Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 CrAccepted-AOC | ₹6.8 Cr | L1 | Accepted-AOC OFBa CWC-I Decided to Accept the Offer and Place the Work Order on M/s. Ankit Fatehsingh Chouhan, Gondia at the Quoted Rate Rs. 68301147.12/-. |
| 2 | L2₹6.9 CrRejected-Finance | ₹6.9 Cr | L2 | Rejected-Finance As Per CWC-1 Decision Held On 26/02/2026. |
| 3 | L3₹7.4 CrRejected-Finance | ₹7.4 Cr | L3 | Rejected-Finance As Per CWC-1 Decision Held On 26/02/2026. |
| 4 | L4₹7.4 CrRejected-Finance | ₹7.4 Cr | L4 | Rejected-Finance As Per CWC-1 Decision Held On 26/02/2026. |
| 5 | L5₹9.1 CrRejected-Finance | ₹9.1 Cr | L5 | Rejected-Finance As Per CWC-1 Decision Held On 26/02/2026. |
| Sl No | Description | Qty | Unit | ANKIT FATEHSINGH CHOUHAN L1 | Mehadia Infrastructure L2 | VIRA INFRASTRUCTURE L5 | M A BUILDERS L3 | Mohit Infratech L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for grubbing up tree trunk exc. 30 cm and n exc. 100 cm girth including cutting of trunk portion protruding over ground , digging out roots ,filling holes and levelling off ground , stacking of serviceable material an removing of unserviceabe material to a distance n exc.50 m and ciearing site, complete all as specified. | 30 | Each | 1,853 ₹55,590 | 1,071 ₹32,130 | 1,869.1 ₹56,073 | 1,500 ₹45,000 | 900 ₹27,000 |
| 2.00 | Surface dressing n exc 15 cm deep in hard dence soil and getting out as directed by EIC | 2,493 | SQM | 12 ₹29,916 | 19.8 ₹49,361.40 | 24.9 ₹62,075.70 | 30 ₹74,790 | 23 ₹57,339 |
| 3.00 | Excavating in trenches, not exc 1.5m wide and not exc 3.0 m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in hard/dense soil, complete all as specified | 3,200 | cum | 200 ₹6.4 L | 450 ₹14.4 L | 560.7 ₹17.9 L | 220 ₹7.0 L | 270 ₹8.6 L |
| 4.00 | Excavating over areas, n exc 1.5 m deep and getting out in hard dense soil complete all as specified as directed by EIC | 770 | cum | 200 ₹1.5 L | 306 ₹2.4 L | 467.3 ₹3.6 L | 220 ₹1.7 L | 280 ₹2.2 L |
| 5.00 | M & L for hardcore of broken stone or boulders exc 63mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rolled/rammed to a true surface, complete all as specified | 1,890 | Cum | 2,100 ₹39.7 L | 2,178 ₹41.2 L | 2,616.8 ₹49.5 L | 1,800 ₹34.0 L | 1,250 ₹23.6 L |
| 6.00 | M & L for sand filling under floors or in foundations including watering and consolidation, complete all as specified | 475 | Cum | 2,360 ₹11.2 L | 2,178 ₹10.3 L | 2,242.9 ₹10.7 L | 2,500 ₹11.9 L | 2,000 ₹9.5 L |
| 7.00 | M & L for PCC 1:4:8 Type D2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge. | 880 | Cum | 4,350 ₹38.3 L | 3,870 ₹34.1 L | 5,607.4 ₹49.3 L | 4,500 ₹39.6 L | 4,700 ₹41.4 L |
| 8.00 | Reinforced cement concrete (design mix)in:- M-25 Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by the Engineer-in-Charge | 1,200 | Cum | 6,750 ₹81 L | 7,020 ₹84.2 L | 8,722.6 ₹1.0 Cr | 6,500 ₹78 L | 7,250 ₹87 L |
| 9.00 | Reinforced cement concrete (design mix)in:-M-25Slabs supported on walls,beams and columns in floors, roofs, landings, balconies canopies, deck slabs and in shelves and the likeconcrete complete all as specified and as directed by the Engineer-in-Charge | 2,100 | Cum | 6,820 ₹1.4 Cr | 7,003.62 ₹1.5 Cr | 8,348.7 ₹1.8 Cr | 7,000 ₹1.5 Cr | 7,250 ₹1.5 Cr |
| 10.00 | M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams , and similar work, vertical or to batter, work in rough finished flat surfaces of concrete complete all as specified and as directed by E-I-C | 4,900 | sqm | 243 ₹11.9 L | 225 ₹11.0 L | 436.1 ₹21.4 L | 250 ₹12.3 L | 100 ₹4.9 L |
Updated dates
Tender Value
₹8.6 Cr
EMD Value
₹7.5 L
Closing Date
4 Dec 2025, 2:30 pmClosed
CHIEF GENERAL MANAGER
O F BHANDARA
Construction of New Proposed Building No. SBP- 312(10.0MT/D-1.3) for Cartriadging and Palleting of M4A2 Charge at Single Base Propellant (SBP) Section inside factory at O.F. Bhandara.
2025_MIL_250856_1
EO/F/51/ND2414/BF
Open Tender
Civil Works - Buildings
182 days
O.F.Bhandara
As per tender document
7 documents required · 7 mandatory
₹0
₹7.5 L
Yes
O.F.Bhandara
26 Feb 2026
30 Sept 2025
6 Dec 2025
30 Sept 2025
4 Dec 2025
30 Sept 2025
10 Oct 2025
M & L for grubbing up tree trunk exc. 30 cm and n exc. 100 cm girth including cutting of trunk portion protruding over ground , digging out roots ,filling holes and levelling off ground , stacking of serviceable material an removing of unserviceabe material to a distance n exc.50 m and ciearing site, complete all as specified.
Surface dressing n exc 15 cm deep in hard dence soil and getting out as directed by EIC
Excavating in trenches, not exc 1.5m wide and not exc 3.0 m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in hard/dense soil, complete all as specified
Excavating over areas, n exc 1.5 m deep and getting out in hard dense soil complete all as specified as directed by EIC
M & L for hardcore of broken stone or boulders exc 63mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rolled/rammed to a true surface, complete all as specified
M & L for sand filling under floors or in foundations including watering and consolidation, complete all as specified
M & L for PCC 1:4:8 Type D2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
Reinforced cement concrete (design mix)in:- M-25 Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by the Engineer-in-Charge
Reinforced cement concrete (design mix)in:-M-25Slabs supported on walls,beams and columns in floors, roofs, landings, balconies canopies, deck slabs and in shelves and the likeconcrete complete all as specified and as directed by the Engineer-in-Charge
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams , and similar work, vertical or to batter, work in rough finished flat surfaces of concrete complete all as specified and as directed by E-I-C
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) work in rough finished flat surfaces of concrete complete all as specified and as directed by the E-I-C
M & L for mild steel deformed or twisted bars TMT of 8 mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including M.S. wire (annealed) not less than 0.9mm
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius,built in cement morter 1:4 complete all as specified and as directed by the engineer -in-charge.
M & L for rendering 25mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces & is to be finished even and smooth complete all as specified and as directed by the Engineer-in-Charge
S & F 1st class hardwood chowkats and frames Plain, solid, straight, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed by the Engineer-in-Charge
S & F 40mm thick, Ist class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged); fitted to chowkats complete all as specified & directed by E-I-C.
Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as directed by E-I-C.
S & F butt hinges 150mm size, type B-12, extruded brass, with mild steel hinge pin, bright polished complete all as specified& directed by E-I-C.
S & F butt hinges 100mm size, type B-12, extruded brass, with mild steel hinge pin, bright polished complete all as specified and as directed E-I-C.
S & F 375mm long brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts complete all as specified and as directed by the Engineer-in-Charge
S & F 300mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified
S & F 150mm extruded brass handles, fabricated type polished complete all as specified and as directed by the Engineer-in-Charge
Floor door stopper of aluminium alloy 150 mm body & tongue, anodised, with hard drawn steel spring, fixed in floor
M &L for prepration of new surfaces including brooming down OR steel wire brushing , srapping down smoke ot,moulds,moss,and effloresent salts and trading oil and greasy spot of surfaces new surfaces of concrete, brick workk, AC sheet or plasterd wall surface and applying two coat of anti fungale paint make Asian Royale aspira or equilant over one coat of priming paint plaster coat etc. completed as directed by E-I-c
M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
M&L 3mm thick wall care putty on wall.
3mm thick wall care putty on ceiling
M&L Preparation of new or previously untreated surfaces and painting Bricks, stone, concrete, asbestos cement or plaster surfaces of any description over 10 cm width or girth not otherwise described with one coat of Priming paints plaster coat and two coats of synthetic enamel paint./lead free paint will be BERGER/ASIAN/NEROLAC ,colour code will be as per directed by E-Ic
M&L for bitumen mastic antistatic flooring 25 mm thick with matt finish in floor confirming to IS - 8374 (1977 ), IS - 1195 ( 2002 ) and IS - 1196 (1978 reafferiming 2001), with application of bitumen primer and 32 gauge brass strip 25 mm wide laid @ 300 mm C/C both way and fixed with brass screw and grits including testing of floor for electric resistivity in between 50x10 ³ ohms 2X10 ⁶ ohms etc. all as specified and directed by EIC.
M & L for 25 mm thick Bitumen mastic to vertical surface of drains/walls in two coats with application bitumen primer and making rounded at joint of floor- wall including wired o.90 mm dia, 16mm mesh fixed with tinned tickets or wire staples at 150 mm C/C all as specified and directed by EIC.
Finishing cement concrete surface even and smooth using extra cement
M & L for applying two coats of bituminus based aluminium paint over water proofing membrane as directed by E-I-C
M& L for liquid water proofing compound and mixing in wet concrete as directed by E-I-C
APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. Not less than 150 gms/sqm) land on primed surface by forced application omplete all as specified.
Bitumen primer for use in waterproofing and damp-proofing treatments
M & L Prepration of new cement plaster ,brick ,surfaces etc.and apply one coat of primer exept paint
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
M & L for rough cast wired glass 6.4 mm thick, ordinary quality and glazing with oil putty in square exc 0.5 sq m in each pane complete all as specified &as directed by EIC.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, amming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and as directed by EIC
M & L for brushing neat cement slurry with 3.0 kg of cement per sqare meter and finishing by brooming Complete as specified.
Returning ,filling in including spreading leveling,watering and well ramming in layers not exc.25 cm in hard dense soil complete all as specified and as directed by the E-I-C
M&L for Forming 20mm thick Expansion joints 200mm filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’
Soling Spread thickness in 200 mm (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and as directed by the E-I-C.
M & L for granular sub base & light wearing surfaces with moorum/ red bajri 75 mm thick ness spred rolled&consolidated to gradient and camber required complete all as specified and as directed by the E-I-C.
M&L for Antitermite Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
M&L Aluminum die cast body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Grouting with emulsion of 50 kg cement mixed with Dr.fixit pidicrete AM 225 gm/ Aqua tek grout AID or equilant in existing RCC roof slab or vertical position with a pressure not less than 7 kg /Sgcm till reverse flow appears including drilling holes 40 mm deep and fixing 20 mm dia PVC nozzles after grouting etc. complete all as per manufactures instructions & direction of E-I-C
Rough excavation in trenches in soft / loose soil not exceeding 1.5 m deep and getting out for laying of cable.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
M & L fine sand filling in the trench for coushoning of cable size
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm.
Supply and fixing of GI pipe medium grade80 mm dia. Under the road/hard standing.
Supply and fixing of GI pipe medium grade 25 mm dia. Under the road/hard standing.
Supply and fixing of GI pipe medium grade 50mm dia under road/culvert/pole/LP finials with fixing GI clamp.
M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 core X 4 Sq. mm. GLOSTER/POLYCAB/HAVELLS/UNIFLEX or equivalent MAKE.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Surya, Bajaj, Philips or equivalent make.
M & L Steel tubulers swaged poles complete with cast iron based plate, finial taper plug, bolts,nuts & screws as per specified type 410 SP -31 . ( 9 mtr long )
Supply and fixing 5 to 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.HPL/Havells/L&T/C&S or equivalent make
M & L for Earthing complete with galvanised steel earth plate electrode 600×600× 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion .
Excavating in trenches (hard/dense soil), n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out
Supply & fixing of G,I Pipe medium grade 25 mm Dia with GI nuts & bolts ,2 nos of clamp ,funnel etc as watering pipe in earth pits.
Material and labour for precast cement concrete hollow block masonry exc. 10 cm in width and setting in mortar complete (Set in Cement mortar 1:6) , (type 1:3:6 using 16 mm graded aggregate ) as per IS 383. size 50 X 50 X 80 cm( outer dimension),
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sq. mm.3.5 core. GLOSTER/POLYCAB/HAVELLS/UNIFLEX or equivalent MAKE.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6 mm G.I Strip .
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25X4 mm G.I Strip.
M & L for PCC of 1:2:4 of type B -2 Using 40mm graded aggregate for making foundation of LP finilal/steel tubelar swaged pole .
M & L Air termination for LP system single point aluminium rod 12 mm dia. 300 mm long.
of Flameproof switches ,rotary type with termination box in LM 6, 16A,double pole,250 V,duly certified by CIMFR, Dhanbad . Make: CG/Sudhir Switchgear/Shyamm or any reputed make. Or equivalant
S&F of Flameproof switches socket and plug combined in LM 6 cable termination box in LM6,16A,250V, 2P+earth. Duly certified by CIMFR, Dhanbad . Make: CG/Sudhir Switchgear/Shyamm or or equivalent make.
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required in Steel Conduit. Size 2X2.5 sq.mm +1X2.5 sq.mm earth wire make : Polycab/Finolex/V-Guard/HPL/L&T or equivalent.
Supply & Fixing for Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required in Steel Conduit. Size 2X4.0 sq.mm +1X2.5 sq.mm earth wire make : Polycab/Finolex/V-Guard/HPL/L&T or equivalent.
S&F of sheet metal enclosure with single door, outdoor type distribution box made out of CRCA sheet metal 2 mm thick on pole 415 V consisting of 1 nos. of 63 Amp. RYBN connector and one no. of 6A MCB SPN with bottom cable entry with detachable plate, danger sticker 415 V and fixed with rubber gourments.The DB cover will have lockable arrangements. The DB should be of size 300X300X150 mm, double GI clamp of 25X5 mm to be provided to fixed the DB on pole.HPL/Havells/L&T/C&S or equivalent make
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required
Supply & Fixing of Flameproof LED Well glass ,40 Watt , duly certified by CIMFR, Dhanbad . Make: CG/Sudhir Switchgear/Shyamm or equivalent
Supply & Fixing of Flameproof junction box, 16 Amp rating, 4Way connector,100mm dia duly certified by CIMFR,Dhanbad.Make: CG/Sudhir Switchgear/Shyamm or equivalent
Supply & Fixing of Flameproof Gland ,size 19mm , Double compresson type duly certified by CIMFR,Dhanbad.
Supply & Fixing of Flameproof Gland ,size 25mm , Double compresson type duly certified by CIMFR,Dhanbad.
S & F Flameproof Exhaust fan, single phase, 18" 1400 rpm with CIMFR Bhanbad certified for gas group IIA & IIB as per IS 2148 with suitable grouting arrangement as directed by EIC. Make CG/Sudhir Switchgear/Shyamm /Patco or equivalent
Returning filling including spreading, levelling, watering and well ramming in layers not exc.25 cm.hard dense soil.
Supplying, installation, testing & commissioning of cubical type INDOOR LT PCC panel with (150 KVAr) APFC condenser bank- 01 No. complete with suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2.5 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade having 500 Amps capacity extensible type TPN Electrolytic Tinned copper busbars of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panels shall have 2 nos. common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud for each earth bar, solid connections from main bus bar to switch gears with required size of copper bus bars and control wiring with 2.5 sq.mm. FRLS copper conductor single core cable, cable alleys, separate removable gland plates for each cable entry i/c providing & fixing following switch gears and assessories. Rotary Handles, spreader has to be provided for all the switchgears --- Incomer- 400Amp,4P, 65 KA MCCB- 01 no., Outgoing- 1) MCCB(4P) 315 Amp,4P, 50 KA= 01 no.(APFC panel), 2) MCCB (4P) 250 Amp, 50KA = 02nos., 3) MCCB (4P) 100 Amp,4P, 36 KA = 02 nos., 4) MCCB (4P) 63 Amp, 36 KA =04 nos., 5) DP 32 Amp MCB =16 nos. (For building Light) All MCCB shall be extended rotary handle operating system, breaking capacity as indicated in specification with adjustable overload and adjustable short circuit setting. Microprocessor based trip unit shall be provided for 400A, 315A & 250A. Busbar- Bus bar shall be of Insulated, high conductivity, electrolytic grade tinned copper bus bar of capacity at least 25% above full load capacity (As per incomer breaking capacity of panel) with 100 % Neutral , LED phase Indicator lamps--- RYB, ON/OFF, CT's - Class 1, 15VA , Make of MCCB: - ABB/SEIMENS/SCHNIDER ELECTRIC/L&T or equivalent. Make of MCB: - SEIMENS/SCHNIDER ELECTRIC/L&T or equivalent. Make of LED INDICATION LAMPS: ABB/SEIMENS/SCHNIDER ELECTRIC/L&T/ or equivalent. Make of capacitor duty contactor:- ABB, Schneider, Siemens or equivalent Make of Multifunctional Energy meter: HPL /CONZERV/L&T/SECURE/SCHNEIDER ELECTRIC/ABB or equivalent. Make of Current Transformer:-Faradays, Rishabh, AE, Verite or equivalent.
Supply and fixing of Aluminium checkered plate size 600x600x8mm for static charge dessipator.
PER RMT
M & L G.I. Pipe of medium grade with all fittings (Tee, nipple, socket, union, reducer, elbow of any dimension medium quality as per is 1239 part-II) laid in trecnces (as per IS 1239, part-I) 20mm
M & L G.I. Pipe of medium grade with all fittings (Tee, nipple, socket, union, reducer, elbow of any dimension medium quality as per is 1239 part-II) laid in trecnces (as per IS 1239, part-I) 25 mm
M & L G.I. Pipe of medium grade with all fittings (Tee, nipple, socket, union, reducer, elbow of any dimension medium quality as per is 1239 part-II) laid in trecnces (as per IS 1239, part-I) 50 mm
M&L Gun metal gate with iron wheel head screwed both ends for iron pipe and fixed, 20mm.
M&L Gun metal gate with iron wheel head screwed both ends for iron pipe and fixed, 25mm.
M&L Gun metal gate with iron wheel head screwed both ends for iron pipe and fixed, 50mm.
Labour only drilling and taping cast iron water pipe main (in position) for branch connection of the internal dia.20 mm.
M&L Cast iron pipes with flanged ends, centrifugally cast class A, in any length laid in trenches, 100 mm. (as per IS 1536: 1993)
M&L Cast iron pipes with flanged ends, centrifugally cast class A, in any length laid in trenches, 150 mm. (as per IS 1536: 1993)
per kg
M&L Flanged pipes & fittings joint with rubber gasket,including of bolts,nuts & washers, 100mm.
M&L Flanged pipes & fittings joint with rubber gasket, including of bolts, nuts & washers, 150mm
Cast Iron sluice valve, ISI mark, for nominal pr. PN 1.0, bolted bonnet , non rising spindle type, flange end (as per IS 1538), conforms to IS: 14846 : 2000, size- 100 mm, F TO F as per preferred dimensions 229 mm hyd.test pr.(body=1.5 mpa, seat=1 mpa).
Cast Iron sluice valve, ISI mark, for nominal pr. PN 1.0, bolted bonnet, non rising spindle type, flange end (as per IS 1538), conforms to IS: 14846 : 2000, size- 150 mm, F TO F as per preferred dimensions 267 mm hyd.test pr.(body=1.5 mpa, seat=1 mpa)
Labour only excavation in trenches, not exceeding 1.5m depth and 1.5m wide mud .
Returning filling in,including spreading, levelling, watering and well ramming in layers not exc.25 cm. soft loose soil.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.92 MB
ELIGIBILITYCONDITIONANNEXUREA.pdf
Tender Documents • 0.89 MB
TENDERACCEPTANCELETTERANNEXUREE.pdf
Tender Documents • 0.24 MB
ANNEXUREDANDDRAWING.pdf
Tender Documents • 2.95 MB
INSTRUCTIONTOBIDDERANNEXUREB.pdf
Tender Documents • 0.46 MB
STANDARDCONDITIONOFCONTRACTANNEXUREC.pdf
Tender Documents • 3.20 MB
BOQ_287862.xls
BOQ • 0.34 MB
ANNEXURE81.pdf
Additional Documents • 0.28 MB
Download all tender documents and submit your bid