| 1 | L1₹9.8 LAccepted-AOC | ₹9.8 L | L1 | Accepted-AOC Selected |
| 2 | L2₹10.2 L+₹36,326 (3.69%)Rejected-AOC 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | ₹10.2 L+₹36,326 (3.69%) | L2 | Rejected-AOC Selected |
| 3 | L3₹10.8 L+₹92,296 (9.38%)Rejected-AOC 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | ₹10.8 L+₹92,296 (9.38%) | L3 | Rejected-AOC Selected |
| 4 | L4₹11.4 L+₹1.6 L (15.8%)Rejected-AOC | ₹11.4 L+₹1.6 L (15.8%) | L4 | Rejected-AOC Selected |
Tender Value
₹12.8 L
EMD Value
₹25,522
Closing Date
17 Aug 2019, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Renovation/Repair of newly shifted senior Architect Project office at 6th floor, MSO Building, New Delhi.
2019_PWD_177805_1
151 /EE (E)/PWD DHC and ND/Central /2019-20
Open Tender
Electrical Works
Works
30 days
New Delhi
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹25,522
20 Oct 2020
6 Aug 2019
17 Aug 2019
6 Aug 2019
17 Aug 2019
6 Aug 2019
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Supplying and fixing of following Modular base & cover plate on existing modular metal boxes etc. as required. a) 1 or 2 Module
b) 8 Module
c) 12 Module
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 Ampers & 15/16 Ampers modular socket outlet and 15/16 Ampers modular switch, connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 15/16 Ampers switch
b) 6 pin 15/16 Ampers socket outlet
Supplying and fixing of DP sheet steel enclosure on surface/ recess along with 25/32 Ampers, 240 Volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and drawing of following pair 0.5 mm diameter FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit etc as required. a) 2 Pair
Supplying and drawing of UTP 4 pairs CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit etc as required.
Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) Telephone socket outlet
Supplying and fixing of RJ-45 Cat-6 with shutter 1 module socket outlet on the modular plate and switch box including connection etc as required.
Supplying and fixing of 400 mm sweep size wall mounted fan complete with inbuilt Electronic Regulator, Blade, wire lead with moulded plug top etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 Volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 8 way (4 + 24), Double door
Supplying and fixing of 5 Ampers to 32 Ampers rating, 240/415 Volts, 10 kA, breaking capacity “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Providing and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 150 Ampers, 16 kA breaking capacity ,TPMCCB (ICU= 100% ICS)
Providing and fixing of flexible joint for sprinkler of 1.0 Meter Length having male inlet of 25 mm diameter at one end and female out let of 15 mm diameter at other end together with providing & fixing G.I. Spotter 25 mm diameter, G.I. Nipple 25 mm diameter and Rosetter of stainless steel duly polished for 15 mm diameter sprinkler head etc as required (only UL listed, FM approved).
Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 38W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size) suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with the help of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required including dismantling alongwith credit for worn out luminaries under buy back arrangement. The Total system Lumen of 34W to 38W LED should be 3600 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
Supplying, installation, testing & commissioning of energy efficient 2 TR capacity Split type Air Conditioner unit suitable for operation on 230 Volts, 50Hz, single phase capable of performing Cooling, Dehumidifying, Air Circulating & Filtering complete connection with upto 4 meters length refrigerant copper pipe heavy gauge 2"/8" / 3"/8" & 5/8" covered with minimum 10mm thickness insulation including 3 x 2.5 sq.mm flexible copper conductor wire wrapped in flexible pipe and also providing 25mm diameter PVC drain connection including accessories, fixing on surface with clamp to the nearest drain connection pipe complete with repairing of wall with minor civil work at site etc as required.
Supplying, installation, testing & commissioning of 2 TR capacity Window type Air-Conditioner unit suitable for operation on 230 Volts, 50Hz, single phase capable of performing Cooling, Dehumidifying, Air Circulating & Filtering complete connection including accessories, fixing on window including wooden work (fixing plywood of appropriate size) repairing of wall/window with minor civil work at site etc as required.
Supplying and fixing of Digital display wall mounting type Voltage Stabilizer of following capacity for 2 TR capacity Air-Conditioner complete etc as required. a) 5 KVA(Input -165-280 Volts)(Output195-245 Volts)
Providing & Laying of refrigerant copper piping of size 5/8” & 1/4” diameter from indoor unit to outdoor unit of split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable including 20 mm size of cotton thread ribbed PVC flexible pipe from drip tray of Air Conditioner unit to drain pipe along with necessary support complete etc as required. (Measurement to be done for quantity after 4 meters, which is included in item no -18)
Providing and fixing of 25 mm diameter PVC Heavy duty pipe for sweating water dragged in the existing Air Conditioner’s alongwith Clamp etc. Complete as required
Providing and fixing of heavy duty portable powder coated stand for fixing the outdoor unit on the surface of wall etc. complete as required.
Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on surface etc. complete as required. a) 4 X 25 sq. mm
b) 3.5 X 35 sq. mm
Shaka Electrical (India)
Bajrang Electrical ( India )
Panjwani Electrical Engineers and Consultants
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .