Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC work allotted |
| 2 | L2₹1.5 Cr+₹92,175 (0.60%)Rejected-Finance | ₹1.5 Cr+₹92,175 (0.60%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.7 Cr+₹15.3 L (10.0%)Rejected-Finance B 1703 MODERN INDUSTRIAL ESTATE BAHADURGARH HARYANA 124507 | BAHADURGARH | JHAJJAR | HARYANA | 124507 | ₹1.7 Cr+₹15.3 L (10.0%) | L3 | Rejected-Finance L3 |
| 4 | L4₹1.9 Cr+₹34.0 L (22.3%)Rejected-Finance | ₹1.9 Cr+₹34.0 L (22.3%) | L4 | Rejected-Finance L4 |
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
25 Jun 2021, 2:00 pmClosed
Executive Engineer
Executive Engineer, Elect. Division PWD BandR Br., Karnal (0184-2265696)
Construction of 10 Mtr. Shooting Range at MNSS Rai Distt. Sonipat (Pdg. HVAC work).
2021_HRY_174457_1
HVAC Shooting range MNSS Rai
Open Tender
Electrical Works
Works
150 days
Sonipat
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹2.9 L
30 Nov 2021
5 Jun 2021
25 Jun 2021
5 Jun 2021
25 Jun 2021
5 Jun 2021
Amount
Water circulating pumps: Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled ( Long coupled Type ) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications. Casing (Volute) - Cast Iron.Impeller - Gunmetal Bronze - Statically and Dynamically Balanced Casing Gasket - Confined Non Asbestos Fiber Pump Shaft - SS 316/416. Flush Line - Braided Stainless Steel Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical seal without disturbing the pump shaft alignment) Motor Type - TEFC Squirrel Cage, Efficiency Class - IE2, Insulation - Class F, 415V ± 10% , 50Hz ± 5%, 3Ø AC Power Supply Impeller - Gunmetal Bronze - Statically and Dynamically Balanced Lot- RCC Foundation with Anivibration pads. Water flow rate:320 USGPM (1280 lpm), Head : 25 mtrs (2w + 1s)
Air Handling Unit (Floor Mounted) - Exposed Type FLOOR MOUNTED AIR HANDLING UNITS Supply, Installation, Testing & Commissioning of factory fabricated Outdoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with Thermal break profile at corners and at joints for double skin air handling units along with internal covings with mixing chamber with 0.63mm thick pre-plasticide galvanised sheet outside & 0.63mm thick polished Stainless Steel sheet inside with Backward curved direct driven plug type in supply & exhaust side with fan section with fan motor with IE2 rating & suitable for 415+10%, 3 Phase, 50 Hz , 6 RD cooling coil with coil section , prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% before cooling coil The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor & belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU shall be insulated with 48+2 mm thick injected fire retardent PUF of density 40+2 Kg/m³ . The motor & fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling , filters should not exceed 500 FPM. AHU Kit to be included for installation The capacities of airhandling shall be as follows AHU capacity 16000 CFM / 65 mm St. pressure (40 TR capacity) with 6 row deep Copper cooling coils. AHRI / Eurovent certified.
SUB HEAD 'B'- PLUMBING Piping rates are deemed to include any special tappings or sockets required by other agencies or for commissioning, filling, testing the system. Such items will be measured along centreline, with the pipe. Chilled water line Supplying, laying/ fixing, testing & commissioning of following nominal sizes of chilled water plumbing M.S Heavy "C" Class ERW conforming to IS:1239 / 3589 complete with fittings like elbows,tees, reducers, bends, MS flanges, supports, welding, painting etc.but excluding valves,strainers,guages etc inside / outside the building along the wall / ceiling & duly insulated with Nitril Rubber with Factory laminated with Chemically treated 7MIL Glass cloth for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. & complete as per specifications. Thickness of insulating material confirmed as per technical specification. 125 mm dia.( 25 mm thick insulation)
100 mm dia.( 25 mm thick insulation)
80 mm dia.( 25 mm thick insulation)
65 mm dia (25 mm thick insulation)
Supply,installation,testing and commissioning of following PN-10 valves, stainers gauges in the chilled/hot water piping duly insulated to the same specifications as the connecting piping with compainion flanges and adequately supported as per specification and drawings . The chilled water circuit with all fittings and insulation shall be as per the drawings and specifications. Supply, installation, testing and commissioning of Butterfly valves complete with companion flanges, nuts, bolts, gaskets etc. as specified. Butterfly valves with cast iron body, seat of black nitrile rubber (tight shut-off), nylon coated S.G. iron disc, PTFE coated SS (AISI 410) shaft, complete with companion flanges, nuts, bolts, gaskets etc. as required. These valves shall conform to BS: 5155, MSS SP 67 & API 609 and shall be designed to fit without gaskets between mating flanges. The valves shall be suitable for flow in either direction and seal in both directions. The valves shall be of integral moulded design., position confirming to standard specification 100 mm dia
80 mm dia.
65 mm dia.
Supply, installation, testing & commissioning of Dual plate type check valves (NRV) complete with companion flanges, nuts, bolts, gaskets etc.as specified in position conforming to standard specification. 100 mm dia
Supply,installation,testing and commissining of MS( Hot deep galvanised ) fabricated "Y" type strainers with removable type SS 304 screen with 3mm perforation & permanent magent etc.complete with companion flanges, nuts, bolts, gaskets etc. as specified in technical specification as per SSPL 107 series. 100 mm dia.
Supply, installation, testing & commissioning of ductile iron fabricated out Moving cup technology cartridge(stainless steel) Type Automatic Balancing valves PN16 rating, end connection compatible with DIN En 1092-1 2002 with "O" ring EPDM complete with companion flanges, nuts,bolts,gaskets etc. as specified. in position conforming to standard specification. 100 mm dia
Supply, installation, testing and commissioning of Stainless steel SS 304 pressure guage with appropriate range with SS syphon & Ball valve duly insulated with nitrile rubber with thickness 9 mm of approved make of dia 150 mm conforming to techinical specifications.
Supply, installation, testing and commissioning of Mercury filled 'V' form thermometer with thermo well of approved make conforming to technical specifications.
Supply, installation, testing and commissioning of auto air vent valve with cock or ball valve of following sizes:- 25mm
Closed Expansion Tank alongwith Air separator with Pressurisation Pump Kit for Chilled Water Line Supply, installation, testing and commissioning of 300 Ltr Closed type EXPANSION TANK along with necessary accessories such as air vents,Safety Valves, with required Support etc. The tank shall be made out of MS-2062 with replaceable heavy duty butyl rubber bladder.
SUB HEAD 'C'- DUCTING, GRILLES & INSULATION WORKS Spiral Ducting ( Factory fabrication ) SITC of Factory fabricated 120 GSM GSS ducting complete with hanging arrangements of fastners, GI threaded rods of sizes: 24 Gauge - Rectangular
22 Gauge - Rectangular
24 Gauge - Oval
22 Gauge - Oval
Duct inside Accoustic Lining Supply,installation,testing and commissioning of fire retardant Open cell Nitrile rubber accoustic insulation 15 mm thick thickness of thermal conductivity as per specification (Joint shall be sealed with self adhesive tape.)
SITC of nitrile rubber 19/30 mm pasted on the outer/inner surface of duct with suitable adhesive complete in all respect with nitrile tape. 19 mm thick (outer insulation)
13 mm thick (inner insulation)
UV coating of external duct with 3 coats of Starbond 30 - 36 chemical with 7 mil glass cloth.
Supply / Return air Grill Supply, installation, testing & commissioning of Powder coated Aluminium extruded grilles for supply air normal flow, 0° / 15° deflection one way as per specification & the sizes will be as per tender drawing mention:
Supply, installation, testing and commissioning of Aluminium extruded volume control dampers with key operated of anodised black painted matt finished in supply / return( if required) air collars.
SUB HEAD 'D'- ELECTRICAL WORKS Main HVAC Panel Design, Fabrication, Assemble, Wiring , Supply, Errection, Testing, Commissioning of cubical type main MV panel board suitable for 3 phase, 415 volts, 50 Hz and of 35 KA rupturing capacity at 415 volts, fabricated from minimum 1.6/2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through process complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. (Location : Suit at Site condition) Incoming 630 AMP MCCB TP + NL 50 KA incoming Thermal magnetic with O/L, S/C with ROM, 1 No. Digital Multifunction meter and CTs of rating 600/5A. 3 Nos.phase indicating lamps. Main Al. bus bar rated at 800 amps TPN, 50 KA with heat shrinkable sleeve and shall be of aluminium. Outgoning 03 Nos. 200 A TP MCCB For air cooled chiller Units, overload relay start/stop push buttons, ammeter (0-150A) with single CT & ON / OFF / TRIP indication lights etc. 03 Nos. TPN MPCB with DOL Starter suitable for chilled water Pump's Motor. The MCB compartment shall contain CT operated Multifunction meter stating Voltage/Ampere/Frequency including indication lights etc as required. Outgoing feeder for AHU's localised starter panels :06 No.40-63 amps MCCB TPN with required Links/ROM etc as outgoing feeder for AHU's starter panel at 3rd and second level, The compartment shall contain an indicating lamp with MCB for ‘ON’ status. Necessary cable alleys, space for 2 Nos. spare switches, wiring and G.I. earthing of all equipment shall also be provided. Potential free contact shall be provided with necessary modbus protocol compatible to BMS and energy management system.
POWER & CONTROL CABLING HSR 31.26 Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections. 240 Sq. mm 3.5 Core Cable . (31.26 (xxxiii) Ard.) RMT
185 Sq. mm 3.5 Core Cable . (31.26 (xxxii) Ard.) RMT
120 Sq. mm 3.5 Core Cable . (31.26 (xxx) Ard.) RMT
Supply and laying of CONTROL CABLE 1.1 kV grade armoured XLPE insulated and sheathed copper conductor cables of sizes below, on existing cable trays including terminations with suitable clamps, saddles, hooks, bolts etc. complete as per specifications and as required. RMT 4C X 1.5 Sq.mm
Earthing Strip / Wires. HSR 31.22 Providing and fixing 25 mm X 3 mm G.I. strip on surface or in recess for connections etc. as required. RMT
HSR 31.22 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required RMT
HSR 31.81 Supply & erection of cable tray made out of 2 mm thick galavanised perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material required to complete the Job in all respect upto the Entire statisfaction of Engineer-in-Charge of the work. 100 mm x 50 mm x 1.6 mm RMT
150 mm x 50 mm x 1.6 mmn RMT
300 mm x 50 mm x 1.6 mm RMT
Supply Installation Testing and Commissioning of exhaust fan 18 inches
Minor civil work - openings for supply and return ducts and making good of them, arrangement for hanging ducts at double height, base work for installation of chiller, AHUs, etc.
Pioneer Aicon
Hemcool Engineers
modern cooling solution
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .