Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC 204B SENTHAMANGALAM GOTHANDARAMPURAM VILLAGE PERUMANADU POST VAYALOGAM VIA PUDUKKOTTAI DIST TN | PUDUKKOTTAI | TAMIL NADU | 622104 | L1 | Accepted-AOC Being Lowest and reasonable | |
| 2 | L2₹8.4 L+₹19,163 (2.33%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹8.7 L+₹44,424 (5.41%)Rejected-Finance 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L3 | Rejected-Finance Not being lowest |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
4 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE WELLINGTON
Headquarters, Commander Works Engineers, Wellington, Barraks-Post, The Nilgiris, PIN 643231
PROVISION OF SITE REQUIREMENTS FOR INSTALLATION OF NCN AND NFS EQUIPMENT AT NAI (TRICHY) UNDER AGE (I) TIRUCHIRAPPALLAI.
2020_MES_349964_1
84504/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
TRICHY
E Class b i Category
6 documents required · 6 mandatory
₹500
AGE (I) TRICHY
₹17,000
Yes
20 Jul 2020
4 Jun 2020
6 Jul 2020
4 Jun 2020
4 Jul 2020
20 Jun 2020
5 Jun 2020 - 12 Jun 2020
60 days
Amount
Taking down chowkats or frames not exceeding 1.5 Sqm each with shutters (without taking off shutters from the frames) and removing to store complete all as specified and directed.
M&L for brick work in cement mortar 1:6 with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius complete all as specified and directed.
M&L for rendering in cement mortar 1:4, 15mm thick on fair faces of brick work on concrete surfaces finished smooth without using extra cement complete all as specified and directed.
M&L for Rendering in cement mortar 1:6, 10mm thick on fair faces of brick work on concrete surfaces finished smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of Antifungal exterior emulsion paint over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for circuit /sub main wiring using 2 runs of 4 sqmm and 1 run of 4 sqmm for earth continuity with FRLS, ISI Marked, PVC insulated, multi standard copper conductor, single core cables drawn through and including non metallic PVC conduit, medium grade with all fittings and accessories in surface/ recessed complete all as specified and directed. (Note: Two runs of PVC insulated cable with one run of earth wire and one run of conduit including accessories shall be measured as one length)
Supply, laying and testing XLPE Power/Control Copper Cables, Solid Copper conductor of 25 sqmm, single core, balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Unarmoured/, extruded PVC Type ST2 Outer Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 complete all as specified and directed.
Supply, laying and testing XLPE Power/Control Copper Cables, Solid Copper conductor of 10 sqmm, 4 core, balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Unarmoured /, extruded PVC Type ST2 Outer Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 complete all as specified and directed.
Supply and fixing single pole and neutral enclosure 20 Amps with two pin and earth plug socket complete with one single pole MCB AC 240 volt 50 Hz complete all as specified and directed.
Supply and fixing double pole DC distribution board, 12 way with positive bus bar 100 A suitable for DC 200 volts supply complete all as specified and directed.
Supply and fixing MCCB TPN 4 pole 200 A, 415 volts 25 KA adjustable thermal and fixed magnetic setting complete all as specified and directed (incomer).
M&L for earthing complete with GI earth plate electrode 60x60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron steel strip 32x6mm by means of bolts, nuts check nuts and washers made out of GI or steel connected to earthing test point, panel board and continuous earth strip protected by using galvanized iron pipe, light grade 40 mm bore and 20mm dia bore GI pipe, medium grade for watering funnel all as shown in Electrical plate No 3 of SSR part I with and including necessary earth work and excavations in any type of soil, PCC 1:2:4, type B1, chamber 40mm thick, RCC 1:2:4, type B1, for cover slab with 8mm dia, TMT bars at 100mm centre to centre on both ways and MS hook with 6mm dia round bars etc., including taking out unserveasable old earthing complete all as specified and directed.
Supply and fixing DC MCB SP suitable for protection against overload & short circuit for control DC supply 220 volts 6-63 Amps rating complete all as specified.
Supply and fixing DC MCB DP suitable for protection against overload & short circuit for control DC supply 220 volts 63 Amps rating complete all as specified.
Supply and fixing of MS hot dip powder coated perforated type cable tray 300 mm width and 50 mm height including all accessories such as (equal tee tray, jointing tray U, bracket, stand plate, angle connector, bracket mounting, wall bracket, hold down clip, hanger beam, hanger clevis, hold down clamp joggled plate, raceway end plate, adjustable splice plate, horizontal hinge fish plate, vertical hinge fish plate, Horizontal branch, S plate, vertical branch, S. plate etc) complete all as specified and directed.
Supply and laying in trenches/ through pipes/ ducts or on poles/ walls jointing to LT panels, main switch with cable size aluminium lugs and testing XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volt grade, 50 sqmm 3.5 Core all as specified and directed by Engineer-in-Charge
Excavation in trenches in hard/Dense soil not exceeding 1.5mtr wide and not exceeding 1.5mtr deep and getting out for pole, stay, laying of UG cable, water tubing etc. complete all as specified and directed
Removing surplus excavated materials (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Returning and filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed
Supplying, spreading and compacting approved sand in trenches for cable cushioning at bottom and top of cable complete all as specified and directed. Note : Punned thickness shall be measured and paid.
M& L for burnt bricks sub class 'B', lay dry, in trenches as in underground cable protection complete all as specified and directed
Supply and labour for chemical earthing with copper electrode 80 mm dia, 2 mtr height buried directly in ground 2.25 m below the ground level) with top edge of the plate not less than 0.3 m below normal ground level, connected to copper strip 50x6 mm copper internal strip by means of bolts, nuts check nuts and washers made out of copper connected to earthing test point, panel board and continuous earth strip protected by using galvanized iron pipe, light grade 40 mm bore including back fill chemical compound, necessary earth work and excavations in any type of soil, Cast iron cover for chamber complete all as specified and directed
S&F earth continuity conductor copper strip of size 32 x 6mm complete all as specified and directed.
S&F earth continuity conductor GI strip of size 25 x 4 mm complete all as specified and directed.
M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. in and including medium grade, non metallic PVC conduit and accessories on wall/roof/floor etc, ISI marked suitable for surface conduit wiring with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly complete all as specified and directed by Engr-in-charge
Supply and Fix switch piano type single pole one way 5 Amp 240V, 50Hz AC, ISI marked complete all as specified and directed.
Supply and fix ceiling rose, poly carbonate isolated body with two to three terminals complete all as specified and directed.
Supply and fixing exhaust fan 300 mm sweep, industrial type, heavy duty, 1440 rpm, 240 volts & 50Hz including shutter louver, 1 sqmm copper twin core cable from ceiling rose including cutting hole on wall, grouting nut bolts and washers, making good to disturbed surfaces complete all as specified and directed.
Supply and installation commissioning of Hi-Wall Split AC 1 Ton capacity, single phase, 50Hz, minimum 5 star rating and EER 3.2, with inbuilt air ioniser and plasma filter for better indoor air quality including inbuilt dual inverter type, cordless remote control unit, all necessary copper tubes for connection of equipments and provision brackets for outer unit installation on wall complete all as specified and directed. Note:- Fixing shall be got installed and commissioned by the authorized rep of the manufacturer.
Supply and fix voltage stabilizers for automatic operation suitable for 1 TR split AC single phase, naturally air cooled indoor type & designed for input variation between 140 V to 280 V with output voltage stabilized at 230 V with accuracy of +- 2.5 % .complete all as specified and directed.
al mecho fab
rc enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .