| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹6.3 L+₹60,035 (10.4%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder |
Tender Value
₹5.3 L
EMD Value
₹10,580
Closing Date
8 Jun 2022, 6:00 pmClosed
AGE I R AND D MANALI
AGE I R AND D MANALI PIN 175103
PROVISION OF COMPUTER ROOM FOR AEBAS SYSTEM AT DGRE RDC MANALI.
2022_MES_517603_2
AGE(I)/MNL-02/2022-23
Open Tender
Civil Works
Item Rate
240 days
DGRE RDC MANALI
Refer NIT and Tender Documents
5 documents required · 5 mandatory
₹500
AGE I R AND D MANALI
₹10,580
Yes
20 Jun 2022
19 May 2022
10 Jun 2022
19 May 2022
8 Jun 2022
26 May 2022
Amount
Demolition of concrete in ground floors and pavings n.exc. 15 cm thickness (below or above ground level).complete all as specified & directed by Engineer-in -charge.
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in hard/dense soil complete all as specified and directed by Engineer-In- Charge.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed by Engineer-In- Charge.
Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil complete all as specified and directed by Engineer-In- Charge.
M & L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation/pcc bed or mass concrete etc complete all as specified and directed by Engineer-In- Charge.
M&L for 75mm thick cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection finished even and fair without using extra cement complete all as specified and directed by Engineer-In- Charge.
M&L for hardcore or gauge of broken stone or boulders n.exc 63mm, deposited spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface.complete all as specified and directed by Engineer-In- Charge.
M&L for formwork flat, rough finished surface of concrete for side of footing columns, plinth beams or similar work including any types of supports/scafoldings etc all as specified and directed by Engineer -in-charge.
M&L for formwork to sides of pillars, posts, struts, piers columns and stanchions complete all as specified and directed by Engineer-In- Charge.
M&L for form work sides and soffits of floor or roof beam, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc. complete all as specified and directed by Engineer-In- Charge.
M&L for RCC design mix (M-25 ) using 20mm graded stone aggregate for foundation footings, plinth beams, columns up to GL etc all as specified and directed by Engineer -in- Charge. Note : Reinforcement shall be measured and paid seperately under relevant item.
M&L for RCC Design mix (M-25) using 20mm graded stone aggregate in columns, pillars, piers, post and struts complete all as specified and directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid seperately under relevant items.
M&L for RCC Design mix (M-25) using 20mm graded stone aggregate in in beams, cantilevers, bressummers, lintel over 1.5m span complete all as specified and directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid seperately under relevant items.
M & L for 10 mm dia and over TMT bars cut to length bent to shape as required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-In- Charge.
Ditto all as per item No.14 above but 6 to 8mm dia round bars as in stirrups.complete all as specified and directed by Engineer-In- Charge.
M&L for Pre-cast cement concrete block 1:3:6 type C1 (using 20mm graded aggregate) masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed by Engineer-In- Charge.
M & L for rendering 15 mm thick in CM 1 : 4 on any faces of stone masonry or concrete block surfaces,finished even and smooth without using extra cement complete all as specified and directed by Engineer-In- Charge
Supply only integral water proofing compound.
M & L for rendering 15 mm thick on brick work or concrete surface other than fair face of brick work in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed by Engineer-In- Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) over a coat of wall care putty complete all as specified and directed by Engineer-In- Charge.
M & L for Preparation of newly plastered wall surfaces and applying two coasts of cement base paint. complete all as specified and directed by Engineer-In- Charge.
S&F for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment similar work as rest plates of truss and trench cable cover etc conforming to FE-410W, Gde E-250 Quality 'A' complete all as specified and directed by Engineer-In- Charge.
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., Fe 410 -W (GdeE- 250) quality-A, complete all as specified and directed by Engineer-In- Charge.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying 2 coats of Synthetic enamel paint over a coat of red oxide primer, all as specified and directed by Engr-in-Charge.
S&F ,coloured pre-painted GALVALUME aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strngth of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws including necessary washers etc all as per manufactures instruction complete all as specified and directed by Engineer-In- Charge.
Ditto all as per item No.25 above but coloured metal roofing sheet as in ridge all as manufacturers instruction and complete all as specified and directed by Engineer-In- Charge.
M&L for 100 mm thick PCC type C2 1:3:6 (40 mm graded stone aggr)in sub base, floor.complete all as specified and directed by Engineer-In- Charge.
M&L for providing cement concrete 1:2:4 type B0 as in mud stops rounded or chamfered complete all as specified and directed by Engineer-In- Charge.
M&L for 20mm thick screed bed or bedding layer in cement mortar 1:6 for laying of floor tiles complete all as specified and directed by Engr-in-Charge.
M&L for non skid coloured cereamic tiles 7 to 8mm thick (square/rectangular) area of each tiles exc. 0.11 Sqm but n.exc. 0.18 Sqm in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge.
S&F for Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer-In- Charge.
S&F, 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 putty or wdn beading in each pane including painting / oiling to new putty to match with the new surfaces, complete all as specified and directed by Engineer-In- Charge.
S&F, anodised aluminium snap grid frame work of grid size 605X605mm for false ceiling complete all as specified and directed by Engineer-In- Charge.
S&F, hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI glat 40x3mm size 60mm long complete all as specified and directed by Engr-in-Charge.
M&L for providing and fixing 12mm thick perforated particle board/tiles for insulation and accoustic purposes, 60cmx60cm in size fixed in ceiling (flat or sloping) with nails to timber frame work or with staples on snap grid complete all as specified and directed by Engr-in-Charge.
S&F for pressed steel frame of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified and directed by Engr-in-Charge.
S&F, plain framed pannelead shutters (any No of panels) with panel of timber flat on both sides of 2nd class hard wood 30mm thick complete all as specified and directed by Engr-in-Charge.
M&L for preparation of wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engr-in-Charge.
S&F, mild steel butt hinges medium wight cold rolled 100mm size complete all as specified and directed by Engineer-In- Charge.
S&F, Aluminium handles, cast type anodised 150mm size complete all as specified and directed by Engineer-In- Charge.
S&F, Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy.complete all as specified and directed by Engineer-In- Charge.
S&F, Aluminium, anodised, barrel tower bolts 150mm long of extruded section complete all as specified and directed by Engineer-In- Charge.
S&F, cast iron body Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width & of weight between 61 to 80kg.complete all as specified and directed by Engineer-In- Charge.
S&F, 140mm long Floor door stopper of aluminium alloy body & tongue, anodised, with hard drawn steel spring.complete all as specified and directed by Engineer-In- Charge.
M&L for Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified MAKE OF CABLE - Standard / PLAZA / HAVELLS & MAKE OF PVC CASING/CAPING - PRICISION/PRESSFIT/MODI complete all as specified and directed by Engineer-In- Charge.Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
(a) One light point controlled by one, one way switch
(b) One 3 pin 5 amp socket out point on the same board with other switches.
(c) One 3 pin 5 amps socket out let point on independent board
All as per same in item No 45 above but for one socket outlet 15 amp on independent board with 2.5 Sq. mm cable and 1.5 Sq.mm. earth wire.complete all as specified and directed by Engineer-In- Charge.
S &F, Switch piano flush type single pole one way 5 amps.complete all as specified and directed by Engineer-In- Charge.
S &F, Socket out let 2 in one, 5/3 pin 5Amp complete all as specified and directed by Engineer-In- Charge.
S &F, Switch socket combination 5 Amps 5 pin flush type complete all as specified and directed by Engineer-In- Charge.
S &F, Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal .complete all as specified and directed by Engineer-In- Charge.
S &F, Ceiling rose, surface bakelite 65x50 mm three terminal complete all as specified and directed by Engineer-In- Charge.
S &F, Lamp holder insulated body with back plate for angle holder with 7W LED lamp of make as specified by Engr-in-Charge . Notes for Item ser No 47 to 52 Make - Anchoor/Standard/Havells
S & F, 1x 18 watt universal batten for T5 and T8 lamps as regal batten for LED tube.complete all as specified and directed by Engineer-In- Charge. Make Havells Cat No: REGALBATTENT 5UPTO1X22WDSBSWH other then Eqvt Bajaj/CG
S & F, Ultra bright glass 18W LED tubelight with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders as crystal glass LED Tubelight (Double Side Connection). complete all as specified and directed by Engineer-In- Charge.Make Havells Cat No: CRYSTAL 1213T8DSTL18WLED865SGLASS other then Eqvt Bajaj CG
S &F, LED street Light/security light fitting, 35 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as specified and as directed by the Engineer-in-charge. Make- Philips/ Crompton/ C&S
supply & fixing of GI pipe bracket up to 40 mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 1x15 w LED security light fitting complete all as specified and directed by Engineer-In- Charge.
S&F, Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 8 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed. Make : Havells/lEGRAND/SSK .NOTE FOR ITEM NO 13 -(1).The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall.// DB to be fixed on wall including frame made out of MS flat 40x5mm (2).The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface (3) MAKE OF DB & MCB - LEGRAND/ABB/L&T (4) (note - rate is inclusive of cutting chases & flush to wall & making good to the disturbed surfaces of walls etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes making good disturbed surfaces of walls, etc )
S&F, MCB single pole and neutral, 240 Volts , 32-40 Amps complete all as specified and directed by Engineer-In- Charge. Make : Havells/Legrand/Philips
S&F, MCB singal pole 240 Volts , 6 to 40 Amps complete all as specified and directed by Engineer-In- Charge. Make : Havells/Legrand/Philips
M & L for Aluminum Unarmoured service cable PVC insulated and PVC sheathed of size 10 Sqmm three core. balance stranded conductor, XLPE Insulated, cores laid up,PVC tape/ Extruded Innersheathed for Multicore Cables, Unarmoured, extruded PVC Type ST2 sheathed, 650/1100V grade as per ISded PVC Type ST2 sheathed, 650/1100V grade as per IS 7098(Part 1) 1988 complete all as specified and directed by Engineer-in-Charge.Make: Polycab or equivalent.
NATHU RAM AND SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .