Providing, Supplying, Installation, Testing And Commissioning of Submerged Centrifugal Pumping Machinery with Co-Ordinate Mechanical And Electrical Accessories in Ghoghariyo Kuwo at Talaja, Dist.: Bhavnagar Under 15 Percentage Vivekadhin Grant Year-2026-27
354223
63/2026
Open
Pumps/Motors
Works
Bhavnagar
3 documents required · 3 mandatory
₹900
The Chief Officer, Talaja Nagarpalika, Talaja
₹8,000
9 Oct 2026
9 Oct 2026
9 Oct 2026
23 Oct 2026
9 Oct 2026
NAME OF WORK : PROVIDING, SUPPLYING, INSTALLATION, TESTING & COMMISSIONING OF SUBMERGED
CENTRIFUGAL PUMPING MACHINERY WITH CO-ORDINATE MECHANICAL & ELECTRICAL ACCESSORIES
LOCATION :- GHOGHARIYO KUWO, AT. Talaja
PERCENTAGE RATE TENDER
Item No. & Description Quantity Rate Per Amount
Providing & Supply at Site, Storage of submerged centrifugal pump sets
(horizontal/vertical as required) (water immersed, dry air filled, class "F"
insulated TEWC motor integrally mounted on volute casing pump sets for
water duty, 3-phase, 50Hz ± 3%, 415V ± 10% along with suitable
foundation / installation device with cable length from pumps to panels &
of following Material of Construction: Impeller-CF8M, Casing-C.I. FG
Wearing Ring -SS, TC mechanical seal, CS/S.S. bearing, S.S shaft with
sleeve, SS strainer & MS motor body as per relevant IS and detailed
specification including installation of pumping mechinery Capacity 35 LPS
x 50.00 Mtr. Head with minimun prime mover 1450 RPM of 30 KW x
set (1W) = 30 KW Upto 30.00 KW
Installation, testing & commissioning for submerged centrifugal pump sets
(without material supply) For upto 30.00 KW 1.00 20948.00 Job
Supply at Site, Storage, Erection, Installation, Testing & Commissioning of
M.S. 150mm Ø Delivery pipe line with Flanges, Concentric Nozzles Bolts,
Nuts and Pipe with Y-Tee Connection Flanges, Eccentric / concrentic
Nozzles etc. Complete as per relevent IS Standard 300.00 109.36 Kg
Supply at Site, Storage, Erection, Installation, Testing & Commissioning of
M.S. 350mm Ø Common Header pipe line with Y-Tee Connection,
Flanges, Bolts, Nuts Piping etc. Complete as per relevent IS Standard &
requirement. 500.00 109.36 Kg
Supply at Site, Storage, Erection, Installation, Testing & commissioning of
M.S 100mm Ø By pass Pipings with Y-Tee Connection, Flanges, Bolts,
Nuts etc. Complete as per relevent IS Standard & requirement 150.00 109.36 Kg
Supply at site, storage, Erection, installation, testing & commissioning of
150mm Ø Both End Flanged Butterfly Valve as per IS 13095 with
sleeve of EPDM & disc, shaft & internal parts of SS-410, with ISI mark of
PN 1.6 Rating to be installed on Delivery Pipe complete as per
specifications & requirement. 1.00 4853.00 No.
Supply at Site, Storage, Erection, Installation, Testing & Commissioning of
350mm Ø with Both End Flanged Butterfly Valve For Header PN
Rating and ISI mark of IS 13095 with sleeve of EPDM & disc, shaft &
internal parts od SS - 410 & with ISI Mark only as per technical
specification & requirement. 1.00 31331.00 No.
Supply at site, Storage, Erection, Installation, Testing & Commissioning of
Both End Flanged 100mm Ø C.I. Non Rising Spindle Type Sluice Valve
of PN 1.6 with hand / wheel cap opereted (pd type short body) Rating
etc. Complete (For Air valve on Header Pipings & Bypass piping) as
per relavant Std.& Specification With ISI Mark Only 1.00 4037.00 No.
Supply at site, Storage, Erection, Installation, Testing & commissioning of
DS 2 Type 100 mm Ø Double Acting Air Valve on Header Pipings as
per relavant Std. with Approved make etc. Complete as per Specification.
Supply at site, storage, Erection, installation, testing & commissioning of
150 mm Ø C.I. D/F reflux valve on Delivery pipe confirming to relevent
standard with PN 1.6 rating etc. Complete as per specifications. 1.00 8933.00 No.
Supply at site, Storage, Erection, Installation, Testing & commissioning of
350 mm Ø C.I. D/F reflux valve for Header pipe confirming to relavent
standard with PN 1.6 Rating of Approved make etc. Complete as per
Techanical Specification & requirement. 1.00 65376.00 No.
Supply at Site, Storage, Erection, Installation, Testing & Commissioning of
flange ends Expansion Bellow as per EJMA standards of overall length
of minimum 300 mm, designed for 15 mm axial compression and 5 mm
axial extension with tie rods etc. of following MOC & pressure ratings.
MOC: Bellows: SA 240 Gr. 304; Internal Sleeve: SA 240 Gr. 304;
Weldends: IS 2062 Gr. B; Flanges: IS 2062 Gr. B (Drilling as per IS
/IS 6392 ) & Limit Rods & Nuts: CS - IS 1367 for Common Delivery
Piping 150 mm Ø PN 1.6 (Width : 300mm) 1.00 4896.00 No
Supply at Site, Storage, Erection, Installation, Testing & Commissioning of
flange ends Expansion Bellow as per EJMA standards of overall length
of minimum 300 mm, designed for 15 mm axial compression and 5 mm
axial extension with tie rods etc. of following MOC & pressure ratings.
MOC: Bellows: SA 240 Gr. 304; Internal Sleeve: SA 240 Gr. 304;
Weldends: IS 2062 Gr. B; Flanges: IS 2062 Gr. B (Drilling as per IS
/IS 6392 ) & Limit Rods & Nuts: CS - IS 1367 for Header Piping 350 mm
Ø PN 1.6 (Width : 300mm)
Design, Supply, Installation, Testing, Commissioning of Bourdon Type
Pressure Gauge, ±1% accuracy, Direct bottom 1/2" NPT (M) process
connection, IP 67, Glycerine filled, SS304 Case with Bayonet Type Bezel,
SS316 L Bourdon Tube, SS 316 Movement material, Aluminium dial with
black graduation on white background, Micro Zero adjustable pointer,
neoprene gasket, Blow out disc, shatter proof glass, SS tag plate etc as
per IS 3624. 100MM Dia (i) 0 to 10 kg/cm² (on Delivery Pipe) 1.00 1029.00 No.
Providing & Laying Reinforced Cement Concrete in Thrust Block /
Piping / Valves Supports etc. with TMT steel, Black Trap Kapchi as
Coarse Aggreate for Raft, Grillage Footing with Necessary Centering
Form work, Consolidating as per Directive in 1:2:4 Ratio comp. as per site
requriement 2.00 8566.40 M3
Manufacture, Supply at Site, Storage, Erection, Installation of M.S.
specials flanged ends with labour charges for lowering laying, erecting,
fixing, various size of M.S. section such as joints channel, angles, plates,
specials etc. complete with fabrication For Tee, Bend, Reducer, Flange
S.I.T.C. of LV MCC Panel totally enclosed, dust & bermin proof, indoor
type, minimum degree of protection - IP 52 as per IS: 2147, operation on 3-
Phase, 4 Wire, 415V, 50Hz, Neutral effectively grounded, with
instrumentation compartments accomodating LED type indicating lamps,
control contactors as per IS: 13947, CT of accuracy class- I as per IS:
2705, relays, meters & control MCBs, air insulated electrolitic grade
Aluminum busbar for three phase & neutral system with incomming
breaker- microprocessor based Air Circuit Breakers (electrically operated
drawout type)/ air break fixed type MCCB with trip free mechanism,
current limiting type as per IS: 8828, Motor Contractor (as per type -2
coordination), Overload Relay with built-in single phasing prevention
feature & auxiliary feeders as per SLD drawings, momentary contact type
push buttons, equipment fittings, bus bars, cable boxes, cable gland,
incoming & ougoing cable connection for 1100V grade, Aluminium/
Copper conductor XLPE/ PVC insulated & PVC sheathed armoured cable,
10% spare terminals,
Power wiring using 1100V grade, FRLS insulated copper conductor wires
conforming to IS: 694 & 8130, cable compartments/ alleys of minimum
300mm size, GI earth bus bar for entire length. MCC shall be fabricated
from cold rolled, coled annealed (CRCA) sheet steel & minimum thickness
of various members shall be as follows: Base Frame/ Channel/ Gland
Plate - 3 mm, Load Bearing Members/ Doors - 2 mm and Internal
Partitions - 1.6 mm. Auto Transformer Starter with MCCB, Contactor,
O/L relay, cast resin type CT, Digital MFM, Analogue Ammeter, SPP,
Timer etc. 30 KW = (1 working feeder) [Size 700mm(w) x 450mm(d) x
Supply, laying, testing & commissioning of 1.1 kV grade, XLPE insulated,
stranded Copper conductor, galvanised steel flat strip / round wire
armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid
on wall surface with necessary clamps / in existing cable trench / cable
trays / conduit / pipe sleeves at road crossing or floor as per site
requirement) conforming to IS:7098 (Part-1) & IEC:60502 (Part-1) etc.
comp. with required accessories.
Size 1x3 Corex25 Sq.mm. (From Main Supply) 50.00 534.00 Mtr
Size 1x3 Corex16 Sq.mm. (Panel Board to Motar) 80.00 324.00 Mtr
Supply, Installation, Fabrication, Testing and commissioning of GI
perforated type cable trays with returned edge / flange, fabricated from
mm thk sheet steel in the standard length of 2.5 mtrs, duly hot dipped
galvanized after fabrication as per IS 2629-1989 / IS 4759-1984 including
accessories such as coupler plates/ fish plates, bends, tees, reducers,
elbows, covers and electro-galvanized hardware etc, erected on existing
support as per specification and instruction of engineer in charge
Size : 300mm(W) x 50mm(H) x 2mm thick 25.00 541.00 Mtr
Supplying & erecting earth pit of minimum bore dia.150mm size approved
make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS
3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe
dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm
having 200-250 Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive compound with
high charge dissipation suitable for following type of applications with
chamber and heavy duty cover. (A)(approved make OEM has to submit
test certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) & having back
filling compound of (B) Inner chemical (CCM Compound)- Resistivity:-
ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time Necessary
test report must be submitted by Agency. [A] For electrical installation
up to 440 V Length of Pipe - 1.00 Mtr Back filling compound - 1 Nos.
of Bag of 15 Kgs. 1.00 4546.00 Each
Total Amounts Rs..……
Total Amounts Rs..……
I/We am/are willing to carry out the work @ ______% Above / Below___________Percentage (should be writen in
figures and words) of the Estimated rates mentioned above amount of my / our Tender works out as under.
Estimated Amount Estimated Amount
Put to Tender Rs. 7,98,223=00 Put to Tender Rs. 7,98,223=00
Total Rs. Total Rs.
(In Words (In Words
Stamp with Signature of Contractor
Consl.Engineer Engineer
"DESIGN POINT" Talaja Nagarpalika
Chief Officer President
Talaja Nagarpalika Talaja Nagarpalika
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01 PM Work Vol I.doc
DOC
02 Form B-1.pdf
03 PM Work Vol II.pdf
03 Schedule B.pdf
04 Terms and Conditions.pdf
05_PM Mechenical Speci. PART-1.pdf
06_PM Mechenical Speci. PART-2.pdf
07 Vendor list - Mechanical as on Dt. 05.09.2026.pdf
08 Test Require For Construction Material.pdf
10 GR All_compressed.pdf
09.1 DMO_2941_01-Apr-2026_744.pdf
10 GR Affidavit GR_240217_161336.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .