Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32,395Accepted-AOC | ₹32,395 Quoted ₹32,394.78 | L1 | Accepted-AOC lowest |
Tender Value
Refer Docs
Closing Date
18 May 2026, 3:00 pmClosed
Assistant Executive Engineer
PWD Electrical Subdivision, Kottayam
GENERAL AC Repiring Urgent maintenance of AC units in the chamber of the District Collector Kottayam Electrical AC Work
2026_PWD_847347_2
ESDK_ET_176_2025-2026
Open Tender
Electrical Works
30 days
Kottayam
Please refer Tender documents.
10 documents required · 10 mandatory
₹335
6 Jul 2026
8 May 2026
20 May 2026
8 May 2026
18 May 2026
8 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1AC works | |||||
| 1.001 | OD282793/2025-2026:Charges for Servicing the following Air Conditioner Units such as cleaning using chemical materials and water. Cleaning air filter, attending petty repairs to copper tubes leak testing, rectifying defects if any and making the unit in proper working condition.-for 1/ 1.5 /2 TR Split (High Wall) type Units and 5.5TR floor mounted AC units | - | each | 2,415 | - |
| 1.002 | OD282796/2025-2026:Charges for filling sufficient quantity of R32 gas for existing air conditioner unit including leak testing, rectifying the defects leak arresting etc as required- | - | kg | 982.05 | - |
| 1.003 | OD282813/2025-2026:Supply and renewing PCB unit for Split AC unit-1/1.5/2TR in place of the existing faulty ones and giving connections etc as required- | - | each | 3,421.77 | - |
| 1.004 | OD282819/2025-2026:Supply and renewing Running Capacitor for AC unit - 1/1.5/2/ TR in place of the existing faulty ones and giving connections etc as required- | - | each | 378.61 | - |
| 1.005 | OD282830/2025-2026:Supply and renewing 22 A 2 Pole , AC 3 Power Contactors( L&T make MNX 22-2p/equivalent) for 1ph AC Units in place of the existing faulty ones and giving connections etc as required- | - | each | 1,127.82 | - |
| 1.006 | OD282835/2025-2026:Supply and installation of one number three phase 40A contactor with one NO contact suitable for AC outdoor unit | - | each | 3,194.13 | - |
| 1.007 | OD282836/2025-2026:Supplying and installation of LT make single phase preventer for tower air conditioner | - | each | 2,148.78 | - |
| 1.008 | OD282837/2025-2026:Supply and renewing Outdoor Fan Motor for Floor mounted 5.5TR AC unit in place of the existing faulty ones and giving connections etc as required- | - | each | 9,957.54 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1435699.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewnitR.pdf
Tender Documents • 0.02 MB
sbd.pdf
Tender Documents • 1.64 MB
Specificcondition.pdf
Additional Documents • 0.03 MB
LISTOFMATERIALS.pdf
Additional Documents • 0.13 MB
BOQ_1435699.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid