Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.2 LAccepted-AOC A 6 200 EAST GOKALPURI LONI ROAD EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | ₹52.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹62.4 L+₹10.3 L (19.7%)Rejected-Finance 2 SHANTI NAGAR SECTOR 3 HIRAN MARGI UDAIPUR 313002 | UDAIPUR | UDAIPUR | RAJASTHAN | 313002 | ₹62.4 L+₹10.3 L (19.7%) | L2 | Rejected-Finance Not L1 |
| 3 | L3₹67.9 L+₹15.8 L (30.3%)Rejected-Finance | ₹67.9 L+₹15.8 L (30.3%) | L3 | Rejected-Finance Not L1 |
| 4 | L4₹68.0 L+₹15.9 L (30.5%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | ₹68.0 L+₹15.9 L (30.5%) | L4 | Rejected-Finance Not L1 |
| 5 | L5₹68.1 L+₹15.9 L (30.5%)Rejected-Finance FLAT NO 18 3RD FLOOR QUEENS CASTLE 100 FEET ROAD LAKSHMI NAGAR NANGANALLUR CHENNAI 600 061 | CHENNAI | TAMIL NADU | 600061 | ₹68.1 L+₹15.9 L (30.5%) | L5 | Rejected-Finance Not L1 |
Tender Value
₹76.7 L
EMD Value
₹1.5 L
Closing Date
17 May 2024, 11:00 amClosed
Asst GM EE
Asst GMEE AAI Calicut International Airport Calicut Airport PO Malappuram - 673647
Replacement of existing LT Cable in Operational area including Operational area lighting at Calicut International Airport
2024_AAI_194065_1
AAI/CL/EE/227/NIT-03/24-25
Open Tender
Electrical Works
Works
90 days
AAI Calicut Airport
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,120
Yes
₹1.5 L
21 Nov 2024
25 Apr 2024
20 May 2024
26 Apr 2024
17 May 2024
26 Apr 2024
26 Apr 2024 - 3 May 2024
Amount
Supplying of XLPE insulated, PVC sheathed, armoured Aluminium conductor Power Cable of 1.1 KV grade of following size etc as per IS 7098 Part-I 1988 with upto date amendments etc as required. (a) 4 C x 16 sq mm
Supplying of XLPE insulated, PVC sheathed, armoured Aluminium conductor Power Cable of 1.1 KV grade of following size etc as per IS 7098 Part-I 1988 with upto date amendments etc as required. (b) 3.5 C x 185 sq mm
Supplying of XLPE insulated, PVC sheathed, armoured Aluminium conductor Power Cable of 1.1 KV grade of following size etc as per IS 7098 Part-I 1988 with upto date amendments etc as required. (c) 3.5 C x 240 sq mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. A) 3 x 1.5 Sq.mm
Fixing of following sizes of medium class GI pipe along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on wall surface/ Cable tray as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on wall surface/ Cable tray as required. (b) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number XLPE/ PVC insulated PVC sheathed aluminium/copper conductor cable of 1.1 KV grade of following sizes on wall surface/ Cable tray as required. © Above 185 sq.mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (a) Above 95 sq.mm and upto 185 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (b) Above 185 sq.mm and upto 400 sq.mm
Supplying of following size HDPE pipe ISI marked conforming to IS 4984,complete as required. (a) 90 mm dia (PE 63 PN 6)
Laying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 4984, complete with fitting and cutting, jointing etc. in the existing trench, complete as required. (a) 50 mm dia (PE 63 PN 6)
Laying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 4984, complete with fitting and cutting, jointing etc. in the existing trench, complete as required. (b) 59 mm dia (PE 63 PN 6)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (a) Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (b) Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (c) Above 185 sq.mm and upto 400 sq.Mm
Excavation for cable trenches of depth up to 75 cm and width up to 30 cm in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a leadof 50 meters.
Excavation of the cable trenches in hard rock not exceeding 30 cm in width, and depth upto 75 cm, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meters.
Providing and laying in position cement concrete of grade 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including the centering, shuttering, strutting, propping etc and removal of form work.
Providing and laying in position cement concrete of grade 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including the centering, shuttering, strutting, propping, leveling etc and removal of form work, at bottom of each perimeter pole with size 200 cm x 200 cm x 10 cm. ( 1 Job = P&L of PCC of size 200cmx200cmx10cm at the bottom of each perimter pole)
Supply and installation of Digital time switch ( Equivalent to L&T make CAT NO. 67DDT0 ) including required interconnections etc complete as required.
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. (a) 40 mm dia
E/O STREET LIGHT POLE : Erection of conical metallic pole /FRP pole by providing RCC foundation 450 mm x 450 mm x 1400 mm or as specified by the OEM, providing and embedding foundation bolt of size Φ 20 x 750 mm (or as specified by the OEM of the pole), fixing the base plate , providing and embedding Φ 63 mm reinforced PVC flexible conduit for cable entry and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) grade around the foundation of the pole with dimensions 1 m x 1 m x 0.1 m ( Length x Breadth x Thickness ). etc. complete as required.
D/O STREET LIGHT POLE : Detatching the existing metallic pole from cement concrete foundation by suitable means, as approved by AAI, providing and fixing base plate of size 250 mm x 250 mm x 20 mm or as specified by the OEM by way of continuous welding, providing weather coat with bituminous based paint etc complete as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.(GI wire will be supplied by AAI).
S/O LED LIGHT FIXTURES : Supply of LED street light/flood light fixtures of efficacy minimum 110 lm/w,, CRI ≥ 70,THD ≤10, IP 65 or higher, surge protection ≥ 4 kV, P.F ≥ 0.95, High pressure diecast aluminium/standard alloy housing, warranty period of 5 years from date of completion, total power consumption of not more than 110% of rated power, any of the following make of LED - Nichia/Cree/Osram/Lumiled (Philips)/Sharp/Seoul/Everlite/ Citizen(Japan)/ Bridgelux(USA)/ Samsung and completely complying to the specifications in the tender document of following wattage. (a) 100 W LED street light fixtures
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (b) 3.5 X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (c) 3.5 X 240 sq. mm (62mm)
Supply and fixing of SMC loop in loop out box of inside dimension 240 X 130 X 95 ( equivalent to Sintex make model No.GS-JB-2817) including suitable 20 A 4 way connector and din rail etc, including making required interconnections as required.
Supply of Fibreglass Frangible Uniform Pole of 6.0Mtr height having min. 100mm Dia, with GI fixed base plate provided with clamps for lighting arrester and foundation bolts (any other accessories not include), meeting frangibility criteria as per ICAO Part-6 design manual meeting wind speed requirements & frangibility criteria i.e. Force Imparted ≤45 kN & Energy Imparted ≤55kJ. (Type test report of frangibility and deflection is required.) The Fibreglass Pole material must be UV Resistant type tested as per ASTM G-154 for Min. 2000 hours (Equivalent to 10 year outdoor life), with reduction in tensile & flexural strength not more than 15% also type tested as per ASTM E-84 meeting flame spread ≤15. (Type test to be provided along with tender)
Supply and installation of Digital time switch ( Equivalent to L&T make CAT NO. 67DDT0 ) including required interconnections etc complete as required.
E/O STREET LIGHT POLE : Erection of conical metallic pole /FRP pole by providing RCC foundation 450 mm x 450 mm x 1400 mm or as specified by the OEM, providing and embedding foundation bolt of size Φ 20 x 750 mm (or as specified by the OEM of the pole), fixing the base plate , providing and embedding Φ 63 mm reinforced PVC flexible conduit for cable entry and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) grade around the foundation of the pole with dimensions 1 m x 1 m x 0.1 m ( Length x Breadth x Thickness ). etc. complete as required.
SITC of LED LIGHT FIXTURES : Supply, Installation , Tesating and commissioning of LED street light/flood light fixtures of efficacy minimum 110 lm/w,, CRI ≥ 70,THD ≤10, IP 65 or higher, surge protection ≥ 4 kV, P.F ≥ 0.95, High pressure diecast aluminium/standard alloy housing, warranty period of 5 years from date of completion, total power consumption of not more than 110% of rated power, any of the following make of LED - Nichia/Cree/Osram/Lumiled (Philips)/Sharp/Seoul/Everlite/ Citizen(Japan)/ Bridgelux(USA)/ Samsung and completely complying to the specifications in the tender document of following wattage. The Installation of LED fixtures on the FRP Poles of Item No.24 shall be carried out along with necessary brackets and accessories as required.
MPC ELECTRICALS AND ENGINEERS
surbhi association
Mona Generator Services Pvt. Ltd.
Balaji Engineering
LINSTA SERVICES
Awasthi Electric Works
vk sam engineering
VIJAYA ELE-TECHS (P) LTD.
ABM ELECTRICALS
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .