| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹11.2 L+₹16,521.75 (1.50%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹11.3 L+₹32,685 (2.97%)Rejected-AOC | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹11.6 L+₹62,151.50 (5.65%)Rejected-AOC 308 RAMNAGAR ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 5 | L5₹12.3 L+₹1.3 L (12.1%)Rejected-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹18.3 L
EMD Value
₹36,500
Closing Date
29 Jun 2024, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/ REPLACEMENT OF WALL PLASTER, CHHAJJA, ROOF TREATMENT, PERIODICAL SERVICES AND OTHER B/R WORKS OF TECHNICAL AND RESIDENTIAL AREA OF DEAL UNDER GE (I) RND DEHRADUN
2024_MES_657221_1
GE(I)RND/9357/E8/24-25
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Class E Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹36,500
Yes
31 Aug 2024
1 Jun 2024
1 Jul 2024
1 Jun 2024
29 Jun 2024
15 Jun 2024
1 Jun 2024 - 15 Jun 2024
Amount
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000 M complete all as specified and directed
M&L for Brick work with sub class B bricks, straight or curved on plan exceeding 6m mean radious built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Demolition of plain cement concrete ( Un reinforced)of any description in any position not otherwise specifically provied and removal and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
M&L75mm thick PCC 1:3:6, type C2, using 40mm graded stone aggregates as in Plinth protection, platform and floor surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in sub base of floors complete all as specified and directed.
M&L Plain cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate as in foundation filling & Mass concrete , sub base.complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in lintels upto 1.5 clear span , cills steps seismic and other similar bands, copings, hold fast and the like incluing weathering , slightly rounded or chamfered angles and throating asdirected with and icluding necessary form work in CM 1:4 complete all as specified and directed.
Demolition of ( reinforced cement concrete) (reinforcement cut as required to facilitiate demolition) of any description and in any positionnot otherwise specifically provided for and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
M&L for RCC(1:2:4) type B-1using 20 mm graded stone aggregate as in slab supported on walls, beams, and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M& L for Mild steel TMT bars 8 mm dia and over cut to length, bent to shape required, including cranking, bending spi-rally for hooping for col-umns, hooking ends and binding with and in-cluding mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys , scrubing down with water etc, complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as "supply only" under respective item of sch A/ BOQ.
M & L for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth (without using extra cement) complete all as specified and directed.
M & L for 10 mm thick rendering on fair faces of brick work or concrete surfaces of ceiling in cement mortar 1:3 finished even and smooth (without using extra cement) complete all as specified and directed.
Material and labour for 50mm thk (average) PCC 1:2:4 type B-1 using 20mm graded stone agg as in roof padding finished even and smooth without using extra cement all as specified and directed .
M&L for Screed bed 15mm thick in CM 1:4 finished even and smooth without using extra cement on roof mixed with water proofing compound as per manufacture instruction (WPC shall be measure and paid separaterly) etc complete all as specified & directed.
Supply only Liquid water proofing compound ISI Marked (used 200 ml per bag of cement) complete all as specified and directed.
M&L for A coat of cold applied bituminous primer over cleaned surface @ 0.30 Kg/Sqm and applying one coat of hot blown bitumen 85/25 grade @ 1.20 Kg/Sqm followed by APP modified five layer polymeric membrane 3mm thick, minimum weight 3.60 kg/sqm reinforced with polyester non-woven fabric (weighing not less than 150 gms/sqm) manufactured by authorised manufacturer specified in particular spicification, laid as per the manufacturer instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces and applying one coat of hot blown bitumen 85/25 grade @ 1.20 Kg/Sqm finally finished with bituminous aluminum paint @ 0.20 Kg/Sqm complete including taking down existing roof treatment from RCC slab, cleaning off all foreign material by wire brushing, cleaning off surface and removal of spoil to a distance .exc 500m complete all as specified & directed. Note:- The work shall be executed through authorised applicator approved by GE.
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
M&L for bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
M & L for preparation of newly plastered surface and applying of Birla/JK white wall putty approx 1 mm thick in two layer as per manufacturer's instruction on newly prepared surface and make the surface smooth by rubbing with sand papers etcand applying two coat of oil emulsion distemper over a coat of primer complete all as specified and directed. complete all as specified and directed.
Prepration of new plaster surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
M & L Preparation of old surfaces of ceiling, plastered on un plastered by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss & efflorescent salts, removing all vegetation growth and trading oil and greasy spots and applying one coat of white wash on old white washed surfaces ofceiling complete all as specified and directed.
M&L for preparing old surfaces of walls plastered or un-plastered by brooming down with steel or wire brush and scraping down smoke soot, moulds moss & efflorescent salt and trading oil and greasy spots , washing rubbing down and stopping of distempered and painted surface & removing all vegetation growth, nails and making good holes,cracks etc complete by necessary putty and make the surface smooth by rubbing with sand papers etc and applying one coat of distemper oil emulsion on old prepared surfaces of walls complete all as specified and directed.
M&L for Preparation of new plaster surfaces of wall and applying two coats of cement base paint etc complete all as specifed and directed.
M&L for preparation of old painted surface wall / ceiling by brooming down loose partical, removing of smoke soot, moulds and unwanted vegetation from wall, facia, parapet etc applying one coat of cement base paint complete all as specified and directed.
M&L for complete removel of existing plastered or unplastered surfaces on walls and applying of Birla/JK white wall putty approx 1 mm thick as per manufacturer's instruction on newly prepared surface and make the surface smooth by rubbing with sand papers etc and applying Two coat of weather proof exterior paint silicon based over a coat of primer complete all as specified and directed.
M & L for preparation of old iron or steel surfaces of any description, over 10cm in width or girth,not applying one coats of synthetic enamel paint complete otherwise described complete all as specified and directed.
M&L for Preparation of old wooden surfaces over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L Providing and injecting chemical emulsion for post construction anti termite treatment along external wall below concrete or masonry apron using chemical emulsion @ 2.25 liters per liner meter including drilling and plugging holes etc in apron complete all as specified and directed
M&L for injecting at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
S & F in repair PVC (SWR) pipes 75 mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S & F in repair PVC (SWR) pipes 110 mm bore, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius, with access door, for 75 mm bore of pipe complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius, with access door, for 110 mm bore of pipe complete all as specified and directed.
S & F in repair PVC (SWR) junction, with access door, single (single T) equal or unequal, for 75 mm bore of pipe complete all as specified and directed.
S & F in repair PVC (SWR) junction, with access door, single (single T) equal or unequal, for 110 mm bore of pipe complete all as specified and directed.
S & F PVC (SWR) reducers 110 mm bore complete all as specified and directed.
S & F PVC (SWR) vent cowl bore of 110 mm bore complete all as specified and directed.
S & F PVC (SWR) bends any radius of bore 75 mm bore complete all as specified and directed.
S & F PVC (SWR) bends any radius of bore 110 mm bore complete all as specified and directed.
Taking out steel water tubing and connections including cleaning for refixing 15 mm dia complete all as specified and directed.
Taking out steel water tubing and connections including cleaning for refixing 20 mm dia complete all as specified and directed.
Taking out steel water tubing and connections including cleaning for refixing 25 mm dia complete all as specified and directed.
M&L for 15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete all as specified and directed.
M&L for 20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete all as specified and directed.
M&L for 25mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete all as specified and directed.
Re-fixing old steel water tubing and connections in new or old position (walls, ceiling, floors etc) 15 mm dia including taking up or down existing steel tubing pipe complete all as specified and directed. (Note: Serviceable pipes & fiitings obtained from item 44 to be re-used)
Re-fixing old steel water tubing and connections in new or old position (walls, ceiling, floors etc) 20 mm dia including taking up or down existing steel tubing pipe complete all as specified and directed. (Note: Serviceable pipes & fiitings obtained from item 45 to be re-used)
Re-fixing old steel water tubing and connections in new or old position (walls, ceiling, floors etc) 25 mm dia including taking up or down existing steel tubing pipe complete all as specified and directed. (Note: Serviceable pipes & fiitings obtained from item 46 to be re-used)
M&L for Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills sunshades, shelves lintels etc and cutting chases for concealed water pipes etc and making good cutting not exc 10cm.complete all as specified and directed.
S&F in repair bib taps brass fancy type, brass,chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair pillar taps, brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F in repair bib cock long body with flange , fancy type, brass,chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or GI socket complete all as specified and directed.
Providing and fixing sheet glass corner shelf assembly consisting of 5.5mm thick sheet glass shelf with chromium plated bracket guard and railing as per sample approval complete all as specified and directed.
M&L for cutting down removing vegitation plant digging out penetrated roots with tronices looping branches not exc. 10cm girth PROTRUDING over wall roofs by necessary cutting hole in brick / concrete wall/ surfaces and injecting chemical GLYPHOSPHATW 41% SL 20 ml or till refusal by makimg cut/ injection in the stem of plant 30mm C/C spraying with solution (25ml Glyphospoto 41% diluted with one litre water) and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 and to match the existing work and finishes and removing of debris out side premises/ defence land including necessary scaffolding etc wk will be carried out upto 8th storey height bldgs complete all as specified & directed.
M&L for cutting down removing vegitation plant digging out penetrated roots with tronices looping branches not exc. 10cm girth PROTRUDING over wall roofs by necessary cutting hole in brick / concrete wall/ surfaces and injecting chemical GLYPHOSPHATW 41% SL 20 ml or till refusal by makimg cut/ injection in the stem of plant 30mm C/C spraying with solution (25ml Glyphospoto 41% diluted with one litre water) and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 and to match the existing work and finishes and removing of debris out side premises/ defence land including necessary scaffolding etc wk will be carried out upto 4th storey height bldgs complete all as specified & directed.
Disconnecting & taking down existing water tank of capacity exc 250 liter and not exc. 500 liter and removing from site complte and S&F rotational moulded polyethylene water storage tanks 500 lts capacity (cylindrical vertical with closed top) hoisted with and including 25mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed.
Disconnecting & taking down existing water tank of capacity exc 250 liter and not exc.100 liter and removing from site complte and S&F rotational moulded polyethylene water storage tanks 1000 lts capacity (cylindrical vertical with closed top) hoisted with and including 25 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed.
S&F in repair 25 mm bore dia of pipe gun metal globe of gate valves with iron wheel head screwed both endds for iron pipe and dixed complete all as specified and directed.
S&F in repair 20 mm bore dia of pipe gun metal globe of gate valves with iron wheel head screwed both endds for iron pipe and dixed complete all as specified and directed.
M/S P K ARORA
KISHORE ENTERPRISES
ANEJA AND COMPANY
M/S WASEEM KHAN CONTRACTOR
Aron Water Proofing and Pest Control
OM TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .