Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC CHERUKUNNU P O KANNUR 670301 | CHERUKUNNU | KANNUR | KERALA | 670301 | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.6 L+₹8,045.86 (5.26%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹1.6 L
EMD Value
₹4,023
Closing Date
26 Feb 2024, 10:00 amClosed
SECRETARY KURUMATHUR GRAMA PANCHAYAT
SECRETARY KURUMATHUR GRAMA PANCHAYAT CHORKALA,670142
RE ETENDER FOR HIGHMAST MINIMAST LIGHT REPAIR
2024_DP_660546_1
SC2/2677/23
Open Tender
Electrical and Maintenance Works
Supply and Service
180 days
KURUMATHUR GRAMA PANCHAYAT
Please refer Tender documents.
3 documents required · 3 mandatory
₹622
Yes
₹4,023
Yes
27 May 2024
19 Feb 2024
27 Feb 2024
19 Feb 2024
26 Feb 2024
19 Feb 2024
Amount
General Electrical Work
OD341376/2023-2024:Dismantiling existing defective 40 WLED Flood light fitting from lowmast/minimast and supply and replacing of approved make LED flood light fitting 50/60 with IP67 grade. Diecast Aluminium body , bracket, LED chip of approvede make including testing & giving connection Light fitting shall have replacement guarentee for 3 years.
OD341377/2023-2024:Suppling and providing or replacing analog type timers for LED street lights. Including setting timer 6:30 P.M to 6 A.M Havels, LHT etc.
OD341378/2023-2024:Supply and providing or repalcing defective 2 pole contactor for street lights.
OD341379/2023-2024: Supply and providing or repalcing SPD 10KA grade including providing earth connection as required.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
OD341380/2023-2024:Cleaning, scraping, painting existing metering cubicle/control gear box. Including making good working condition.
OD341381/2023-2024:Providing of railway pattern locking arrangement and to ensure locking provision for control gear box/meterimg cubicle
OD341382/2023-2024:Checking contactor, cleaning and makng good working condition of all light fittings ivluding attending annual maintenance and periodical inspection ensuring good working of all minimast for 3 year .Including attending petty repairs, replacement etc. as required once in every 3 months the AMC amount to be released after one year, for two years.
Nidheesh P
Bidder Name
ELITE ELECTRICALS
Nidheesh P
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1022767.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .