 1.20 Kg/Sqm after priming the surface with bituminous emulsion @ 0.30 Litre/Sqm on plastered surface. Water proofing membrane should be laid with over laps 150 mm at ends and 75 mm for sides and shall be bounded uniformity by LPG torch flame over the polymeric water proofing membranes apply semi hot blown bitumen 85/25 grade @ 1.20 Kg/ sqm dusted sand over the coat of the coat @0.5 Kg/Sqm, complete all as specified and as per manufacturers instructions. NOTE:- The work of water proofing treatment shall be got executed throughh expert team of manufacturers or authorised applicator of manufacturer.
Taking down carefully existing aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc ( light, fan, socket, or power and switch, socket, regulator, holders, ceiling roses) complete and making good the disturbed surfaces of walls, Floors, ceilings etc to match with existing all as specified and directed.
Material & labour for point wiring complete with 3 runs (P + N+ Earth) of PVC insulated, unsheathed, FRLS, 1100 volt grade, size 1.5 sqmm, multi stranded, copper conductor single core in and including rigid PVC surface conduit not less than 19 mm dia, clip, complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including MS Box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and earth wire connected to earth dolly complete all as specified, required for One light/fan point controlled by one switch , complete all as specified and directed.
All as per item No 56 here-in-before but for one 5 pin 5 Amp socket outlet point on same board complete all as specified and directed.
All as per item No 56 here-in-before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed.
All as per item No 56 here-in-before but with 4 Sqmm copper conductor cables (multistranded) PVC insulated FRLS, for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed.
All as per item No 56 here-in-before but point wiring drawing through concealed PVC Conduit complete all as specified and directed.
All as per item No 56 here-in-before, but wiring drawing through concealed PVC Conduit for One three pin 5 Amp socket on same board with other switches complete all as specified and directed.
All as per item No 56 here-in-before, but wiring drawing through concealed PVC Conduit for One three pin 5 Amp socket on independent board complete all as specified and directed.
All as per item No 56 here-in-before, but wiring drawing through concealed PVC Conduit with 4 Sqmm. (nominal area) wire/cable for one 3 Pin 15 amp socket on independent board complete all as specified and directed.
Supply & fix switch piano flush, button type 5 Amp SP 250V AC complete all as specified and directed.
Supply & fix switch piano flush button type 15 Amps SP 250V AC complete all as specified and directed.
Supply & fix socket outlet 2-in-1, 5 Pin 5 Amps 250V AC complete all as specified and directed.
Supply & fix socket outlet 2-in1,3 pin 5 and 15 Amp flush type 250V AC complete all as specified and directed.
Supply & fix ceiling rose surface bakelite 3 terminals of size 65x25mm. complete all as specified and directed.
Taking down light fitting carefully without any damage from the exisitng position and re-fixing the same after the completion of civil work complete all as specified and directed
Supply & fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply & fix tube light fitting 1x20/22 watts and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed.
Supply & fix Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm with, blades, and frame and louvers complete all as specified and directed by Engineer-in-charge
Supply & fix Supply and fix Water heater storage type, electric, capacity 35 litres AC single phase 230/ 240 V o and connecting up including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed.
Supply & fix sheet metal enclosures TPN 415 Volt 4 way with suitable rated bus bar for Single door IP-43DB's complete all as specified and directed.
Supply & fix MCB SP 240 volt 10 KA 5 to 40 Amp, conforming to relevant IS complete all as specified & directed.
Supply & fix MCB SPN 240 Volt 10 KA 40 Amp conforming to IS complete all as specified.
Supply & fix MCB TPN 415 Volt 10 KA 63 Amp conforming to IS complete all as specified.
Supply & fix metal clad single pole and neutral enclosure with 2 pin and earth plug and socket complete with and including one single pole MCB 20 Amp 240Volt complete all as specified and directed.
Material & labour in replacement for submain wiring with 3 runs(N+P+E) of 1.5 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed/surface PVC conduit pipe of medium duty not less than 15 mm dia including necessary PVC conduit specials and connecting with suitable size thimble complete all as specified and directed. Note:-3 runs of 1.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 79 here-in-before but with 3 runs(N+P+E) of 2.5 Sqmm single core copper FRLS conductor . Note:-3 runs of 2.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 79 here-in-before but with 3 runs(N+P+E) of 4 Sqmm single core copper FRLS conductor .Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
Material & labour Earthing complete with GI earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to GI earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.
Supply and Laying in replacement XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V grade of size 10 sqmm 4 core after cutting to required length with necessary glands, nuts, bolts, and lugs complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable and getting out complete all as specified.
Material & labour for sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and directed by Engr-In-Charge.
Removing excavated material (soil) not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material & labour for brick well burnt Sub Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed.
Material & labour for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 50mm dia
M/s Teg Singh Negi
D.K. ENTERPRISES
kalakriti enterprises
MOHAN LAL GUPTA
M/s RP AGRAWAL
SRI GANESH ENTERPRISES
PRAGATI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .