Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹16.8 L+₹46,682.50 (2.86%)Rejected-Finance AIR FORCE ROAD NEAR BRIDEES CORP KHELTIWADI RATIY N 9306 JAMNAGAR GUJARAT 361 006 | JAMNAGAR | JAMNAGAR | GUJARAT | 361006 | L2 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 3 | L3₹17.4 L+₹1.0 L (6.41%)Rejected-Finance | L3 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 4 | L4₹21.8 L+₹5.4 L (33.2%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Rejected for acceptance being not lowest. |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
6 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jamnagar No.2
GE (AF) Jamnagar No 2, Air Force-II, Udhyog Nagar, Jamnagar-361004
REPAIR / REPLACEMENT OF SEWAGE WORKS AND CONNECTED ITEMS IN OMQ, MAP AND BILLETS AREA AT AF-I UNDER GE (AF) JAMNAGAR NO 2
2020_MES_351476_1
8253/E8
Open Tender
Miscellaneous Works
Works
180 days
JAMNAGAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jamnagar No.2
₹50,000
Yes
3 Oct 2020
10 Jun 2020
7 Jul 2020
11 Jun 2020
6 Jul 2020
22 Jun 2020
60 days
Amount
Demolition and breaking up 150 mm dia bore RCC / salt glazed stone ware drain/sewage line pipe including PCC packing under haunching against the sides of pipe bed and complete PCC of bed and removal of debris to outside MOD land complete all as specified and directed.
Demolition and breaking up 200 mm dia bore RCC / salt glazed stone ware drain/sewage line pipe including PCC packing under haunching against the sides of pipe bed and complete PCC of bed and removal of debris to outside MOD land complete all specified and directed.
M&L for 150 mm bore reinforced concrete hume pipes, class NP2, laid and jointed with collars complete all as specified and directed.
M&L for 200 mm bore reinforced concrete hume pipes, class NP2, laid and jointed with collars complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in bedding including haunching & packing under and against the side of pipe 150 mm bore, after they are laid and tested complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in bedding including haunching & packing under and against the side of pipe 200 mm bore, after they are laid and tested complete all as specified and directed.
Excavation in trenches n.exc 1.50 meter wide & n.exc 1.50 meter depth for foundations etc shafts, well cesspits, manholes, pier holes etc n.exc 10.00 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as specified and directed.
Removing excavated soil to a distance exc 1.5 Km but n.exe 5 Km and depositing at a level not exceeding 1.50m above the starting point all as directed at site.
Demolition of cement concrete in ground floor and pavings not exe 15 cm thickness below or above ground level, including removal of debris to outside MOD land complete all as specified and directed.
Demolition of RCC slabs/manhole covers set in cement mortar (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for manholes/soakage well and similar works supported on walls set in cement mortar 1:6 complete. Note:- Reinforcement steel will be measured & paid separately.
M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required including bending, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
Demolition of brick/stone /PCC blocks masonry work built in cement mortar or cement lime mortar complete & removal of debris to outside MOD land complete all as specified and as directed.
M&L for providing precast cement concrete (1:5:8) (using 20mm graded stone aggregate ) solid building blocks exc 10 cm in width (with plain or inter locking joints as directed) setting in CM 1:6 complete in wall, pillars and similar works complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:4 over brick /PCC block masonry wall surface, finished the surfaces even and smooth without using extra cement all as specified and directed.
Cutting into existing manholes in running sewage line for connecting new drains of 150 / 200 mm internal dia of pipe, making good to walling and rendering, cutting out branch channel, and as required complete all as specified.
M&L for cement concrete 1:3:6 type C1, using 20 mm graded stone aggregate as in surface channels and drains, including finish the surface even and smooth with using extra cement complete all as specified.
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate ) as in coping, benching and like including weathering, slightly round or chamfered angles and throating as directed and including necessary use and waste of formwork all as specified & as directed.
M&L for 75 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring/hard standing and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in plinth protection/hard standing, including finishing the surface even and fair complete all as specified and directed.
M&L for cement concrete 1:4:8, type D-2,(using 40 mm graded stone aggregate) as in foundation to path / flooring complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block of approved shape and size of 60 mm thickness, with minimum compressive strength of 35 N / Sqmm (M-35 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, with top layer of white cement and pigment laid over and including 20 mm thick (compacted thickness) sand screed bed complete all as specified and directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for and removal of debri to outside MOD land complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:3 on sunken portion of toilet on vertical / horizontal surface and mixing only liquid water proofing compound as per manufacturers instructions, finished the surface even & smooth without using extra cement including applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre complete all as specified and directed. Note:- Supply only WPC will be measured & paid separately
M &L for plain cement concrete type E-2 (1:5:10), using 40 mm graded stone aggregate, for filling sunken portion of toilet and similar work complete all as specified and directed.
Supply and fix in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580 mm x 440 mm white with integral foot rests with ‘P’ or ‘S’ trap of Cast iron 100 mm , front or back inlet including all connection and provision of lime concrete base complete all as specified and as directed..
S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, plastic water closet seat cover with hinges, white, closed pattern with flat bottom, and cover with aluminised hinging device, 'P' or 'S' trap of 100 mm bore including all connection complete all as specified and directed.
S&F in repair cast iron floor trap, outlet dia 100 mm, including jointing to waste pipe fixed in cement concrete 1:2:4, Type B 1 using 20 mm graded stone aggregate complete.
S&F in repair cast iron nahani trap, outlet dia 100 mm, including jointing to waste pipe fixed in cement concrete 1:2:4, Type B 1 using 20 mm graded stone aggregate complete.
S&F in repair salt-glazed stoneware gully traps, square or round mouthed, type of size 150 x 150 mm fixed in cement concrete 1:2:4, Type B 1 using 20 mm graded stone aggregate complete all as specified and directed.
Dismantling cast iron work of any description with all fittings and fixtures complete all as specified and directed.
S&F 75 mm dia cast iron sand cast pipe, for soil, waste and vent in any length with or without ears, laid in trenches or in floors, with cement joints, complete all as specified and directed .
S&F 75 mm dia cast iron sand cast pipe, for soil, waste and vent in any length with or without ears, fixed on wall with MS clamp, with cement joints, complete.
S&F 100 mm dia cast iron sand cast pipe, for soil, waste and vent in any length with or without ears, laid in trenches or in floors, with cement joints, complete.
S&F 100 mm dia cast iron sand cast pipe, for soil, waste and vent in any length with or without ears, fixed on wall with MS clamp, with cement joints, complete.
S&F 75 mm dia bore cast iron oval access door bend (any radius) diminishing pieces or tapers (Larger bore measured) complete.
S&F 100 mm dia bore cast iron oval access door bend (any radius) diminishing pieces or tapers (Larger bore measured) complete.
S&F 75 mm dia bore cast iron branch piece single, equal or unequal, ordinary or inverted (Spigot or socketed type) or parallel branches with oval access door complete.
S&F 100 mm dia bore cast iron branch piece single, equal or unequal, ordinary or inverted (Spigot or socketed type) or parallel branches with oval access door complete.
Taking down rainwater/drain pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F PVC (SWR) pipes 75 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement , fixed to walls with suitable clamps complete all as specified and as directed.
S&F PVC (SWR) pipes 75 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement , laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement , fixed to walls with suitable clamps complete all as specified and as directed.
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement , laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) bends 110 mm dia complete all as specified and directed.
S&F PVC (SWR) bends 75 mm dia complete all as specified and directed.
S&F PVC (SWR) vent cowl 110 mm dia complete all as specified and directed.
S&F PVC (SWR) vent cowl 75 mm dia complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in bedding including haunching & packing under and against the side of pipe 100 mm bore, after they are laid and tested complete.
Cleaning of running sewage lines 100 mm dia from manhole to manhole by manual / mechanical rodding, removing all sludge / waste and making the line functional including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning of running sewage lines 150 mm dia from manhole to manhole by manual / mechanical rodding, removing all sludge / waste and making the line functional including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning of running sewage lines exc 150 but n exc 300 mm dia from manhole to manhole by manual / mechanical rodding, removing all sludge / waste and making the line functional including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning & desludging manholes depth not exc 1.0 m, of any size & shape by removing all sludge / waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning & desludging manholes depth exc 1.0 m but not exc 2.0 m, of any size & shape by removing all sludge / waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning of gully traps by removing all sludge / waste etc including cleaning of connected pipe up to 1st Man Hole to remove blockage, and finally washing with clean water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning of floor traps/nahani traps by removing all sludge / waste etc including cleaning of connected pipe up to gully trap to remove blockage, and finally washing with clean water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Removal of blockage from Indian WC/ EWC by removing all sludge / waste etc including cleaning of connected pipe up to first manhole to remove blockage, and finally washing with clean water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
S&F in repairs stainless steel grating of size 150 mm x 150 mm fixed with cement screed complete all as specified and directed.
M&L for cutting holes into or through stone/PCC block wall built cm. and making good in cm 1;3 or PCC type B-1 on required. Superficial area n exc 150 sq.cm all as specified .
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar and rubbish off the premises including removal of debris to a distance outside MOD land complete all as specified and directed.
M & L for 25 mm thick cement concrete type B0 1:2:4 (using 12.5 mm graded aggregate) as in levelling course in flooring complete all as specified and directed.
M&L non - skid joint free (edge cut) coloured ceramic tiles not less than 7 mm thick, area of each tile exc 0.06 sqm but n exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L non - skid joint free (edge cut) coloured ceramic tiles not less than 7 mm thick, area of each tile exc 0.11 sqm but n exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for joint free (edge cut) glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
S& F in repairs 10 Litre capacity PVC syphonic action type flushing cistern low level with inlet ball valve, float, handle & flush pipe, PVC connection etc fixed in position and connecting complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed.
S & F factory made solid panel PVC door shutter 30 mm thick (stiles) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent coment for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, including alumminium anodised butt hinges 100mm long, handle 150mm long, tower bolt 100 mm as per specification and drawing complete all as specified and directed.
S&F in repair 450 mm long PVC connections 15 mm size with PTMT nuts at both ends complete all as specified and directed.
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, including removal of debries to a distance outside MOD land complete all specified and directed.
M&L for rendering 15 mm thick in CM 1:6 on brick or stone walls to be finished even and smooth (without using extra cement) incl mixing liquid water proofing compound complete all as specified and directed. Note :- Supply only WPC will be measured & paid separately.
M & L for cement plaster 5 mm thick in CM 1:3 on concrete surface as on ceilling finished even and smooth with out using extra cement complete all as specified and directed.
M&L for preparation of new external surfaces of walls including brooming down and two coats of cement base paint over a coat of primer complete all as specified and directed.
M & L for preparation of new surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed.
SohanandCompany
aarti construction
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .