Superintending Engineer
Office of the Superintending Engineer Mechanical Circle Uttarakhand Peyjal Nigam 16 Laxmi Road Dehradun
SITC of Transformers and HT panels outdoor type under Bhairav Garhi GOV Pumping Water Supply Scheme Combined in block Dwarikhal and Jaiharikhal of District Pauri Garhwal
2018_MDPEY_8668_3
Letter No. 284/E-Nivida/05 Dated 01.02.2018
Open Tender
Electrical Works
Item Rate
120 days
Distt Pauri
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
Executive Engineer Mechanical Division UKPJN
₹4 L
30 Jan 2020
9 Apr 2018
21 Apr 2018
9 Apr 2018
20 Apr 2018
13 Apr 2018
Amount
Supply, Installation, Testing & commissioning of 11/0.44 KV, 3 phase, 50 C/s AC supply copper wound electric transformers (with Transformer oil) for following sites including double loop earthing as per the clause no. 6.1 of technical specification, Change Over Switch, Cable trench etc. as required.
250 KVA Transformers for I/W (Stage-I)
1000 KVA Transformers for Stage-II (Stage-II)
750 KVA Transformers for Stage-III (Stage-III)
750 KVA Transformers for Stage-IV (Stage-IV)
750 KVA Transformers for Stage-V (Stage-V)
Supply and laying of 95 sq. mm 3 core 11 KV ,H.T. XLPE Armoured cable from H.T. panel to 11/0.44 KV Transformer side the switch room.
Supply and laying of 70 sq. mm 3 core 11 KV ,H.T. XLPE Armoured cable from H.T. panel to 11/0.44 KV Transformer side the switch room.
Supply and laying of 50 sq. mm 3 core 11 KV ,H.T. XLPE armoured cable from H.T. panel to 11/0.44 KV Transformer side the switch room.
S/F of 11 KV HT indoor heat shrinkage termination kit suitable for 95 sq. mm 3 core 11 KV, H.T. XLPE cable.
S/F of 11 KV HT indoor heat shrinkage termination kit suitable for 70 sq. mm 3 core 11 KV, H.T. XLPE cable.
S/F of 11 KV HT indoor heat shrinkage termination kit suitable for 50 sq. mm 3 core 11 KV, H.T. XLPE cable.
Testing of transformers and HT panels at manufacturer works.
Testing of transformers and HT panels at site.
Double loop GI earthing of teransformer and HT panel (separate for neutral and body) complete in all respects. (As per I.E rules and specified in specification) (1 Job includes 08 nos earthing station per stage, 2 Nos. each for neutral of the transformer, 04 Nos for body of both transformer and 02 Nos. for H.T panel.)
Double loop GI earthing of teransformer and HT panel (separate for neutral and body) complete in all respects. (As per I.E rules and specified in specification) (1 Job includes 08 nos earthing station per stage, 2 Nos. each for neutral of the transformer, 04 Nos for body of both transformer and 02 Nos. for H.T panel.)
Katsons Technologies Private Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .