REPAIR AND REPLACEMENT OF STREET LIGHT, FLOOD LIGHT, HIGH MAST LIGHT, STREET LIGHT POLES, CABLE AND OTHER CONNECTED WORKS AT ZONE-II UNDER AGE(I) LANSDOWNE
2026_MES_771514_1
87298/LDN/E8
Open Tender
Electrical and Maintenance Works
150 days
AGE (I) Lansdowne
Class E Cat b (i)
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Lansdowne
₹40,000
Yes
11 Jun 2026
11 Jun 2026
14 Jul 2026
11 Jun 2026
6 Jul 2026
30 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches n exc 1.5 m width and n exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n exc 10 sqm on plan and nexc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. | 70.47 | Cum | 26.9 | ₹1,895.64 |
| 2 | Description same all as per item No 1 above but for each additional 1.5m or part thereof in depth beyond the first 1.5m in hard/dense soil complete all as specified and directed. | 0.36 | Cum | 17.9 | ₹6.44 |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed. | 30.9 | Cum | 179.1 | ₹5,534.19 |
| 4 | ìªRemoval of surplus soil to a distance n exc 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.-3¬M&L for sprea | 39.56 | Cum | 53.1 | ₹2,100.64 |
| 5 | river sand in trenches complete all as specified ans as directed.
Note:- Punned thickness shall be considered for payment purpose.öSupply and laying cable protection old size bricks, common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed. ",3¾M&L for PCC (1:4:8) Type D2 (using 40 mm graded aggre-gate) as in foundations, filling and mass-concrete or sub base of floor/ hard standing/ footpath complete all as specified and directed.BMâM&L for PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in coping, roof kerb, cill, bed block, block for insertion of hold fast of door and window with and including formwork complete all as specified and directed.GMXYyDismantling and taking out old unserviceable Tubular poles and struts of any size complete all as specified and directed.ïDisconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 40 mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed.epïDisconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 50 mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed.epDS&F of steel tubular swaged poles complete as per IS-2713 MS base plate of size 300mmx300mmx6mm, final taper plug, bolts, nuts and screws as specified type 410 SP-31(9 mtr long) including painting two coats of aluminium paint over one coat of red oxide primer including 4 Nos band/straps with yellow and black colour in alternate way (250mm wide each) aluminium paint two coat at a distance 300mm from plinth block and marking pole nos with black paint including tarring one coat on steel surface embedded in concrete complete all as specified and directed. Note :- Necessary earth work and excavation, PCC in foundation 1:4:8 type D-2, using 40mm graded stone aggregate and PCC 1:3:6 type C-1, using 20mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50m measured and paid sepearately/4»S&F in repairs/replacement MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10 KA, 'C' Series and making connections with suitable size of copper lugs complete all as specified & directed5B·S&F in repairs/replacement MCB, SPN, AC, 240 volts of 40 Amps capacity 10 KA, 'C' Series and making connections with suitable size of copper lugs complete all as specified & directed7>§Supply and fixing end cap for cable 120 Sqmm three core + 95 Sqmm and one core + 16 Sqmm one core and confirming to relevant IS complete all as specified and directed.$X!Supply and fixing in repairs insulation piercing connectors (IPC) for main/service/street light connections for cable of 16-120 Sqmm with taps ranging from 50-120 Sqmm IPC type 002 complete all as specified and directed and confirming to relevant IS complete all as specified and directed.y¨§Name of Work: REPAIR AND REPLACEMENT OF STREET LIGHT, FLOOD LIGHT, HIGH MAST LIGHT STREET LIGHT POLES CABLE AND OTHER CONNECTED WORKS AT ZONE-II UNDER AGE(I) LANSDOWNEQDismantling Insulators any type any size complete all as specified and directed.~Dismantling stay assembly complete all as specified and directed.( demolition of concrete and excavation measured separately)Each Set¹Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 25 Sqmm 2 core incl taking out old unsv cable from trenches all as specified and as directed. Note :- The earth work, GI pipe & Clamp for suitable size to hold the cable on wall shall be measured and paid separately under appropriate item of Sch AÂÑÁSupply & Fixing stay assembly complete with all accessories, such as stay plate 300x300x6mm, stay rod 215cm long and 16mm dia with nuts including GI Bow turn buckle etc, all as per Electrical Plate No 1 SSR-2009 Part-I complete all as specified and directed. (Necessary excavation and PCC and one set of stay clamps at top of pole & loop insulator of size 90x140mm porcelain, vitreous, white, brown or green shall be measured and paid seperately) ES&F Galvanised stay wire of size 7/4mm all as specified and directed.Qtl¿M&L for loop type insulator porcelain vitreous porcelain white, brown or green large size with overall dimensions 90 x 140 mm clearence of hole 25.5mm complete all as specified and directed.Each Supply and fixing in repairs/replacement of XLPE insulated AB Cable 1100 Volts 3 Core x 120 Sqmm (insulated phase conductors) + 1 x 95 Sqmm (insulated neutral messanger conductor) + 1 x 16 sqmm (insulated conductor for street light connections) ISI marked on 09 mtr LT Steel tubular poles incl refixing of existing serviceable street lights with all required accessories complete all as specified and directed.Supply and fixing in repairs/replacement of XLPE insulated AB Cable 1100 Volts 3 Core x 50 Sqmm (insulated phase conductors) + 1 x 35 Sqmm (insulated neutral messanger conductor) + 1 x 16 sqmm (insulated conductor for street light connections) ISI marked on 09 mtr LT Steel tubular poles incl refixing of existing serviceable street lights with all required accessories complete all as specified and directed.ÅSupply, install and testing in repair LT Feeder pillar panel cubical outdoor type made out of CRCA sheet 3.00mm front hinged openable door including locking arrangement, platform mounted with angle iron 40mmx40mmx5mm frame work suitable for 240 volts grade three phase 4 wire 50 Hz AC Supply system, having bus bar chamber with suitable aluminium bus bar 100 Amp rating and accomodated with 63 Amp MCB TPN, with astronomical digital 24 Hr timer, contactors of 40 Amps rating and making all necessary electrical connection complete, the box shall be dust and vermin proof IP-54 class protection alongwith in built short circuit protection confirms to IS/IEC 60947-4-1 complete all as specified and directed.=Supply, laying and fixing or passing in repairs through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sq mm 2 core complete all as specified and as directed. ÿxSupply & fixing in repairs of Automatic Street Light Control Switch suitable for Single Phase with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is d" 30/60 Lux and for switching OFF e" 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP66. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor and VMS). | 24.3 | Cum | 53.1 | ₹1,290.33 |