Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC AT PO RAJRAPPA PROJECT RAMGARH JHARKHAND 829150 | RAMGARH | RAMGARH | JHARKHAND | 829150 | L1 | Accepted-AOC AWARDED | |
| 2 | L2₹5.7 L+₹24,411 (4.49%)Rejected-AOC AT PO RAJRAPPA PROJECT DIST RAMGARH JHARKHAND 829150 | RAMGARH | RAMGARH | JHARKHAND | 829150 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹5.8 L+₹37,321 (6.86%)Rejected-AOC MAIN ROAD CHITARPUR DISTT RAMGARH JHARKHAND | CHITARPUR | RAMGARH | JHARKHAND | 829150 | L3 | Rejected-AOC REJECTED |
Tender Value
₹6.0 L
EMD Value
₹7,500
Closing Date
19 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM
SO EnM OFFICE RAJRAPPA
Diversion of HT Overhead Line of 6.6KV of feeder No.- 7 (Route length for erection approx. 250mtr. Approx. and route length for dismantling of OH line 380m approx.) at Sec.-II New patch at Mines of Rajrappa Project
2024_CCL_318977_1
SO(EnM)/Rjp/24-25/Et/66dt 09.10.24
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
RAJRAPPA
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,500
17 Apr 2025
9 Oct 2024
21 Oct 2024
10 Oct 2024
19 Oct 2024
10 Oct 2024
10 Oct 2024 - 14 Oct 2024
Amount
Erection of metallic pole of length Above 11.00 metre and upto 13.00 metre, in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Labour cost for loading, unloading of metallic poles, conductors etc. for transportation from store to site (vice- versa). (Truck will be provided departmentally).
Supplying and erection of galvanised stay set for 11KV overheadlines complete with 19/20mm dia X1.8 metres long stay rod, anchor plate of size 45cmX45cmX7.5mm thick, thimble, stay clamps, turn buckle (20 mmX600mm), 7/4.00mm dia G.I. stay wire and 11KV strain insulator etc. in cement concrete 1:3:6 (1cement: 3coarses and :6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Erection of angle iron/ channel iron cross arm on steel tubular/ rail pole etc. as required. [For conductor bracket= 1x2=2 & Cradle guard bracket= 3]
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Erection/ Tensioning of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required. (Route length for erection approx. 250m).
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required. [For earth wire. (Approx. route length=250 mtr)].
Supply of 8 SWG GI wire for Cradling.
Erection of Cradle Guard 3 Wire. (2 nos. of spans).
Finishing with Epoxy paint (Aluminium Colour) (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat (red oxide zinc chromate), preparation of surface, etc. complete, on 9 nos. of Poles.
(a) Nomenclature of poles ( Feeder No., Voltage, Number of poles etc.) and (b) colour coding of poles of feeder with radium sticker of colours as required.
Supply and erection of approved make safe earthing electrode consisting pipe-inpipe technology as per IS 3043-1987 made of corrosion free G.I. pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing in earth pit of minimum bore dia. 150mm size With 3 metre G.I. pipes having outer pipe dia of 50mm having 80-200 micron galvanizing, Inner pipe dia. of 25mm having 200-250 Micron galvanizing, connection terminal dia. of 12mm in nominal soil with 50 kg (two bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level.
providing masonry enclosure with cover plate having locking arrangement and as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Making deep bore hole 150mm dia, 9 ft. deep for each earthpit
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Total impact of GST for the purpose of CTC
Coalfield Construction
KHANAN BHARTI CONSTRUCTION
techsummary_330625.pdf
PDF • 0.19 MB
finsummary_330625.pdf
PDF • 0.19 MB
OVER.pdf
PDF • 1.00 MB
finance_330625.pdf
PDF • 0.20 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .