Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹7.0 L Quoted ₹7.4 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹7.7 L+₹29,644.40 (4.00%)Rejected-Finance 199 79 SADAR BAZAR LANSDOWNE TAHSIL LANSDOWNE | ₹7.7 L+₹29,644.40 (4.00%) | L2 | Rejected-Finance Being Not Lowest |
Tender Value
₹7.6 L
EMD Value
₹15,280
Closing Date
28 Mar 2022, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
SPECIAL REPAIR TO BUILDING NO T-18 OF AGE (I) MES AT LANSDOWNE UNDER AGE (I) LANSDOWNE
2021_MES_485262_6
8667/E8
Open Tender
Civil Works
Item Rate
120 days
AGE I Lansdowne
Class E Cat a i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹15,280
8 Apr 2022
14 Mar 2022
30 Mar 2022
14 Mar 2022
28 Mar 2022
16 Mar 2022
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating AZ-150 GI based corrugated steel sheet 0.50mm thick of any colour (ISI Marked) having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating AZ-150 GI based plain steel sheet 0.50mm thick (ISI Marked) of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling timber scantling 40 sqcm and over in section,in any position, any description complete all as specified and directed.
M & L for 2nd class softwood in timber scantling for wall panelling, ceiling, roof truss,post, purlins, rafters and similar work (Clean sawn Timber framed and fixed type) including necessary coating framed joints with glue, complete all as specified and directed.
Dismantling of tmber scantling in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section in any description complete all as specified and directed.
S & F for 2nd class hard wood fillets square or rectangular or triangular in section wrought fixed to wall with screw area exc 13 but n. exc 25 sq cm complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M & L for 2nd class soft wood boarding 20 mm thick planed one side, rebeted or fixed with screw, fixed to timber frame work with nails complete all as specified and directed. .
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material,outside cantt area distance not exceeding 1.5 KM. complete all as specified and directed.
Material & labour for Rendering 10 mm thick CM 1:6 on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M & L for Rendering 15 mm thick in two layers i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even fair finish complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Material & labour for Rendering 5 mm thick CM 1:3 using water proofing liquid compound as per manufacturer's instructions on brick or concrete surfaces of ceiling /chajja's finished even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Supply only liquid water proofing compound.ISI marked complete all as specified and directed.
M&L for preparation of new surface of wall and applying two coat of Anti -fungel acrylic emulsion paint Make-Berger (wall masta),or equavlent in Asain or nerolac including one coat of primer complete all as specified by manufacturer complete all as specified and directed. by Engineer-in-charge .
M&L for preparation of new surface of wall and applying two coat of Acrylic Emulsion Paint over a coat of primer after applying wall care putty as per manufacturer instructions including preparation of surface , complete all as specified and directed.
M&L for Complete removal of existing treatments by mechanised method from wall by scraping and filling the damage portion with wall putty or cement mortar as required at site and applying two coat of Acrylic Emulsion Paint over a coat of primer after applying wall care putty as per manufacturer instructions including preparation of surface , complete all as specified and directed.
M&L for Preparation of new wooden surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint Ist quality over a coat of primer complete all as specified and directed.
M&L for Preparation of old wooden surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint Ist quality after removal of existing treatment from old surface with help of thiner or other removing chemical materilas complete all as specified and directed.
M & L for preparation of old steel surafces of any description over 10 cm width or girth & applying two caots of synthetic enamel paint Ist quality after removal of old existing treatments with help of thiner or other removing chemical materilas complete all as specified and directed
M & L for preparing of new plastered or un plastered surface of ceilings and applying three coats of white wash complete all as specified and directed.
Material & Labour for 300x300x 7 to 8mm thick:- Non-Skid light coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.06 Sqm and not exc. 0.11 Sqm, in floor etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 15 mm thick screed bed in cm 1:6 including dismantling of existing old tile. complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I)
Material & Labour for 300X450X 8 to 9 mm thick joint free light coloured glazed ceramic tiles of any design and pattern, as in dado etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 10 mm thick in cm (1:4) backing coat and including dismantling of old tiling and removing old unserviceable materials from the distance not exceeding 1.5 Km complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I) Lansdowne
Material & Labour for 400x400x 7 to 8mm thick Joint free Non-Skid light coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.06 Sqm and not exc. 0.11 Sqm, in floor etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 15 mm thick screed bed in cm 1:6 including dismantling of existing old tile. complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I)
S&F in repairs E-boards, ceiling, 4 mm thick with J framed work with main Tee of size 24 x 28.5 mm made out of PGI sheet .3 mm thick double at web and single at flange, flange coverd with powder coated sheet 0.25 mm thick and wall angle 24 x 24 x .45 mm powder coated for ceiling , ceiling boards 60cm x 60cm x 4mm thick , suspended with GI wire 2mm dia and 2m average length with adjustable hanging device complete including plugging in brick/stone walls with steel rawl plug @ 600 mm C/C Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides and making good all the disturbed portion by painted with two coats of oil bound distemper complete all as spd & directed by GE/Eng-in-Charge.
Taking down Chowkats with shutter exceeding 1.5 sqm . but n . Exc 4sqm each (Without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats with shutter n. exc 1.5 sqm each. (without taking of shutter from the frame) complete all as specified and directed.
Taking down shutter of any description exc. 1 sqm but n exc 2 sqm complete all as specified and directed.
Taking down shutter of any description n. exc. 1 sqm complete all as specified and directed.
S&F for steel ventilators with top hung shutter including hinges steel peg stay complete all as specified and directed.
S& F for 35mm thick, IInd class hard wood plain, framed, panelled factory made shutters ( ISI Marked) (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for 30 mm thick, 2nd class hard wood , glazed & skeleton factory made shutters ( ISI Marked) , open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified.
S & F for FRP door frame : fibre glass reinforced plastic (FRP) door frames shall be three lagged of xross section 90mm x 45mm having single rebate of 32mm x 15mm to recive shutter of 30mm thickness. The laminate door frame moulded with fire retardant grade unsaturated polyster resin and chopped mat. Door frame lainate shall be 2mm thick and shall be covered with fibre glass from all sides, MS stay shall be provided at the bottom to steady the frame. Complete all as specified and directed.
S & F for FRP panelled door shutter FDR door shutter shall be 30mm thick glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacturer made with fire retardant grade unsaturated polyster resin moulded to 3mm thick FRP laminated for forming hollow rails and styles with wooden frame and suitbale blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP panels complete all as specified and directed.
S & F for 2nd Class Hardwood ( SAL) in Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints complete all as specified and directed.
S & F for Butt hinges, 100 mm long stainless steel non magnetic ( ISI marked ) complete all as specified and directed..
S & F for Butt hinges, 75 mm long stainless steel non magnetic (ISI marked) complete all as specified and directed..
S&F for 300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and directed.
S&F for 200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed.
All as per serial item No 39 here in above but 150 mm length of bolt.complete all as specified and directed.
S & F for Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and directed.
S & F for Aluminium handles cast type anodised of size 125 mm long ISI marked complete all as specified and directed.
M&L for Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
S & F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
S&F in repair galvanised mild steel wire cloth ,0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks,or galvanised wire steples complete all as specified and directed.
S&F for 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sq.m. each pane including hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in Stone concrete block or slab walls complete all as specified and directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing to storeyard complete of bore 15mm.complete all as specified and directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing to storeyard complete of bore 20mm. complete all as specified and directed.
S& F for GI tubing 15mm bore, medium grade ISI marked with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) ( heavy grade ISI Marked) , fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
S& F for GI tubing 20mm bore, medium grade ISI marked with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) ( heavy grade ISI Marked) , fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
S & F in repairs vitreous china squatting pan 'orissa pattern 580 mm X 440 mm white (ISI Marked only) with integral foot rests (excluding flushing cistern and heavy duty flushing pipe (ISI Marked only) but incl fixing of flushing cistern, flush pipe (ISI Marked only),12 mm dia 450 mm long PVC connection (ISI Marked only) etc complete) complete all as specified and directed.
S & F for CI Nahani trap 75 mm dia with grating (ISI Marked only) including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) complete all as specified and directed
S & F in repairs stainless steel kitchen sink 1.00 mm thick (ISI Marked only) for kitchen with plugs, washer and waste 32/40mm dia incl bedding in cement mortar on to dwarf wall or including fixing cantilever cast iron brackets and connecting union to waste pipe overall all size 495mmx420mm bowl size 410x330x160mm complete all as specified directed.
S & F in repairs PVC low level flushing cistern (ISI Marked only), valveless, syphonic action dwell type, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 60/90 cm long etc, supplied and fixed, complete all as specified.
S&F for Vitreous china wash hand basin ,white ,flat back of size 550x400mm (ISI Marked only) with PVC connection 15mmdia 450 mm long with PTMT (ISI Marked only) nuts and PVC washer and including cutting for pinning in ends,pair of cast iron brackets and provision of PVC waste pipe 32mm of adequate length , waste coupling 32 mm dia of PTMT half or full threaded Min wt 45 gram,complete all as specified and directed by Engr-in-charge.
Supply only low density PVC pipe 32 mm dia as in waste pipe to sink (ISI Marked only) complete all as specified and directed
Demolition and breaking up 150 mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L for 150 mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed as specified SGSW drain pipes laid in trenches complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in concrete bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipes complete all as specified and directed.
S&F in repair soap dish brass chromimum plated screw 125mm size complete all as spcified and directed
S&F in repair bib tap cast copper alloy with crutch or butter fly handle, screwed down for iron pipe 15 mm bore of tubing fancy type chromium plated (ISI Marked). complete all as specified and directed.
S&F in repair stop valve cast copper alloy screwed down high presure screwed both end for iron pipe 15 mm dia fancy type chromium plated (ISI Marked). complete all as specified and directed.
S&F in repair Pillar taps, Fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe screwed down for 15 mm dia bore GI pipe complete all as specified and directed
S & F in repair 20 mm dia bras chromium palted tubler towel rail D type 60 cm long between flange including one pair of fixing brackets complete all as specified and directed .
S&F in repairs PVC ( SWR ) floor trap ( ISI Marked) of 75mm dia of outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F for PVC (SWR ) bend of 75 mm bore ( ISI Marked) pipe of any radius.complete all as specified and directed.
All as per sl item No. 68 here in above but with access door ( ISI Marked) complete all as specified and directed.
S&F in repairs PVC ( SWR ) waste pipe pipe ( ISI Marked) of 75 mm dia bore in any length ,single socketed with rubber ring joints laid in trenches or in floors.complete all as specified and directed.
All as per item No 70 here in above but 110mm dia ( ISI Marked) complete all as specified and directed..
S & F for PVC ( SWR ) junction single,(single T) equal or unequal 110mm bore with access door ( ISI Marked) .complete all as specified and directed.
S & F for PVC ( SWR ) vent cowl 75mm bore ( ISI Marked). complete all as specified and directed.
S & F as in repairs grating doom 100mm dia ( ISI Marked) with waste hole of PTMT (Min. Wt. 25 gram ) complete all as specified and directed.
Demolition Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc complete all as specified and directed.
M&L for point wiring concealed type with 1.5sq mm PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl PVC rigid conduit not less than 20mm dia with its accessories with provn of CI/pressed steel terminal switch box and white bakelite plastic laminated top sheet cover and fixed with brass screws cup washer for fixing switches/socket/regulators etc for the following, complete all as specified and directed. One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
All as per serial Item No 78 herein above but One 3 pin 5 Amps socket outlet on same board controlled by one, one way 5 Amps piano switch complete all as specified and directed.
All as per serial Item No 78 herein above but One socket outlet 5/3 pin 5 Amps controlled by one switch on independent board complete all as specified and directed.
Material and labour for power point wiring for one 15 Amp switch socket combined outlet point on Independent Board with 2.5 Sqmm PVC insulated unsheathed,stranded copper conductor cable single core 1100V grade with in and including rigid PVC conduit 20mm or higher size medium grade in concealed manner with all PVC conduit accessories with provision of CI/pressed steel terminal switch box & white bakelite plastic laminated top sheet cover fixing with brass screws and cup washers and 1.5Sqmm PVC insulated unsheathed stranded copper single core 1100V grade as earth wire & wire connected with the main earth point complete all as specified and directed.
S&F for switch piano flush type single pole, one way 5/6 Amps complete all as specified and directed.
S&F for switch piano flush type single pole, one way 15/16 Amps complete all as specified and directed.
S&F for socket outlet flush type 3/5 pin 5/6 Amps 230V AC complete all as specified and directed.
S&F for socket outlet flush type 5/6 pin 15 Amps 230V AC complete all as specified and directed.
Supply & fixing for lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting complete all as specified & directed.
M&L for ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as specified and directed.
S&F for bell push piano flush single pole one way 5/6 Amp complete all as specified and directed.
S&F for bell ding dong elelctric 230V AC single pole complete all as specified and directed.
S&F for MCB DB TPN 4 way with 200 amps 415 V rated copper busbar in sheet steel enclosure double door type complete all as specified and directed.
Supply & fixing for MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply & fixing for MCB, TPN, AC, 415 volts of 63 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
S&F for LED lights fitting 1x18 Watt,220V AC decorative box type with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose comlpete all as specified & directed .
S & F for LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder complete all as specified and directed.
S&F for sub main wiring with two single core PVC insulated,unsheathed, stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, stranded copper conductor cable as earth wire in and including rigid PVC conduit 25mm dia or higher, medium grade ISI marked and earth wire connected to common earth dolly complete all as specified and directed. Note: Two run of 6sqmm cable, one run of 6sqmm cable and one run of PVC conduit shall be measured as one unit
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25mtr depth and top edge of the earth plate not less than 1.5mtr below normal ground level connected to galvanised earth lead wire 4.0Sqmm dia by means of nuts,bolts & washer etc. Earth wire connected upto main earth point/DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 ( using 20 mm graded stone agregate) and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of ms bar @ 15 mm CIC with both way lifting arrangement complete including all necessary excavation & earth work complete all as specified and directed.
M/S Balaji Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .