Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC QUOTED AMOUNT IS LOWEST AND REASONABLE | |
| 2 | L2₹22.1 L+₹1.6 L (7.83%)Rejected-Finance | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE | |
| 3 | L3₹22.2 L+₹1.8 L (8.58%)Rejected-Finance | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE | |
| 4 | L4₹24.5 L+₹4.0 L (19.6%)Rejected-Finance VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L4 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE |
Tender Value
₹23.1 L
EMD Value
₹46,260
Closing Date
15 Nov 2024, 6:00 pmClosed
GARRISON ENGINEER
GE RAMGARH CANTT
SPECIAL REPAIR TO OTM ACCN BLDG NO. SMB -46 (OLD JASWANT COY) AT PRC RAMGARH CANTT
2024_MES_680190_1
8300/3291/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH CANTT
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹46,260
Yes
16 Jan 2025
18 Oct 2024
23 Nov 2024
18 Oct 2024
15 Nov 2024
1 Nov 2024
Amount
Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed.
Dismantling wall and ceiling boarding of any description or any thickness complete all as specified and directed.
Dismantling of wooden scantling 40 Sq.cm and over in section in any position as in unframed work complete all as specified and as directed.
Dismantling of wooden fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section as in unframed work complete all as specified and as directed.
M&L for second class hard wood in scantling clean sawn, timber framed & fixed complete all as specified and directed.
S & F second class hard wood plain, fillets, square, rectangular or triangular in section clean sawn, secured with nails of sectional area exceeding 06 Sq cm but not exceeding 13 Sq cm complete as specified and as directed.
S&F 2nd class hardwood plain fillets, square, rectangular or rectangular in section, clean sawn secured with nails sectional area exceeding 13 Sqcm but not exceeding 25 Sq.cm complete all as specified & directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with Creosote oil complete all as specified & directed.
S&F for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm using Main and cross tee of size 36.5mm X25mm X1.4mm,weighing 0.24 kg/RM and 23.5mmX26.4mmX1.4mm weighing 0.191Kg/RM respectively. the snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia GI wire, J bolts, nuts and washers as per manufacturer's instructions complete all as specified and directed.
S &F 4 mm thick Non asbestos fibre cement building board in ceiling flat or sloping or laid/inserted to timber /GI/Aluminium frame work with screw complete all as spcified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas ,fixed with self tapping screws complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of a colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screws complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the all rubbish off from the premises complete all as specified and directed.
Demolition of stone slabs of any description or thickness in floors, aprons etc, laid ,bedded & pointed in any mortar in floor,walls ,aprons etc ., complete all as specified and directed.
M&L for machine cut kota stone slab flooring 22mm -25 mm thick of size not less than 575 mm X 575 mm, over laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing with bee wax polish over & including 20 mm thick screed bed in CM (1:6) as in stair case complete all as specifed & directed.
M&L for machine cut kota stone slab in skirtings,riser of steps ,dado & pillar 22 mm to 25 mm thick laid and jointed with grey cement slurry pointed with cloured cement to match the shade of the slab including grinding rubbing & polishing with beewax polish over & including 10 mm thick backing coat in CM (1:4) etc complete all as specifed & directed.
M&L for Vitrified coloured (dark shed) ceramic floor tiles 10 mm thick polished (Square/rectangular) area of each tile not exceeding 0.36 Sqm, in floors etc, set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles, over & including 15 mm thick screed bed in cement mortar (1:4) etc complete all as specified & directed.
M&L for Vitrified coloured (dark shed) ceramic floor tiles 10 mm thick polished (Square/rectangular) area of each tile not exceeding 0.36 Sqm ,on vertical surface such as skirting / dado etc ,set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles, over & including 10 mm thick backing coat in cement mortar (1:4) etc complete all as specified & directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (above or below GL) including removal of all rubbish off from the site complete all as specified and directed.
M & L factory made antifungal chequered cement concrete tiles 30cm X 30cm X 22mm to 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment as in floors, over and including 20 mm thick cement screed bed in cement mortar (1:6) complete all as specified & directed.
M&L for plain cement concrete 1:4:8 ,type D-2 (using 40 mm graded crushed stone aggregate) as in foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly, sub base ,filling in floor etc complete all as specified and directed.
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) etc including builders hardware etc & making good disturbed surface of wall with CM 1:3 complete all as specified and directed
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) including builders hardware etc & making good disturbed surface of wall with CM 1:3 complete all as specified and directed
S&F for 1.25 mm thick pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including plain cement concrete 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregate) as in filling in pressed steel door including a bitumen coat of bitumen paint side of pressed steel door frame before filling of PCC complete all as specified and directed. Note: The quoted unit rate under this item shall deemed to be included one shop coat of primer and bitumen paint.
S & F 35 mm thick, factory made, IInd class hard wood plain framed panelled door shutter (three panel) with lock rail and panel of 12 mm thick BWP commercial ply . The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed .
S & F 35 mm thick, factory made, IInd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc. (divided into squares with plain, chamfered or rounded, mitred and rebated sash bars any number size of members), beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a); kiln seasoned & chemically pressure treated etc complete all as specified and directed . (Note:- (i)Glass / wire cloth shall be measured & paid separately.(ii) Sample of shutter in sample room of GE office.)
S & F Aluminium anodised barrel tower bolts of extruded section and fixed 200 mm long complete all as specified & directed. .
S & F Aluminium anodised handles of extruded section and fixed 125 mm long complete all as specified & directed.
S&F 250 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed.
S & F 150 mm (overall length of cover plate) floor door stopper with rubber shoes aluminium alloy body and tongue, anodised ,with hard drawn steel spring,fixed in floor complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staples etc complete all as specified & directed.
S&F factory made steel window with side hung shutters including projecting type hinges with steel handles and steel peg stay complete without glazing bars, dovetailed or welded with four Nos mild steel flat iron 25 mm X 3mm ,200 mm length (appx)& two Nos mild steel tower bolt 150 mm long and one peg stay on each leaf complete all as specified and directed
S&F steel window with side hung shutters including projecting type hinges with steel handles and steel peg stay complete with glazing bars, dovetailed or welded with four Nos mild steel flat iron 25 mm X 3mm ,200 mm length (appx) & two Nos mild steel tower bolt 150 mm long and one peg stay on each leaf complete all as specified and directed
M&L for framed work such as grills,gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work & for portions framed and hung as gates, including pintle hinges, stops,hand-made sliding bolts, etc.conforming to Fe 290- Gde E -165 complete all as specified and as directed.
M & L for preparation of new wooden surface of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
M&L for prepartion of old painted of wooden surface of any description , not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint on old wooden painted surface complete all as specified & directed.
M&L for hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe -290 Gde E-165 including embedded porting be painted with bituminus paint. complete all as specified and as directed.
M&L plain cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) in for inserting hold fast of doors & window , bed blocks,fillings & similar work etc. including necessary form work complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregates) as in kerb/benching/copings including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed
M & L for 3mm thick plain sheet glass ordinary quality and glazing with oil putty not exceeding 0.50 Sqm in each pane,complete all as specified and as directed by Engineer-in-Charge .
S&F in repair 20 mm dia Harrison rails, mild steel chromium plated with bracket etc., complete all as specified and as directed by Engr-in-Charge.
S & F in repair brass chromium plated fancy type bracket for curtain rod, suitable for 20 mm dia curtain rod of any approved colour and design complete all as specified and as directed by Engineer-in-Charge.
S & F in repair 18/19mm thick block boards,grade -2 interior grade quality, commercial type for cupboard shutter, shelf, etc, fixed with screws & favicol where required as in cubical desk and cabinets including making holes with decorative covers for wires where ever required fixed to aluminum partition complete all as specified and directed.
S&F in repair 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination for cupboard shutter, shelf, etc fixed with screws & favicol including making holes with decorative covers for wires where ever required fixed complete all as specified and directed.
S&F 100mm long hasp & staple aluminium anodised wire type, including bolt to hinge plate and fixed with screw complete all as specified & directed.
S & F for 30 mm width of flaps (when open) continuous (piano) hinges,mild steel, bright finish or electrogalvanised complete all as specified and directed.
Demolition of brick work of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off from site etc complete all as specified and directed.
M&L for Brick work using Sub class "B" bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed.
Taking down cement or cement lime plaster at any position including raking out joints, hacking for key and scrubbing down with water and removal of rubbish off from site complete all as directed by Engr-in-Charge.
M&L for 15mm thick rendering (in two layer) on stone masonry surfaces or on other than fair face of brick work or concrete surface in cement mortar 1:4, with liquid water proofing compound @ 200 ml/50 kg per bag of cement , finished even and smooth without using extra cement complete all as specified and directed (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ")
M&L for 10mm thick rendering on brick or concrete surface in cement mortar 1:6, finishing surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil emulsion distemper over a coat of primer and a layer of wall care putty (not less than 2.0 mm thick) complete all as specified and directed.
M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces and apply two coats of distemper oil emulsion (OBD) over a coat of primer and a layer of wall care putty (not less than 2.0 mm thick ) complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls/chajja/lintel and applying two coats of cement based paint white or tinted over a coat of alkali resistant primer complete as specified and directed.
M&L for preparation of old decorated surfaces of wall including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with putty and applying two coat of cement base paint on wall surface at any height by applying by pump roller applicator complete all as specified and directed.
M&L for 2.0 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap in roof, walls etc fixed with coach screw with washer or cranked hook bolts etc complete all as specified and directed.
Supply only water proffing compound (ISI) marked
S & F for 600mm (24")stainless steel Turbo ventilator polycarbonate base 600 mm dia shed mounted ,wind driven automatic grade of speed 960 RPM including cutting and fixing of galvalume sheet complete all as specified and directed.
Taking down carefully unserveciable/damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets ,light fittings etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
M&L for point wiring for following point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, wiring with copper conductor cables FRLSH having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked heavy duty not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type GI pressed steel sheet terminal box made out of 1.6mm thick of suitable size,60 mm deep with earth dolly duly ,covered with 2.8 mm thick laminated insulated cover make sheet for mounting fittings/junction boxes for housing/fixing switches etc., complete all as specified and directed. Note: Proper colour coding to be adopted:-
(a) One light / fan/exhaust fan point controlled by one, one way switch.
(b) One 3/5 pin socket outlet 5 Amp on the same board
(c) One 3/5 pin 5 Amps socket outlet on indepandant board.
S & F switch piano flush button single pole one way 5 Amp, complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 05 Amps, universal type complete all as specified and as directed.
S&F Switch socket combination 2 in 1, 3 pin, 5 Amp flush type, universal complete all as specified and as directed.
S & F switch socket combination 2 in 1, 3 pin, 5Amp & 15Amp flush type, universal, complete all as specified and as directed.
Supply and fix ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified.
S&F fan regulator electronic, step type hum free, socket type, suitable for ceiling fans of any capacity, pre wired 230 volts AC 50 HZ supply 100/120 Watt complete all as specified & as directed
M&L for point wiring with FRLSH PVC insulated PVC sheathed electric cable confirming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 2.50 Sq.mm nominal cross sectional area for phase & neutral & including non metallic rigid PVC conduit ISI marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system & 2.50 Sq.mm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including pressed steel anodized sunken boxes 60 mm deep & 1.6 mm thick duly painted inside & anticorrosive outside with Bakelite hylem sheet 2.80 mm thick complete for one six pin switch socket outlet combination ,15 Amps & 3/5 pin socket point on independent board controlled by one ,one way switch complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked) complete all as specified and directed at site.
S & F LED bulb of capacity 10 watt , lumen out put (950)lm ,length 102 mm, dia 56 mm , base cap B22 (ISI mark) three star rated lamp complete with all accessories base all as specified and as directed by Engr-in-Charge.
Taking down existing serveciable tube light fittings /any serveciable LED light fittings of any wattage after disconnecting all necessary electrical connections from ceiling rose to fittings and refixing of the same at existing location including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F LED tube light fitting 1 x 20watt , 220 V, AC, LED batten type tube light surface and wall mounted LED batten PVC housing with polycarbonate diffuserand integrated electronic driver complete with all accessories ,driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engr-in-Charge.
S&F 1X9 W/1X10 W watt LED Bulkhead fitting with IP 65 environmental frendly, ultra modern, energy saving mounted decorative oval bulk head edge lit LED luminaire comprising of high brightness LED 230 Volts AC circuit connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engr-in-Charge.
S&F in repair of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts with suitable amps copper rated busbar & neutral link (ISI mark) 8 way with protection complete all as specified and directed by Engr-in-charge.
S & F in repair amp rating 240V, 10 kA 'B' Curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
S & F in repair amp rating 240V, 10 kA 'B' Curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 5 to 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 16 Sqmm 4.0 core including taking down existing unserveciable cable complete all as specified and directed
S & F in repair sheet metal enclosures (CRCA sheet) dust & vermin proof for DBs when MCBs to be used in tipple pole and neutral (TPN) double door 415 volts, 4 way,vertical type with magnetic locking system including necessary provision for inserting the the DBs in wall & suitable rated amp bus bar and neutral link (ISI marked) complete all as specified and as directed.
S & F in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP 40 to 100 AMP and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
Taking down ceiling fan of any sweep after disconnecting all necessary electrical connctions from ceiling rose to fan complete all as specified and directed.
Labour only for the refixing ceiling fan/exhaust fan after servicing /repairing/overhauling by cleaning/greasing /oiling etc. including provision of connecting ceiling fan/exhaust fan to ceiling rose including three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection and preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove only dust etc. and applying one coat of synthetic enamel (white shade) paint and marking MES number with non erasable marker pen with black colour complete all as specified & directed by Engineer-in-charge.
M & L for Sub main wiring two single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 25 mm dia, complete and and testing on completion including taking down of existing sub main wiring complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of conduit shall be measured as one RM.
Supply and spreading clean, dry, fine river sand for under ground electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Excavation in trenches in soft/loose of soil not exceeding 0.45 metre deep and not exceeding 0.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/ pipes, foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering & well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated soil not exceeding 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supplying & Laying un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
S & F in repair 50mm dia GI pipe light grade for protection of LT UG cables for crossing roads/on wall/poles etc including coupling/ jointing fittings etc.,complete if any all as directed and specified
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts, nuts , check nuts and washers of galvanized iron or steel all as specified and shown in electrical plate No.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate )chamber with RCC 1:2:4 ,type B-1(using 20 mm graded crushed stone aggregate) , 40 mm thick pre cast RCC cover with TMT 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering including taking down of existing earthing complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, returning, filling in and removal etc
Boring of hole under road, pavement, hard standing without disturbing existing surface by using MANUAL hand drill or necessary machine complete all as specified and directed by Engineer-in-Charge. Note :(i) Pipes shall be laid minimum 1.00 mtr below/under existing road surfaces/ apron /floors etc.complete all as specified and as directed. (ii) T&P required for boring to be provided by the bidder at site own arrangement and not any claim entertained on this account at later stage.
M/S Balaji Construction & Company (BID ID -3166242)
M/s Shubham Constructions Co. (BID ID -3161107)
M/S KAMLESHWAR SINGH (BID ID -3164935)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .