GM,STPS
ADMIN BUILDING, STPS, PURULIA
Rate Contract for Tit-Bit wiring/Repairing/Replacement of damaged electrical items of materials at STPS for 02 (two) years.
2023_WBPDC_605795_1
WBPDCL/STPS/NIT/E3384/23-24
Open Tender
ELECTRICAL WORKS M/R
Item Rate
730 days
ADMIN BUILDING, STPS
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹36,636
Yes
ADMIN BUILDNG, STPS, PURULIA
9 Dec 2024
28 Nov 2023
26 Dec 2023
29 Nov 2023
22 Dec 2023
8 Dec 2023
6 Dec 2023
Amount
Tit-bit wiring/Repairing/Replacement of damaged electrical items of materials under EMIPH Dept
Fixing of One set of ICTPN SW 500V complete with fixing or Re-wireable type fuse & fuse base unit 15/16 A with the supply of material.MAKE:EE/GEC/HAVELLS/HPL/FLORA
Fixing of One set of ICTPN SW 500V complete with fixing or Re-wireable type fuse & fuse base unit 30/32 A with the supply of material.MAKE:EE/GEC/HAVELLS/HPL/FLORA
Fixing of One set of ICTPN SW 500V complete with fixing or Re-wireable type fuse & fuse base unit 60/60 A with the supply of material.MAKE:EE/GEC/HAVELLS/HPL/FLORA
Fixing of One set of ICTPN SW 500V complete with fixing or Re-wireable type fuse & fuse base unit 100 A with the supply of material.MAKE:EE/GEC/HAVELLS/HPL/FLORA
Fixing of One set of ICTPN SW 500V complete with fixing or Re-wireable type fuse & fuse base unit 200 A with the supply of material.MAKE:EE/GEC/HAVELLS/HPL/FLORA
Fixing of One set of ICTPN SW 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora 15/16amp
Fixing of One set of ICTPN SW 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora 30/32 amp
Fixing of One set of ICTPN SW 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora 60 amp
Fixing of One set of ICTPN SW 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora 100amp
Fixing of One set of ICTPN SW 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora 200 amp.
Fixing of one set of ICDB(SPN) SW 240 V Complete with Fuse & Fuse Base Unit &Natural Link with the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora 16 amp
Fixing of one set of ICDB(SPN) SW 240 V Complete with Fuse & Fuse Base Unit &Natural Link with the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora 32 amp
Fixing of one set of ICDB(SPN) SW 240 V Complete with Fuse & Fuse Base Unit &Natural Link without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora 16amp
Fixing of one set of ICDB(SPN) SW 240 V Complete with Fuse & Fuse Base Unit &Natural Link without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora 32 amp
Fixing of one set of 240V SPN-IC Distribution Board (ICDB) made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora 16Amps 2 way
Fixing of one set of 240V SPN-IC Distribution Board (ICDB) made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora 16Amps 3 way
Fixing of one set of 240V SPN-IC Distribution Board (ICDB) made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora 16Amps 4 way
Fixing of one set of 240V SPN-IC Distribution Board (ICDB) made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora 16Amps 6 way
Fixing of one set of 240V SPN-IC Distribution Board (ICDB) made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora 16Amps 8 way
Fixing of one set of 240V SPN-IC Distribution Board (ICDB) made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora 16Amps 10 way
Wiring with 1.1 kv grade single core Aluminum cable PVC Pipe (25 mm dia, 3mm thick) with the supply of materials Make : NETCC/ELECTRO CAB/ SUPER CAB / HAVELLS 3X1/2.80 (6 mm2 )with 16 Swg GI Wire for Earth Continuity .
Wiring with 1.1 kv grade single core Aluminum cable PVC Pipe (25 mm dia, 3mm thick) with the supply of materials Make : NETCC/ELECTRO CAB/ SUPER CAB / HAVELLS 3X1/2.24 (4 mm2 )with 16 Swg GI Wire for Earth Continuity .
Wiring with 1.1 kv grade single core Aluminum cable PVC Pipe (25 mm dia, 3mm thick) with the supply of materials Make : NETCC/ELECTRO CAB/ SUPER CAB / HAVELLS 3X1/1.8 (2.5 mm2 )with 16 Swg GI Wire for Earth Continuity .
Wiring with 2x1/1.8(2.5 mm2 ) Al Conductor with 19 mm Dia PVC Pipe including 1 No 16 Swg wire for Cable for Earthing Continuity with the supply of materials Make : NETCC/ELECTRO CAB/ SUPER CAB / HAVELLS
Wiring with 2x1/1.8(2.5 mm2 ) Al Conductor through suitable fire retardant ISI marked Casing ‘N’ Caping including 1 No 16 Swg wire for Cable for Earthing Continuity with the supply of materials Make : NETCC/ELECTRO CAB/ SUPER CAB / HAVELLS
Distribution Wiring with 2x1.4 (1.5mm2 ) Single core copper wire ,PVC Insulated & sheathed through 19 mm Dia. Polythene pipe to Light/Fan/ Calling Bell Points with 16 Swg GI wire for Earth Continuity .With supply of all Materials .
Distribution Wiring with 2x1.4 (1.5mm2 ) Single core copper wire ,PVC Insulated & sheathed through suitable fire retardant ISI marked Casing ‘N’ Caping to Light/Fan/ Calling Bell Points with 16 Swg GI wire for Earth Continuity .With supply of all Materials .
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 2 X 1/ 1.4 (1.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 2 X 1/1.8 ( 2.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 2 x 1 / 2.0 (4 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 3 X 1/ 1.4 (1.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 3 X 1/1.8 ( 2.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 4 X 1/ 1.4 (1.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 4 X 1/1.8 ( 2.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 5 X 1/ 1.4 (1.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 5 X 1/1.8 ( 2.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 6 X 1/ 1.4 (1.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 6 X 1/1.8 ( 2.5 mm2 )
Supply & Fixing of Double PVC Board ( 8”x12” )
Supply & Fixing of Double PVC Board ( 8”x10” )
Supply & Fixing of Double PVC Board ( 8”x6” )
Supply & Fixing of Double PVC Board ( 6”x4” )
Supply & Fixing of Double PVC Board ( 4”x4” )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Casing’ N’ caping (Fire retardant, ISI marks)& G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 2 X 1/ 1.4 (1.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Casing’ N’ caping (Fire retardant, ISI marks)& G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 2 X 1/1.8 ( 2.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Casing’ N’ caping (Fire retardant, ISI marks)& G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 2 x 1 / 2.0 (4 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Casing’ N’ caping (Fire retardant, ISI marks)& G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 3 X 1/ 1.4 (1.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Casing’ N’ caping (Fire retardant, ISI marks)& G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 3 X 1/1.8 ( 2.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Casing’ N’ caping (Fire retardant, ISI marks)& G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 4 X 1/ 1.4 (1.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Casing’ N’ caping (Fire retardant, ISI marks)& G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 4 X 1/1.8 ( 2.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Casing’ N’ caping (Fire retardant, ISI marks)& G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 5 X 1/ 1.4 (1.5 mm2 )
Laying of PVC insulated Copper Wire ( 5 X 1/1.8 ( 2.5 mm2 ) )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Casing’ N’ caping (Fire retardant, ISI marks)& G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 6 X 1/ 1.4 (1.5 mm2 )
Laying of PVC insulated Copper Wire 1.1 KV grade Single core With Casing’ N’ caping (Fire retardant, ISI marks)& G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK 6 X 1/1.8 ( 2.5 mm2 )
Supply & Fixing of Double PVC Board . ( 8”x12” )
Supply & Fixing of Double PVC Board . ( 8”x10” )
Supply & Fixing of Double PVC Board . ( 8”x6” )
Supply & Fixing of Double PVC Board . ( 6”x4” )
Supply & Fixing of Double PVC Board . ( 4”x4” )
Supply & Fixing of following Items 240 V 15/16 amps Piano type Switch Make –Anchor, Havells
Supply & Fixing of following Items 240 V 15/16 amps Piano type Socket Make –Anchor, Havells
Supply & Fixing of following Items 240 V 5/6 amps Piano type Switch Make –Anchor, Havells
Supply & Fixing of following Items 240 V 5/6 amps Piano type Socket Make –Anchor, Havells
Supply & Fixing of following Items 240 V Grade Bakelite Pendent Holder.Make –Anchor, Havells
Supply & Fixing of following Items 240 V Grade Angular Batten Holder.Make –Anchor, Havells
Supply & Fixing of following Items 240 V Grade Bakelite Ceiling Rose 2 Plate Type.Make –Anchor, Havells
Supply & Fixing of following Items 240 V Grade Bakelite Round Block.Make –Anchor, Havells
Supply & Fixing of following Items 240 V Grade Calling Bell /Buzzer.Make –Anchor, Havells
Supply & Fixing of following Items 240 V Grade PVC Round block of approved quality..Make –Anchor, Havells
Fixing of single/Twin Fluorescent Light fitting complete with all accessories. Wall/Ceiling/ Outside/Tubular Pole/ PCC Pole.
Fixing and fitting of HPSV lamp with all Accessories to be fixed/Projected from the wall of the building outside LT Tubular poles including making Holes/ providing Lamp arrangements with G.I pipe Hereing 1.5M. Average length and supply of PVC wire making connection as required and making good/repair or the damaged wall including painting with the supply of paints.( HPSV set and Lamp will be supplied W.B.P.D.C.L)
Supply and fitting & fixing of ANCHOR make holder on PVC board
Fixing of Fan Regulator on PVC board With supply of regulator of reputed company
Fixing of Fan Regulator on PVC board ( Without supply of regulator )
Supply & Fixing of 40mm(1.5”) Dia & 4 Mtr. Long(including Leads) Galvanized pipe vertical type service bracket on wall for carrying and an earth wire with 230 X 31 mm dia training screws, 75X88mm (3”X 3.5”) porcelain socket insulator with Galvanized straps, Bolts, Nuts, & Bush etc. ( including Painting materials) approved by the controlling officer.
Fitting of ceiling Fan(48”/52”)
Supply and Capacitor change (Unit rate)
Supply &Bearing Change( unit rate)
With material Rewinding including varnis
Capacitor changing (Unit rate)
Bearing Changing( unit rate)
Supply & Fixing of MCB Railing for ( Rating 10A, 15A, 20A, 32A) Without supply of MCB only
Supply & Fixing of MCB Railing for ( Rating 10A, 15A, 20A, 32A) With supply of MCB & MCB Cut Out. ( Make- HAVELLS)( Rating 10A, 15A, 20A, 32A)
Fixing & Fitting of Fuse cut-out With TOP & BASE) ( Porcelain or Bakelite type) of different rating. With supply of Fuse unit ( Unit Rate):- 15A, 20A, 32A
Fixing & Fitting of Fuse cut-out ( With TOP & BASE) ( Porcelain or Bakelite type) of different rating. Without supply of Fuse unit ( Unit Rate):- 15A, 20A, 32A
Tube light set ( 40Watt/20Watt) repairin charge, single set/double set Tube light with starter change(unit rate)
Tube light set ( 40Watt/20Watt) repairin charge, single set/double set CHOKE replacement ( Unit Rate)
Tube light set ( 40Watt/20Watt) repairin charge, single set/double set HOLDER replacement WITH SUPPLY ( Unit rate)
Tube light set ( 40Watt/20Watt) repairin charge, single set/double set HOLDER replacement WITHOUT SUPPLY ( Unit rate)
Preparationof Earthpit including supply of earth spike of length6' including soil digging & supply of necessary salt, required power etc.
Connection from earth spike to main switch inside the quarter with 8 SWG of G.I wire including supply
Earth wire laying along the wiring including supply of 0.75 Sqmm Copper wire
tit-bit wiring/Repairing/Replacement of damaged electrical items of under EMOPH Dept for both plant & township.
Fixing of one set of ICTPN SW 15/16A, 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit with the supply of all materials. Make EE/GEC/HAVELLS/HPL/Flora.
Fixing of one set of ICTPN SW 30/32A, 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit with the supply of all materials. Make EE/GEC/HAVELLS/HPL/Flora.
Fixing of one set of ICTPN SW 60/63A, 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit with the supply of all materials. Make EE/GEC/HAVELLS/HPL/Flora.
Fixing of one set of ICTPN SW 100A, 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit with the supply of all materials. Make EE/GEC/HAVELLS/HPL/Flora.
Fixing of one set of ICTPN SW 200A, 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit with the supply of all materials. Make EE/GEC/HAVELLS/HPL/Flora.
Fixing of one set of ICTPN SW 15/16A, 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora
Fixing of one set of ICTPN SW 30/32A, 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora
Fixing of one set of ICTPN SW 60/63A, 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora
Fixing of one set of ICTPN SW 100A, 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora
Fixing of one set of ICTPN SW 200A, 500 V Complete with fixing or Re-wire able type Fuse & Fuse Base Unit without the supply of all materials . Make EE/GEC/HAVELLS/HPL/Flora
Fixing of one set of ICDB(SPN) SW 16A, 240 V Complete with Fuse & Fuse Base Unit &Natural Link with the supply of all materials. Make EE/GEC/HAVELLS/HPL/Flora
Fixing of one set of ICDB(SPN) SW 32A, 240 V Complete with Fuse & Fuse Base Unit &Natural Link with the supply of all materials. Make EE/GEC/HAVELLS/HPL/Flora
Fixing of one set of ICDB(SPN) SW 16A, 240 V Complete with Fuse & Fuse Base Unit &Natural Link without the supply of all materials. Make EE/GEC/HAVELLS/HPL/Flora
Fixing of one set of ICDB(SPN) SW 32A, 240 V Complete with Fuse & Fuse Base Unit &Natural Link without the supply of all materials. Make EE/GEC/HAVELLS/HPL/Flora
Fixing one set of 240V 16A 2way SPN-ICDB made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora
Fixing one set of 240V 16A 3way SPN-ICDB made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora
Fixing one set of 240V 16A 4way SPN-ICDB made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora
Fixing one set of 240V 16A 6way SPN-ICDB made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora
Fixing one set of 240V 16A 8way SPN-ICDB made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora
Fixing one set of 240V 16A 10way SPNICDB made of steel sheet with Re-wire able type Fuse & Fuse Base with the supply of all materials . Make EE/GEC/HAVELLS/HPL/SIEMENS/Flora
Wiring with 1.1kv 1C 3X1/2.80 (6mm2) Al cable PVC Pipe (25 mm dia, 3mm thick) with 16 Swg GI Wire for Earth Continuity with the supply of materials. Make : NETCC/ELECTRO CAB/ SUPER CAB / HAVELLS
Wiring with 1.1kv 1C 3X1/2.24 (4mm2) Al cable PVC Pipe (25 mm dia, 3mm thick) with 16 Swg GI Wire for Earth Continuity with the supply of materials. Make : NETCC/ELECTRO CAB/ SUPER CAB / HAVELLS
Wiring with 1.1kv 1C 3X1/1.8 (2.5mm2) Al cable PVC Pipe (25 mm dia, 3mm thick) with 16 Swg GI Wire for Earth Continuity with the supply of materials. Make : NETCC/ELECTRO CAB/ SUPER CAB / HAVELLS
Wiring with 2x1/1.8(2.5 mm2 ) Al Conductor with 19 mm Dia PVC Pipe including 1 No 16 Swg wire for Cable for Earthing Continuity with the supply of materials Make : NETCC/ELECTRO CAB/ SUPER CAB / HAVELLS
Wiring with 2x1/1.8(2.5 mm2 ) Al Conductor through suitable fire retardant ISI marked Casing ‘N’ Caping including 1 No 16 Swg wire for Cable for Earthing Continuity with the supply of materials Make: NETCC/ELECTRO CAB/SUPER CAB/HAVELLS
Wiring with 2x1.4 (1.5mm2) 1C Cu wire, PVC Insulated & sheathed through 19 mm Dia. Polythene pipe to Light/Fan/ Calling Bell Points with 16 Swg GI wire for Earth Continuity .With supply of all Materials. Make: NETCC/ELECTRO CAB/SUPER CAB/HAVELLS
Wiring with 2x1.4 (1.5mm2) 1C Cu wire, PVC Insulated & sheathed through suitable fire retardant ISI marked Casing ‘N’ Caping to Light/Fan/ Calling Bell Points with 16 Swg GI wire for Earth Continuity. With supply of all Materials. Make: NETCC/ELECTRO CAB/SUPER CAB/HAVELLS
Laying 1C 2x1/1.4(1.5mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 2x1/1.8(2.5mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 2x1/2.0(4.0mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK )
Laying 1C 3x1/1.4(1.5mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 3x1/1.8(2.5mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 4x1/1.4(1.5mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 4x1/1.8(2.5mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 5x1/1.4(1.5mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 5x1/1.8(2.5mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 6x1/1.4(1.5mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 6x1/1.8(2.5mm2) Cu Wire, 1.1kV PVC insulated With Polythene Pipe & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Supply & Fixing of 8”x12” Double PVC Board. Make: Anchor/Havells/Goldmedal/Preeti Plast.
Supply & Fixing of 8”x10” Double PVC Board. Make: Anchor/Havells/Goldmedal/Preeti Plast.
Supply & Fixing of 8”x6” Double PVC Board. Make: Anchor/Havells/Goldmedal/Preeti Plast.
Supply & Fixing of 6”x4” Double PVC Board. Make: Anchor/Havells/Goldmedal/Preeti Plast.
Supply & Fixing of 4”x4” Double PVC Board. Make: Anchor/Havells/Goldmedal/Preeti Plast.
Laying 1C 2x1/1.4(1.5mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 2x1/1.8(2.5mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 2x1/2.0(4.0mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 3x1/1.4(1.5mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 3x1/1.8(2.5mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 4x1/1.4(1.5mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 4x1/1.8(2.5mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 5x1/1.4(1.5mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 5x1/1.8(2.5mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 6x1/1.4(1.5mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Laying 1C 6x1/1.8(2.5mm2) Cu wire 1.1 KV PVC insulated With Casing’ N’ caping (Fire retardant, ISI marks) & G.I Earth wire of the following sizes. Make- Havells/Mescab/Finolex/KDK
Supply & Fixing of 8”x12” Double PVC Board. Make: Anchor/Havells/Goldmedal/Preeti Plast.
Supply & Fixing of 8”x10” Double PVC Board. Make: Anchor/Havells/Goldmedal/Preeti Plast.
Supply & Fixing of 8”x6” Double PVC Board. Make: Anchor/Havells/Goldmedal/Preeti Plast.
Supply & Fixing of 6”x4” Double PVC Board. Make: Anchor/Havells/Goldmedal/Preeti Plast.
Supply & Fixing of 4"x4” Double PVC Board. Make: Anchor/Havells/Goldmedal/Preeti Plast.
Supply & fixing 15/16A piano type switch 240V. Make: Anchor/Havells
Supply & fixing 15/16A piano type socket 240V. Make: Anchor/Havells
Supply & fixing 5/6A piano type switch 240V. Make: Anchor/Havells
Supply & fixing 5/6A piano type socket 240V. Make: Anchor/Havells
Supply & Fixing Bakelite Pendent Holder 240V. Make: Anchor/Havells
Supply & Fixing Angular Batten Holder 240V. Make: Anchor/Havells
Supply & Fixing Bakelite Ceiling Rose 2 Plate Type, 240V. Make: Anchor/Havells
Supply & Fixing Bakelite Round Block 240V. Make: Anchor/Havells
Supply & Fixing Calling Bell /Buzzer 240V. Make: Anchor/Havells
Supply & Fixing PVC Round block of approved quality, 240V. Make: Anchor/Havells
Fixing of single/Twin FTL/LED fittings complete with all accessories on Wall/Ceiling/ Outside/Tubular Pole/PCC Pole
Fixing and fitting of HPSV/LED lamp with all Accessories to be fixed / Projected from the wall of the building outside LT Tubular poles including making Holes/ providing Lamp arrangements with G.I pipe Hereing 1.5M. Average length and supply of PVC wire making connection as required and making good/repair or the damaged wall including painting with the supply of paints. (HPSV set and Lamp will be supplied by WBPDCL
Fixing of HPSV/LED fitting on pole/Tower or similar structure with suitable clamp without supply of materials
Supply & fixing of holder on PVC board ( Make: Anchor )
Supply & fixing fan regulator of reputed make
Fixing of fan regulator of reputed make
Supply & Fixing of 40mm(1.5”) Dia & 4M Long (including Leads) GI pipe vertical type service bracket on wall for carrying and an earth wire with 230 X 31 mm dia training screws, 75X88mm (3”X 3.5”) porcelain socket insulator with GI straps, Bolts, Nuts, Bush etc. (including Painting materials)
Fitting of ceiling Fan(48”/52”)
Supply & replacement of fan capacitor (Aluminium housing). Make: HAVELLS/TIBCON/UNIVERSAL
Supply & replacement of fan bearing. ( MAKE: NTN/NBC/TATA or any reputed make. )
Rewinding of fan with varnishing
Replacement of fan capacitor Without supply
Replacement of fan bearing Without supply
Fixing of MCB Railing without supply of MCB (10A - 32A)
Supply & Fixing of MCB Railing With MCB & MCB Cut Out. (Make- HAVELLS) (Rating 10A - 32A)
Fixing & Fitting of Fuse cut-out With ( TOP & BASE) (Porcelain or Bakelite type) with supply of Fuse unit- 15A - 32A
Fixing & Fitting of Fuse cut-out With ( TOP & BASE) (Porcelain or Bakelite type) without supply of Fuse unit- 15A - 32A
Preparation of Earthpit including supply of earth spike of length 6' including soil digging & supply of necessary salt, required power etc.
Connection from earth spike to main switch inside the quarter with 8 SWG of G.I wire including supply
Earth wire laying along the wiring including supply of 0.75Sqmm Copper wire.
M/S M.M.C. ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .