Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAccepted-Finance NEW AZAD NAGAR IDGAH MOHALLA BISHUNPUR B POLYTECHNIC DHANBAD DHANBAD 828130 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828130 | L1 | Accepted-Finance QUOTED LOW RATE | |
| 2 | L2₹3.7 L+₹10,764.18 (3.00%)Rejected-Finance | L2 | Rejected-Finance REJECTED | |
| 3 | L3₹3.8 L+₹25,116.42 (7.00%)Rejected-Finance ANGARPATHA KATRASGARH DHANBAD | DHANBAD | DHANBAD | JHARKHAND | 828113 | L3 | Rejected-Finance REJECTED |
Tender Value
₹3.6 L
EMD Value
₹4,500
Closing Date
13 Jan 2026, 6:00 pmClosed
AM (EnM), PB AREA
PB AREA, PUTKI
MAINTENANCE OF MAIN FEEDER FROM 132 KV 6.6 KV O/H LINE, OFFICE AND AREA OFFICE LT LINE, SINGH BASTI, MASJID PATTI, B AND C TYPE COLONIES, PREM NAGAR, HOSPITAL LT LINE AND S/S AN W/BRIDGE LT O/H LINE TO AVOID FREQUENT BREAK DOWN UNDER P.B PROJECT
2025_BCCL_350051_1
BCCL/PBA/AM(EnM)/2025-26/60 DATED-03.01.2026
Open Tender
Excavation Department Work
Percentage
12 days
PB PROJECT COLLIERY
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,500
23 Jan 2026
3 Jan 2026
14 Jan 2026
3 Jan 2026
13 Jan 2026
3 Jan 2026
3 Jan 2026 - 6 Jan 2026
A) FOR Office & Area Office LT O/H line maintenance-Supplying and erection of Stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod (CPWD SOR' 2012, P-41, 13.1)
Damage & weak jumper repairing with binding wire etc.
Erection/Sagging of Conductor of 7/2.11 mm to 7/3.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.21)
Taking down of one no. PVC insulated power cable of 11 KV grade of 70 sq mm for making fresh lead (CPWD SOR' 2012, P-28, 8.3.1)
Laying/Hanging of one no. PVC insulated power cable of 70 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.1)
Opening & erection of both end cable with switch and O/H line
Tree and branches cutting below O/H line (Semi Skilled)
B) FOR main feeder 6.6 KV O/H line maintenance-Damage & weak jumper repairing with binding wire etc.
Opening jumper for changing of faulty Disc insulator
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Supplying and erection of Stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod (CPWD SOR' 2012, P-41, 13.1)
Supply & erection of 11 KV Disc insulator CPWD SOR' 2012, P-42, 13.11)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Opening of jumper of AB Switch and O/H line
Repairing and Erection of AB Switch
Re-jumpering of AB Switch and O/H line
Erection of cradle guard
Tree branches and bush cutting/trimming (Semi Skilled)
C) FOR 550V, CISF Camp LT & Regional Store LT O/H line maintenance- Damage & weak jumper repairing with binding wire etc.
Taking down of one no. PVC insulated power cable of 11 KV grade of 185/240/300 sq mm for making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Laying/Hanging of one no. PVC insulated power cable of 11 KV grade of 185/240/300 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Laying/Hanging of one no. PVC insulated power cable of 1.1 KV grade of 70 sq mm after making fresh lead (CPWD SOR' 2012, P-27, 7.5.2)
Erection of metallic pole of 8 to 10 metre length in cement concrete (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication and erection of bracket & clamps
Supplying & erection of MS Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Erection/Sagging of Conductor of 7/2.11 mm to 7/3.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.21)
Fixing & fitting of 400 watt flood light on O/H pole with connection
Misc. work in LT line for solar panel (Semi Skilled)
Dismantle of jumper from O/H line
Making new fresh jumper with O/H line
Tree branches and bush cutting/trimming (Semi Skilled)
D) FOR Singh Basti & Masjid Patti LT O/H line maintenance- Transportation of pole from store to site
Erection of metallic pole of 8 to 10 metre length in cement concrete (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication and erection of bracket & clamps
Supplying and erection of MS Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection/Sagging of Conductor of 7/2.11 mm to 7/3.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.21)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Dismantle of pole (CPWD SOR' 2012, P-40, 12.42)
Transportation of dismantled pole from site to store
Tree branches and bush cutting/trimming (Semi Skilled)
E) FOR Sub-Station & Store work- Fabrication of 5 nos angle for hanging of cable
Excavation and concreting of above angle in ground
Transportation of Rail pole at site
Erection of metallic pole in cement concrete (CPWD SOR' 2012, P-36, 11.3.1)
Dismantle of burnt indoor cable joint
Taking down of one no. PVC insulated power cable of 11 KV grade of 120 sq mm for making fresh lead (CPWD SOR' 2012, P-28, 8.3.1)
Transportation of 120 sq mm cable from R/Store
Laying/Hanging of one no. PVC insulated power cable of 11 KV grade of 120 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.1)
Supply & making indoor cable end jointing including lugs and other jointing materials for 120 sq mm size of 3 core, XLPE Aluminium cable of 11 KV grade (CPWD SOR' 2012, P-34, 10.1.2)
Making/Erection of new Earthpit with G.I Pipe, charcoal & salt
Making neutral connection of Transformer & switch with earthpit by G.I strip/wire or by provided cable
Transportation of 1000 mtrs Rabbit conductor from South Balihari Colliery after opening from drum (Semi Skilled)
Transportation of 5 nos 8 mtrs poles from Regional Store to Colliery Store (Semi Skilled)
Transportation of 2000 (1000+1000) mtrs Rabbit conductor from Regional store 5 heads * 2 days = 10 heads
Transportation of 4 nos 6" pipe for making pole from Regional store
Man power for making 12 nos Pole by welding
Misc work at sub station (Semi Skilled)
F) FOR Prem Nagar, B & C-Type Colony LT O/H line maint.- Damage & weak jumper repairing with binding wire etc.
Transportation of pole from store to site
Erection of metallic pole of 8 to 10 metre length in cement concrete (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication & erection of bracket & clamps
Supplying & erection of MS Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Tree and branches cutting below O/H line (Semi Skilled)
G) FOR Hospital line & Weigh Bridge LT O/H line maintenance- Opening of burnt cable jumper from O/H line
Taking down of one no. PVC insulated power cable of 11 KV grade of 185 sq mm for making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Laying/Hanging of one no. PVC insulated power cable of 11 KV grade of 185 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Jumpering cable with O/H line after making fresh lead
Fixing & fitting of flood light on O/H pole with connection
Damage & weak jumper repairing with binding wire etc.
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.69 MB
BOQ_363252.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .