| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹42.7 L Quoted ₹43.8 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹47.9 LRejected-Finance | ₹47.9 L | L2 | Rejected-Finance Other then lowest bidder |
| 3 | L3₹52.7 LRejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹52.7 L | L3 | Rejected-Finance Other then lowest bidder |
| Sl No | Description | Qty | Unit | M/s SK Traders L3 | Dighard Electricals L2 | ARTI CONSTRUCTION L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as specified and directed. | 185 | CUM | 280 ₹51,800 | 290 ₹53,650 | 170 ₹31,450 |
| 2.00 | Returning , filling in trenches, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm in Soft/loose soil complete all as directed. | 125 | CUM | 55 ₹6,875 | 120 ₹15,000 | 45 ₹5,625 |
| 3.00 | Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point in Soft / loose soil complete all as directed. | 60 | CUM | 65 ₹3,900 | 250 ₹15,000 | 54 ₹3,240 |
| 4.00 | Supply and laying dry Sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed.
Note: - Thickness after punning will be measured for payment. | 55 | CUM | 950 ₹52,250 | 1,400 ₹77,000 | 625 ₹34,375 |
| 5.00 | Supply and laying burnt brick old size sub class 'B' laid in trenches a butting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complete all as specified and as directed. | 5.5 | 1000 NOS | 10,000 ₹55,000 | 5,180 ₹28,490 | 7,500 ₹41,250 |
| 6.00 | M & L for taking down underground HT/LT cable of aluminium conductorf up to 300 Sqmm of any core after disconnecting from sheet metal encloser / panel board and taking out from trenches including making good the disturbed surfce complete all as specified and directed. | 650 | RM | 6 ₹3,900 | 10 ₹6,500 | 5 ₹3,250 |
| 7.00 | Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified. | 150 | RM | 325 ₹48,750 | 255 ₹38,250 | 310 ₹46,500 |
| 8.00 | Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified. | 200 | RM | 799 ₹1.6 L | 490 ₹98,000 | 715 ₹1.4 L |
| 9.00 | Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified. | 200 | RM | 595 ₹1.2 L | 399 ₹79,800 | 565 ₹1.1 L |
| 10.00 | Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified. | 150 | RM | 1,250 ₹1.9 L | 700 ₹1.1 L | 1,050 ₹1.6 L |
Updated dates
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Feb 2026, 6:00 pmClosed
Col Manish Dhaka CWE
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
REPAIR AND REPLACEMENT AND MAINTENANCE OF HT ELECTRIC SUPPLY AND ALLIED WORKS AT VSN GANDHINAGAR UNDER GE AF CHILODA
2026_MES_747402_1
82299/CHL/E8
Open Tender
Electrical and Maintenance Works
180 days
Gandhinagar
As per tender document
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹96,000
2 Apr 2026
6 Jan 2026
12 Feb 2026
7 Jan 2026
4 Feb 2026
21 Jan 2026
7 Jan 2026 - 20 Jan 2026
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as specified and directed.
Returning , filling in trenches, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm in Soft/loose soil complete all as directed.
Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point in Soft / loose soil complete all as directed.
Supply and laying dry Sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed. Note: - Thickness after punning will be measured for payment.
Supply and laying burnt brick old size sub class 'B' laid in trenches a butting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complete all as specified and as directed.
M & L for taking down underground HT/LT cable of aluminium conductorf up to 300 Sqmm of any core after disconnecting from sheet metal encloser / panel board and taking out from trenches including making good the disturbed surfce complete all as specified and directed.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 sq mm 3 core complete all as specified.
S&F in repair 40 mm bore galvanised iron tubing light grade with all fittings laying in trenches or in road cross/ floors as protection of cable complete all as specified.
S&Fin repair 50 mm bore galvanised iron tubing light grade with all fittings laying in trenches in road cross/ floors as protection of cable complete all as specified.
S&F in repair 80 mm bore galvanised iron tubing light grade with all fittings laying in trenches in road cross/ floors as protection of cable complete all as specified.
M & L for boring under road/drain by manual method for inserting the light grade pipe GI tubing up to 80 mm dia cable protection all as specified and directed by Engineer In Charge.
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 sqmm 3 core. complete all as specified and as directed by Engineer-in-charge. Note: (a) The fault located equipment shall be brought at site within 02 hours of Instruction to do so received from Engineer-in-charge. (b) If fault machine is not provide by contractor within 02 hours penalty will be imposed at the rate of Rs 2000 per Hrs.
M&L for defect rectification in LT 1.1 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 sqmm 3.5 core. complete all as specified and as directed by Engineer-in-charge. Note: (a) The fault located equipment shall be brought at site within 02 hours of Instruction to do so received from Engineer-in-charge. (b) If fault machine is not provide by contractor within 02 hours penalty will be imposed at the rate of Rs 500 per Hrs.
S&F in repair Cable jointing kit for 11000 volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified.
S&F in repair Cable jointing kit for 11000 volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm 3 core complete all as specified.
S&F in repair Cable jointing kit for 11000 volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm 3 core complete all as specified.
S&F in repair Cable jointing kit for 11000 volts grade cable for Outdoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm 3 core complete all as specified.
S&F in repair Cable jointing kit for 11000 volts grade cable for Outdoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm 3 core complete all as specified.
S&F in repair Cable jointing kit for 11000 volts grade cable for Outdoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified.
S&F in repair Cable jointing kit for 11000 volts grade cable for Indoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified.
S&F in repair Cable jointing kit for 11000 volts grade cable for Indoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm 3 core complete all as specified.
S&F in repair Cable jointing kit for 11000 volts grade cable for Indoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size up 240 sqmm to 300 sqmm 3 core complete all as specified.
S&F in repair Cable jointing kit heat shrink type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 240 to 300 Sqmm 3.5 core complete all as specified.
S&F in repair Cable jointing kit heat shrink type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 150 to 185 Sqmm 3.5 core complete all as specified.
S&F in repair Cable jointing kit heat shrink type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 120 to 150 Sqmm 3.5 core complete all as specified.
S&F in repair Cable jointing kit heat shrink type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 70 to 95 Sqmm 3.5 core complete all as specified.
S&F in repair Cable jointing kit heat shrink type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 35 sqmm to 50 Sqmm 3.5 core complete all as specified.
S&F in repair Cable jointing kit heat shrink type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 16 sqmm to 25 Sqmm 4 core complete all as specified.
M&L for preparation of old painted surface of four pole/two pole structure of steel tubular pole (11 meter long above coping) and applying one coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint , rewriting pole No by painter/digital stickers with making of pole No with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specifeid and directed.
S&F in repair MCCB TP 630 amp Adjustable type 50 KA with terminal connections complete with required size of aluminium lugs etc complete all as specified.
S&F in repair MCCB TP 400 amp Adjustable type 36 KA with terminal connections complete with required size of aluminium lugs etc complete all as specified.
S&F in repair MCCB TP 250 amp Adjustable type 36 KA with terminal connections complete with required size of aluminium lugs etc complete all as specified.
S&F in repair MCCB TP 200 amp Adjustable type 25 KA with terminal connections complete with required size of aluminium lugs etc complete all as specified.
S&F in repair MCCB TP 160 amp Adjustable type 25 KA with terminal connections complete with required size of aluminium lugs etc complete all as specified.
S&F in repair MCCB TP 125 amp fixed type 16 KA with terminal connections complete with required size of aluminium lugs etc complete all as specified.
S&F in repair MCCB TP 100 amp fixed type 16 KA with terminal connections complete with required size of aluminium lugs etc complete all as specified.
S&F in repair MCCB TP 63 amp fixed type 16 KA with terminal connections complete with required size of aluminium lugs etc complete all as specified.
S&F in repair MCB TPN 63A, C Curve with terminal connections complete with required size of aluminium lugs etc complete all as specified.
M & L for comprehensive Maintenance / Servicing of existing VCB, 3 phase, 11 KV, 630 / 400 Amps by authorised manufacturer rep /dealer.The scope of work includes : (a)Calibration of metering system, checking, setting, adjustment of over current relay, earth fault and tripping relay complete all as specified and directed by Engr in charge. (b) Checking of heater mechanism, IR value,14 KV hypo test at site, replacement of locking arrangement & testing for smooth functioning at rated voltage. (c) Making all indicator bulbs and push buttons functional at no additional cost (d) Making all electrical connections to voltmeter and ammeter good and ensure the proper functioning of ammeter and voltmeters with proper caliberation/adjustment of voltage and current of outgoing VCB,s with main Incomer VCB Note: (1) The contractor should ensure the proper functioning of VCB's and should approach with authorised manufacturer rep /dealer for carrying of servicing of breaker periodically & when fault /breakdown occurs. (2) Contractor shall produce all purchase voucher, service report and test certificate before submitting the RAR. (3) The contractor shall be responsible for serviceability of VCB for the entire contract period (4) Unserviceable Spare Part will be paid and measured separately under respective items of schedule. (5) contractor shall arrange the transport to VCB trolly to manufacturer workshop and refix after repair as direction by JE/ Engr-in-Charge. cost for transportation is included in this item. (6) Contractor should arrange parts and make serviceability as per direction of JE/ Engr-in-Charge with in 48 hrs otherwise penalty of Rs 2000 per Hrs imposed..
Supply only 1 Amp PT fuze (set of three fuzes) complete all as specified and directed by Engr in charge.
Supply only tripping coil and close coil for healthy functioning of HT VCB complete all as specified and directed by Engr in charge.
Supply only gear assembly for healthy functioning of HT VCB complete all as specified and directed by Engr in charge.
Supply only raking rack out assembly for healthy functioning of HT VCB complete all as specified and directed by Engr in charge.
S & F Potential transformer for VCB's 11000/110 volt, 3 phase, 50Hz including making all electric connections, testing complete the meters functioning properly all as specified and directed by Engr- In-Charge
M & L for repair and servicing of KWH meters for VCB's including making all electric connections good and making the meters functioning well all as specified and directed by Engr- In-Charge
S&F (power pack) battery backup for VCB 12 Volt, 7 Ah including all electrical connection and testing complete all as specified and directed by Engr in charge.
S&F Motor Charge spring mechanism with all necessary coils suitable for healthy functioning of HT VCB complete all as specified and directed by Engr in charge.
S&F master trip relay for 11 KV for healthy functioning of HT VCB including all electrical connection and testing complete all as specified and directed by Engr in charge.
S&F thermostat 52 degree to 90 degree for healthy functioning of HT VCB including all electrical connection and testing complete all as specified and directed by Engr in charge.
S&F annunciator MLD-02 with hooter for 11 KV HT VCB of maximum short circuit rating 1.8 KA,400 A,250 MVA including all electrical connection and testing complete all as specified and directed by Engr in charge.
Supply only HRC fuse 6 to 10 Amp for 11 KV HT VCB of maximum short circuit rating 1.8 KA,400 A,250 MVA including all electrical connection and testing complete all as specified and directed by Engr in charge.
S&F self power relay for VCB including all electrical connection and testing complete all as specified and directed by Engr in charge.
S&F VCB HT Insulator suitable for 11 KV VCB complete all as specified and directed by Engr-in-charge.
S&F of current transformer for VCB's capacity up to 400/200/5 Amps, 3 phase, as per exising including making all electric connections good and making the meters functioning well all as specified and directed by Engr- In-Charge
M & L for Opening the HT 11 KV, Bus bar chamber of HT panel , cleaning the HT bus bar , inspect the nuts, bolts, bus bar insulator and tighting/replace with new one if required and heating up for removal of moisture , record its IR value with the help of 5 KV megger and applying thick coating of Z931 strippex B and Z955 Strippex (SL) of stanvac product or its equivalent makes as approved by GE for preventing from flush over and fire hazard , including replacement of 3/2 mm thick gasket, closing of all holes and charging the same complete all as directed by Engineering -in- charge .
M & L for disconnecting the existing unserviceable over current and earth fault relay from the VCB Panel and Supply and fixing of new digital microprocessor Base 3 over current +1 earth fault relay including all electrical connection and testing complete all as specified and directed by Engr in charge.
M & L for comprehensive Maintenance / Servicing of existing RMU's, 3 phase, 11 KV, 630 / 400 Amps by authorised dealer only.The scope of work includes :(a)Calibration of metering system, checking, setting, adjustment of over current relay, earth fault and tripping relay complete all as specified and directed by Engr-in-charge.The contractor should immediately approach mechanic of authorised dealer as soon as fault occurs/resetting required. (b) Checking of all incoming and outgoing HT Terminals for any looseness and ensuring the proper tightness for all terminals. (c) Checking the nominsl operating gas presssure as per manufacturer's standard of RMU and testing for any leakage of insulation gas and rectify the same if found (d) Operating gas pressure should be suitable to satisfy the rated dielectric strength (e) Testing for CT's, PT's, Relays , Breakers and cable glands. (f) Anti oxide greasing should be done at all connections of cable and bus bars Note: (1) The contractor should ensure the proper functioning of RMU's and should approach with authorised dealer for carrying of servicing of breaker periodically & also when fault /breakdown occurs. (2) Contractor shall produce all purchase voucher and test certificate before submitting the RAR. Eng-in-Charge shall be ensured the same while processing RAR striclly. (3) The contractor will be responsible for serviceability of RMU's for the entire contract period by authorised dealer only. (4) Unserviceable Spare Part will be paid and measured separately under respective items of schedule.
Supply and fix RMU HT CT up to 200/100/05 Amp as per existing make including all electrical connection and testing complete all as specified and directed by Engr in charge.
Supply only over current relay for RMU 14 S as per sample all as specifed and directed
Supply only indicating lamp for RMU as per sample all as specifed and directed.
supply and fix Hydraulic mechanism for door of RMU Panel including all safety rubber packing complete all as specified and directed by Engr in Charge.
Supply and fix self power relay for RMU including all electrical connections complete all as specified as directed by Engr-in-Charge.
M & L for comphrensive repair and maintenance of Air Circuit Breaker capacity 630/800/1250/1600 Amps by cleaning of interphase barriers, Draw out contacts on the circuit breaker and stationary contacts in the cubicle should be cleaned and inspected for overheating, alignment and broken and weak springs. Coat contact surfaces with contact lubricant to ease mating, ensure lubrication is done according to the manufacturer specification, protective relays and circuit breaker trip devices should be inspected and tested according to manufacturer's specifications including testing complete.
S & F ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps including dismantling of old ACB complete all as specified and as directed Engr-in-Charge.
S & F ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 1600 Amps including dismantling of old ACB complete all as specified and as directed Engr-in-Charge.
M & L for Servicing of transformer 1250/1000/630 KVA at carrying out insulation resistant test(HT-LT,HT-E & LT-E), BDV of Oil (top & bottom sample), checking of oil leakage, Filtration & topping up of oil, test, quaterly resistance check of earth pits, arresting of leakage by proper tightening of terminals& joints,replacement of loose or burnt out gasket nut & bolt, & proper sealing of valves etc as directed by Engineer-in-Charge. Note:- (i)The cost of oil filtration, gasket & new oil will be measured & paid separately. (i) The contractor should produce all testing certificates immediately after testing, .Moreover testing should be carried out by authorized OEM only
M & L for Servicing of transformer 500 /400/315/200/100 KVA at carrying out insulation resistant test(HT-LT,HT-E & LT-E), BDV of Oil (top & bottom sample), checking of oil leakage, Filtration & topping up of oil, test, quaterly resistance check of earth pits, arresting of leakage by proper tightening of terminals& joints,replacement of loose or burnt out gasket nut & bolt, & proper sealing of valves etc as directed by Engineer-in-Charge. Note:- (i)The cost of oil filtration, gasket & new oil will be measured & paid separately. (ii) The contractor should produce all testing certificates immediately after testing, .Moreover testing should be carried out by authorized OEM only
Supply and topping up transformer oil during after filtration and ensure dielectric strength upto 40 KV to 60 KV complete all as specified and directed by Engineer- in charge.
S&F in replacement worn out HT terminal with bush ( brass spindle with caramic bushing) of existing size for transfomers to arrest leakage by openging top cover and refixing the same complete all as specified and directed by Engineer- in charge.
S&F in replacement worn out LT terminal with bush ( brass spindle with caramic bushing) of existing size for transfomers to arrest leakage by openging top cover and refixing the same complete all as specified and directed by Engineer- in charge.
M & L for replacement of unserviceable synthetic rubberized corksheet/gasket of 6mm thick for fixing top cover and HT / LT side transformer bushes of following capacity
S&F in replacement of Silica Jel of excisting transformer complete all as specified and directed by Engineer- in charge.
M & L for rewinding of HT coils with super enameled copper wire / strips DPC / super enameled matching with existing gauge and insulating material of high class as per manufacturer recommendation with packing / insulation material in each layer of winding,Baking the core assembly with the help of oven duly varnshing the coils to improve IR valve and to eliminate moisture and Inserting the core assembly after repair the core and making connection with HT / LT bushing studs & lead extension(replacing studs if damaged) and closing the tank top cover by fixing nuts, bolts and washers (Top cover gasket will be measured and paid for seperately) complete all as specified and as directed by Engineer-in-charge.
All as per item No. 79 above but LT coil with copper strips
M&L for replacement of defective tap changer with tapping arrangement -7.5% and +7.5% on normal tapping complete all as specified and as directed by Engineer-in-charge
M&L for replacement of gun metal gate valve with iron wheel head of 25 mm dia screwed both ends heavy duty ISI marked complete incl providing necessary rubber packing to stop leakage complete all as specified and as directed by Engineer-in-charge
M & L for machine spray painting by alkyd paint of the under mentioned plants /machinery by rubbing, scraping of old paints with emery paper, cleaning and preparation of smooth surfaces complete including writing MES/SM No etc. with approved quality paint at different locations , all as directed by Engr in charge for following items .
Transformers of capacity upto 1250/1000/630/500 KVA
Transformers of capacity upto 400/200/100 KVA
LT Distribution Panels and APFC Panels
Repairs maintenance of APFC panel of capacity 90KVAR to 200KVAR including replacement of wiring with copper conductor cable with lugs etc calibration of relay, digital meter including testing complete. Note : M&L for replacement of unserviceable Spare Part will be measured and paid separately under respective items
S&F in repair Red/Yellow/Blue LED indicating lamp (Set of three lamp), 240 volts, AC
S&F in repair cylindrical capacitor capacity 5 KVAR to 50 KVAR , 440 volts, 3 phase, 50 Hz complete all as specified and directed by Engr in Charge.
Supply and fix in repair APFC controller for contactor switching with 1 CT Complete all as specified and directed.
S&F in repair Red luminous push button with LED indicating lamp and 1NC Element complete all as specified and directed by Engr in Charge.
S&F in repair Green luminous push button with LED indicating lamp and 1NC Element complete all as specified and directed by Engr in Charge.
S&F in repair 50 KVAR capacitor duty contactor , 240 volts, AC coil complete all as specified and directed by Engr in Charge.
S&F in repair 40 KVAR capacitor duty contactor , 240 volts, AC coil complete all as specified and directed by Engr in Charge.
S&F in repair 25 KVAR capacitor duty contactor , 240 volts, AC coil complete all as specified and directed by Engr in Charge.
S&F in repair up to 12.5 KVAR capacitor duty contactor , 240 volts, AC coil complete all as specified and directed by Engr in Charge.
S&F in repair digital voltmeter 0-500 volts of size 96x96mm complete all as specified and directed by Engr in Charge.
S&F in repair digital Ampere meter 0-500 volts of size 96x96mm complete all as specified and directed by Engr in Charge.
M & L for Servicing of Servo controlled voltage stabilizer of any capacity including setting of Input and Output voltage complete all as directed. Note:- Spare required for replacement if any will be measured and paid separately.
Supply only Shunt Trip coil of any size
Supply only Cut out PCB,3-phase
Supply only Micro-controller PCB with connector
Supply only control cabling with glass fuse
Supply only Indication lamp, 22.5 mm dia, R - Y- B
Supply only Push button,12.5 dia,R -Y-B
Supply only Single phase , Synchronise AC motor, 10 KG
Supply only RC network for 10 KG motor
Supply only Sensing Transformer for Digital/analog control
Supply only Aluminium Busbar of any size and any capacity.
M & L for rewinding of Stabiliser buck boost transformer/Variable voltage transformer single phase. I/P -0-144 VAC,O/P- 0 -85 VAC with super enameled copper wire / strips DPC / super enameled matching with existing gauge and insulating material of high class as per manufacturer recommendation with packing / insulation material in each layer of winding,
M & L for repairing of LT panel of any size by welding of door replacement of hinges wherever required and re-arrange the internal fitting/fixture including replacing of nut bolt and locking arrangement , replace of door sheet thickness 3.15mm size, bottom plate including cable gland upto size 240 mm cable (1+10) one incomming and upto ten outgoing cables and disconnection of unserviceable internal cables of any size rewiring/reconnection by suitable size of wire/cable including fixing of panel in PCC 1:2:4 type B-2 using 20 mm graded stone aggregate complete including one coat of red oxide primer and one coat smoke gray colour paint all as specified and directed.
S&F in repairs Glow sign board of size 1.5 m x 0.9 m x 0.20 m , made out of 1.0 mm thick tin sheet all side except front side aluminium beading "L" shape at all boarder exterier and interier side, front should be acrylic cover 2.0 mm thick of blue colour and written the subject matter as given by the Engr-in-charge in english capital letter in white colour with twin tubelight fitting 1x 20 watt (2 nos) including all electrical connection with surface conduit wiring 1.5 Sqmm ((length not exceeding 8 meter) copper wire with drilling and necessary required arrangement for fixing of board including testing as all spcified and directed.
M & L for painting of shutters with one coat of synthetic enamal paint, of size 2.5 mtr x 2.5 mtr at E/S Sub stations complete all as specified and directed by E-in- Charge
Supply and fix safety instructions charts from electric shocks and SOP,s for fire fighting all as specified and directed
M & L for chemical Earthing complete with copper earth plate 90 cm x 60 cm x 5 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including copper earth strip of 32X6mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any addition in length shall be adjusted through deviation order.
M & L for replacement of Earthing complete in repairs with galvanised steel earth electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as eGI strip of 32X6mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any addition in length shall be adjusted through deviation order. (ii) necessary excavation wk is included in this item.
Supply and fix in replacement of Aluminiun strip of existing size 32 x 6 mm with saddles and fixing screws etc for earthing connection to bus bar trunking system of existing LT Panels at MAP power stations
M & L for shifting of serviceable transformer 250 KVA from MES store yard / sub-stn (indoor / outdoor) for installation in place of unserviceable transformer and back after replacing with repaired transformer complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation of pole, stays etc. complete.
M&L for PCC PCC 1:2:4 type B-1 with 20 mm graded aggregate for coping of pole including form work complete all as directed.
Supply and fix in replacement of copper strip of existing size 32 x 6 mm with saddles and fixing screws etc for earthing connection to bus bar trunking /panel/DBs etc complete all as specified and directed by Engr in Charge.
S & F Cable route indicator for HT Cable made out of 150 mm round disc of cast iron duly written with HT/LT cable properly fixed with nut bolts to angle iron 40x40x5 mm length 60 cms properly grounted in ground at a depth 25 cms with PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate size 10x10x10 cm underground, incluidng necessary excavation earthwork complete. Angle iron shall be painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete as in repairs all as specified and directed.
Supply, installation, commisioning and testing factory made and tested, CPRI approved, LT feeder pillar box (KISOK), indoor type, mounted on rigid angle iron frame, suitable size, having independent compartment for insulated Aluminium bus bar, incoming feeder and each out going feeder, dust and vermin proof, factory made, fabricated out of not less than 3.00 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminium bus bar of 200 Amp rating for 3 phase and neutal 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set, Cable glands with independent plates at bottom for each out going and in coming cables in cable alley and complete board painted with powder coating in siemens grey colour front & rear opening type with double door shutter and locking arrangement, suitable aprons for cable entry/exist , including cable connection properly with lugs and thimable, complete all as approved and comprising as under: -
Out going :- (a)MCCB 4 Pole, current rating 63 Amp, With Thermal Magnetic release , breaking capacity 16 kA at 415V, 50Hz - 01 No (b) MCB SPN current rating 40 Amp, breaking capacity 10 kA at 230 V, 50Hz - 02 Nos (c) MCB SPN current rating 32 Amp, breaking capacity 10 kA at 230 V, 50Hz - 03 Nos (d) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 50 x 50 x 6 mm thick angle iron duly painted - 01 No. (e) M & L for necessary excavation & earth work and PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete as directed by Eng-in-Charge. - 01 job
Supply, installation, commisioning and testing factory made and tested, CPRI approved, LT feeder pillar box (KISOK), indoor type, mounted on rigid angle iron frame, suitable size, having independent compartment for insulated Aluminium bus bar, incoming feeder and each out going feeder, dust and vermin proof, factory made, fabricated out of not less than 3.00 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminium bus bar of 250 Amp rating for 3 phase and neutal 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set, Cable glands with independent plates at bottom for each out going and in coming cables in cable alley and complete board painted with powder coating in siemens grey colour front & rear opening type with double door shutter and locking arrangement, suitable aprons for cable entry/exist , including cable connection properly with lugs and thimable, complete all as approved and comprising as under: -
Out going :- (a)MCCB 4 Pole, current rating 100 Amp, With Thermal Magnetic release , breaking capacity 16 kA at 415V, 50Hz - 01 No b) MCB SPN current rating 63 Amp, breaking capacity 10 kA at 230 V, 50Hz - 02 Nos c) MCB SPN current rating 32 Amp, breaking capacity 10 kA at 230 V, 50Hz - 03 Nos (d) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 50 x 50 x 6 mm thick angle iron duly painted as directed by Eng-in-Charge. - 01 No. (e) M & L for necessary excavation and as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete as directed by Eng-inCharge. - 01 job
Supply and fix in replacement of onload Change over switch 400 Amps 4 Pole, 415 V AC with sheet metal enclosure including all electrical connections & testing complete all as specified and directed by Engr in charge.
Supply and fix in replacement of Solar panel 5BB 325-525 Wp, including all electrical connections & testing complete all as specified and directed by Engr in charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tender.pdf
Tender Documents • 1.23 MB
BOQ_836966.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid