Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 CrAccepted-AOC NOT AVAILABLE | ₹28.7 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹31.5 CrRejected-Finance VILL FAZALPUR BEHIND FOCAL POINT NEAR RANDHAWA MASADAN JALANDHAR | JALANDHAR | JALANDHAR | PUNJAB | ₹31.5 Cr | L2 | Rejected-Finance Reject |
| 3 | L3₹34.4 CrRejected-Finance | ₹34.4 Cr | L3 | Rejected-Finance Reject |
Tender Value
Refer Docs
EMD Value
₹58.2 L
Closing Date
22 Feb 2023, 3:00 pmClosed
Executive Engineer, JSV, Division Thural
Executive Engineer, JSV, Division Thural
Providing Irrigation Facility under HP SHIVA Project for Baijnath, Bhawarna Lambagoan Sullah and Panchrukhi Blocks District Kangra Himachal Pradesh Package 09
2023_HPIPH_67259_1
EE/JSV/THL/NIT/2022-23 -20484-20530
Open Tender
Civil Works
548 days
Thural
Please refer Tender documents.
8 documents required · 8 mandatory
₹10,000
EXECUTIVE ENGINEER JSV DIVISION THURAL
₹58.2 L
Chief Engineer JSV Dharamshala Zone
7 Aug 2023
18 Jan 2023
22 Feb 2023
18 Jan 2023
22 Feb 2023
11 Feb 2023
30 Jan 2023
Amount
Civil Work
RCC Check Dam : Designing, Constructing, Testing & Commissioning ( to be approved by the competent authority) and Construction of RCC Check Dam as per drawings complete in all respects to the entire satisfaction of the Engineer-in-charge. The contractor shall provide 6 sets of approved drawing and design with one soft copy to the department.for the following size-
35 meter length and 4.5 meter depth with Moutanble Type Intake well arragement at LIS Kudail
35 meter length and 4.5 meter depth with Moutanble Type Intake well arragement at LIS Ghar, LIS Ludhran 1&2 and Chartkhola, LIS Agozar
20 meter length and 3.5 meter depth with Moutanble Type Intake well arragement at LIS Ladoh 2
RCC Intake Structure :- Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) of RCC intake Structure as per drawings, having RCC structure, Roofing with RCC slab, allied electrication work including lighting fixtures, fans, street / area lighting using poles, associated wiring/ cabling ,MCB DBs,receptacle system & accessories etc., Walk way/ passage CI Rungs inside the structure from top to bottom and steel stair case from ground level to top of intake with connecting path having suitable capacity crane/ hoist arrangement for handling of pumping machinery complete in all respects to the entire satisfaction of the Engineer-in-charge. at LIS Manghota(Baijnath Block) and LIS Rajot (Panchrukhi Block) Refer Data Sheet No-1
RCC Intake Structure :- Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) of RCC intake Structure as per drawings, having RCC structure, Roofing with RCC slab, allied electrication work including lighting fixtures, fans, street / area lighting using poles, associated wiring/ cabling ,MCB DBs,receptacle system & accessories etc., Walk way/ passage CI Rungs inside the structure from top to bottom and steel stair case from ground level to top of intake with connecting path having suitable capacity crane/ hoist arrangement for handling of pumping machinery complete in all respects to the entire satisfaction of the Engineer-in-charge. At LIS Malahu 1&2, LIS Thandol Bhawarna and LIS Sidhpur Refer Data Sheet No-1
RCC Intake Structure :- Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) of RCC intake Structure as per drawings, having RCC structure, Roofing with RCC slab, allied electrication work including lighting fixtures, fans, street / area lighting using poles, associated wiring/ cabling ,MCB DBs,receptacle system & accessories etc., Walk way/ passage CI Rungs inside the structure from top to bottom and steel stair case from ground level to top of intake with connecting path having suitable capacity crane/ hoist arrangement for handling of pumping machinery complete in all respects to the entire satisfaction of the Engineer-in-charge. At LIS Dheera 1&2, LIS Dheera 3, LIS Chainchadi Kuthera, LIS Purba and LIS Gaggal Khas( Sullah Block) Refer Data Sheet No-1
RCC Intake Structure :- Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) of RCC intake Structure as per drawings, having RCC structure, Roofing with RCC slab, allied electrication work including lighting fixtures, fans, street / area lighting using poles, associated wiring/ cabling ,MCB DBs,receptacle system & accessories etc., Walk way/ passage CI Rungs inside the structure from top to bottom and steel stair case from ground level to top of intake with connecting path having suitable capacity crane/ hoist arrangement for handling of pumping machinery complete in all respects to the entire satisfaction of the Engineer-in-charge. Baijnath Block . Refer Data Sheet No-1 at LIS Langhu-1,2&3
Tube Well :- Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) of Tube Well as per drawings including allied electrication work including lighting fixtures, fans, street / area lighting using poles, associated wiring/ cabling, MCB DBs & switchboards, receptacle system & accessories etc., mono rail with chain pulley arrangement of suitable capacity for lowering/ lifting the pumping machinery complete in all respects to the entire satisfaction of the Engineer-in-charge.
60 m Depth at LIS Trehal, LIS Ladoh 1 (2 tube wells), LIS Molichak, LIS Jandpur
Room: Construction of 6.25 sqm room with 2.7 m height at LIS Ladoh 1
Improvement of Khul including survey, Soil investigation, cutting - Filling including excavation in all types of strata and foundation concrete, all labour and material charges,complete as per entire satisfaction of engineer-charge.At LIS Banuri, LIS Saliana
Complete Weir Work for Khul as per direction and satisfactiion of Engineer in charge at LIS Banuri, LIS Saliana
Percolation well:- Designing, Constructing, Testing & Commissioning ( to be approved by the competent authority) and Construction of Percolation well with 3.00 mtr internal diameter and 9.00 mtr depth ,having RCC Circular structure, Roofing with RCC slab, allied electrication work including lighting fixtures, fans, street / area lighting using poles, associated wiring/ cabling, MCB DBs, receptacles system & accessories etc., Walk way/passage CI Rungs inside the percolation from top to bottom and steel stair case from ground level to top of percolation well with connecting path having suitable capacity crane/ hoist arrangement for handling of pumping machinery complete in all respects to the entire satisfaction of the Engineer-in-charge. Refer Data Sheet No-2 At LIS Thanpal/chambi and LIS Kathla
Infiltration Gallery:- Designing, Constructing, Testing & Commissioning ( to be approved by the competent authority) and Construction of Infiltration Gallery with 12.0 mtr Length and 2.40 mtr breadth ,having RCC structure, Roofing with RCC slab, allied electrication work including lighting fixtures, fans, street / area lighting using poles, associated wiring/ cabling, MCB DBs, receptacles system & accessories etc., Walk way/passage CI Rungs inside the percolation from top to bottom and steel stair case from ground level to top of percolation well with connecting path having suitable capacity crane/ hoist arrangement for handling of pumping machinery complete in all respects to the entire satisfaction of the Engineer-in-charge. At LIS Chandar
PUMP HOUSE:- Designing, Constructing, Testing & Commissioning of Pump House & Chowkidar Room at following locations including all allied Civil Works, Electrical Works including lighting fixtures, fans, street / area lighting using poles, associated cabling/ wiring, MCB DBs, receptacle system & accessories etc., Sanitary Work, Site Development, Cutting/ Excavation in all kinds of soils, c/o PCC/ RCC Retaining walls, Breast walls, Toilets, Septic Tanks, External Solar powered Street lighting, External landscaping, Fire Fighting arrangement, Building Lightning Protection System (where applicable), Gantry Crane, dewatering etc complete as directed by engineer in charge The rates quoted by the contractor shall be for the complete work. All ancillary works and accessories required to make the system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account. Refer Data Sheet No-3
Pump house of 35.00 Sqm. Area At LIS Binwa Khad(Langhu 1.2 &3 Clusters), LIS Kudail, LIS Manghota
Pump house of 35.00 Sqm. Area At LIS Ghar, LIS Malahu 1&2, LIS Thandol, LIS Ludhran 1&2 and Chartkhola, LIS Sidhpur
Pump house of 35.00 Sqm. Area At LIS Kathla, LIS Thanpal/Chambi, LIS Trehal, LIS Agozar, LIS Rajhot, LIS Ladoh 1, LIS Ladoh 2, LIS Banuri, LIS Saliana, LIS Molichak, LIS Jandpur
Pump house of 35.00 Sqm. Area At LIS Dheera 1&2, LIS Dheera 3, LIS Chainchadi-Kuthera, LIS Purba, LIS Chandar and LIS Gagal Khas
Designing, Constructing, Testing & Commissioning of Desilting tank including civil work, Necessary valves & fittings, tube settler media etc. complete in all respect as per the drawings & technical specification.for the followings size-Refer Data Sheet No-4
11.25 KL Capacity at LIS Manghota
28 KL Capacity at LIS Kudail and LIS Langhu-1,2&3
13.5 KL Capacity at LIS Ghar
24 KL Capacity at LIS Malahu 1&2
28 KL Capacity at LIS Thandol and LIS Ludhran 1&2 and Chartkhola
54 KL Capacity at LIS Sidhpur
6 KL Capacity at LIS Saliana
15 KL Capacity at LIS Ladoh 2
20 KL Capacity at LIS Banuri
28 KL Capacity at LIS Rajot
20 KL Capacity at LIS Dheera 3
28 KL Capacity at LIS Chainchadi Kuthera and LIS Purba
36 KL Capacity at LIS Dheera 1&2
43.75 KL Capacity at LIS Gaggal Khas
63 KL Capacity at LIS Chandar
Designing, Constructing, Testing & Commissioning of Sump well including civil work, Necessary valves & fittings, tube settler media etc. complete in all respect as per the drawings & technical specification.for the followings size-
8.04 KL Capacity at LIS Manghota
22.9 KL Capacity at LIS Kudail
30.2 KL Capacity at LIS Langhu-1,2&3
11.34KL Capacity at LIS Ghar
18.09 KL Capacity at LIS Malahu 1&2
22.90 KL Capacity at LIS Thandol and LIS Ludhran 1&2 and Chartkhola
40.71 KL Capacity at LIS Sidhpur
10.17 KL Capacity (Lambagaon Block)
8.04 KL Capacity at LIS Ladoh 2
10.17 KL Capacity at LIS Agozar and LIS Saliana
11.34 KL Capacity at LIS Trehal, LIS Banuri, LIS Jandpur and LIS Ladoh 1
22.90 KL Capacity at LIS Rajot
13.85 KL Capacity at LIS Chainchadi Kuthera
15.2 KL Capacity at LIS Dheera 3
21.23 KL Capacity at LIS Purba
32.17 KL Capacity at LIS Dheera 1&2 and LIS Gaggal Khas
50.26 KL Capacity at LIS Chandar
Excavation in foundation, trenches (for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts Excluding restoration metalled surfaces to its original condition( Will be paid Separately) & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-charge.
Baijnath Block
Lambagaon Block
Bhawarna Block
Sullah Block
Panchrukhi Block
Providing ,Laying,jointing & testing of Galvanised Mild steel tube with flange / Butt welding of approved make or by JSV Deptt (list attached) conforming to BIS 1239-2004 ( with upto date ammendements ) of following diameter and class including all specials and fittings as required complete as per actual site condition with in all leads and lifts as per the direction and to the entire satisfaction of Engineer-in Charge. The pipe shall be factory galvanized as per IS: 4736-1986 (with up to date ammendements) .
80 mm dia (Medium Class) Baijnath Block
80 mm dia (Medium Class) Bhawarna Block
80 mm dia (Medium Class) Lambagaon Block
80 mm dia (Medium Class) Panchrukhi Block
80 mm dia (Medium Class) Sullah Block
100 mm dia (Medium Class) Baijnath Block
100 mm dia (Medium Class) Bhawarna Block
100 mm dia (Medium Class) Panchrukhi Block
100 mm dia (Medium Class) Sullah Block
Providing ,Laying,jointing & testing of Galvanised Mild steel tube with flange / Butt welding of approved make or by JSV Deptt (list attached) conforming to BIS 1239-2004 ( with upto date ammendements ) of following diameter and class including all specials and fittings as required complete as per actual site condition with in all leads and lifts as per the direction and to the entire satisfaction of Engineer-in Charge. The pipe shall be factory galvanized as per IS: 4736-1986 (with up to date ammendements) .
150 mm dia (Medium Class) Sullah Block
Providing and fixing double flanged cast iron sluice valve of following dia of approved make of JSV to gravity main confirming to BIS: 780-1984 Class PN 1.00 having seat pressureof 10.20 Kg/cm² with M.SFlanges of table -5 with up to date ammendements.
80 mm dia Baijnath Block
80 mm dia Bhawarna Block
80 mm dia Lambagaon Block
80 mm dia Panchrukhi Block
100 mm dia Panchrukhi Block
80 mm dia Sullah Block
100 mm dia Sullah Block
150 mm dia Sullah Block
Providing and fixing screwed/flanged CI air valve (Single/double ball type) of approved make of JSV conforming to BIS-1452-1990 with upto date ammendments as per class PN-1.0 withstanding a seat pressure 15 Kg/cm2 in rising main within all leads and lifts.
25 mm dia Baijnath Block
25 mm dia Bhawarna Block
50 mm dia Lambagaon Block
50 mm dia Panchrukhi Block
50 mm dia Sullah Block
Providing and fixing double flanged cast iron Scour valve of following dia of approved make of JSV to gravity main confirming to BIS: 780-1984 Class PN 1.00 having seat pressureof 10.20 Kg/cm² with M.SFlanges of table -5 with up to date ammendements.
80 mm dia Lambagaon Block
80 mm dia Panchrukhi Block
80 mm dia Sullah Block
Construction of Anchor Block at every in CC 1:1.5:3 (1 cement :1.5 sand :3 graded stone add 20 mm NS) i/c cost of Excavation , form work , C.C work, and reinforcement & curing complete of tentative size 1.50m x 1.50m x 2.00m to provide support to rising main pipe after every 50 m length complete as per direction and to the entire satisfaction of Engineer -in-Charge with in all leads and lifts. (The RD wise structural design shall got approved from the competent autrhority prior to construction of Thrust/Anchor blocks)
Baijnath Block
Bhawarna Block
Lambagaon Block
Panchrukhi Block
Sullah Block
Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) RCC Circular under ground/partial under ground storage reservoirs as per capacity given below at various stages/sites including excavation in foundation in all kinds of soil. including PCC (1:3:6) in foundation and M:30 design mix in bottom slab/raft ,walls and beams. And RCC (1:1.5:3) in roof slab/dome with provision of inspection path around the dome with all alied Civil Works such as c/o chamber for valves, refilling and disposing of surplus excavated earth with in all leads and lifts. The job also includes providing lowering, laying, erecting, hoisting and jointing of pipe assembly for inlet, outlet, overflow and scour pipe with bye pass arrangement consisting of GI / MS pipes special and valves of required classes and dia and all other accessories required such as MS ladders inside and outside, CI cowl type ventilator, SFRC manhole covers with frames of heavy duty with proper locking arrangement, water level indicator. The tanks shall be hydraulically tested for water tightness, All works shall be conforming to relevant IS code. The cost of valves, be included in the rates of tanks .complete in all respects to the entire satisfaction of the Engineer-in-charge. Refer Data Sheet No-5
200 KL Capacity (Baijnath Block)
150 KL Capacity (Baijnath Block)
300 KL Capacity (Baijnath Block)
200 KL Capacity (Bhawarna Block)
250 KL Capacity (Bhawarna Block)
300 KL Capacity (Bhawarna Block)
100 KL Capacity (Lambagaon Block)
200 KL Capacity (Lambagaon Block)
300 KL Capacity (Lambagaon Block)
100 KL Capacity (panchrukhi Block)
150 KL Capacity (Panchrukhi Block)
200 KL Capacity (Panchrukhi Block)
200 KL Capacity (Sullah Block)
250 KL Capacity (Sullah Block)
300 KL Capacity (Sullah Block)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Baijnath Block
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Bhawarna Block
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Lambagaon Block
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Panchrukhi Block
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Sullah Block
Pumping Machinery
SUBMERSIBLE PUMP SETS- Supply Installation Testing & Commissioning of submersible pumping set of KSB/ Crompton/ Kirloskar/ BS/ Calama make conforming to latest relevant BIS Code 8034:1976. The impeller of pump shall be directly mounted on extended submersible squirrel cage motor shaft conforming to BIS 9283-1979 with up to date amendments, totally dust and weather proof with detach able pump casing for easy inspection with double mechanical seal, grease/ oil lubricated bearings and provided with stainless steel thrust bearing plate to withstand vertical loads with minimum wear and tear, It should be fitted with device to take up expansion of water on heating of motor & suitable for operation on 415V ± 10%, 3 Phase 50 Hz AC supply. The pump motor shall be VFD duty and its power should be at least 10% in excess of maximum power required by the pump in complete operating range with mounting stand/ duck foot bend, steel guide wire with mounting hook, lowering chain and standard accessories as supplied by the manufacturers complete, suitable for fulfilling the following requirements:- including Pump sets (working ), necessary piping, electro-mechanical flowmeter and control valves along with electrical works including indoor & outdoor HT/LT switchboards/ PCC, Soft Starter Cubicle(VFD) with suitable bypass arrangement, HT/LT Cabling system complete with end terminations, cable trays & accessories, Earthing system with maintenance free earth electrodes, 415/ 230V small power distribution boards, local push button stations, Junction Boxes, Power/ Welding receptacles and its associated wiring/ cabling etc.,as per requirement of pumping machinery; complete work inclusive of all taxes, insurance, transportation, freight charges, inspection charges, loading, unloading, conveyance to Departmental stores/ site, stacking, etc. including specials and wastage etc.; complete as per Tender Specifications, technical data Sheets and instruction of Engineer in charge.
For Tube well at Trehal LIS i) Rated Voltage :- 415V ± 10% ii) Characteristics of water:- a) Under Ground Water) Temperature- 20 °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, iii) Discharge at Duty Point= 3 LPS iv) Static Head in meters- 18 mts. vii) Duty/Total head in Mts= 25 mts viii) Length of R/Main 34.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of total head at duty point xii) HP of motor / Drive unit - Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2, 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. 1 sets of 3 LPS each with 25 m head
For Tube well at Jandpur LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Under Ground Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 3.12 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 21 mts viii) Length of R/Main 31.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .1 sets of 2.57 LPS each with 21 m head
For Tube well at Ladoh-1 LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Under Ground Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 3.15 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 21 mts viii) Length of R/Main 31.00mts ix) Dia of R/Main=100 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets of 3.15 LPS each with 21 m head
For Tube well at Molichak LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Under Ground Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 2.25 LPS vi) Static Head in meters _28 mts. vii) Duty/Total head in Mts= 33 mts viii) Length of R/Main 31.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .1 sets of 2.25 LPS each with 33 m head
SUBMERSIBLE PUMP SETS- Supply Installation Testing & Commissioning of submersible pumping set of KSB/ Crompton/ Kirloskar/ BS/ Calama make conforming to latest relevant BIS Code 8034:1976. The impeller of pump shall be directly mounted on extended submersible squirrel cage motor shaft conforming to BIS 9283-1979 with up to date amendments, totally dust and weather proof with detach able pump casing for easy inspection with double mechanical seal, grease/ oil lubricated bearings and provided with stainless steel thrust bearing plate to withstand vertical loads with minimum wear and tear, It should be fitted with device to take up expansion of water on heating of motor & suitable for operation on 415V ± 10%, 3 Phase 50 Hz AC supply. The pump motor shall be VFD duty and its power should be at least 10% in excess of maximum power required by the pump in complete operating range with mounting stand/ duck foot bend, steel guide wire with mounting hook, lowering chain and standard accessories as supplied by the manufacturers complete, suitable for fulfilling the following requirements:- including Pump sets (working ), necessary piping, eletro-mechanical flow meter and control valves along with electrical works including indoor & outdoor HT/LT switchboards/ PCC, Soft Starter Cubicle(VFD) with suitable bypass arrangement, HT/LT Cabling system complete with end terminations, cable trays & accessories, Earthing system with maintenance free earth electrodes, 415/ 230V small power distribution boards, local push button stations, Junction Boxes, Power/ Welding receptacles and its associated wiring/ cabling etc.,as per requirement of pumping machinery; complete work inclusive of all taxes, insurance, transportation, freight charges, inspection charges, loading, unloading, conveyance to Departmental stores/ site, stacking, etc. including specials and wastage etc.; complete as per Tender Specifications, technical data Sheets and instruction of Engineer in charge.
From Clear water tank to cluster tank at Langhu-1 & 2 & Upper Bhet LIS i)Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Clear Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 3.08 LPS vi) Static Head in meters _33 mts. vii) Duty/Total head in Mts= 40 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=40 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 3.08 LPS each with 40 m head
From Clear water tank to cluster tank at Jangal LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Clear Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 3.34 LPS vi) Static Head in meters _14 mts. vii) Duty/Total head in Mts= 20 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 3.34 LPS each with 20 m head
From Intake Well to Desilting tank at Langhu-1 & 2 & Upper Bhet LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 7.99 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 22 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=100 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 7.99 LPS each with 22 m head
From Intake Well to Desilting tank at Malahu 1 & 2 LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 5.03 LPS vi) Static Head in meters _28 mts. vii) Duty/Total head in Mts= 33 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 5.03 LPS each with 33 m head
From Intake Well to Desilting tank at Sidpur Sarkari LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 11 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 21 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=150 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 11 LPS each with 21 m head
From Intake Well to Desilting tank at Dheera 1 & 2 LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 8.58 LPS vi) Static Head in meters _13 mts. vii) Duty/Total head in Mts= 20 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=100 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 8.58 LPS each with 20 m head
From Intake Well to Desilting tank at Dheera 3 LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 3.95 LPS vi) Static Head in meters _20 mts. vii) Duty/Total head in Mts= 28 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 3.95 LPS each with 28 m head
From Infiltration Gallary to Desilting tank at Chandar LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 13.38 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 21 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=150 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 13.38 LPS each with 21 m head
From Intake Well to Desilting tank at Chainchadi- Kuthera LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 3.72 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 21 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 3.72 LPS each with 21 m head
From Intake Well to Desilting tank at Pudba LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 5.61 LPS vi) Static Head in meters _28 mts. vii) Duty/Total head in Mts= 35 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=100 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 5.61 LPS each with 35 m head
From Intake Well to Desilting tank at Rajot LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 6.31 LPS vi) Static Head in meters _20 mts. vii) Duty/Total head in Mts= 26 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=100 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 6.31 LPS each with 26 m head
From P. Well to Desilting tank at Kathala LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 2.77 LPS vi) Static Head in meters _16 mts. vii) Duty/Total head in Mts= 22 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 2.77 LPS each with 22 m head
From P. Well to Desilting tank at Thanpal LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 3.05 LPS vi) Static Head in meters _42 mts. vii) Duty/Total head in Mts= 50 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 3.05 LPS each with 50 m head
From Intake Well to Desilting tank at Ganggal Khas LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 8.58 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 21 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=100 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 8.58 LPS each with 21 m head
From Check dam to Desilting tank at Kudail LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 6.07 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 21 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 6.07 LPS each with 21 m head
From Intake well to Desilting tank at Manghota LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 2.15 LPS vi) Static Head in meters _28 mts. vii) Duty/Total head in Mts= 34 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 2.15 LPS each with 34 m head
From Check dam to Desilting tank at Ghar LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 3 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 20 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 3 LPS each with 20m head
From Intake well to Desilting tank at Thandol LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 6.2 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 21 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=100 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 6.2 LPS each with 21 m head
From Check dam to Desilting tank at Ludhran-1 and 2 & Chartkhola LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 12.34 LPS vi) Static Head in meters _25 mts. vii) Duty/Total head in Mts= 31 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=100 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 12.34 LPS each with 31 m head
From Check dam to Desilting tank at Ladoh-2 LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Raw Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 2.02 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 21 mts viii) Length of R/Main 24.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 2.02 LPS each with 21 m head
For Check dam to desilting tank at Agozar LIS i) Rated Voltage :- 415V ± 10% iii) Characteristics of water:-Under Ground Water) Temperature _20_ °C, b) Turbidity up to 100 NTU, c) pH 6.5 to 8 d ) Total solids :-600mg/litre, v) Discharge at Duty Point= 2.57 LPS vi) Static Head in meters _15 mts. vii) Duty/Total head in Mts= 21 mts viii) Length of R/Main 31.00mts ix) Dia of R/Main=80 mm x) Pumping hours per day- 16 hours xi) Limits of pump operation (-) 15% to (+) 10% of Total head at duty point xii) HP of motor /Drive unit ---, Power absorbed or Required BHP at (-) 15% of Duty head or BHP with margins/multiplying factor at duty point & (+) 10% head , whichever is higher i.e. Up to 2 HP = 1.5 , 2 to 5 HP = 1.4, 5 to 10 HP = 1.3 , 10 to 20 HP = 1.2 , 20 to100 HP = 1.15, Above 100 HP=1.10 xiii) Efficiency at duty point Minimum 60% xiv) R.P.M.of Pumping set -2900, xv) Test Run-24 hours continuously for 7 days. .2 sets (1 as stand by) of 2.57 LPS each with 21 m head
CENTRIFUGAL PUMP SETS- Supply Installation Testing & Commissioning ) of horizontal spindle, horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage star rated centrifugal pump or combination of pumps, of recommended make such as Mather and Platt/KSB/Kirloskar as per BIS 1520-1980 with up to date amendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze, impellers/ priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade 45C8/ EN8 with cast iron casing coupled directly through a flexible coupling on a common MS Base Plate to squirrel cage TEFC Energy efficient motors (Conforming to energy efficiency code IE3 or higher ) of standard make such as Kirloskar / BHEL / CG POWER / Siemens / ABB / Marathon and suitable for operation on 415V ± 10%, 50 Hz., 3 phase AC electric supply. The pump motor shall be VFD duty and its power should be at least +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head. The motor/motors as per IS 12615 : 2011 with up to date amendments. The scope shall also include necessary piping for suction, delivery & common header and eletro-magnetic flowmeter, along with electrical works including indoor & outdoor HT/LT switchboards/ PCC, Soft Starter Cubicle(VFD) with suitable bypass arrangement, HT/LT Cabling system complete with end terminations, cable trays & accessories, Earthing system with maintenance free earth electrodes, 415/ 230V small power distribution boards, local push button stations, Junction Boxes, Power/ Welding receptacles and its associated wiring/ cabling etc. as per requirement of following pumping machinery; Complete work inclusive of all taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to Departmental stores / site, stacking, etc. including specials and wastage etc. It shall include providing and fixing of C.I/C.S Sluice valves of approved make and appropriate class to resist the design pressure and complete as per Tender Specifications and instruction of Engineer in charge.
At Kudail LIS 2 sets (1 as stand by) of 6.07 LPS each with 74 m, 1450 RPM with 16 Hours Pumping
At Langhu-1 & 2 & Upper Bhet LIS 2 sets (1 as stand by) of 7.99 LPS each with 145 m, 1450 RPM with 16 Hours Pumping
At Manghota LIS 2 sets (1 as stand by) of 2.15 LPS each with 42 m, 1450 RPM with 16 Hours Pumping
At Ghar LIS 2 sets (1 as stand by) of 3 LPS each with 60 m, 1450 RPM with 16 Hours Pumping
At Malahu-1 & 2 LIS 2 sets (1 as stand by) of 5.03 LPS each with 190 m, 1450 RPM with 16 Hours Pumping
At Thandol LIS 2 sets (1 as stand by) of 6.20 LPS each with 129 m, 1450 RPM with 16 Hours Pumping
At Ludhran-1 and 2 & Chartkhola LIS 2 sets (1 as stand by) of 6.82 LPS each with 74 m, 1450 RPM with 16 Hours Pumping
At Ludhran-1 and 2 & Chartkhola LIS 2 sets (1 as stand by) of 5.52 LPS each with 149 m, 1450 RPM with 16 Hours Pumping
At Sidpur Sarkari LIS 2 sets (1 as stand by) of 11 LPS each with 171 m, 1450 RPM with 16 Hours Pumping
At Dheera 1 & 2 LIS 2 sets (1 as stand by) of 8.58 LPS each with 96 m, 1450 RPM with 16 Hours Pumping
At Dheera 3 LIS 2 sets (1 as stand by) of 3.95 LPS each with 49 m, 1450 RPM with 16 Hours Pumping
At Chandar LIS 2 sets (1 as stand by) of 13.38 LPS each with 105 m, 1450 RPM with 16 Hours Pumping
At Ganggal Khas LIS 2 sets (1 as stand by) of 8.58 LPS each with 159 m, 1450 RPM with 16 Hours Pumping
At Chainchadi- Kuthera LIS 2 sets (1 as stand by) of 3.72 LPS each with 106 m, 1450 RPM with 16 Hours Pumping
At Pudba LIS 2 sets (1 as stand by) of 5.61 LPS each with 88 m, 1450 RPM with 16 Hours Pumping
At Azohar LIS 2 sets (1 as stand by) of 2.57 LPS each with 40 m, 1450 RPM with 16 Hours Pumping
At Ladoh-2 LIS 2 sets (1 as stand by) of 2.02 LPS each with 31 m, 1450 RPM with 16 Hours Pumping
At Rajot LIS 2 sets (1 as stand by) of 6.31 LPS each with 46 m, 1450 RPM with 16 Hours Pumping
At Banuri LIS 2 sets (1 as stand by) of 2.85 LPS each with 20 m, 1450 RPM with 16 Hours Pumping
At Salina LIS 2 sets (1 as stand by) of 2.68 LPS each with 37 m, 1450 RPM with 16 Hours Pumping
INSTRUMENTATION, CONTROL & AUTOMATION WORK- Supply, installation, testing, integration, programming & commissioning of Instrumentation, Control & Automation system for Lift Irrigation including Level Transmitter with display, Level Indicator, Level Switch, Pressure Transmitter, Gauges, Actuated Valves, Flow Meter, micro PLC based Remote Terminal Unit (RTU) along with panel mounted 10” HMI, UPS, SPD, Instrumentation Cables, Cable Trays, Earthing system etc., necessary gateways with SIM card for remote data communication and all other ancillary works and accessories required to make the system fully functional as per user requirement. Scope includes for 19 new schemes (LIS Binwa Khad, LIS Manghota, LIS Kudail, LIS Ludhran 1&2 and Chartkhola, LIS Sidhpur, LIS Kathla, LIS Thanpal/Chambi, LIS Agozar, LIS Rajot, LIS Ladoh 1, LIS Ladoh 2, LIS Banuri, LIS Saliana, LIS Molichak, LIS Jandpur, LIS Chainchadi-Kuthera, LIS Chandar, LIS Purba and LIS Gagal Khas ) Refer Data Sheet No-6
R.G. INDUSTRIES
Lahoty Buildcon Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid