Office of SE,SWEC,PWD, MIDNAPORE
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Construction of (Gplus4) District Judge Court building within the campus of District Judge court in the district of Purulia--Electrical Installation work for Installation of passengers lift and Air-Conditioning system
2021_WBPWD_321748_4
WBPWD/SE/SWEC/NIQ39/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
PURULIA
Please refer Tender documents.
3 documents required · 3 mandatory
₹98,100
Office of SE / SWEC, PWD, Midnapore
26 Apr 2022
9 Aug 2021
25 Aug 2021
9 Aug 2021
23 Aug 2021
12 Aug 2021
11 Aug 2021
Amount
PART-A [E.I work for LIFT]
Supplying and fixing 415V, 100 A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(Make-L & T/Siemens/Schneider)
Supplying and fixing double door 4Way ( Up to 160 A ) Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Legrand/ Siemens/Schneider]
Supplying and fixing 4 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment [Legrand/ Siemens/Schneider]
Supplying and fixing 415 V 100A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection [Legrand/ Siemens/Schneider]
Supplying and fixing 240/415 V 4P 100A MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection [Legrand/ Siemens/Schneider]
Supplying and fixing double-door (2+12) way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Legrand/ Siemens/Schneider]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection [Legrand/ Siemens/Schneider]
6-32 A SP [Legrand/ Siemens/Schneider]
63 A TP [Legrand/ Siemens/Schneider]
Supplying and fixing 240/415 V 40A DP MCB Isolator on din rail of existing DBs and necessary connection. [Legrand/ Siemens/Schneider]
Supply and fixing Four Pole 63 A RCCB with sensing current 300 mA [Make- Havells, DHRGCRFF 3000063] or eqv. Make of Legrand/Siemens
Supply of 4 Core 50 Sqmm. XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts [Make : Polycab / Havells / Gloster / RR Kabel]
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables incl. Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials for 4 core 50 Sqmm. AL. XLPE Armoured Cable
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 36/0.3 (1.5 sqmm) + 1 x 36/0.3 (1.5 sqmm) [Make- Finolex/RR kable/Polycab]
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) [Make- Finolex/RR kable/Polycab]
2 x 56/0.3 (2.5 sqmm) + 1 x 36/0.3 (1.5 sqmm) [Make- Finolex/RR kable/Polycab]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) [Make- Finolex/RR kable/Polycab]
Supplying and fixing 25 mm PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish[(Avg run 6 mtr)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Polycab/Finolex) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish.(PVC rigid conduit on surface and Switch board surfaced) [on board]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchoor) on sheet metal switch board fixed on wall incl.S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
S&F 22 watt LED tube fittings (Phillips make, CAT No:-TMC 501PIXT- LED 22W P3241) with 4ft, 18 watt LED Tubular lamp (Phillips Essential) suspended 25 cm below the ceiling with 2 no 20 mm dia EI conduit (14 swg) supports fixd with "L" type MS Clamp and necessary connection by 2x24/0.20 mm (1.5sq. mm)flexible copper wire of 1.10 mt length and mending good damages to original finish and painting etc.
S&F LED Bulk head fitting. Make Philips cat no.WT202W LED6S NW PSU S2 PC or equivalent make of Crompton/Wipro
S & F 230 v, 9"(225 mm) sweep heavy duty AC exhaust Fan complete with louver shutter,nuts & bolt (6 x 62mm long) frame etc after cutting wall incl making neat cemented finish of the hole incl connection with 3 x 1.5 sqmm copper conductor.(EPC)
Supply & Fixing of GI louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for 15 inch exhaust fan
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by TATA medium GI Pipe
Excavation of soil for installation of Earth Electrode and filling & ramming, for Morrum soil @ 1.75Cu mtr per earthing.
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supplying & fixing GI earth strip of galvanized (Hot Dip) MS flat 25 mm x 6 mm in under ground trench and making welding at each joint .
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
Supply & fittings of LED Street Light [Male- Crompton ASTRO, Cat no- LSTS-30-CDL-M ] Or equiv, Philips, Havells]
Supply & fixing 450 mm Metal Blade type Wall Bracket fan complete with accessories (Make- Orient Tornedo Wall II) or equiv Crompton/ Usha.)
Supplying & fixing of 40mm medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
R.C.C Road cutting for earthing & finishing with same.
Part-B [E.I work for AC Machine]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
FP 415V, 6-32 A (for 3 TR,4 TR,5 TR,5.5 TR AC)
FP 415V, 40 A (for 7.5 TR AC)
FP 415V, 63 A (For 11 TR AC)
DP 240V, 20 A (for 1.5 TR AC for Anti Chamber)
Supplying and fixing 25mm size PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Finolex/RR Kable/Polycab) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC (For 6-32 Amp FP MCB)
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC (for 40 Amp FP MCB)
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC (For 63 Amp FP MCB)
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC (For DP 20 AMP MCB)
Supply & Fixing 240 V, 20 A plug socket (Brand aproved by EIC), with 16/20A plug top, on 100mm x100m x 65mm sheet metal switch board(16 SWG) with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. (for 1.5 TR AC at Ante Chamber at GR Floor & 4th Floor)
Supplying and fixing double door 8 way (upto 160A) Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make:-Siemens (8GB31573RC)/ Schneider/ Legrand]
Supplying and fixing 415 V, 100 A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection [Make:-Siemens / Schneider/ Legrand]
Supplying and fixing 240/415 V MCB of Breaking ncapacity 10kA & C characteristics on din rail of existing DBs and necessary connection [Make:-Siemens / Schneider/ Legrand]
40 A TP MCB
63 A TP MCB
Supplying and fixing 415 V, 100 A, 3 Pole MCCB( Make-L&T, type-TN630D, Cat no:- DNO-100D / Legrand / siemens] of Breaking capacity 50kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing SMDB Power distribution board/ enclosure and necessary connections.(at SMDB of 4th floor)
Supply & Delivery of 4 Core 70 Sqmm XLPE Insulated & Sheathed Armoured Aluminium Conductor Cables for Working Voltage up to 1100 Volts of following sizes [Make Gloster/ Havells/ Polycab/RR Kabel ] [From SMDB to VTPNDB]
Laying of 4 Core 70 Sqmm XLPE Insulated & Sheathed Armoured Aluminium Conductor Cables onwall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables incl. Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials [4 Core 70Sqmm]
RAHUL TRADERS
SREE LALJI
MOON LIGHT HOUSE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .