Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 CrAccepted-AOC ERNAKULAM KERALA 682301 INDIA | ERNAKULAM | KERALA | 682301 | ₹5.5 Cr Quoted ₹5.9 Cr | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical does not meet pre qualification criteria |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
20 Jun 2023, 1:00 pmClosed
HOD (TSP)
HOD (TSP) TSP Unit, KMML, Chavara
Supply erection testing and commissioning of electrics for magnesium recycling plant (MRP) project at TSP
2023_KMML_576348_1
TSP/PROJ/MRP/ELECTRICAL/PKG14
Open Tender
Electrical Works
Supply and Service
210 days
TSP Unit, KMML, Chavara
See tender details
5 documents required · 5 mandatory
₹29,500
₹2 L
TSP Unit, KMML, Chavara
31 Oct 2023
15 May 2023
22 Jun 2023
15 May 2023
20 Jun 2023
15 May 2023
30 May 2023
Electrics for Magnesium Recycling Plant (MRP) Project
Supply of 1600 kVA, 6.6kV/433V, Dyn11, Three phase, 50Hz,Oil Cooled Transformer complete with all accessories as per specification and data sheet (8165-13-DA-903 01) attached.
Erection, testing and commissioning of 1600 kVA, 6.6kV/433V, Dyn11, Three phase, 50Hz,Oil Cooled Transformer complete with all accessories as per specification and data sheet (8165-13-DA-903 01) attached.
Supply of 6.6KV, 1250A, 20kA , vacuum circuit breaker switchboard complete with all accessories as per the specifications data sheets(8165-13-DA-90301) and drawings attached
Erection testing and commissioning of 6.6KV, 1250A, 20kA , vacuum circuit breaker switchboard complete with all accessories as per the specifications data sheets(8165-13-DA-90301) and drawings attached
Supply of 6.6KV, 1250A, 20kA single panel, vacuum circuit breaker switchboard complete with all accessories as per the specifications data sheets(8165-13-DA-90301) and drawings attached. This panel shall be the extension of existing 6.6kV Switchboard at the substation.
Erection testing and commissioning of 6.6KV, 1250A, 20kA single panel, vacuum circuit breaker switchboard complete with all accessories as per the specifications data sheets(8165-13-DA-90301) and drawings attached. This panel shall be the extension of existing 6.6kV Switchboard at the substation. Interconnection of busbar and all other control wiring to the existing switchboard shall also be done
Supply of Main Switch Board (MSB) 433 V, 2500 A, 35MVA (50kA) Single front,draw out type complete with all accessories as per the specifications, and data sheets attached.( 8165-13-DA-90601)(Cable entry-Top)
Erection testing and commissioning of of Main Switch Board (MSB) 433 V, 2500 A, 35MVA (50kA) Single front,draw out type complete with all accessories as per the specifications, and data sheets attached.( 8165-13-DA-90601)(Cable entry-Top)
Supply of Emergency Switch Board (ESB) 433 V, 1000 A, 35MVA (50kA) Single front,draw out type complete with all accessories as per the specifications, and data sheets attached.( 8165-13-DA-90601)(Cable entry-Top)
Erection testing and commissioning of Emergency Switch Board (ESB) 433 V, 1000 A, 35MVA (50kA) Single front,draw out type complete with all accessories as per the specifications, and data sheets attached. Scope of work shall also include setting up of relays in the existing AMF panel for executing the proper changeover system( 8165-13-DA-90601)(Cable entry-Top)
Supply of Auxiliary Switch Board (ASB) 433 V, 400 A, 35MVA (50kA) Single front,draw out type complete with all accessories as per the specifications, and data sheets attached.( 8165-13-DA-90602)(Cable entry-Top)
Erection testing and commissioning of Auxiliary Switch Board (ASB) 433 V, 400 A, 35MVA (50kA) Single front,draw out type complete with all accessories as per the specifications, and data sheets attached.( 8165-13-DA-90602)(Cable entry-Top)
Supply of Motor Control Centre (MCC) 433 V, 200 A, 35MVA (50kA) Single front,draw out type complete with all accessories as per the specifications, and data sheets attached.( 8165-13-DA-90602)(Cable entry-Top)
Erection testing and commissioning of Motor Control Centre (MCC) 433 V, 200 A, 35MVA (50kA) Single front,draw out type complete with all accessories as per the specifications, and data sheets attached.( 8165-13-DA-90602)(Cable entry-Top)
Supply of 5 kVA, 415 V three phase AC, parallel redundant Uninterruptible Power Supply (UPS) system with sealed maintenance free VRLA battery, rectifier cum chargers, inverters, ACDB etc and all other accessories conforming to the attached specifications/datasheet. Price quoted shall include supply of spares as per spares list attached.
Erection testing and commissioning of 5kVA UPS
Supply of 415V,160A, 3phase and neutral,4Way Vertical distribution board( For lighting DBs) with 1no.160A MCCB with integrated ELCB as incomer feeder and 4 Nos.32A TPN C curve MCBs, as outgoing feeders complete with all accessories as per the specifications and drawings attached. DB shall be As per IEC 61439-3 With 160 A Copper Busbar for each phase . The DB shall have separate buses for phase, neutral and earth. The DB shall be double door type and suitable for cable entry .The earth bus shall be suitable for taking individual earth leads for each circuit. The enclosure shall have IP43 protection. The gaskets used if any, shall be of neoprene only. Spare slots provided for MCB mounting if any shall be properly blanked.DB shall be surface mounting type.
Erection of 415V,160A, 3phase and neutral,4Way Vertical distribution board( For lighting DBs) Item 17
Supply of 415V,160A, 3phase and neutral,6Way Vertical distribution board( For ASB-2) with 1no.160A MCCB with integrated ELCB as incomer feeder and 6 Nos.32A TPN C curve MCBs, as outgoing feeders complete with all accessories as per the specifications and drawings attached. DB shall be As per IEC 61439-3 With 160 A Copper Busbar for each phase . The DB shall have separate buses for phase, neutral and earth. The DB shall be double door type and suitable for cable entry .The earth bus shall be suitable for taking individual earth leads for each circuit. The enclosure shall have IP43 protection. The gaskets used if any, shall be of neoprene only. Spare slots provided for MCB mounting if any shall be properly blanked.DB shall be surface mounting type.
Erection of 415V,160A, 3phase and neutral,6Way Vertical distribution board( For ASB-2)
Supply of 415V, 3 Ph & N, 6WAY Power Distribution Boards (for PDB-1) with one number 63 A, 4 pole MCB and ELCB (30mA) as incomer side and 18 No 20A Single Pole MCBs as out going feeders. The DB shall have separate buses for phases, neutral and earth. The DB shall be double door type and suitable for conduit entry for outgoing and cable entry for incoming. (All MCBs shall be of C curve and 10 kA short circuit capacity. DBs shall conform to IS 13032 and Bus bar rating shall be 100A minimum).The earth bus shall be suitable for taking individual earth leads for each circuit. The DB shall be suitable for surface mounting on a wall unless otherwise indicated in the layout drawing. The enclosure shall have IP43 protection. The gaskets used if any, shall be of neoprene only. Spare slots provided for MCB mounting if any shall be properly blanked.
Erection of 415V, 3 Ph & N, 6WAY Power Distribution Boards (for PDB-1 )
Supply of 415V, 3 Ph & N, 4WAY Power Distribution Boards (for PDB-2 &3) with one number 63 A, 4 pole MCB and ELCB (30mA) as incomer side and 12 No 20A Single Pole MCBs as out going feeders. The DB shall have separate buses for phases, neutral and earth. The DB shall be double door type and suitable for conduit entry for outgoing and cable entry for incoming. (All MCBs shall be of C curve and 10 kA short circuit capacity. DBs shall conform to IS 13032 and Bus bar rating shall be 100A minimum).The earth bus shall be suitable for taking individual earth leads for each circuit. The DB shall be suitable for surface mounting on a wall unless otherwise indicated in the layout drawing. The enclosure shall have IP43 protection. The gaskets used if any, shall be of neoprene only. Spare slots provided for MCB mounting if any shall be properly blanked.
Erection of 415V, 3 Ph & N, 4WAY Power Distribution Boards (for PDB-2 &3)
Supply of 415V, 3 Ph & N, 6WAYLighting Distribution Board (for LDB-1 &2) with one number 32 A, 4 pole MCB and ELCB (30mA) as incomer side and 18 No 10A Single Pole MCBs as out going feeders. The DB shall have separate buses for phases, neutral and earth. The DB shall be double door type and suitable for conduit entry for outgoing and cable entry for incoming. (All MCBs shall be of C curve and 10 kA short circuit capacity. DBs shall conform to IS 13032 and Bus bar rating shall be 100A minimum).The earth bus shall be suitable for taking individual earth leads for each circuit. The DB shall be suitable for surface mounting on a wall unless otherwise indicated in the layout drawing. The enclosure shall have IP43 protection. The gaskets used if any, shall be of neoprene only. Spare slots provided for MCB mounting if any shall be properly blanked.
Erection of 415V, 3 Ph & N, 6WAYLighting Distribution Board (for LDB-1 &2)
Supply of 230V, 1 Ph & N Lighting Distribution Board-3 (LDB-3 ) with one number 32 A 2 pole MCB and ELCB (30mA) as incomer side and 12 Nos 10A Single Pole MCBs as out going feeders. The DB shall have separate buses for phase, neutral and earth. The DB shall be double door type and suitable for conduit entry for outgoing and cable entry for incoming. (All MCBs shall be of C curve and 10 kA short circuit capacity. DBs shall conform to IS 13032 ).The earth bus shall be suitable for taking individual earth leads for each circuit. The DB shall be suitable for surface mounting on a wall unless otherwise indicated in the layout drawing. The enclosure shall have IP43 protection. The gaskets used if any, shall be of neoprene only. Spare slots provided for MCB mounting if any shall be properly blanked.
Erection of 230V, 1 Ph & N Lighting Distribution Board-3 (LDB-3 )
Design and Supply of 2500 Amps. 415 volts, 50 Hz. Four pole (50 KA for 1 sec.) Sandwich construction bus duct, aluminum bus bars insulated with 50% neutral earth bus, expansion joints, Flange End, Adaptor Box, Copper Flexible with support hangers including 90-degree bends etc. as per specifications The length indicated is the approximate/ estimated centre line length from transformer flange to PMCC flange, including bend, flexible etc.).Contractor shall measure actual length /route at site prior to manufacture and supplied as per actual installation requirement at site
Installation, Testing & Commissioning of 2500 Amps. 415 volts, 50 Hz. Four pole (50 KA for 1 sec.) Sandwich construction bus duct, aluminum bus bars
Supply of ETP grade Copper Bus bar of rating 30V, 10000A, between Transformer Rectifier unit and Multipolar cell. Dimensions of the bus shall be 100mmx10mm with 8Nos connected in parallel with sand which type connection. The scope of supply shall be complete with all accessories such as of main run including bends as required. Bus bars shall be supported using insulators.Supply shall be for individual bus trunkings identified. Supply of structural steel items are covered elsewhere. The length indicated is the approximate/ estimated centre line length from transformer flange to MP Cell Terminal, including bend, flexible etc.).Contractor shall measure actual length /route at site prior to manufacture and supplied as per actual installation requirement at site. Vendor of copper bus bars shall have ISO certification.
Erection of Bus trunking - 30V, 10000A, DC Copper bus trunking between Transformer Rectifier unit and Multipolar cell
Supply of ETP grade Copper Bus bar of rating 50V, 2500A, between Thyristor controlled transformer unit and Electrolytic zone , Thyristor controlled transformer unit and Magnesium chloride furnace Dimensions of the bus shall be 100mmx10mm with 2Nos connected in parallel with sand which type connection. The scope of supply shall be complete with all accessories such as of main run including bends as required. Bus bars shall be supported using insulators .Supply shall be for individual bus trunkings identified. The length indicated is the approximate/ estimated centre line length from transformer flange to MP Cell Terminal, including bend, flexible etc.).Contractor shall measure actual length /route at site prior to manufacture and supplied as per actual installation requirement at site. Supply of structural steel items are covered elsewhere.Vendor of copper bus bars shall have ISO certification.
Erection of Bus trunking - 50V, 2500A, 2 Phase Copper bus trunking between Thyristor controlled transformer unit and Electrolytic zone , Thyristor controlled transformer unit and Magnesium chloride furnace
Supply of ETP grade Copper Bus bar of rating 50V, 5000A, between Thyristor controlled transformer unit and Non Electrolytic zone .Dimensions of the bus shall be 100mmx10mm with 4Nos connected in parallel with sand which type connection. The scope of supply shall be complete with all accessories such as of main run including bends as required. Bus bars shall be supported using insulators Supply shall be for individual bus trunkings identified. Supply of structural steel items are covered elsewhere. The length indicated is the approximate/ estimated centre line length from transformer flange to MP Cell Terminal, including bend, flexible etc.).Contractor shall measure actual length /route at site prior to manufacture and supplied as per actual installation requirement at site.Vendor of copper bus bars shall have ISO certification.
Erection of Bus trunking - 50V, 5000A, 2 Phase Copper bus trunking between Thyristor controlled transformer unit and Non Electrolytic zone ,
Supply of 100mm x 10mm x 450mm size flexible copper connection. Length shall be excluding of fusion welded part
Erection of 100mm x 10mm x 450mm size flexible copper connection.
Erection of of thyristor based water-cooled rectifier transformer system 30V/10KA DC, including Rectifier, transformer, Panels, cooling system , plate heat exchanger and all related accessories. Scope of work shall also include testing and commissioning of the TR Unit in co ordination with the supplier of the Unit.
Erection testing and commissioning of (i) Thyristor unit to regulate 3 phase to 3 phase output voltage and (ii) a step down transformer of 2 phase 50 Volts (max), 2500 A (max), 50 Hz as output and 3 Phase, 0-415V, 50 Hz supply as input. Power cum control panel, breaker control for incoming and outgoing of transformer, Oil required for cooling of step down transformer and all accessories. Commissioning of the unit shall be done in co ordination with the supplier of the unit.
Erection testing and commissioning of (i) Thyristor unit to regulate 3 phase to 3 phase output voltage and (ii) a step down transformer of 2 phase 50 Volts (max), 5000 A (max), 50 Hz as output and 3 Phase, 0-415V, 50 Hz supply as input. Power cum control panel, breaker control for incoming and outgoing of transformer, Oil required for cooling of step down transformer and all accessories. Commissioning of the unit shall be done in co ordination with the supplier of the unit
Erection testing and commissioning of 415 V, 3 Phase Capacitor control panel with 160 kVAR Capacitor bank with 400 A MCCB as incomer , APFC Relay and all accessories .Commissioning of the unit shall be done in co ordination with the supplier of the Panel
Supply of 110V,177AH, SMF type Battery system comprising battery,battery mounting frame,float cum boost charger,standby float cum boost charger,distribution board etc.(8165-13-DA-90701)
Erection of of 110V,177AH, SMF type Battery system comprising battery,battery mounting frame,float cum boost charger,standby float cum boost charger,distribution board etc.(8165-13-DA-90701)
Supply of 2 TON Split Type AC Unit with Voltage stabiliser of suitable capacity with BEE 5 star rating
Erection of 2 TON Split Type AC Unit with Voltage stabiliser of suitable capacity with BEE 5 star rating
Erection of 3.8/6.6kV(E), XLPE insulated, PVC sheathed round wire armoured Aluminium cable of 3Cx300Sq.mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 4Cx400 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 4Cx400 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx400 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx400 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx300 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx300 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx240 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx240 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx185 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx185 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx95 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx95 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx70 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Aluminium cable 3.5Cx70 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 3Cx10sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 3Cx10 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 4Cx6sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 4Cx6 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 3Cx4sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 3Cx4 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 3Cx6sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 3Cx6 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 3Cx2.5sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 3Cx2.5 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 7Cx2.5sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 7Cx2.5 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 10Cx2.5sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 10Cx2.5 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 5Cx2.5sq. mm. Refer sl no. 2 of Annexure for further requirement.
Erection of of 650/1100V, XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed Copper cable 5Cx2.5 sq. mm. Refer sl no. 2 of Annexure for further requirement.
Supply of High Voltage End termination kits (heat shrinkable type) complete with all accessories and materials suitable for 3.8kV/6.6kV(E) Aluminium conductor XLPE insulated, armoured PVC sheathed, power cables 3Cx300 sq mm required for termination at MSDS switchboard, HT SB and Transformer
Erection of High Voltage End termination kits (heat shrinkable type) complete with all accessories and materials suitable for 3.8kV/6.6kV(E) Aluminium conductor XLPE insulated, armoured PVC sheathed, power cables 3Cx300 sq mm required for termination at MSDS switchboard, HT SB and Transformer
Supply of heat shrinkable type straight through joints on main run of 3.8kV/6.6kV(E), Aluminium conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable 3C x 300 sq.mm powercables conforming to specifications, data sheets, drawing, relevant standards etc. to the entire satisfaction of the owner. The scope shall include supply of required accessories and preparation of joints as per manufacturer's recommendation. The scope shall also include disconnection of cables from switch board/equipment, identification of cables etc. as required for the successful completion of job.
Installation, testing and commissioning of heat shrinkable type straight through joints on main run of 3.8kV/6.6kV(E), Aluminium conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable 3C x 300 sq.mm power cables
Termination of 4Cx400 Sq.mm 650/1100V A2XFY cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 3.5Cx400 Sq.mm 650/1100V A2XFY cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 3.5Cx300 Sq.mm 650/1100V A2XFY cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 3.5Cx240Sq.mm 650/1100V A2XFY cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 3.5Cx185Sq.mm 650/1100V A2XFY cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type tinned cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 3.5Cx95Sq.mm 650/1100V A2XFY cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type tinned cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 3.5Cx70Sq.mm 650/1100V A2XFY cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 3Cx10Sq.mm 650/1100V XLPE Insulated armoured copper cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type tinned cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 4Cx6Sq.mm 650/1100V XLPE Insulated armoured copper cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type tinned cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 3Cx6Sq.mm 650/1100V XLPE Insulated armoured copper cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type tinned cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 3Cx4Sq.mm 650/1100V XLPE Insulated armoured copper cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 3Cx2.5Sq.mm 650/1100V XLPE Insulated armoured copper cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 7Cx2.5Sq.mm 650/1100V XLPE Insulated armoured copper cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 10Cx2.5Sq.mm 650/1100V XLPE Insulated armoured copper cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping type cable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Termination of 5Cx2.5Sq.mm 650/1100V XLPE Insulated armoured copper cable on panels, on safe area (ordinary) / flame proof motors and Junction boxes, FLP local control stations etc., testing, commissioning and handing over of power cables, conforming to specifications, data sheets, drawings, relevant Indian Standards, code of practices etc. to the entire satisfaction of the owner and of the following sizes. The scope shall include making cable entries on gland plates on equipment, wherever required, fixing lugs, electrical connections, cable glanding (where applicable) and gland earthing. The scope shall also included supply and installation of all required accessories such as, crimping typecable lugs, bolts, nuts, washers, ferrules, gland earth clamps, strips etc. (The cable termination rate shall include gland earthing also). The scope shall also include supply of double compression Nickel plated brass cable glands also. The gland shall be suitable for cable entries with ET / NPT threads as required. The contractor shall verify the entry thread, type of enclosure (hazardous/ non hazardous) etc., to find out the actual type of cable gland required.
Supply of heat shrinkable type straight through joints on main run of 650V/11000V, Aluminium conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable 3.5C x 400 sq.mm powercables conforming to specifications, data sheets, drawing, relevant standards etc. to the entire satisfaction of the owner. The scope shall include supply of required accessories and preparation of joints as per manufacturer's recommendation. The scope shall also include disconnection of cables from switch board/equipment, identification of cables etc. as required for the successful completion of job.
Installation, testing and commissioning of heat shrinkable type straight through joints on main run of 650V/11000V, Aluminium conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable 3.5C x 400 sq.mm power cables conforming to specifications, data sheets drawing, relevant standards etc. to the entire satisfaction of the owner. The scope shall include supply of required accessories and preparation of joints as per manufacturer's recommendation. The scope shall also include disconnection of cables from switch board/equipment, identification of cables etc. as required for the successful completion of job.
Disconnecting and dismantling of existing 3.5Cx400Sq.mm Al. cables from cable trays/trenches as directed by the site in charge.
Supply of CI plate electrode earth pits as per Drg. No. 8165-13-GE- 00 251. The scope shall include excavation with shuttering if required, dewatering the excavated pit if required, refilling with charcoal & sand, construction of inspection chamber with cover slab, etc. The supply scope shall include supply of electrodes, GI pipes, earth conductors and funnel and all other accessories required. The scope shall also include supply of all accessories such as sand, reinforcement steel, brick, rubble, PVC pipes, clamps, bolts, nuts, washers, bitumen compound, etc. For general requirements refer Annexure.
Erection, Testing, Commissioning and Handing over of CI plate electrode earth pits as per Drg. No.8165-13-GE- 00 251 The scope shall include excavation with shuttering if required, dewatering the excavated pit if required, refilling with charcoal & sand, construction of inspection chamber with cover slab, etc. Scope shall also include numbering of the pit with paint
Supply of pipe electrode earth pits as per Drg No.8165-13-GE-00 254. The scope shall include excavation with shuttering if required, dewatering the excavated pit if required, refilling with charcoal & sand, construction of inspection chamber with cover slab, etc. The supply scope shall include supply of electrodes, GI pipes, earth conductors and funnel and all other accessories required. The scope shall also include supply of all accessories such as sand, reinforcement steel, brick, rubble, PVC pipes, clamps, bolts, nuts, washers, bitumen compound, etc. For general requirements refer Annexure.
Erection, Testing, Commissioning and Handing over of pipe electrode earth pits as per Drg No.8165-13-GE-00 254.
Supply of Hot dip galvanized 25x6 GI Earth strip for providing Lightning protection of buildings.The rates shall be inclusive of hardware required for welding and bolting.
Erection of Hot dip galvanized 25x6 GI Earth strip
Supply of Hot dip galvanized 32x6 GI Earth strip for providing Lightning protection of buildings.The rates shall be inclusive of hardware required for welding and bolting.
Erection of Hot dip galvanized 32x6 GI Earth strip
Supply of 50x6 Copper Earth strip for providing earthing for transformer, HT switchboards, MSB, ESB and interconnection of earth pits.The rates shall be inclusive of hardware required for welding and bolting.
Erection of 50x6 copper Earth strip
Supply of PVC covered Aluminium conductors of size 95sq.mm, for earthing of ASB, MCC and Battery charger
Erection of PVC covered Aluminium conductors of size 95 sq.mm
Supply of PVC covered Aluminium conductors of size 16sq.mm, for earthing of LDB, PDB, Motors,control panels, LCS etc.
Erection of PVC covered Aluminium conductors of size 16 sq.mm
Supply of Test joint made of 25mmx6 mm GI strip 125mm long with 4Nos.GI bolts,nuts,check nuts ,spring washer etc
Erection of Test joint made of 25mmx6 mm GI strip 125mm long with 4Nos.GI bolts,nuts,check nuts ,spring washer etc
Supply of 100 mm wide, 6mm thick Aluminium junction plate of various lengths suitable for connecting required number of earth conductors. The scope includes cutting to required sizes and fixing the junction plate on walls/racks/supports, etc. as well as punching of boltholes. For general requirements refer Annexure. Also refer Drg. No. 8165-13-GE-00 254.
Erection of 100 mm wide, 6mm thick Aluminium junction plate of various lengths
Supply and fabrication of structural steel items as per drawings enclosed for racks, risers and tray supports, pedestals, supports for other equipment, etc. as required. The painting shall be with two coats of epoxy paint over 2 coats of suitable epoxy primer. The scope of work shall be as noted below. The supply scope shall include supply of MS steel sections of various sizes as required. For other requirements see Annexure.
Erection, fixing, epoxy painting and handing over of structural steel items as per drawings enclosed for racks, risers and tray supports, pedestals, supports for other equipment, etc. as required. The painting shall be with two coats of epoxy paint over 2 coats of suitable epoxy primer. The scope of work shall be as noted below. The erection scope shall include transportation, handling at site, storage, inspection, safe custody, welding, cutting, making bolt holes, and painting with two coats of epoxy paint over 2 coats of suitable epoxy primer after cleaning with wire brush including supply of paint, etc. Chipping, cement grouting, re-plastering of walls, floors, ceilings, columns etc. of concrete or brick work for supporting the structural items, supply of structural items, bolts, nuts, washers, cement, sand, etc. are also included in the scope of the work. The bolts, nut, washers shall be of hot dipped GI. The rate indicated below shall be applicable also for structural if any issued by PURCHASER. The concrete footing for supports shall be extra under separate item as indicated elsewhere. Payment shall be made on the basis of measurement of dimensions of structural steel items actually installed multiplied by the unit weight applicable for various sections. The quantities indicated being of preliminary nature, contractor shall assess the actual site requirement and supply accordingly.
Supply of 750mm wide size Pultruded ladder type GRP/FRP cable trays, with 4mm thick, 100mm side runner, 3000 mm long, complete with bends, SS tray couplers and SS hardware viz bolts/nuts/washers, etc. as per drawings enclosed. The scope of work shall be as noted below; The scope shall include supply of bends, tees, jointing plates, bolts, nuts, washers, etc as required. However for measurement, no separate charges shall be applicable for required bends, Tees, jointing plate etc. Refer Annexure for general requirement.
Erection of 750mm wide size Pultruded ladder type GRP/FRP cable trays, with 4mm thick, 100mm side runner, 3000 mm long, complete with bends, SS tray couplers and SS hardware viz bolts/nuts/washers, etc. as per drawings enclosed. The scope of work shall be as noted below; The erection scope shall include transportation, handling at site, storage, inspection, safe custody, fixing to structural supports, jointing wherever required, etc. The GRP trays are to be laid over fabricated MS cable racks. The scope shall also include, supply of bolts, nuts, clamps, washers, etc. The bolts, nut, washers shall be of SS.
Supply of 450mm wide size Pultruded ladder type GRP/FRP cable trays, with 4mm thick, 100mm side runner, 3000 mm long, complete with bends, SS tray couplers and SS hardware viz bolts/nuts/washers, etc. as per drawings enclosed. The scope of work shall be as noted below; The scope shall include supply of bends, tees, jointing plates, bolts, nuts, washers, etc as required. However for measurement, no separate charges shall be applicable for required bends, Tees, jointing plate etc. Refer Annexure for general requirement.
Erection of 450mm wide size Pultruded ladder type GRP/FRP cable trays, with 4mm thick, 100mm side runner, 3000 mm long, complete with bends, SS tray couplers and SS hardware viz bolts/nuts/washers, etc. as per drawings enclosed. The scope of work shall be as noted below; The erection scope shall include transportation, handling at site, storage, inspection, safe custody, fixing to structural supports, jointing wherever required, etc. The GRP trays are to be laid over fabricated MS cable racks. The scope shall also include, supply of bolts, nuts, clamps, washers, etc. The bolts, nut, washers shall be of SS.
Supply of 300mm wide size Pultruded ladder type GRP/FRP cable trays, with 4mm thick, 100mm side runner, 3000 mm long, complete with bends, SS tray couplers and SS hardware viz bolts/nuts/washers, etc. as per drawings enclosed. The scope of work shall be as noted below; The scope shall include supply of bends, tees, jointing plates, bolts, nuts, washers, etc as required. However for measurement, no separate charges shall be applicable for required bends, Tees, jointing plate etc. Refer Annexure for general requirement.
Erection of 300mm wide size Pultruded ladder type GRP/FRP cable trays, with 4mm thick, 100mm side runner, 3000 mm long, complete with bends, SS tray couplers and SS hardware viz bolts/nuts/washers, etc. as per drawings enclosed. The scope of work shall be as noted below; The erection scope shall include transportation, handling at site, storage, inspection, safe custody, fixing to structural supports, jointing wherever required, etc. The GRP trays are to be laid over fabricated MS cable racks. The scope shall also include, supply of bolts, nuts, clamps, washers, etc. The bolts, nut, washers shall be of SS.
Supply and wiring for light point/ exhaust fan with 1.5Sq.mm FRLSH PVC insulated stranded single core copper conductor cable through 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark clamped in wall, ceiling or column including supply and fixing of 3Plate ceiling rose in 3x3 Box with UPVC cover in wall,1No 6A modular switch (CRABTREE or equivalent) modular plate in suitable box for surface mounting and earthing with 1.5Sq.mm insulated copper conductor etc. including supply of all fixing materials and accessories and interconnections complete as required. Refer Electrical layout drawings attached with this document.
Supply and wiring for group controlled light points (from one light point to another light point), same as Sl No.108 but without control switch. Wiring from control switch to first light point is covered in item No.121
Supply and wiring for ceiling fan point with 1.5 Sq.mm FRLSH PVC insulated stranded single core copper conductor cable through 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark clamped in wall, ceiling or column including supply and fixing of 3Plate ceiling rose in junction box surface in wall, 1No 6A modular switch (CRABTREE or equivalent) modular plate with regulator (CRABTREE or equivalent) in suitable type box and earthing with 1.5 Sq.mm insulated copper conductor etc. including supply of all fixing materials and accessories and interconnections complete as required. Refer Electrical layout drawings attached with this document.
Supply and wiring light points as in item above No.110 in such a way that light can be controlled from two points independently by using 2 way switch (CRABTREE or equivalent). Refer Electrical layout drawings attached with this document.
Supply and wiring for circuit/ submain wiring along with earth wire with 2Runs 4Sq.mm FRLSH PVC+4Sq.mm FRLSH PVC copper conductor as earth wire for 20A socket , through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark Concealed/surface in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board.
Supply and wiring for circuit/ submain wiring along with earth wire with 2Runs 2.5Sq.mm FRLSH PVC+2.5Sq.mm FRLSH PVC copper conductor as earth wire , through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark Concealed/surface in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board.
Supply and Wiring for light point /exhaust fan/ ceiling fan with 2.5Sq.mm PVC insulated armoured three core copper conductor cable in wall, ceiling or column or floor including supply and fixing of 3Plate ceiling rose in 3x3 Box with UPVC cover in wall ,1No 6A modular switch( CRABTREE or equivalent) modular plate in suitable GI box etc.The scope shall also include Supply of weather proof single compression Nickel plated brass cable glands suitable for 650/1100V grade cables including supply of all fixing materials and interconnections, terminations complete as required.Refer Electrical layout drawings attached with this document.
Supply and Wiring for group controlled light points (from one light point to another light point), same as Sl No. 127 but without control switch. Wiring from control switch to first light point is covered in item No.127
Supply and erection of 3 pin 5/6 amps modular socket (CRABTREE or equivalent)outlet and 5/6 amps modular switch( CARABTREE or equivalent), with modular front plate and cover in surface mounting box suitable for modular switches with all fixing materials and interconnections as required . Scope shall also include supply of cable glands and termination of cables as required.
Supply and erection of 3pin 15/16 amps modular socket (CRABTREE or equivalent) outlet and 15/16amps modular switch with indicator (CRABTREE or equivalent) , with modular front plate and cover in surface mounting box suitable for modular switches with all fixing materials and interconnections complete as required.Scope shall also include supply of cable glands and termination of cables as required.
Supply and erection of 2 pair Telephone cables with surface /concealed conduit system of wiring, cabling through cable duct, cable tray etc. with annealed high conductivity copper conductor 0.5mm dia, polyethylene insulated, cores twisted in to pairs, bunched together, laid up, cores taped with absorbant tape, polyethelene sheathed, overall polyethlene jacketed unarmoured cable conforming to TTE/ITD specification .Erection scope shall include all accessories including erection of 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark
Supply and erection of 3 pin 5/6 amps modular socket (CRABTREE or equivalent)outlet and 5/6 amps modular switch( CRABTREE or equivalent), with modular front plate and cover in box suitable for surface/concealed (according to site requirement) mounting in wall with all fixing materials and interconnections as required .
Supply and erection of 3pin 15/16 amps modular socket (CRABTREE or equivalent) outlet and 15/16amps modular switch with indicator (CRABTREE or equivalent) , with modular front plate and cover in box suitable for modular switches for surface /concealed (according to site requirement) mounting in wall with all fixing materials and interconnections complete as required.
Supply and erection of modular type, RJ 11 Telephone socket (CRABTREE or equivalent) , with non metallic front plate including suitable size box surface /concealed (according to site requirement) mounting in wall with all necessary accessories and interconnections complete as required.
Supply and erection of three Nos of 3 pin 5/6 amps modular socket (CRABTREE or equivalent)outlet and three nos of 5/6 amps modular switch( CRABTREE or equivalent), with modular front plate and cover in box suitable for surface /concealed (according to site requirement) mounting in wall with all fixing materials and interconnections as required .(Computer Points)
Supply and erection of 20 A DP modular switch with indicator (CRABTREE or equivalent) and Modular socket (CRABTREE or equivalent),modular front plate and cover in box suitable for modular switches on wall including all fixing materials and interconnection complete as required. The switch and socket shall be installed at a height of 1.2 metre and 2.4 metre respectively from floor level.For the A/C units suitable openings shall be made in co-ordination with Civil contractor for taking the tubings to outdoor units. 2.5inch dia PVC pipes shall be used for providing openings and these openings shall be properly sealed after erection of A/C set. At points where A/C sets are not envisaged now ,2.5 inch PVC pipes shall be closed using suitable end caps.
Supply and erection of 230 V, 16A,socket outlet in cast Aluminium IP 55 weather proof enclosure with integral switch plug socket arrangement , cable glands, cable entries, plug top, duplicate earthing terminals, safety interlock to prevent accidental removal of plug while the unit is ON, provision for looping to other unit etc. The incoming cable size shall be 4C x 4 sq.mm YFY/ YWY cable . All external hardwares shall be stainless steel. Suitable canopy and sealing plug for unused cable entry shall be provided
Supply, erection, testing, commissioning and handing over of Flame proof, weather proof, cast Aluminium, 16A socket with switch and plug top. The socket shall have interlock facility with switch so that it is not possible to remove the plug without switching OFF the switch or insert the plug in ON position.Socket shall be suitable for cable entry of size 1No 3Cx4Sq.mm YFY/YWY cable (for battery Room)
Supply, erection, testing, commissioningNonFlame proof Local Control Stations for emergency stop by the side of transformer, with IP55,weather proof cast Aluminium enclosure as per specifications attached.Cable entry shall be suitable for 3 x 2.5 sq.mm YFY/YWY cable.
Supply, erection, testing, commissioning NonFlame proof Local Control Stations for Start and stop opeartion of pumps , with LED indication lamps, IP55 weather proof cast Aluminium enclosure as per specifications attached.Cable entry shall be suitable for 5C x 2.5 sq.mm YFY/YWY cable.
Supply, installation, testing, commissioning and handing over of shock proof, rust proof, dust proof, water proof, corrosion proof junction boxes in Thermoplastic Polystyrene enclosure, having internally embedded gasket and suitable dust caps to seal the mounting slots with plane wall surface for different cables. cable glands / bushes of suitable sizes and all other required hard wares shall be included in scope of supply. The junction boxes supplied shall be Hensel make or equivalent as certified by Engineer in Charge. Mounting of junction boxes shall be on wall / pedestals etc. as required at a height of 1.5m from floor as per the drawing. The scope shall include supply of fixing hardware required for the same. All spare entries of the junction boxes shall be suitably blanked. Fixing bolts / nuts/ screws shall be stainless steel. The scope include drilling suitable holes for cable entry. Junction boxes with Krone type connectors suitable for terminating 1 No. 10 Pair, 0.5mm dia unarmoured cable as incomer and 8Nos 2Pair 0.5 mm dia un armoured cable as outgoing.
Supply and erection of 20W LED WEATHERPROOF type tube light fixed suitable for surface mounting prewired upto terminal block with all accessories such as drivers lamp holders, lamp, cable gland etc. with transparent PC cover and all related accessories like rods for suspension, wires etc. as required (PHILIPS WT150C LED 20S 6500 PSU L120 or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells/ Bajaj. Refer sl no. 4.0 of Annexure.
Supply and erection of Weatherproof, 45W LED type well glass lighting fixtures with double compression cable glands ,rods for suspension and all related accessories. All external hardwares shall be stainless steel., . Erection scope shall also include glanding of cable at the light fitting and at the switchboard. (FCG Type No: LW 21202S or equivalent type of BALIGA/FLAMEPROOF EQUIPMENTS/FLEXPRO/SCG )
Supply and erection of 20W LED batten suitable for surface / Conduit mounting prewired upto terminal block with all accessories such as drivers lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (PHILIPS BN308C LED20S 6500 L60 PSU WH or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells/ Bajaj)
Supply and erection of 36W LED TYPE light fittings suitable for recess mounting all required accessories for fixing and connecting the fitting to the point. (Philips RC380B LED36S -6500 G5 L60 W60 PSD OD WH OC or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells /OSRAM/ Bajaj)
Supply and erection of 12W LED TYPE light fittings suitable for surface mounting with lamp(colour temperature white) all required accessories for fixing and connecting the fitting to the point.(PHILIPS SM 250C LED 12S 6500 PSU WH or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells /OSRAM/ Bajaj)
Supply and erection of 30W LED TYPE light fittings suitable for recess mounting all required accessories for fixing and connecting the fitting to the point. (Philips RC380B LED30S -6500 G5 L3W12 PSU OD or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells /OSRAM/ Bajaj)
Supply and erction of Flameproof Ex-d IP65 Tube light fitting suitable for 1x20W LED tube for gas groupIIA/IIB/IIC with flame proof double compression cable glands, wire guard, internal and external earth studs suitable for battery room application with all accessories.
Supply and erction of Flameproof EX-d IP66 exhaust fan suitable for Gas group IIC with flame proof double compression cable glands, wire guard, internal and external earth studs gravity louvers shutters rigid frame with rubber mountings and of 350mm sweep suitable for battery room application with all accessories.
Supply and erction of Heavy duty, totally enclosed motor, EXHAUST FAN suitable for operation on 230Volts, 50Hz single phase AC supply complete with standard length of 3 core flexible copper conductor cable, and of 230 mm sweep conforming to IS-2312 (with latest amendments).
Supply and erection of 1200mm sweep BLDC ceiling fans, complete with standard length down rod, canopies, shackle, rubber bush, blades, remote etc. Fan shall be suitable for operation on 230V, 50HZ single phase AC supply pre wired upto terminal block. (HAVELLS model Efficiencia Neo or equivalent)
Supply and erction of 150W LED type highbay light fixture in ADC housing suitable for industrial application with all related accessories such as driver, LED lamp , cable glands etc. The scope shall also include supply of rods/hooks required for suspending the light fittings from the ceiling Erection scope shall also include terminaion of cables using cable glands(PHILIPS-BY515P LED150S 5700 NB PSU GR or equivalent type )
Excavation and backfilling of trenches for laying of cables/earthing conductor, pipes, foundations and earth strips etc in all types of soils including hard laterite except rock for a maximum depth of 0.6 M, shoring, strutting, de-watering ( if required) The scope include shoring, strutting, dewatering if required, consolidating and disposing of surplus earth, all labour materials, tools etc. complete as per the directions of Engineer in Charge.
Removal of cover slab of cable trench for cable laying, reinstallation and sealing of RCC cover slab over built up cable trench (with suitable sealing compound) after laying of cables
Supply of 100mm NB (GI-class B). The scope shall also include fabrication, bending, welding, etc. wherever applicable. The erection rate indicated below shall be applicable also for pipes if any issued by FEDO/Owner. For other requirements refer Annexure.
Erection - installation, laying and fixing of 100mm NB (GI-class B). The scope shall also include fabrication, bending, welding, etc wherever applicable. The erection rate indicated below shall be applicable also for pipes if any issued by FEDO/Owner. For other requirements refer Annexure.
Supply of spares as per spares list
Supply and erection of 19 mm. NB (GI-Class B) (for installing well glass light fittings/ as platform lighting pole)
Supply and installation of Danger Notice plates, for 6.6k V system as per relevant IS. safety items at appropriate places in the sub-station as per enclosed specifications. Structural supports are excluded from the scope of this item.
Supply and installation of Danger Notice plates, for 415 V system as per relevant IS. safety items at appropriate places in the sub-station as per enclosed specifications. Structural supports are excluded from the scope of this item.
Supply and installation of 4.5Kg CO2 fire extinguishers, wall mounting type as per relevant IS. safety items at appropriate places in the sub-station as per enclosed specifications. Structural supports are excluded from the scope of this item.
Dry chemical fire extinguishers 5 kg as per IS: 2171-1976 mounted on wall hooks.
Shock treatment chart both in Malayalam & English for treating person suffering due to electric shock mounted on wall hooks.
First aid box containing material as prescribed by St. John Ambulance brigade OR Indian Red Cross complete as required.
G.I. Fire buckets 13 litre capacity filled with dry sand and fixed on wall on hook made out of 13mm dia MS rod & conforming IS 2546 - 1974.
Hand gloves suitable for 11KV voltage with suitable box for keeping the gloves
11kV grade insulation mat as per IS 15652 of thickness not less than 2.5mm and 1000mm wide
1.1KV grade insulation mat as per IS 15652 of thickness not less than 2.0mm and 1000mm wide( different coloured Insulation mat shall be used for HT and LT purposes)
Labour rates for Helper with tools on 8hour (normal day time) shift basis for attending any work as directed by site in charge/owner during execution of the contract. The charges shall include supervision and supply of consumables such as insulation tapes ferrule etc.
Labour rates for Electrician with tools on 8hour (normal day time) shift basis for attending any work as directed by site in charge/owner during execution of the contract. The charges shall include supervision and supply of consumables such as insulation tapes ferrule etc.
Labour rates for Electrical supervisor with tools on 8hour (normal day time) shift basis for attending any work as directed by site in charge/owner during execution of the contract. The charges shall include supervision and supply of consumables such as insulation tapes ferrule etc.
Labour rates for Electrical supervisor at site on over time basis (after normal shift time of 8 hour)
Labour rates for Electrician at site on over time basis (after normal shift time of 8 hour)
Labour rates for Helper at site on over time basis (after normal shift time of 8 hour)
Conducting measurement of soil resistivity as per IS-3043 at two representative locations at site as directed by Engineer-in-charge and furnishing soil resistivity report duly certified by Electrical Inspectorate. Sufficient number of tests/measurement shall be conducted at a particular location to find out average soil resistivity as per IS 3043. (The agency shall bring all necessary equipments/ instruments for the soil resistivity measurement and the quoted rate shall include all incidental expenses and fees payable to Electrical Inspectorate for witnessing the soil resistivity measurement and certifying the report).
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .