Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹31.7 L+₹2.8 L (9.83%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹37.0 L+₹8.1 L (28.2%)Rejected-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-AOC REJECTED | |
| 4 | Rejected-Technical | - | Rejected-Technical REF TECHNICAL EVALUATION DOCUMENT | |
| 5 | Rejected-Technical C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | - | Rejected-Technical REF TECHNICAL EVALUATION DOCUMENT |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
11 Aug 2021, 6:00 pmClosed
GE I CG PORBANDAR
MILTARY ENGINEERING SERVICES, DHQ-01 GE I CG PORBANDAR OPP BIRLA FACTORY PORBANDAR
REPAIR, MAINTENANCE /REPLACEMENT OF INTERNAL AND EXTERNAL ELECTRIC SUPPLY, WATER SUPPLY , DG SET , AC AND OTHER MISC ITEMS AT ICGS VADINAR UNDER GE I CG PORBANDAR
2021_MES_460626_1
8634
Open Tender
Civil Works
Item Rate
180 days
ICGS VADINAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹58,000
Yes
27 Sept 2021
17 Jul 2021
12 Aug 2021
17 Jul 2021
11 Aug 2021
30 Jul 2021
Amount
SCHEDULE 'A'
EXTERNAL ELECTRIC SUPPLY (LT DISTRIBUTIONSYSTEM) Servicing of DG set ('C' Check) of Cap 100 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lub oil filter. (b) Lubrication oil. (c) Fuel filter. (d) Coolent top up. Make of DG set: Ashok Leyland Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately
Supply only parts/ Items of DG set 100 KVA (Make : Ashok Leyland) Oil Filter
Fuel Filter
Air Filter Secondary
Air Filter Primary
Coolant
Engine Oil
Battery Terminals
Comprehensive maintenance and repair of APFC panel by replacement of worn out spare parts and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.99 by adjusting/ calibrating the APFC relay of any type, complete all as specified and directed by Engr-in-Charge. Note: Defective parts if any will be measured and paid seaprately
Supply only items for APFC Panel Heavy duty gas filled Capacitor per KVAR,415V, 3phase, 50 Hz. Make: L&T/C&S/Siemens
8 Steps APFC Relay Make: L&T/C&S/Siemens
Servicing of Servo Stabilizer oil cooled automatic type of capacity 30 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel level, supply system, Lubrication system, cooling system, rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lubrication oil. (b) 3 Phase Digital display system Make of Stabilizer : Vinitec
Supply and fix in replacement Digital time switches for LT panel 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified Make :L&T/Hensel
M&L preparing old rusted surface of steel tubular pole by means of sand paper/scrubing of dust etc and apply one coat of red oxide on surface of Steel poles and applying two coats of silver paint on Pole and numbering of poles with synthetic enamel paint white in 100 mm high letters over 150x150 mm black base complete all as spd and as directed by Engineer-in-Charge.
Supply and fix in replacement thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection complete all as specified and directed Make : Hensel Cat No.DK 2525 G or its equivalent in Legrand/sintex
M&L for bore Earthing 150 mm bore for earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres length,top edge of GI pipe 15 cm above GL , connected with earthing lead of 25X4 mm GI strip to the earthing test point and filling of charcol dust , salt etc and testing on completion, complete all as specified and directed by Engr-in-Charge. Note: IR Value should be less than 5 Ohms.
Material & Labour Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of following sizes-Make-Denson/Siemen, , complete all as specified and directed by Engr-in-Charge. 25 sq mm to 50 sq mm
70 sq mm to 150 sqmm
Taking out UNSV LT UG cables of any sizes from trenches ,retrieving of cover and stacking for reuse, complete all as specified and directed by Engr-in-Charge.
Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area. Make: Polycab/ Asian/ Gloster, complete all as specified and directed by Engr-in-Charge. 35 Sqmm 4 Core
25 Sqmm 3.5 Core
16 Sqmm 4 Core
95 Sqmm 3.5 Core
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick , complete all as specified and directed by Engr-in-Charge.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point , complete all as specified and directed by Engr-in-Charge.
Laying unreinforced precast concrete cable cover , retrieved complete all as specified and directed by Engr-in-Charge.
Supply and laying only unreinforced precast concrete cable cover , class LV type 1 flat size 250 mm x 150mm x 40 mm with ISI mark factory made , complete all as specified and directed by Engr-in-Charge.
M&L dry sand cushioning to UG cable with a layer of sand of 8 cm thick before laying of cable and 15 cm thick aftr laying of cable to full width of trenches , complete all as specified and directed by Engr-in-Charge.
Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories all as specified and directed by Engr-in-Charge. Note: (i) Cutting of floor/ road and making good with PCC deemed to be included in item rate Make: Rex/Poly/Geminie 63 mm OD
Supply and fix in replacement MCCB 4 pole 100 Amps of Breaking capacity 25KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement MCCB 4 pole 63 Amps of Breaking capacity 16KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement MCCB 4 pole 160 Amps of Breaking capacity 25KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement of Contactor 3 pole of cap 40 Amps complete all as specified and directed. Make : ABB/LT
EXTERNAL ELECTRIC SUPPLY (HT DISTRIBUTIONSYSTEM) Cutting & removing existing joint and supply, jointing and testing outdoor type Heat hrinkable straight through cable joint including all material and accessories suitable for 3 core X 95 Sqmm XLPE cable of 11000 volts grade , complete all as specified and directed by Engr-in-Charge. Make:- RPG/RAYCHEM/DENSON.
Cutting & removing existing joint and supply, jointing and testing indoor type heat shrinkable end termination cable joint including all material and accessories suitable for 3 core X 95 Sqmm XLPE cable of 11000 volts grade, complete all as specified and directed by Engr-in-Charge. Make:- RPG/RAYCHEM/DENSON
M&L for Dehydration/Filteration of tranformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV complete all as specified and as directed by Engr-in-Charge.
M&L Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement all as specified and as directed by Engr-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Comperehensive maintenance of HT panel, detection of defective components, replacement of wornout parts and servicing/cleaning of mechanical components through authorised service centre of VCB manufacturer /OEM or skilled VCB repairing agency, re-insertion oftrolly in HT panel, testing for smooth complete all as specified and directed by Engr-in-charge. Note: Worn out parts shall be measured & paid seperately under respective items.
Supply only parts/items for HT panel Numerical relay for earth fault over current/short circuit, 24V/30V DC operated and setting at site complete all as specified and as directed Make: CG/L&T MC16C/AREVA
Motor cut off Limit switch Make: BCH/L&T/C&S
Closing coil 24V DC Assembly
Shunt trip coil 24V DC
INTERNAL ELECTRIC SUPPLY Annual Comprehensive maintenance, servicing and testing of Split type air conditioners of capacity 1.5 ton/2.0 tr of any make complete by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing , oiling, greasing of blower motor, checking and removing any vibration and leakage ensure cutting of compressor / heater in case of failure of blower motor, Gas charging and testing after fixing at site, complete all as specified and directed by Engr-in-Charge. Note:(a) Cost of any minor nature repair / items such as nuts ,bolts, washers, screws, rubber mounting pads of compressor etc and labour required for removing / refixing including transportation of equipment and repair of PCB is deemed to be included in the unit rate of this items.
Supply and fix in repair u/s hermetic sealed rotary compressor with new compressor capacity not less than 19000 BTU/hr single phase, including gas charging in the system, complete all as specified and directed by Engr-in-Charge.. Make : Tecumseh/Toshiba
Supply and fix in repair u/s hermetic sealed rotary compressor with new compressor capacity not less than 24000 BTU/hr single phase, including gas charging in the system, complete all as specified and directed by Engr-in-Charge Make : Tecumseh/Toshiba
M&L for rewinding of blower motor or condenser fan motor, replacement of wornout bushes, complete of split type air conditioner complete all as specified and directed by Engr-in-Charge. Note: Cutting of wornout wiring deemed to be included in unit rate
Taking down carefully burnt out aluminium/copper circuit wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, etc to be measured and paid for seprately) making good to the disturbed surfaces of walls ceilings and floors etc , complete all as specified and directed by Engr-in-Charge.
M&L Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets and fan regulators complete all as specified and as directed by Engineer-in-Charge. for the following:- Make of cable: Havells/ Finolex/ RR Kable/ KEI (a) One light point /fan point controlled by one switch with cable 1.5 Sqmm
One bell point controlled by push button on the same board with other switch.
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket oulet 5/6 amps on independent board..
M&L Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 2.8mm thick bakelite sheet white/coloured top cover for mounting of modular switches, sockets and fan regulators complete all as specified and as directed by Engineer-in-Charge. for the following:- Make of cable: Havells/ Finolex/ RR Kable/ KEI (a) one 3/5 pin 15/16 Amps socket
M&L for sub main wiring with two run of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
M&L for sub main wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
S&F in replacement MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, complete all as specified and directed by Engr-in-Charge. Make Hager/ L&T/ Legrand.
Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ , complete all as specified and directed by Engr-in-Charge. Note- worn out parts shall be measured as separately.
Supply only spare parts for Geyser Heating element 1.5 KW with rubber gasket . Make-bajaj Model Cladia
Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
Hot/Cold water connection pipe 450 mm length.
3 core 1.5 sqmm PVC insulated cable 1.5 m long with 3 pin 15 Amp plug top
Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia
Supply and fix hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler , complete all as specified and directed by Engr-in-Charge. Make : Copeland/Tecumseh. Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate.
Taking out burnt unserviceable condenser fan motor, rewinding electric motor, single phase 230 Volts of water cooler 40 ltrs/Hrs with super enameled copper wire of same gauge, complete all as specified and directed by Engr-in-Charge.
Supply and fix relay for water cooler of capacity 40/80 ltr/hrs, complete all as specified and directed by Engr-in-Charge. Make: Renetor/ Shriram /Dunfoss.
Supply and fix Thermostat for water cooler capacity 40/80 ltr/hrs, complete all as specified and directed by Engr-in-Charge. Make:Renetor/shriram/Godraj/Danfoss
Supply and fix PVC Float valve with epoxy coated aluminium arm , with PVC polythene ball suitable for water coolers, complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing and connections of upto 25 mm bore , including cleaning or removal to store, complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ , complete all as specified and directed by Engr-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge..
Dismantling of Exhaust fan 250mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge.
S&F in repair 10 Watt LED batten luminaire suitable for wall mounting of capacity 10 Watt 2 feet long with voltage range 100-240 volts and inbuilt protection,complete all as specified and directed by Engr-in-Charge. Make: Wipro(LL20-111-XXX-65-NE3) or equivalent in Philips/Crompton Greaves.
S&F in repair 20 Watt LED luminaire, nominal lumen output 2000 lm, extruded aluminum housing, IP20,voltage range 140-270 volts PF>0.9, wall mounted, complete all as specified and directed by Engr-in-Charge. Make: WIPRO (LL20-281-XXX-65AL1) or equivalent in Philips/Crompton Greaves
S&F in replacement surface mounted 18 Watt LED luminaire, nominal lumen output 950 lm, IP 20, pressure die cast aluminium ,operating voltage range 140-270 volts,system efficacy > 60lm/W THD<10%, PF>0.9, complete all as specifie0d and directed by Engr-in-Charge. Make: Wipro Cat part No- LD80-171-XXX-60-SM or equivalent in Philips/Crompton Greaves
S&F in replacement LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt,thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires complete all as specified and as directed by Engineer-in-Charge. Make :Wipro (LD06-221-XXX-57-XX) or equivalent in Philips/Crompton Greaves
S&F in replacementr 9 W 3000 colour Lumens LED spot light with multiple beam tilting angles, no UV radiation and dimmable ballast Make : Wipro Cat part No LD98-131-024-40-XX or equivalent in Philips/Crompton Greaves
S&F in replacement 6 watt under water colour changing light hard chrome plated stainless steel with silicon sealed glass suitable for fountain including DMX driver and DMX controller complete all as specified and directed by Engr-in-Charge. Make : Wipro Cat No. LU03-950-030-CC-XX or equivalent in Philips/Crompton Greaves
S&F in Replacement of u/s light any type LED flood light 150 Watt LM6 high pressure die cast aluminium housing, IP 66, Nominal Lumen output 14000 lm, Colour temprature 5700K, THD<10%, PF>0.95, Operating Voltage 140-270V AC, 50HZ , complete all as specified and directed by Engr-in-Charge. Make: Wipro cat part No-LF20-192-060-57-G2 or equivalent in Philips/Crompton Greaves
S&F in Replacement of u/s LED street light of capacity 60 Watt, LM6 high pressure die cast aluminium housing, IP 66 protection , THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engr-in-Charge. Make: Wipro Cat Part No LR07-671-XXX-57-XX or equivalent in Philips/Crompton Greaves
S&F in Replacement of u/s LED building security light of capacity 30 watt , LM6 high pressure die cast aluminium housing, IP 66 protection , THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engr-in-Charge. Make: Wipro cat part No-LR02-331-XXX-57-XX or equivalent in Philips/Crompton Greaves
S&F LED Bollard light Cool white 6500 K of wattage 14 watt with integrated mounting base plate and driver complete with housing dark grey RAL 7043 with long life time of 50,000 hours (70% lumen maintenance @ Tc = 35ºC), IP65 protection and IK10 impact resistance including PCC (1:2:4) foundation of suitable size for mounting of light fitting including mounting pole with accessories not less than 1.2m height complete all as specified and directed. Make : Philips Cat No. BCP400 LED09 D CW PSU GR S1 or its equivalent in Wipro.
S&F LED Bollard Light Cool White of wattage 8.50 Watt 6500 K with with integrated mounting base plate and driver complete with housing dark grey RAL 7043 IP 65 protection, Resistant to corrosion and Better optics for uniform distribution including PCC (1:2:4) foundation of suitable size for mounting of light fitting complete all as specified and directed. Make: Wipro/Philips
S&F LED Bollard light Cool white 6500 K of wattage 17 watt with integrated mounting base plate and driver complete with housing dark grey RAL 7043 with long life time of 50,000 hours (70% lumen maintenance @ Tc = 35ºC), IP65 protection and IK10 impact resistance including PCC (1:2:4) foundation of suitable size for mounting of light fitting including mounting pole with accessories not less than 1.2m height complete all as specified and directed. Make : Philips Cat No. BCP400 LED09 T CW PSU GR S1
Supply and fix in replacement following items for maintenance of Internal Electrification complete all as specified and directed by Engr-in-Charge. Lamp holder for Batten fitting.
Piano switch, flush type 5 Amps, 1 way.
Piano switch, flush type 5 Amps, 2 way.
Bell push, flush type 5 Amp.
Electric bell Ding Dong type , 230 Volts Single pole.
Socket Outlet 2 in 1, 3 pin, 6A
Switch socket combination, 6 Amps flush type.
Switch socket combination, 16 Amps flush type.
2.5 mfd Capacitor
Stepped type electronic fan regulator
S&F Modular switch 6/10 A, 1 way, 1 Module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider
S&F Modular switch 16 A, 1 way, 1 Module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider
S&F Modular socket 6/16 A, 2/3 pin combined , 2 Module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider
S&F Modular Fan regulator 120W, 2 module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider
Supply and fix in replacment MCB of following rating Make legrand/Siemens/L&T, complete all as specified and directed by Engr-in-Charge. 5-32 Amp SP ,240 volt 'C' series, 10 KA
32 Amp SPN ,240 volt 'C' series, 10 KA
32 Amp TPN,440 volt 'C' series, 10 KA
63 Amp TPN,440 volt 'C' series, 10 KA
Comprehensive maintenance of RO Water Purifier 15 Ltr/Hr servicing in every 03 months by OEM rep and comprising of replacement of following:- (a) Filter (Sediment/Carbon Filter) (b) Replacement of minor parts such as SP stem, union male elbow, branch etc deemed to be included in quoted rate (c) Major parts will be measured and paid separately Make : Kent ACE+ 7Litre RO+UF
Supply and fix in replacement of following spares for RO water Purifier:- SMPS
Solenoid Valve
RO Membrane
UF Membrane
EXTERNAL WATER SUPPLY Supply and fix in replacement 3- layer PP-R Polypropylene random copolymer)pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for water supply all PP-R plain & brass threaded polypropylene random including fittings laid in Wall/ceiling/floors for 25mm bore dia pipe
Supply and fix in repair PP-R Ball valves (brass insert) as per requirement of the site for 25 mm dia bore pipe
M&L in repair for sluice valve PN 1.6, (ISI Marked) with flange ends any pattern including taking down old existing sluice valve with new Nut, bolts, washers, rubber packing etc , complete all as specified and directed by Engr-in-Charge of the following sizes. Make: Zoloto/ Kirloskar 100 mm bore
150 mm bore
Dismantling monoblock pump set centrifugal type of cap 25 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc and reassembling the complete pump after repairs and replacement of parts as required, refixing the same at site incl. electric and piping connections complete, checking for satisfactory working all as directed by Enginner-in-charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate
Dismantling open well type monoblock pump set of cap 5 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including . electric and piping connections complete, checking for satisfactory working all as directed by Enginner-in-charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate
Supply and fix in replacement cast iron Foot valve cap 80 mm complete all as specified.
Supply and fix in replacement NRV of bore dia 80 mm complete as specified and directed
Comprehensive maintenance of RO Water Plant of capacity 1000 Ltr/Hr servicing by OEM rep and comprising of replacement of following:- (a) Cartridge 20'' Filter (b) Anti Scalent Chemical (c) Mambrance 4040 (d) Solenoid valve etc (e) Replacement of minor parts such as SP stem, union male elbow, branch etc deemed to be included in quoted rate (f) Major parts will be measured and paid separately Make : Ion Exchange
Supply and fix in replacement of following spares for RO water Plant 1000 Ltr/Hr :- Cartridge 20" filter
Anti scalent chemical
Membrane 4040
Tubing
Solenoid Valve
UV Lamp
Comprehensive maintenance of RO Water Plant of capacity 8000 Ltr/Hr servicing by OEM rep and comprising of replacement of following:- (a) Jumbo Filter 20'' (b) Anti Scalent Chemical (c) Chlorine TCCI 90 (d) Solenoid valve etc (e) Replacement of minor parts such as SP stem, union male elbow, branch etc deemed to be included in quoted rate (f) Major parts will be measured and paid separately Make : Ion Exchange
Supply and fix in replacement of following spares for RO water Plant 8000 Ltr/Hr :- Jumbo Filter 20"
Anti scalent chemical
Chlorine TCCI 90
Tubing
Solenoid Valve
UV Lamp
Supply and fix in replacement of following items for drip and sprinkler system:- Popup sprinkler VAN15 model
PVC Ball valve 63 mm
Saddle 63mmx½"
Saddle 50mmx½"
Dripper
Emitting pipe 16-4-30
Plain lateral 16 mm
Swing joint ½"
Disc filter 30m3/Hrx2"
K K Construction Co
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .