Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹31.8 L+₹3.5 L (12.3%)Rejected-AOC H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC ok | |
| 3 | L3₹32.2 L+₹4.0 L (14.0%)Rejected-AOC 239 PHASE 2 MODEL TOWN BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L3 | Rejected-AOC ok | |
| 4 | L4₹33.9 L+₹5.6 L (19.8%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC ok | |
| 5 | L5₹35.5 L+₹7.2 L (25.4%)Rejected-AOC | L5 | Rejected-AOC ok |
Tender Value
₹38.3 L
EMD Value
₹76,700
Closing Date
2 Mar 2022, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
SPECIAL REPAIR FOR OFFICERS MD ACCN NO P-36 AT BINDAL BRIDGE UNDER GE DEHRADUN.
2022_MES_505382_1
9686/DDN/E8
Open Tender
Civil Works
Item Rate
120 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Dehradun
₹76,700
Yes
18 Apr 2022
2 Feb 2022
4 Mar 2022
2 Feb 2022
2 Mar 2022
16 Feb 2022
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plastering of any description on brick/stone/concrete wall surfaces of any description incl racking out joints hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished surfaces even and smooth complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1:3 on fair faces of concrete work even and smooth as in ceiling complete all as specified and directed.
M&L for preparation of new plastered surface of walls including corners and applying two coats of distemper oil emulsion over applying of 2-3mm thick wall care putty finish wall surface even & smooth by roller complete all as specified and directed.
M&L for complete removal of existing treatment of walls including corners and applying two coats of distemper oil emulsion over and including of 2-3mm thick wall care putty, finishing wall surface even & smooth by roller complete all as specified and directed.
M&L for preparation of walls surface and applying two coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surface of external wall with scrapping, wire brushing, washing with water and applying two coats of exterior grade 1st quality weather coat paints over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for complete removal of existing treatment painted surfaces of external wall with scrapping, wire brushing, washing with water and applying two coats of exterior grade 1st quality weather coat paints over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation on new steel surfaces of any description over 10 cm width or girth complete all as specified and directed.
Preparation of old Steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden painted surfaces including preparation and applying two coat of synthetic enamel paint any description, over a coat of pink primer, not otherwise described over 10 cm width/girth complete all as specified and directed.
M&L for preparation of old painted surfaces of wood over 10 cm width/girth and applying one coat of synthetic enamel paint all as specified and directed.
Dismantling floor hearth or wall tiling including cement motor bedding (but not backing), removing serviceable tiles to stone and rubbish off the premises complete all as specified and directed.
M&L for vitrified ceramic tiles dark shed /double charged 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. including screed bed 15 mm thick in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile complete all as specified and directed.
All as per item No 17 above but as in skirting/dado over and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
M&L for non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x 6- 7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and dismantling of existing tiling including cement mortar bedding (but not backing) and removal of rubbish from the premises complete all as specified and directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces of size 300mm x600mm x6-7mm/ 300x 450 x 6-7mm thick over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Demolition of stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
S&F granite 18-20mm thick of any type table rubbed and polished in steps, jambs pillars, window cill, cooking platform and like in cement mortar 1:4 including pointing in white cement complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement and demolition of existing old cement concrete of plinth protection in ground floor and paving below or above ground level complete all as specified and directed.
M&L for Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Taking down chowkat with shutter n. exc 1.5 Sqm each complete all as specified and as directed by Engr-in-Charge.
Taking down chowkat with shutter exc 1.5 Sqm but n.exc 4 Sqm each complete all as specified and directed.
Taking down shutters of any description exc 1 sqm n.exc 2 sqm each and re fixing in same opening after necessary repair complete all as specified and directed.
Taking down shutter n.exc 1.00 sqm each complete all as specified and directed.
Material and labour for Second class hard wood plain solid straight chowkats and frames wrought, framed, rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
Supply and fix flush shutters 35 mm thick one face is covered with decorative face veneer teak wood finished with lipping/frame to match , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F 35mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) and as directed.
S&F factory made steel windows with side hung shutters including box type hinges with MS handles and tower bolts complete with glazing bars dovetailed or welded with one shop coat of primer complete all as specified and directed.
S&F factory made steel windows with side hung shutters including box type hinges with MS handles and tower bolts complete without glazing bars, as fly proof shutters with one shop coat of primer complete all as specified and directed.
S&F factory made steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
S&F PVC solid factory made door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F Factory Made Solid PVC Moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as shown in SSR Part – II 2010 and as directed.
S&F mild steel flat iron for hold fasts and similar articles complete all as specified and directed.
M&L for cutting holes in brick wall built in cement mortar exc half brick but n.exc one brick for inserting or cement concrete 1:2:4 hold fast etc and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed.
S&F 200 mm long, solid in one piece stainless steel barrel tower bolts complete all as specified and directed.
S&F 150 mm long, solid in one piece stainless steel barrel tower bolts complete all as specified and directed.
S&F 150mm size solid in one piece stainless steel handles, cast D type, fixed in stainless steel complete all as specified and directed.
S&F 125mm size solid in one piece stainless steel handles, cast D type, fixed in stainless steel screws all as directed complete all as specified and directed.
S&F 100 mm size stainless steel butt hinges and fixed with stainless steel screws, complete all as specified and directed.
S&F 75 mm size MS butt hinges medium weight cold rolled fixed/ welded to frame complete all as specified and directed.
S&F stainless steel sliding door bolts 204 grade, hasp and staple type with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 250mm long complete all as specified and directed.
S&F stainless steel 304 grade wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples with 8% nickle complete all as specified and directed.
Hacking out old broken glass ( any thickness , size, quality, or description) from wooden frame glazed with putty or fixed with beads all as specified and directed
M&L sheet glass ordinary quality 4mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n. exc. .5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed.
S & F continuous (Piano) hinges, mild steel, bright finished or stainless steel 304 grade, width of flaps (When open) 30 mm complete all as specified and directed.
S&F stainless steel CP semi hydraulic albehari hinges complete all as specified and directed.
S&F magnet catcher for cub board with brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F in repair peg set of five stainless steel fixed on CP steel plate 304 grade including fixing screw complete all as specified and directed.
S&F in repairs glass corner shelf suitable size made of 5mm thick toughned glass complete all as specified and directed.
S&F in repair 25 mm dia stainless steel polished 204 grade drapery rod 1mm thick with final decorative, including brackets, decorative finished at both ends complete all as specified and directed.
S & F solid PVC wall Lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing including removing existing unserviceable wall lining complete all as specified and directed.
S&F in repairs CP brass soap dish 6 inches complete all as specified and directed.
S&F in repair PVC Shelves 450mm of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105 gms) complete all as specified and directed.
S&F in repair plate rack 300mm and size 100 x 80 cm made out of 1.00 mm thick stainless steel sheet complete all as specified and as directed.
S&F in repairs stainless steel kitchen sinks without draining board ISI marked made of stainless steel 1 mm thick, with plugs, washers and wastes, including bedding lime cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed.
Demolition of reinforced cement concrete, shelves, chajjas, slabs and similar work carefully and matching to adjoining disturbed surfaces complete all as specified and as directed.
M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and colums, in floors, roofs, landing balconies, canopies, deck slabs, chajja and in shelves and the like, complete all as specified and directed. Note : The work will be carried out up to triple storey building, the rate of scaffolding is included for in the quoted rates.
Use and waste form work for RCC Slab such as roof slab, chajja, floor slab etc complete all as specified and as directed.
Use and waste form work to edges of concrete flats, treads, break in floor & roofs n. exec 20 cm wide horizontal or sloping and similar works complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in cills, copings, benching on chajjas, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
S&F mild steel TMT MS bar 8 mm dia & over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and as directed.
S&F in repair mild steel framed work for such as grills, gratings, etc., with ends of bars shouldered or riveted, or forged into spikes; framed guard bars; barred iron doors and similar work conforming to Fe 210,Gde E-165 complete all as specified and as directed.
Taking up or down steel tubing and connections with all fittings for 15 mm bore GI tubing complete all as specified and as directed.
Taking up or down steel tubing and connections with all fittings for 20 mm bore GI tubing complete all as specified and as directed.
M&L for cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth complete all as specified and as directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing complete all as specified and as directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing complete all as specified and as directed.
S&F rotational moulded polyethylene 1000 Ltrs Capacity water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float three layer external and internal white and fly nut complete screwed down for iron pipe of 20 mm dia complete all as specified and as directed.
S&F in repair ball valve high pressure of PTMT with epoxy coated alum rod & high density plastic ball screwed for 15mm bore iron pipe and fixed ( minimum weight 20mm -210 gms) complete all as specified and directed.
S&F in repair CP toilet paper holder complete all as specified and as directed.
S&F in repair CP brass wall mixer for 15 mm dia bore with Telephonic shower, complete all as specified and as directed.
S&F in repair CP Brass 3 in 1 hot & cold 15 mm dia wall mixer for mixing hot & cold water with telephonic shower provn with connecting legs & flanges complete all as specified and directed.
S&F in repair CP brass Central hole basin mixer fancy type 15mm dia all as specified and directed.
S&F in repair CP brass bib tap fancy type short body15mm bore screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repair 15mm bore Bib taps long body, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore Angle cock/stop valves (2 in 1), cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair PVC Health Faucet with 1 mtr metallic expandable tube & hook complete all as specified and as directed.
S&F in repairs 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified and as directed.
S&F in repair brass chromium plated over head shower with shower arm complete all as specified and directed.
S & F in repairs wash down water closet (EWC) white with P or S trap including Flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern and plastic water closet seat & cover mild steel chromium plated or aluminised hinging device and connection to low level flushing cistern and flush pipe, etc complete all as specified and as directed.
S&F of 40mm outer dia of CPVC pipe class 1 on wall /ceiling or laying in floor incl of all fitting i.e elbow, tee and socket etc, complete all as specified
S&F vitreous china, white, oval shape wash hand basin, flat size 550 x 400 mm including MS brackets including 12 to 15mm thick pre polished mirror granite fixed on RCC slab 1:11/2:3, 50mm thick with steel reinforcement (paid separately) cutting for and pinning in ends of brackets but excluding Waste pipe & with 32mm (PTMT) waste coupling (half or full threaded) minimum weight 32gm-45gms) & 15mm bore CP pillar tap supply only 25mm dia PVC (LDPE) of pressure 6Kg/cm2 down pipe 75cm long complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts, of 450 mm length complete all as specified and as directed.
Taking down AC/Salt glazed ware pipes and fittings up to 110mm dia bore complete all as specified and as directed.
S&F in repairs for 100mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed.
S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls complete all as specified and directed.
S&F PVC (SWR) pipes of 75 mm dia, single socketed fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) bends of 75 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) junction single Tee equal or unequal 110 mm dia complete all as specified and directed.
S&F PV C (SWR) junction single Tee equal or unequal 75 mm dia complete all as specified and directed.
PVC (SWR) floor trap, plain with grating including jointed with solvent cement of 75 mm outlet dia complete all as specified and directed.
S&F in repairs PVC waste pipe not less than 60cm long with PVC coupler for kitchen sink, WHB, urinal, etc complete all as specified and as directed.
S&F in repair stainless steel sink coupling with waste pipe complete all as specified and directed.
S&F in repair CP steel Grating round with steel frame with hinge 100mm dia complete all as specified and as directed.
S&F in repair WPC board 18-19mm thick, medium density, flat pressed, single layer type or three layer type, BWR grade complete all as specified and as directed.
S&F in repairs fancy type 5.50mm thick looking mirror with PVC moulding 40mm wide all around with back 5mm thick PVC board of size 450x600x5mm thick complete all as specified and directed.
M&L for water proofing treatment on roof slab including picking, sweeping clean and washing down with water to remove dust & providing water proofing treatment described as under:- (a) Surface preparation with Asian smart care mortar and GP groute mortar and treating of construction joints, filling of honey combs with polymer modified mortar (Cement: Sand : smart care multipurpose polymer of Asian Paints or equivalent product of Thermax/ Berger ) (b) Cleaning the surface and applying (Resin & Hardener) smart care Epoxy Primer 2k of Make Asian paints or equivalent product of Thermax/ Berger ) on the cleaned surface for bonding of PU magnum with the existing concrete surface. (c) Supplying, providing and applying waterproofing treatment to Terrace area with Asian Paints Smart care PU magnum, single component highly elastomeric seamless cold applied modified PU coating or equivalent product of Thermax/ Berger) including all necessary surface preparation, coving using smart care multipurpose polymer, water pond test, etc. complete as per manufacture's specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1mm. The coating shall have dual combination of 250% elongation . Execution to be done with authorized applicator of the manufacturer and company back guarantee to be given by the contractor. Work will be executed in smart assurance system
Taking down carefully existing aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete and making good the disturbed surfaces of walls, Floors, ceilings etc to match with existing complete all as specified and directed.
M & L for point wiring complete with PVC insulated and unsheathed, Flame retardant low smoke ( FRLS ) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core in and including rigid PVC concealed conduit not less than 19 mm dia, clip, complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron/steel suction box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire up to common earth and connected to earth dolly complete all as specified including lugs required for One light/ceiling fan/Exhaust Fan point controlled by one switch, complete all as specified and directed.
All as per item No 104 above but for one 5 pin 5 Amp socket outlet point on same board.
All as per item No 104 above but for one 5 pin 5 Amp socket outlet point on independent board.
All as per item No 104 above here in before but with 2.5 Sqmm copper conductor cables (multi stranded) PVC insulated FRLS, unsheathed cable and including 2.5 Sqmm copper conductor cable (multi stranded) PVC insulated FRLS and unsheathed cable earth continuity wire to common earth and connecting to earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed.
S&F step type, electronic fan regulator 120 watts, 5 step for ceiling fan 1200/1400 mm sweep 230 volts AC complete all as specified and directed.
S&F switch piano flush type single pole, 5 Amps, one way complete all as specified and directed.
S&F switch piano flush type single pole, 20 Amps, one way complete all as specified and directed.
S&F socket outlet 6 Amps, 5 pin, 2 in 1 complete complete all as specified and directed.
S&F socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified & directed
M & L for point wiring complete with PVC insulated and unsheathed, Flame retardant low smoke ( FRLS ) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core , drawing through existing conduit (without socket, elbow, junction box, bell mouth, bend, reducer , pressed iron/steel suction box , 3 mm thick plastic laminated sheet) and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire up to common earth and connected to earth dolly complete all as specified including lugs required for One light/fan point/bell point controlled by one switch, complete all as specified and directed.
All as per item No 113 above but point wiring for one 5 pin 5 Amp socket outlet point same board complete all as specified and directed.
All as per item No 113 above but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed.
All as per item No 113 here in before but with 4 Sqmm copper conductor cables (multi stranded) PVC insulated FRLS, unsheathed cable and including 4 Sqmm copper conductor cable (multi stranded) PVC insulated FRLS and unsheathed cable earth continuity wire to common earth and connecting to earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified
S & F modular fan regulator electronic rotary,0-4 steps step type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified and directed.
S&F switch modular 6 Amps 230 Volts one way switch complete all as specified and directed.
S&F socket modular 6 Amps AC 230 Volts 2/3 pin combined 2 modular type complete all as specified and directed.
S&F socket 6A/16 Amps-2/3 pin combined AC 230 Volts modular type complete all as specified and directed.
S&F switch modular type AC 230 volts 16 Amps one way complete all as specified & as directed.
S&F modular bell push 6 Amp one module one way complete all as specified and directed.
S&F GI sunken box with flush metal GI box 2 module suitable for modular switches incl plastering, making good disturbed surfaces of wall, painting to match the existing finishes complete all as specified and directed.
All as per item No 123 here in above but 3 module.
All as per item No 123 above here in above but 4 module.
All as per item No 123 above here in above but 6 module.
All as per item No 123 above here in above but 8 module
All as per item No 123 above here in above but 12 module
S&F combined cover plate white 2 module suitable for modular switches complete all as specified and directed.
All as per item No 129 here in above but 3 module.
All as per item No 129 here in above but 4 module.
All as per item No 129 here in above but 6 module.
All as per item No 129 here in above but 8 module.
All as per item No 129 here in above but 12 module.
S&F ceiling rose surface bakelite 3 terminals of size 65x25mm complete all as specified & directed.
S&F Calling bell ding dong complete all as specified & directed.
S&F LED tube light alluminium extruded body with integrated electronic driver, 20 W, 4 feet complete all as specified and directed.
S&F decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base. 1 N x 9 W LED Lamp/1 N x 7.5 W LED filament lamp complete all as specified and directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED Mirror light fitting tube light alluminium extruded body with integrated electronic driver along with fixture, 10 W complete all as specified and directed.
S&F LED Flood light fittings. die-cast aluminium housing IP66 50/60 W,6000K, 100 lumens/ watt or nearest higher size watt or higher size, fixed on pole duly fixed on angle iron bracket complete all as specified and directed. Note:- Test certificate shall be submitted by the contractor to the GE.
S&F BLDC Ceiling Fan complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated PVC AC single Phase 230 V / 240V 50 Hz of , complete connecting up ceiling rose to connector block of fan including fabricating and fixing of Fan hooks from ceiling truss/angle iron, required length of down rods (as per site requirement) and necessary nuts and bolts complete all as specified and directed. Note:- Old unserviceable ceiling fan shall be deposited to MES store Yard.
S&F in replacement exhaust fan 150 mm PVC body made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block including taking down old metallic exhaust fan complete all as specified and directed. Note : Old unserviceable exhaust fan shall be deposited to MES store yard. Note:- Test certificate shall be submitted by the contractor to the GE.
S&F in replacement exhaust fan exhaust fan metallic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block including taking down old metallic exhaust fan complete all as specified and directed. Note : Old unserviceable exhaust fan shall be deposited to MES store yard. Note:- Test certificate shall be submitted by the contractor to the GE.
S&F replacement Water heater storage type, electric, capacity 35 liters AC single phase 230/ 240 V o and connecting up including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Note:- Test certificate shall be submitted by the contractor to the GE. Old unserviceable geyser will deposit to MES store yard.
S&F TPN DB VTPN 4 way 415 Volts, 50 Hz indoor type double door Sheet metal enclosure IP-43 DB's flush mounted with 250 Amp Copper bus bar for each phase with two neutral bar & two earth bar and cable ties for cable management including mounting arrangement including DPX3 MCCB 250 Amps four pole 415 volts as incomer including connection terminal strip complete pre wired with suitable size copper conductor. The DB's shall hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed.
S & F sheet metal enclosure TPN for DB's when MCB's to be used 6 way with 200 amps bus bar and double door complete all as specified and directed.
S&F MCB TPN 63 Amps 10 kA, 430 Volt complete all as specified & directed.
S&F sheet metal enclosure SPN for DB's when MCB's to be used 6 way with 200 amps bus bar and double door complete all as specified and directed.
S&F metal clad single pole and neutral enclosure with 2 pin and earth plug and socket complete with and including one single pole MCB 20 Amp 240Volt complete all as specified and directed.
S&F MCB SPN 240 Volt 10 KA 6 to 40 Amp 'C' series conforming to IS complete all as specified & directed.
S&F MCB SP(single pole) 240 volt, 10 KA, 6-40 Amp, 'C' series confirming to IS complete all as specified and directed.
M&L for sub main wiring with 3 runs (P+N+Earth continuity conductor) of 2.5 Sqmm single core, PVC insulated, unsheathed, multi stranded copper conductor FRLS cable 1100 volts grade recommended colour code ,drawn through and including concealed PVC conduit pipe of medium duty not less than 15 mm dia including necessary PVC conduit specials and connecting all wires with suitable size thimble complete all as specified and directed. Note:-3 runs of 2.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 153 here in above but sub main wiring with 3 runs of 4 Sq mm wire (P+N+Earth continuity conductor) complete all as specified and directed. Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC Case & Capping shall be measured as one unit length.
All as per item No 153 here in above, but sub main wiring with 6 runs (3 run Phase +1 for Neutral +2 for Earth continuity conductor with approved colour as per EI rule) of 6 Sq mm conductor drawn through concealed conduit of size not less 32 mm dia complete all as specified and directed. Note:-6 runs of 6 Sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length.
M&L for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized iron wire 4 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/ Lt panel etc. and testing on completion, complete all as specified and directed.
Supply and Laying XLPE insulated galvanised steel strip or wire armoured electric power cable with stranded aluminium conductor 1100 V grade of size 70 sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts, and lugs complete all as specified and directed
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unserviceable LT Cable complete all as specified and directed.
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete all as specified and directed. Note :- Only punned down sand thickness 18CM shall be measured and paid
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supplying and laying old size bricks, laid flat ie length of brick shall be laid across the cable, common burnt clay building bricks sub class `B' designation 75 complete all as specified and directed and testing on completion complete all as specified and directed.
Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for GI Tubing Light grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc of size 50mm dia complete all as specified and directed.
S & F micro processor based 3 phase electronic tamper proof, static energy meter with optical communication port confirming to IS 13779 of accuracy class 1.0, 3 X 240 V, 50 Hz with Backlit LCD display of rating 10 - 60A (suitable for measurement of KWH only) complete all as specified & directed. Note:- Old meter shall be deposited to MES store yard.
S&F Meter Distribution board made out of Thermoplastic polycarbonate of size 600x600x170 mm (dust proof & weather proof ,Shock proof, rust proof ,corrosion free ,acid & Chemical resistance ,UV resistance , Halogen free & free recyclable material) with 230v Ac 50 HZ 3 Wire , Gasket shall be embedded with T-locking arrangement and suitable for mounting of Electronic Meter -04 Nos including electrical connection with existing system and sealing properly & taking out unserviceable broken/rusted box of any size and type complete all as specified and directed.
M/s Pradeep Kumar
SARASWATI CONSTRUCTION CO
M/s Anil Kumar
M/S DHYANI CONSTRUCTION CO.
TANUJ SAINI CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .