| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹518Accepted-AOC | ₹518 Quoted ₹5.2 Cr | L1 | Accepted-AOC Accepted |
| 2 | Rejected-Technical | - | - | Rejected-Technical disqualified |
Tender Value
₹5.3 Cr
EMD Value
₹2 L
Closing Date
5 Oct 2023, 2:00 pmClosed
SUPERINTENDING ENGINEER
SUPERINTENDING ENGINEER PH CIRCLE,KWA, ALAPPUZHA
Jal Jeevan Mission (JJM)-CWSS to Harippad and adjoining Panchayaths- Electromechanical works- Pumps, Transformer, VCB, Main Control Panel, RMU etc. in WTP at Pallippad, and Sump at Muthukulam--General Electrical Work
2023_KWA_605829_1
RE-E-Tn No 95/2023-24/SE/PHC/ALP-RT-2
Open Tender
Civil Works - Water Works
Item Rate
180 days
MUTHUKULAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹13,010
₹2 L
PH CIRCLE,KWA, ALAPPUZHA
27 Jan 2024
23 Sept 2023
6 Oct 2023
23 Sept 2023
5 Oct 2023
23 Sept 2023
23 Sept 2023 - 27 Sept 2023
28 Sept 2023
Amount
Appendix-A- Electromechanical Work for WTP Pallipad
OD79370/2023-2024:Design, Supply and erection of centrifugal pump set with the following specification,1.Pump -Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete. The duty condition is as follows.- Discharge 45 LPS Speed up to 1500RPM,Total Head 32m, Positive Suction, Length of suction pipe 2 m, size of pumping main 600mm dia<br>pipe.Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given Modification may done for mono block pump set.
OD79369/2023-2024:Design, Supply and erection of centrifugal pump set with the following specification,1.Pump -Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete. The duty condition is as follows.- Discharge 102 LPS Speed up to 1500RPM,Total Head 72 m, Positive Suction, Length of suction pipe 2 m, size of pumping main 600mm dia<br>pipe.Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given Modification may done for mono block pump set.
OD79367/2023-2024:Design, Supply and erection of centrifugal pump set with the following specification,1.Pump -Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete. The duty condition is as follows.- Discharge 143 LPS Speed up to 1500RPM,Total Head 58m, Positive Suction, Length of suction pipe 2 m, size of pumping main 600mm dia<br>pipe. Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given Modification may done for mono block pump set.
OD79368/2023-2024:Design, Supply and erection of centrifugal pump set with the following specification,1.Pump -Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete. The duty condition is as follows.- Discharge 138 LPS Speed up to 1500RPM,Total Head 70m, Positive Suction, Length of suction pipe 2 m, size of pumping main 600mm dia<br>pipe. Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given Modification may done for mono block pump set.
OD79375/2023-2024:Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft ,foot mounted TEFC squirrel cage induction motor, 22KW,415 V,50Hz,IP 55 protection, Class F Insulation, suitable for the above pump working 3 phase 50Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation<br>including cost of cement sand and metal etc. Complete for 415 V motors digital motor protection relay shall be included in starter as per per IE rules. Flexible coupling shall be used for coupling of pumps and motors.
OD79374/2023-2024:Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor 110KW suitable for the above pump working 3 phase 50Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation<br>including cost of cement sand and metal etc. Complete for 415 V motors digital motor protection relay shall be included in starter as per per IE rules. Flexible coupling shall be used for coupling of pumps and motors.
OD79373/2023-2024:Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor 132 KW suitable for the above pump working 3 phase 50Hz AC supply, working voltage 415V . The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation<br>including cost of cement sand and metal etc. Complete for 415V motors digital motor protection relay shall be included in starter as per per IE rules. Flexible coupling shall be used for coupling of pumps and motors.
OD79372/2023-2024:Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor 160KW ,4 POLE suitable for the above pump working 3 phase 50Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation<br>including cost of cement sand and metal etc. Complete for 415V motors digital motor protection relay shall be included in starter as per per IE rules. Flexible coupling shall be used for coupling of pumps and motors.
OD78671/2023-2024:Supply, Errection, Testing and commissioning of 11KV/433V, 1000KVA, 50Hz, 3phase , Vector Group Dyn 11 Resin Cast Indoor type copper wound Transformer(IP 23) with on load tap changer with RTCC &AVR panel tapping +5% to -5% in steps of 2.5% with winding temperature scanner and hooter, provision for Bus Duct on the LV side and HV side connected with 11KV VCB panel and the LV compartment which houses ACB. . The Electrical equipments are to be cooled by natural ventilation
OD93953/2023-2024:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact Joints Totally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V, 3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earth strip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI 49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A Feeder (IP 65)
OD93959/2023-2024:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact Joints Totally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V, 3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earth strip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI 49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A Flanged end (IP 65)
OD93970/2023-2024:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact Joints Totally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V, 3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earth strip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI 49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A 90 deg elbow horizontal (IP 65)
OD93978/2023-2024:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact Joints Totally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V, 3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earth strip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI 49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A 90 deg elbow vertical(IP 65)
OD93981/2023-2024:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact Joints Totally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V, 3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earth strip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI 49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A Cu flexible
OD93985/2023-2024:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact Joints Totally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V, 3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earth strip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI 49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A Adaptor box (additional as per site condition)
OD78820/2023-2024:Supplying, laying and clamping of XLPE insulated AL HT armoured power cable, conductors of best conductivity aluminium 11KV grade of following sizes in existing cable tray / existing trench (excluding sand cushioning and protective covering) / clipping directly on wall / ceiling.
OD78822/2023-2024:Supplying all material (Termination kit) and providing indoor / outdoor end termination for existing XLPE insulated AL conductor HT power cable of the following size to the transformer HT terminal as per IS 1255. Including properly cleaning, aligning and providing mechnical support to the cable, inspection for any defects etc.
OD78831/2023-2024:Supply and installation of following Current transformer with enclosure for Neutral CT-300/5 5P10
OD94240/2023-2024:Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board for 1000KVA Transformer
OD78838/2023-2024:Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board with 2 MCCB Outgoings, Mechanically interlock & 2 Soft Starters suitable for 150 HP
OD78839/2023-2024:Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board with 2 MCCB Outgoings, Mechanically interlock & 2 Soft Starters suitable for 200HP motors
OD78840/2023-2024:Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board with 2 MCCB Outgoings, Mechanically interlock & 2 Soft Starters suitable for 220 HP
OD78841/2023-2024:Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board with 2 MCCB Outgoings, Mechanically interlock & 2 Soft Starters suitable for 30 HP
OD78843/2023-2024:Supply, Fabrication, Installation, Testing and Commissioning of Cubicle type, dust and vermin proof, floor mounted, front operated APFC Panel (400kVAR) made out of 16SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel. The switch board should have a set of suitably rated TPN Aluminium Busbars with the specified current and fault level, insulated with heat shrinkable, colour coded PVC sleeves and supported using DMC/SMC piller or finger type Busbar supports. the design should be as per the standards of the electrical inspectorate. Capacitors (APP Type), Capacitor duty contactors, APFC Relay (12 Stage), LED indication type lamps, CT's, Multifunction meter and 2A Backlite fuses are included in this panel. Incomer 800A 3P FIXED ACB ISO 800A TPN AL bus MFM RYB phase indicating lamps (LED ) with control fuses and switches -1 set. 12 stage APFC relay CT:-800/5A , CL-1 , 15VA -3Nos OUTGOING 125A 3P 25kA current limiting type MCCB with encapsulated double break mechanism - 3 Nos 100A 3P 25kA MCCB with encapsulated double break mechanism -1No 63A 3P 25kA MCCB with encapsulated double break mechanism - 8 Nos 50kVAR CAPACITOR,440V APP type capacitor withstand upto 525V having IS -13585 with 4 year replacement guarantee - 3Nos 40kVAR CAPACITOR ,440V APP type capacitor withstand upto 525V having IS-13585 with 4 year replacement guarantee - 1Nos 25kVAR CAPACITOR , 440V APP type capacitor withstand upto 525V having IS-13585 with 4 year replacement guarantee - 8Nos 10kVAR CAPACITOR , 440V APP type capacitor withstand upto 525V having IS-13585 with 4 year replacement guarantee - 1No 67kVAR CAPACITOR DUTY CONTACTOR - 3Nos 50kVAR CAPACITOR DUTY CONTACTOR - 1 No 32kVAR CAPACITOR DUTY CONTACTOR - 8Nos 16.7kVAR CAPACITOR DUTY CONTACTOR - 1No 50kVAR REACTOR ,7% F-class copper wound series reactor with thermister -3Nos 25kVAR REACTOR ,7% F-class copper wound series reactor with thermister -8Nos 10kVAR REACTOR ,7% F-class copper wound series reactor with thermister -1No 40kVAR REACTOR ,7% F-class copper wound series reactor with thermister -1No
OD78854/2023-2024:Supplying, laying and clamping of 3.5x300sqmm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling
OD78855/2023-2024:Supplying, laying and clamping of 3.5x240sqmm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling
OD78856/2023-2024:Supplying, laying and clamping of 3.5x185sqmm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling
OD78863/2023-2024:Supplying, laying and clamping of 3.5x150 sqmm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling
OD78864/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling 3cx150 sqmm
OD78865/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling- 3x120 sqmm
OD78867/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-3.5x70 sqmm
OD78868/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-3.5x35 sqmm
OD78870/2023-2024:Supplying, laying and clamping of 4x16 sq.mm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling
OD78881/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-3x16 sqmm cu ar cable
OD78897/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-4x1.5 sq.mm copper cable
OD78901/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-2x1.5 sq.mm copper cable
OD78902/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-1c x 95 sqmm copper flexible cable
OD78903/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-1c x 120 sqmm copper flexible cable
OD78906/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x400sqmm
OD78907/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x300sqmm
OD78908/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x240sqmm
OD78912/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x185sqmm
OD78916/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x150 sqmm
OD78924/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3cx150 sqmm al ar cable
OD78925/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3x120 sqmm
OD78926/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x70 sqmm
OD78927/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x35 sqmm
OD78928/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 4x16 sq.mm
OD78929/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3x16 sqmm cu ar cable
OD78931/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 4x1.5 sq.mm copper cable
OD78932/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 2x1.5 sq.mm copper cable
OD78933/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 1c x 95 sqmm copper flexible cable
OD78934/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 1c x 120 sqmm copper flexible cable
OD78943/2023-2024:Supply and providing ISI plate earthing as per IS: 3043 with 1200x1200x12mm CI earth plate with Cu strip extending to the other end of the earth plate and bolt to the plate with minimum 3 nos. of SS bolts, filling earth enhancing mineral compount of approved type around earth plate upto a distance of 15cm. with cover
OD78944/2023-2024:Supply and laying Copper strip /GI strip of the following sizes laid 0.6m below ground level excluding excavating trench of suitable size/tray and refilling etc as required 25x6mm Copper strip
OD78945/2023-2024:Supply and laying Copper strip /GI strip of the following sizes laid 0.6m below ground level excluding excavating trench of suitable size/tray and refilling etc as required 25x3mm Copper strip
OD78950/2023-2024:Fixing of 32x6 mm Cu Earth clamp (Main Earth Terminal / Earth bus) with all provision for making protective earthing system and equipotential bonding
OD78951/2023-2024:Supply and drawing bare copper conductors of the following sizes along with wiring/ cables and giving connections as required
OD78952/2023-2024:Supply and installation of 3 phase double cover MCB vertical DB IP42/43 including copper busbar, neutral link and DIN bar suitable for fixing outgoing MCB, flush mount on wall, including cutting holes on the wall making good the damage etc. as required
OD78953/2023-2024:Supply and installation of double cover enclosure of MCB DB IP42/43 for 1phase inclusive of copper/brass bus bar, neutral link and DIN bar suitable for incorporating MCB, isolator etc, flush mount on the wall including cutting holes on wall,making good the damages etc. as required
OD78954/2023-2024:Supply and installation of industrial / metal clad plug socket IP54 with MCB control and fixing on locations 20A 2P MCB
OD78955/2023-2024:Supply and installation of industrial / metal clad plug socket IP54 with MCB control and fixing on locations 32A 4P MCB
OD78957/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 63/40A FP Isolator
OD78958/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 40A TP MCB
OD78959/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 32A TP MCB
OD78960/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 16A TP MCB
OD78961/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 6A-32A SP MCB
OD78962/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 63A100mA FP RCCB
OD78964/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 40A 30mA DP RCCB
OD78965/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 40A 2P Isolator
OD78966/2023-2024:Supply Fixing of medium grade rigid PVC conduit, open or concealed as required in circuit wiring etc
OD78967/2023-2024:Supply all material and wiring for light / fan point (Primary or first point of group control lights) using 3 runs 1.5 sqmm FR PVC insulated copper wire, modular switches, front plate, MS Box, wiring connector, flexible connection using 2/3 core flexible round cables etc.,. 2 way controlled points shall counted as 2 points.
OD78968/2023-2024:Wiring for Secondary light points (looping) using 2 runs 1.5 sqmm FR PVC insulated copper wire or 1.5sqmm 3 core flexible weather proof cable.
OD78975/2023-2024:Wiring for 6A plug points in combined position using 3 runs1.5 sqmm FR PVC insulated copper wire including supply and fixing of 6A / 3 pin modular plug socket, switches and giving connections. (circuit from same switch board)
OD78976/2023-2024:Supply all materials and wiring for 6A/16A plug points in independent position using 2 runs 2.5 sqmm + 1 run 1.5 sqmm FR PVC insulated including supply and fixing of MS box, 6A / 16A 3 pin modular socket, switch, front plate, conduiting and giving connections.(with out circuit wiring)
OD79002/2023-2024:Supply and drawing PVC FRLS insulated copper wire of following size through existing conduit and giving necessary connections etc as required in the following runs 2 Runs 2.5mm² Cu wire + 1Run 1.5mm² Cu wire
OD79004/2023-2024:Supply and drawing PVC FRLS insulated copper wire of following size through existing conduit and giving necessary connections etc as required in the following runs. 2Runs 4mm² Cu wire + 1Run 2.5mm² Cu wire
OD79005/2023-2024:Supply Installation, testing and commissioning of the following items including cutting holes for recessed fittings, fixing anchor bolt for fan clamps etc. complete.(supply of lights in client scope)-LED flood lights. (50 watts)
OD79006/2023-2024:Supply Installation, testing and commissioning of the following items including cutting holes for recessed fittings, fixing anchor bolt for fan clamps etc. complete.(supply of lights in client scope)-LED Tube light
OD79007/2023-2024:Supply Installation, testing and commissioning of the following items including cutting holes for recessed fittings, fixing anchor bolt for fan clamps etc. complete.(supply of lights in client scope)-50 watts IP65 street light with 5 meter pole
OD79008/2023-2024:Supply of 11kV grade rubber gloves
OD79009/2023-2024:Providing MV voltage danger notice board 200mmx150mm
OD79013/2023-2024:Providing high voltage danger notice board 300mmx200mm
OD79012/2023-2024:Supply & fixing Laminated drawings of electrical lay out and schematic drawing, shock treatment chart etc on good frame work.
OD79011/2023-2024:Supply & installation of following electrical grade rubber mat conforming to IS standards-2mm 3.3 kV
OD79010/2023-2024:Supply & installation of following electrical grade rubber mat conforming to IS standards-21.5mm 11kV
OD79021/2023-2024:Supply and installation of emergency push button
OD79020/2023-2024:Charges for testing CT PT unit and TOD meter at TMR and recollecting the same after testing (professional charges only )
OD79019/2023-2024:Charges for testing EFR,neutral CT,other relays at meter testing and standards laboratory and obtaining certificate excluding statutory and sundry charges
OD79018/2023-2024:Charges for supply and installation of HT TOD meter-Class 0.2S, 11KV/110V,-/5A,3-Phase 4 wire conforming to KSEB guidelines
OD79017/2023-2024:Supply of cable termination box motors of suitable size for each motors
OD79016/2023-2024:Supply and installation of 5 HP vaccum pump set with necessary starter
OD79026/2023-2024: Supply and erection of Perforated Galvanised cable tray with suitable mounting achour fastners & mounting accessories as required confirming with all neccessary accessories
OD79027/2023-2024:Supply all materials and Fabrication and erection of supports fabricated out of MS angles C Channel and M S flats of adequate size for erection of panel boards, other necessary equipments etc The supports shall be painted with 2 coats of zinc chromate primer and 2 coats of enamel paint.
OD79033/2023-2024:Preparation of all drawings submitting and getting scheme approval from Electrical Inspectorate, submitting of completion certificate, arranging inspection, getting energisation sanction from Electrical Inspectorate and obtaining permanent power allocation & power connection from KSEBL. (Excluding statutory and sundry charges
OD79035/2023-2024:Preparation of all files ,submission of completion certificate, arranging inspection, getting energisation sanction from Electrical Inspectorate (Excluding statutory and sundry charges)
OD79034/2023-2024:Preparation of all documents and obtaining permanent power allocation & power connection from KSEBL. (Excluding statutory and sundry charges)
Appendix-B- Electromechanical work for Sump at Muthukulam
OD79389/2023-2024:Design, Supply and erection of centrifugal pump set with the following specification,1.Pump -Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete. The duty condition is as follows.- Discharge 127 LPS Speed up to 1500RPM,Total Head 50 m, Positive Suction, Length of suction pipe 2 m, size of pumping main 600mm dia<br>pipe.Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given Modification may done for mono block pump set.
OD79385/2023-2024:Design, Supply and erection of centrifugal pump set with the following specification,1.Pump -Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete. The duty condition is as follows.- Discharge 38 LPS Speed up to 1500RPM,Total Head 24 m, Positive Suction, Length of suction pipe 2 m, size of pumping main 600mm dia<br>pipe. Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given Modification may done for mono block pump set.
OD79384/2023-2024:Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction<br>motor suitable for the above pump working 3 phase 50Hz AC supply, working voltage 415 V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. Complete for 415 V motors digital motor protection relay shall be included in starter as per per IE rules. Flexible coupling shall be used for coupling of pumps and motors.
OD79383/2023-2024:Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. Complete for 415V motors digital motor protection relay shall be included in starter as per per IE rules. Flexible coupling shall be used for coupling of pumps and motors.
OD78873/2023-2024:Supply Installation, testing and commissioning of 400KVA Unitised substation consisting of the following,11KV,high voltage panel board comprising of KSEB metering facilities with CT and PT,1No. Load break switch of 350 MVA capacity, Bus bar sections 350Amps capacity,3 Nos HT HRC fuses and with 230V shunt top coil. With copper winding, having a continuous rating for,11KV/433V 3 phase 50Hz.Vector group Dyn-11.USS should have cable end box on HV side suitable for 3Cx150Sq.mm XLPE cable and suitable end box for connecting 32Rx3.5Cx185Sq.mm Aluminium XLPE cable on LV side, with all fittings and accessories, complete as required as per KSEI specifications.
OD78879/2023-2024:Supplying, laying and clamping of XLPE insulated AL HT armoured power cable, conductors of best conductivity aluminium 11KV grade of 3x300 sqmm XLPE cable in the existing cable tray / existing trench (excluding sand cushioning and protective covering) / clipping directly on wall / ceiling
OD78880/2023-2024:Supplying all material (Termination kit) and providing indoor / outdoor end termination for existing XLPE insulated AL conductor HT power cable of the following size to the transformer HT terminal as per IS 1255. Including properly cleaning, aligning and providing mechnical support to the cable, inspection for any defects etc.
OD78889/2023-2024:Supply and installation of following Current transformer with enclosure for Neutral CT for 400KVA Transformer
OD78909/2023-2024:Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board made out of 16SWG thick CRCA sheet fully compartmentalized, duly rust inhibited, degreasing, zinc phosphating and painted with epoxy paints of approved color and quality, complete with hinged and earthed front doors , name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel, all connections and inter-connections including mounting the following switch gears. (the panel shall be fabricated by a CPRI approved vendor)
OD78911/2023-2024:Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board made out of 16SWG thick CRCA sheet fully compartmentalized, duly rust inhibited, degreasing, zinc phosphating and painted with epoxy paints of approved color and quality, complete with hinged and earthed front doors , name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel, all connections and inter-connections including mounting the following switch gears. (the panel shall be fabricated by a CPRI approved vendor)
OD78913/2023-2024:Supplying, laying and clamping of 3.5x185sqmm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling
OD78914/2023-2024:Supplying, laying and clamping of 3.5x240 sqmm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling
OD78923/2023-2024:Supplying, laying and clamping of 3x120 sqmm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling- 3x120 sqmm
OD78922/2023-2024:Supplying, laying and clamping of 3.5x70 sqmm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-3.5x70 sqmm
OD78921/2023-2024:Supplying, laying and clamping of 3.5x35 sqmm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-3.5x35 sqmm
OD78920/2023-2024:Supplying, laying and clamping of 4x16 sq.mm XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling
OD78930/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling-3x16 sqmm cu ar cable
OD78919/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-4x1.5 sq.mm copper cable
OD78918/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-2x1.5 sq.mm copper cable
OD78917/2023-2024:Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling-1c x 95 sqmm copper flexible cable
OD78942/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x240sqmm
OD78941/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x185sqmm
OD78940/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3x120 sqmm
OD78939/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x70 sqmm
OD78938/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5x35 sqmm
OD78937/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 4x16 sq.mm
OD78936/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 3x16 sqmm cu ar cable
OD78935/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 4x1.5 sq.mm copper cable
OD78949/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 2x1.5 sq.mm copper cable
OD78948/2023-2024:Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required 1c x 95 sqmm copper flexible cable
OD78969/2023-2024:Supply and providing ISI plate earthing as per IS: 3043 with 1200x1200x12mm CI earth plate with Cu strip extending to the other end of the earth plate and bolt to the plate with minimum 3 nos. of SS bolts, filling earth enhancing mineral compount of approved type around earth plate upto a distance of 15cm. with cover
OD78973/2023-2024:Supply and laying Copper strip /GI strip of the following sizes laid 0.6m below ground level excluding excavating trench of suitable size/tray and refilling etc as required 25x6mm Copper strip
OD78972/2023-2024:Supply and laying Copper strip /GI strip of the following sizes laid 0.6m below ground level excluding excavating trench of suitable size/tray and refilling etc as required 25x3mm Copper strip
OD78971/2023-2024:Fixing of 32x6 mm Cu Earth clamp (Main Earth Terminal / Earth bus) with all provision for making protective earthing system and equipotential bonding
OD78970/2023-2024:Supply and drawing bare copper conductors of the following sizes along with wiring/ cables and giving connections as required
OD78990/2023-2024:Supply and installation of 3 phase double cover MCB vertical DB IP42/43 including copper busbar, neutral link and DIN bar suitable for fixing outgoing MCB, flush mount on wall, including cutting holes on the wall making good the damage etc. as required .
OD78989/2023-2024:Supply and installation of double cover enclosure of MCB DB IP42/43 for 1phase inclusive of copper/brass bus bar, neutral link and DIN bar suitable for incorporating MCB, isolator etc, flush mount on the wall including cutting holes on wall,making good the damages etc. as required
OD78988/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 100A TP MCCB
OD78987/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 63/40A FP Isolator
OD78986/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 40A TP MCB
OD78985/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 32A TP MCB
OD78984/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 16A TP MCB
OD78983/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 6A-32A SP MCB
OD78982/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 63A100mA FP RCCB
OD78981/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 40A 30mA DP RCCB
OD78980/2023-2024:Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete. 40A 2P Isolator
OD78979/2023-2024:Supply Fixing of medium grade rigid PVC conduit, open or concealed as required in circuit wiring etc
OD78978/2023-2024:Supply all material and wiring for light / fan point (Primary or first point of group control lights) using 3 runs 1.5 sqmm FR PVC insulated copper wire, modular switches, front plate, MS Box, wiring connector, flexible connection using 2/3 core flexible round cables etc.,. 2 way controlled points shall counted as 2 points.
OD78977/2023-2024:Wiring for Secondary light points (looping) using 2 runs 1.5 sqmm FR PVC insulated copper wire or 1.5sqmm 3 core flexible weather proof cable.
OD78993/2023-2024:Wiring for 6A plug points in combined position using 3 runs1.5 sqmm FR PVC insulated copper wire including supply and fixing of 6A / 3 pin modular plug socket, switches and giving connections. (circuit from same switch board)
OD78992/2023-2024:Supply all materials and wiring for 6A/16A plug points in independent position using 2 runs 2.5 sqmm + 1 run 1.5 sqmm FR PVC insulated including supply and fixing of MS box, 6A / 16A 3 pin modular socket, switch, front plate, conduiting and giving connections.(with out circuit wiring)
OD79022/2023-2024:Supply and drawing PVC FRLS insulated copper wire of following size through existing conduit and giving necessary connections etc as required in the following runs.
OD79023/2023-2024:Supply and drawing PVC FRLS insulated copper wire of following size through existing conduit and giving necessary connections etc as required in the following runs.
OD79025/2023-2024:Supply Installation, testing and commissioning of the following items including cutting holes for recessed fittings, fixing anchor bolt for fan clamps etc. complete.(supply of lights in client scope)
OD79024/2023-2024:Supply Installation, testing and commissioning of the following items including cutting holes for recessed fittings, fixing anchor bolt for fan clamps etc. complete.(supply of lights in client scope)
OD79032/2023-2024:Supply of 11kV grade rubber gloves
OD79031/2023-2024:Providing MV voltage danger notice board 200mmx150mm
OD79030/2023-2024:Providing high voltage danger notice board 300mmx200mm
OD79029/2023-2024:Supply & fixing Laminated drawings of electrical lay out and schematic drawing, shock treatment chart etc on good frame work.
OD79028/2023-2024:Supply & installation of following electrical grade rubber mat conforming to IS standards
OD79036/2023-2024:Supply & installation of following electrical grade rubber mat conforming to IS standards
OD79042/2023-2024:Supply and installation of emergency push button
OD79041/2023-2024:Charges for testing CT PT unit and TOD meter at TMR and recollecting the same after testing (professional charges only )
OD79040/2023-2024:Charges for testing EFR,neutral CT,other relays at meter testing and standards laboratory and obtaining certificate excluding statutory and sundry charges
OD79039/2023-2024:Charges for supply and installation of HT TOD meter-Class 0.2S, 11KV/110V,-/5A,3-Phase 4 wire conforming to KSEB guidelines
OD79038/2023-2024:Supply of cable termination box motors of suitable size for each motors
OD79037/2023-2024:Supply and installation of 1 HP vaccum pump set with necessary starter
OD79045/2023-2024:Supply and erection of Perforated Galvanised cable tray with suitable mounting achour fastners & mounting accessories as required confirming with all neccessary accessories
OD79044/2023-2024:Supply all materials and Fabrication and erection of supports fabricated out of MS angles C Channel and M S flats of adequate size for erection of panel boards, other necessary equipments etc The supports shall be painted with 2 coats of zinc chromate primer and 2 coats of enamel paint.
OD79048/2023-2024:Preparation of all drawings submitting and getting scheme approval from Electrical Inspectorate, submitting of completion certificate, arranging inspection, getting energisation sanction from electrical Inspectorate and obtaining permanent power allocation & power connection from KSEBL. (Excluding statutory and sundry charges)
OD79047/2023-2024:Preparation of all files ,submission of completion certificate, arranging inspection, getting energisation sanction from Electrical Inspectorate (Excluding statutory and sundry charges)
OD79046/2023-2024:Preparation of all documents and obtaining permanent power allocation & power connection from KSEBL.(Excluding statutory and sundry charges)
Bidder Name
Horizia Construction(india)pvt ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .