| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹32.3 L+₹2.1 L (7.03%)Rejected-AOC | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹32.3 L+₹2.2 L (7.29%)Rejected-AOC | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 4 | L4₹33.3 L+₹3.1 L (10.4%)Rejected-AOC | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 5 | L5₹33.4 L+₹3.3 L (10.9%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L5 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
19 Jul 2023, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPL REPAIR AND REWIRING IN BLDG NO T 39 AND PROVN OF STREET LIGHTS AT VARIOUS LOC AT MIL STN DHRNAGADHRA
2023_MES_605053_1
GE(A)/GNR/TOKEN/33 of 2023-24
Open Tender
Civil Works
Item Rate
180 days
MIL STN DHRNAGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹56,000
Yes
31 Aug 2023
22 Jun 2023
21 Jul 2023
22 Jun 2023
19 Jul 2023
7 Jul 2023
22 Jun 2023 - 5 Jul 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for laying under ground cable/pole foundation in hard & dense soil and getting out complete all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in soft/loose soil and getting out complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and exc 1.5 m but n. exc 3.0m in depth for pole foundation in hard & dense soil and getting out completed all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Soft/ disintergrated rock complete all as specified and directed.
M&L for sand cushioning to under ground cable with dry sand ocaly available 8cm thick before laying the cable and 15 cm above the cable, stretching and testing of cable complete all as specified & directed by Engineer-in-Charge. Note : for payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 10.75 of SSR Part-I
Supply and laying sub class burnt bricks as cable protection cover laid perpendicular to trenches complete all as specified and directed.
Removing excvaated soil nexc 50m and depositing where directed at a level n exc 1.5 m above the stating point soil etc completed all as specified and as directed.
M&L PCC 1:4:8 type D-2 (40mm graded aggregate) in foundation, sub base, filling and mass concrete complete all as specified and directed.
M&L for PCC 1.2.4 type B2 using 40mm graded stone agreegate as in Bed block complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed.
M&L Brickwork with subclass‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L Brickwork without subclass‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 (Note - Brick received from demolition shall be used) complete all as specified and directed.
Taking down chowkats or frame of any descrip tion exc 1.5 Sqm each and n.exc 4 Sqm (without taking off shutters from the frames) removing to store complete as specified and directed.
S&F, aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy with length of bolt 300 mm and fixed complete all as specified and directed.
S & F 100 mm long Butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed.
S & F in repairs 4 levers Mild steel Mortice lock, vertical type, size 100 mm complete all as specified and directed.
S&F, 150mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel springcomplete all as specified and directed.
S&F, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to wooden door Shutters/aluminium sliding shutters complete all as specified and directed.
S&F,as in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to wooden door Shutters/aluminium sliding shutters complete all as specified and directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified & directed by Engr-in-charge.
S&F, in repairs, 25mm dia, powder coated, fancy type, aluminium decorative tubular curtain rod with decorative ball type side brackets, complete all as specified and directed.
S&F in repair mild steel bolts purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends. each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long dia of neck n exc 20mm complete all as specified and directed.
S&F for gusset plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk foring hole without any attachement to Fe-290 (Gde E-165) complete all as specified and directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed by Engr-in-charge.
S&F powder coated aluminium window shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified complete all as directed by Engr-in-charge.
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified & directed by Engr-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covenng/cladding to wall, fixed with self tapping screws as specified.
S&F, in repair, false ceiling, at any height, 600 x 600mm grid with Armstrong 'Prelude XL 32' grid system and 16mm thick mineral fibre acoustic tile 'RH - 99 Classic lite' with suspension system complete all as specified and per manufacturer's instruction. Make : Armstrong or equivalent as approved by GE.
M&L, Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set & jointed in net cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete as specified and directed.
M&L, Non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM 1:3 complete all as specified and directed
M&L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as sepcified and directed.
M&L for 15mm thick rendering in two layers, 10mm thick in CM 1. 6 and 5mm thick in CM 1:4 masonry surface or surface other than fair face of brickwork surface finished lair and even without using extra Cement complete all as specified and directed.
M&L for 15mm thick rendering in CM 1. 6 on stone masonry surface or surface other than fair face of brickwork surface finished fair and even without using extra Cement
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for preparing of new plastered or un-plastered surfaces and applylng two coats of oil bound distemper over a coat of primer over and including wall care pulty complete all as specified and directed
M&L for complete removal of existing treatment on old plastered or un- plastered surfaces and applying two coats of oil bond distemper over a coat of primer over 3mm thick Birla/JK white putty, preparatory to distempering on walls complete all as specified and directed .
M&L for two coats of Cement paint over one coat of alkali- resistant priming paint including preparation of new plasterd surfaces of wall .
M&L complete removal of existing treatment of wall and preparation of old plastered or Un plastered surfaces of wall and applying two coats of cement base paint over one coat of alkali- resistant priming paint complete all as specified and directed.
S&F Glazing with sheet, 3mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane.
5.50 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) not exc 0.5 sq.m from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S&F 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq.m in each pane complete all as specified and directed.
Two Coats of Synthetic Enamel Paint over a Coat of redoxide Primer including preparation of surface for steel Surfaces complete all as specified and directed.
M&L for cutting of road/PCC for laying of 40mm dia GI pipe for protection of LT cable and making good to match with the existing using extra cement etc. complete all as specified and directed.
S&F, steel water tubes with rubber gasket at end of each pieces of pipe, light grade, galvanized, with all fittings of size 40mm dia laid in floors/trenches/fixed with poles for protection of cable complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar cement lime mortar including all quoins arches. pillars etc but excluding ashlar facings, dressed stone work and precast oncrete articles complete all as specified and driected.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi corrugated, etc) sheets in roof coverings complete all as specified and directed.
Dismentling ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover filletscomplete all as specified and directed
Taking down carefully copper/aluminum point wiring (light, fan,socket or power) complete,including fixture and fitting such as as switches, ceiling roses, pendants, regulators, sockets,etc excluing light fittings etc,removing materials to store for keeping in safe custudy or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surface of walls, ceiling, floor etc to match with the existing surface complete all as specified and directed.
Taking down carefully old UNSV submain wiring of any type/any size removing material to store for keeping in safe custody or for taking credits and making good the disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :- Make of Cable Polycab/Finolex/Havells
(a) One light/fan point controlled by one switch
(b) One 3 pin, 5 Amps, socket outlet on the same board controlled by another switch.
(c) One multi pin 5 Amps, socket outlet on Independent board.
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 4.0 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
S&F, in repair, lamp holder insulated body with back plate for battern fittings complete all as specified and directed.
S&F, Modular switch 1 way 6A, 1 module complete all as specified and directed.
S&F, Modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F, Socket, 6A - 2/3 pin combined 2 module all as specified and directed.
S&F, Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S&F, Fan step regulator, 120W - 2 module suitable for 1200mm/1400mm sweep ceiling fan, 2 module complete all as specified and directed.
S&F, sheet metal enclosures, single pole & neutral with a two pin & earth plug and socket complete with one single pole, MCB of 20 Amps, 10 KA, 240 volts complete all as specified and directed. Make ;Legrand / Havells/ standard.
S&F, sheet metal distribution board, SPN, 8 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A bus bar complete all as specified and directed
S&F, sheet metal distribution board, 3 phase with neutral ( TPN ) of 4 way 415 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
S&F, in repair, Ceiling rose, PVC/poly carbonate,isolated body three terminals,complete all as specified and directed.
S&F, miniature circuit breakers, type curve ‘B’ , 10 KA, SP, 6 to 32 Amps complete all as specified and directed.
S&F, miniature circuit breakers, Single pole and neutral, type curve ‘C’ 10KA, 40 Amps 230 Volts. complete all as specified and directed.
S&F, miniature circuit breakers, Three pole and neutral, type curve‘C’ 10KA, 63 Amps, 415Volts. complete all as specified and directed.
M&L for sub-main wiring with 2 single core 4 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in PVC concealed conduit ISI marked including its fitting and fixtures such as tee, bends, elbows, junction boxes, etc. including drawing a run of PVC insulated, unsheathed, 650/1100Volts grade, copper conductor multi stranded 4 Sqmm size as continuous earth wire drawn through and connected to main switch/ DB and testing on completion. Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length. (ii) Rates quoted shall be inclusive of cutting wall for concealing conduit and making good the same in cement mortar 1:3.
S&F, in repairs, LED light fitting, batten type, housed in extruded from powder coated aluminium, 20 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size and testing on completion all as specified and directed. Make: Havell / wipro/ Bajaj/ Crompton
S&F, LED 24 watt recess mounting 2 x 2 luminaire of 24 watt, white powder coated CRCA housing with highpower LEDs. Aluminium front frame with flat white high transmission acrylic cover prewired and all accessories Make: Bajaj 24 watt or equivalent in Havells/philiphs
S&F security light luminaries 25 watt with wall mounting bracket of suitable size and clamps, nut bolts etc.having pressure die cast housing with epoxy power coated dark graphite grey colour finish,prismatic polycarbonate cover with individual LED lenses-IP65 prewired Conforming to Crompton of equivalent make of wipro/Havells/Bajaj/ wipro.
S&F of Cealing Fan fan 1200 mm Sweep ,220 Volts ceiling fans complete with down rods and fixing the same with supply of new down rod of size 15 mm dia made of GI pipe med grade aprox 1 metre length incl flexible wire all as specified and directed. complete all as specified and directed. Make : BAJAJ / HAVEELS /USHA
M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 25x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions:-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m.
S&F, LED flood light luminaries 70 Watt, comprising pressure die cast aluinium housing with pre-sired gear tray with LEDs and driver, head resistant, flat glass suitably gasketed for IP-65 protection complete with all accessories pre-wired, fixed on existing bracket with and including necessary reducer/nut/boldt/drilling hole in pipe as per site requirement and making connections with PVC copper wire complete all as specified and directed.
S&F, Street light cable junction boxes IP55/IP65 with metric knowkout for cable entry made out of SMC material, shock & dust proof of inside size 250 x 200 x 100mm as per IS and including TPN aluminium busbar fixed on insulators, 01 Noo. 6 A sP MCB, earth termination with nuts & bolts, and including 02 sets of 25x6mm flat iron cllamps with nuts, bolts and washers including 02 coats of aluminium paint over a coat of primer for flat iron all as specified and directed as per Cat Part No. GSMB 2520 of SINTEX or equivalent make as approved by GE.
M&L for GI bracket suitable for top mounted on steel tubula pole and suitable dia for 70 watts LED fittings, not less then 0.8 mtr long alongwith fixing arrangement i.e. nuts, bolts, washers etc and shall be fixed by maintain 30 degree angle with ground level, complete all as specified and directed.
S&F, 2.5 Sqmm (nominal area) 2 core multistandared copper conductor, PVC insulated sheathed, FRLS cable drawn in steel pole of r connection to street/flood light fitting and making connections complete all as specified and directed.
M&L for steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long) including numbering of poles with aluminium paint and painting up to 1.5 meter above PCC benching of poles in black and white strips 5 number complete all as specified and directed. (Excavation, earht work, foundation concrete and coping etc will be measured and paid seperately).
Supplying & laying, XLPE insulated, PVC inner sheathed, 6 Sqmm, 2 Core, armored with galvanized steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed.
Supply, laying, connecting and testing of LT under ground electric cable 16 sqmm, 4 core,XLPE insulated armoured heavy duty with stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape 1100 Volts grade , laid in trenches or drawn through GI pipe or fixed to wall with providing suitable size of metal clamps, cable glands, aluminium lugs, GI nuts bolts and washers complete wherever required complete all as specified and as directed . Make : Havells / Finolex/ Polycab
Ramdev and Sons
SNEH TRADERS
M/s PATEL ENGINEERING
K K Construction Co
GIRNAR CONSTRUCTION
Shree Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .